(950-8300) 230 VAC COOLING FAN REPLACEMENT INSTRUCTIONS
FOR AUTO-DRAFT® INDUCERS WITH 230 VAC COOLING FANS
Remove any appliance calls for heat and disconnect power to Auto-Draft® Inducer and appliances before servicing.
1. Remove (2) screws from each Auto-Draft exterior housing side (12 total), (See Diagram A).
2. Remove Cooling Fan motor leads and (2) Screws from Auto-Draft motor cowling side (12 total), (See Diagram B).
4. Remove (2) nuts securing defective Cooling Fan to motor cowling, (See Diagram C). IMPORTANT: Verify defective Cooling Fan motor you are replacing is 230 VAC.
6. Follow Steps 2 & 1 in reverse order for reassembly. Reestablish power to Inducer and appliances. Run Inducer through a couple of heating cycles to verify proper operation.
Rev. 10/06 Copyright © 2006, Tjernlund Products, Inc. All rights reserved. P/N 8504134
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
DIAGRAM A
DIAGRAM B
DIAGRAM C
Remove (2) screws from each Auto-Draft housing side
Remove Cooling Fan motor leads
Remove (2) screws from each Auto-Draft motor cowling side
Important:
Cooling Fan air flow direction
Remove (2) nuts which secure Cooling Fan to motor cowling