and instructions. Please read and retain for
reference.
reference.
Important Safety Information • Read all safety information before
operating the equipment. Save these instructions.
This symbol indicates a hazardous situation,
which, if not not avoided could result in death or
serious injury.
To reduce the risks of fire or explosion, electrical
shock and the injury to persons, read and understand all instructions included in this manual. Be
familiar with the controls and proper usage of the
equipment.
HAZARD: INJECTION INJURY
A high pressure paint stream produced by this
equipment can pierce the skin and underlying
tissues, leading to serious injury and possible
amputation. See a physician immediately
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE
CUT! Injection can lead to amputation. See a physician
immediately
The maximum operating range of the sprayer is 3300 PSI / 22.8
MPa fluid pressure.
PREVENTION:
• NEVER aim the gun at any part of the body.
• Do not aim the gun at, or spray any person or animal.
• NEVER allow any part of the body to touch the fluid stream.
DO NOT allow body to touch a leak in the fluid hose.
• NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
• ALWAYS lock the gun trigger, shut the pump off, and
release all pressure before servicing, cleaning the tip or
guard, changing tip, or leaving unattended. Pressure will
not be released by turning off the motor. The
PRIME/SPRAY valve or pressure bleed valve must be
turned to their appropriate positions to relieve system
pressure. Refer to the PRESSURE RELIEF
PROCEDURE described in this manual.
• ALWAYS keep the tip guard in place while spraying. The
tip guard provides some protection but is mainly a
warning device.
• ALWAYS remove the spray tip before flushing or cleaning
the system.
• Paint hose can develop leaks from wear, kinking and
abuse. A leak can inject material into the skin. Inspect
the hose before each use. Do not use hose to lift or pull
equipment.
• NEVER use a spray gun without a working trigger lock
and trigger guard in place.
• All accessories must be rated at or above 3300 PSI / 22.8
MPa. This includes spray tips, guns, extensions, and hose.
• Do not leave the unit energized or under pressure while
unattended. When the unit is not in use, turn off the unit
and relieve the pressure in accordance with the
PRESSURE RELIEF PROCEDURE described in this
manual.
• Verify that all connections are secure before operating the
unit. Unsecured parts may eject at great force or leak a
high pressure fluid stream causing severe injury.
• Always engage the trigger lock when not spraying. Verify
the trigger lock is functioning properly.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury. It is
important to treat the injury as soon as possible. DO
NOT delay treatment to research toxicity. Toxicity is a
concern with some coatings injected directly into the
blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.
.
.
HAZARD: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials can
be harmful if inhaled or come in contact with the body
Vapors can cause severe nausea, fainting, or
poisoning.
PREVENTION:
• Use a respirator or mask if vapors can be
inhaled. Read all instructions supplied with the
mask to be sure it will provide the necessary
protection.
Wear protective eyewear.
•
• Wear protective clothing as required by coating
manufacturer.
HAZARD: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite.
Property damage and/or severe injury can occur
PREVENTION:
• Provide extensive exhaust and fresh air introduction to
keep the air within the spray area free from accumulation
of flammable vapors. Solvent and paint fumes can
explode or ignite.
•
Do not spray in a confined area.
• Avoid all ignition sources such as static electric
sparks, open flames, pilot lights, electrical
appliances, and hot objects. Connecting or disconnecting
power cords or working light switches can make sparks.
Paint or solvent flowing through the equipment is able to
result in static electricity.
• Do not smoke in spray area.
• Fire extinguisher must be present and in good working
order.
• Place pump at least 25 feet (7.62 meters) from the spray
object in a well ventilated area (add more hose if
necessary). Flammable vapors are often heavier than air.
Floor area must be extremely well ventilated. The pump
contains arcing parts that emit sparks and can ignite
vapors.
• The equipment and objects in and around the spray area
must be properly grounded to prevent static sparks.
• Keep area clean and free of paint or solvent containers,
rags and other flammable materials.
• Use only conductive or grounded high pressure fluid hose.
Gun must be grounded through hose connections.
• For electric units — power cord must be connected to a
grounded circuit.
• Always flush unit into a separate metal container, at low
pump pressure, with spray tip removed. Hold gun firmly
against side of container to ground container and prevent
static sparks.
• Follow the material and solvent manufacturer's warnings
and instructions. Know the contents of the paints and
solvents being sprayed. Read all Material Safety Data
Sheets (MSDS) and container labels provided with the
paints and solvents. Follow the paint and solvent
manufacturer’s safety instructions.
• Use extreme caution when using materials with a
flashpoint below 70ºF (21ºC). Flashpoint is the
temperature that a fluid can produce enough vapors to
ignite.
• Plastic can cause static sparks. Never hang plastic to
enclose a spray area. Do not use plastic drop cloths
when spraying flammable materials.
• Use lowest possible pressure to flush equipment.
Important Safety Information • Read all safety information before
operating the equipment. Save these instructions.
HAZARD: EXPLOSION HAZARD DUE TO
Will cause property damage or severe injury.
PREVENTION:
• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as
• Contact your coating supplier about the compatibility of
HAZARD:
Can cause severe injury or property damage.
•
• Follow all appropriate local, state, and national codes
• The United States Government Safety Standards have
• Use only manufacturer authorized parts. User assumes
• All hoses, fittings, and filter parts must be secured before
• Before each use, check all hoses for cuts, leaks, abrasion
• Do not kink or over-bend the hose. Airless hose can
• Do not expose the hose to temperatures or pressures in
• Do not spray outdoors on windy days.
• Wear clothing to keep paint off skin and hair.
• Do not operate or spray near children. Keep children
• Do not overreach or stand on an unstable support. Keep
• Use lowest possible pressure to flush equipment.
• Stay alert and watch what you are doing.
• Do not operate the unit when fatigued or under the
• For electric units — Always unplug cord from outlet before
• Do not use the hose as a strength member to pull or lift
• Do not lift by cart handle when loading or unloading.
INCOMPATIBLE MATERIALS
bleach, mildewcide, methylene chloride and 1,1,1 trichloroethane. They are not compatible with aluminum.
material with aluminum.
GENERAL
Read all instructions and safety precautions before
operating equipment.
governing ventilation, fire prevention, and operation.
been adopted under the Occupational Safety and Health
Act (OSHA). These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards should be consulted.
all risks and liabilities when using parts that do not meet
the minimum specifications and safety requirements of the
pump manufacturer.
operating spray pump. Unsecured parts can eject at great
force or leak a high pressure fluid stream causing severe
injury.
or bulging of cover. Check for damage or movement of
couplings. Immediately replace the hose if any of these
conditions exist. Never repair a paint hose. Replace it
with another grounded high-pressure hose.
develop leaks from wear, kinking and abuse. A leak can
inject material into the skin.
excess of those specified by manufacturer.
away from the equipment at all times.
effective footing and balance at all times.
influence of drugs or alcohol.
working on equipment.
the equipment.
Grounding Instructions
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
Improper installation of the grounding plug
can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either flat blade terminal.
The wire with insulation having a green outer surface with or
without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product is properly grounded.
Do not modify the plug provided. If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
IMPORTANT: Use only a 3-wire extension cord that has a
3-blade grounding plug and a 3-slot receptacle that will
accept the plug on the product. Make sure your extension
cord is in good condition. When using an extension cord,
be sure to use one heavy enough to carry the current your
product will draw. An undersized cord will cause a drop
in line voltage resulting in loss of power and overheating.
A 12 gauge cord is recommended. If an extension cord is
to be used outdoors, it must be marked with the suffix W-
after the cord type designation. For example, a
A
designation of SJTW-A would indicate that the cord would
be appropriate for outdoor use.
This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this instruction
manual carefully for proper operating instructions,
maintenance, and safety information.
Setup
Perform the following procedure before plugging in the power
cord of an electric unit.
1. Ensure that the siphon tube/siphon set and the return
hose are attached and secure.
2. Using a wrench, attach a minimum of 50’ of nylon airless
spray hose to the unit. Tighten securely.
3. Attach an airless spray gun to the spray hose. Using two
wrenches (one on the gun and one on the hose), tighten
securely.
NOTE: Do not attach the tip to the spray gun yet.
4. Make sure the pressure control knob is in its OFF position
5.
IMPORTANT: Never operate unit for more than ten
seconds without fluid. Operating this unit without fluid
will cause unnecessary wear to the packings.
6. Make sure the electrical service is 120V, 15 amp
7.
IMPORTANT: Always use a minimum 12 gauge, three-wire
extension cord with a grounded plug. Never remove the
third prong or use an adapter
Preparing a New Sprayer
If this unit is new, it is shipped with test fluid in the fluid section
to prevent corrosion during shipment and storage. This fluid
must be thoroughly cleaned out of the system with mineral
spirits before you begin spraying.
IMPORTANT: Always keep the trigger lock on the spray
gun in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container
3. Move the PRIME/SPRAY valve down to the PRIME
4. Turn the unit on and set the pressure to minimum by
Remove the tip if it is already attached.
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 3300
psi (22.8 MPa) fluid pressure.
in the black zone.
Fill the wet cup with one tablespoon of piston seal
lubricant (Piston Lube).
minimum.
Plug the power cord into a properly grounded outlet at
least 25’ from the spray area.
.
.
position.
turning the pressure control knob to the “Min PSI” setting
in the yellow zone.
Operation
This equipment produces a fluid stream at
extremely high pressure. Read and understand
the warnings in the Safety Precautions section at
the front of this manual before operating this
equipment.
5. Allow the sprayer to run for 15–30 seconds to flush the
test fluid out through the return hose and into the waste
container.
6. Turn the unit off by moving the pressure control knob to
the OFF position in the black zone.
Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
IMPORTANT: Always keep the trigger lock on the spray
gun in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
2.
3. Move the PRIME/SPRAY valve down to the PRIME
4. Turn the unit on and set the pressure to
5. Allow the sprayer to run for 15–30 seconds
6. Turn the unit off by moving the pressure control knob to
NOTE: Make sure that the spray gun does not have a
7. Move the PRIME/SPRAY valve up to the SPRAY position.
8. Turn the unit on and set the pressure to minimum by
9. Unlock the gun by turning the gun trigger lock to the
10. Trigger the gun into the metal waste container until the old
11.
12. Set down the gun and increase the
13. Check the entire system for leaks. If
14. Follow the “Pressure Relief Procedure” in this manual
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer’s fluid section.
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
Place the return hose into a metal waste container.
position.
minimum by turning the pressure control
knob to the “Min PSI” setting in the yellow
zone.
to flush the old solvent out through the
return hose and into the metal waste container.
the OFF position in the black zone.
tip or tip guard installed.
turning the pressure control knob to the “Min PSI” setting
in the yellow zone.
unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure
to do so may lead to a static
electric discharge, which may
cause a fire.
solvent is gone and fresh solvent is coming out of the gun.
Lock the gun by turning the gun
trigger lock to the locked position.
pressure by turning the pressure
control knob slowly clockwise into the
green zone.
leaks occur, follow the “Pressure Relief Procedure” in this
manual before tightening any fittings or hoses.
before changing from solvent to paint.
Be sure to follow the pressure relief procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
Painting
1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Move the PRIME/SPRAY valve down to the PRIME position.
4. Turn the unit on and set the pressure to
minimum by turning the pressure control knob
to the “Min PSI” setting in the yellow zone.
5. Allow the sprayer to run until paint is
coming through the return hose into the
metal waste container.
6. Turn the unit off by moving the pressure
control knob to the OFF position in the black zone.
7. Remove the return hose from the waste container and place
it in its operating position above the container of paint.
8. Move the PRIME/SPRAY valve up to the SPRAY position.
9. Turn the unit on and set the pressure to minimum by
turning the pressure control knob to the “Min PSI” setting
in the yellow zone.
10. Unlock the gun by turning the gun trigger lock to the
unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
11. Trigger the gun into the metal waste
container until all air and solvent is flushed from the spray
hose and paint is flowing freely from the gun.
12. Lock the gun by turning the gun trigger
lock to the locked position.
13. Turn the unit off by moving the
pressure control knob to the OFF
position in the black zone.
14. Attach tip guard and tip to the gun as
instructed by the tip guard or tip manuals.
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the
unclog position. Always engage the gun trigger
lock before removing, replacing or cleaning tip.
15. Turn the unit on and set the pressure to minimum by
turning the pressure control knob to the “Min PSI” setting
in the yellow zone.
16.
Increase the pressure by turning the pressure control
knob slowly clockwise toward the green zone and test the
spray pattern on a piece of cardboard. Adjust the
pressure control knob until the spray from the gun is
completely atomized.
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear
and additional overspray.
Electronic Pressure Control Indicators
The following is a description of the electronic pressure control
indicators.
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
• The sprayer is plugged in and turned “ON”.
• The sprayer is at priming pressure (little or no pressure).
• It is safe to move the PRIME/SPRAY valve between
positions.
• It is safe to change or replace the spray tip.
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a
higher pressure and the PRIME/SPRAY valve is
in the SPRAY position, either the spray tip is
worn or the sprayer is in need of service/repair.
4. Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
5. Trigger the gun to remove any pressure
that may still be in the hose.
6. Lock the gun by turning the gun trigger lock to the locked
position.
7. Move the PRIME/SPRAY valve down to the PRIME
position.
Spraying
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the
unclog position. Always engage the gun trigger
lock before removing, replacing, or cleaning tip.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 200 and 1800 PSI.
indicator means:
• The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors.
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates
one of the following:
a. Tip Wear Indicator — when spraying with latex or at
high pressure the solid yellow appears. This means
the tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the
sprayer is put in the gun, the pressure indicator will turn
from solid green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure
indicator appears when using a new tip and the
pressure is set at maximum, service may be required
(worn packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is
operating between 1800 and 3300 PSI. A solid green pressure
indicator means:
• The sprayer is at the proper pressure setting for spraying
oil-based and latex house paints.
• The sprayer is operating at peak performance at a high
pressure setting.
A solid yellow pressure
Motor Running Indicator
The Motor Running indicator is on when the motor is
commanded to run. This indicator is used by service centers
to troubleshoot motor problems.
Spraying Technique
The following techniques, if followed, will assure professional
painting results.
Hold the gun perpendicular to the surface and always at equal
distance from the surface. Depending on the type of material,
surface, or desired spray pattern, the gun should be held at a
distance of 12 to 14 inches (30 to 35 cm).
Move the gun either across or up and down the surface at a
steady rate. Moving the gun at a consistent speed conserves
material and provides even coverage. The correct spraying speed
allows a full, wet coat of paint to be applied without runs or sags.
Holding the gun closer to the surface deposits more paint on
the surface and produces a narrower spray pattern. Holding
the gun farther from the surface produces a thinner coat and
wider spray pattern. If runs, sags, or excessive paint occur,
change to a spray tip with a smaller orifice. If there is an
insufficient amount of paint on the surface or you desire to
spray faster, a larger orifice tip should be selected.
Maintain uniform spray stroke action. Spray alternately from
left to right and right to left. Begin movement of the gun before
the trigger is pulled.
Pressure Relief Procedure
1. Lock the gun by turning the gun trigger
lock to the locked position.
2.
Turn the pressure control knob
counterclockwise to its OFF position in
the black zone.
3. Unlock the gun by turning the gun
trigger lock to the unlocked position.
Be sure to follow the pressure relief procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
Avoid arcing or holding the gun at an angle. This will result in
an uneven finish.
Proper lapping (overlap of spray pattern) is essential to an
Good spray pattern
Paint tailing pattern
Overlap edges
1st
pass
2nd
pass
3rd
pass
4th
pass
5th
pass
On/Off
Clean
Min.
PSI
(Bar)
Max. PSI
(Bar)
S
p
r
a
y
L
a
t
e
x
P
a
i
n
t
s
&
H
e
a
v
i
e
r
C
o
a
t
i
n
g
s
S
p
r
a
y
C
l
e
a
r
s
,
L
a
c
q
u
e
r
s
&
E
n
a
m
e
l
s
even finish. Lap each stroke. If you are spraying horizontally,
aim at the bottom edge of the preceding stroke, so as to lap
the previous pattern by 50%.
For corners and edges, split the
center of the spray pattern on the
corner or edge and spray vertically
so that both adjoining sections
receive approximately even
amounts of paint.
When spraying with a shield, hold it firmly against the surface.
Angle the spray gun slightly away from the shield and toward
the surface. This will prevent paint from being forced
underneath.
Shrubs next to houses should be tied back and covered with a
canvas cloth. The cloth should be removed as soon as possible.
Titan gun extensions are extremely helpful in these situations.
Nearby objects such as automobiles, outdoor furniture, etc.
should be moved or covered whenever in the vicinity of a
spray job. Be careful of any other surrounding objects that
could be damaged by overspray.
Practice
1. Be sure that the paint hose is free of kinks and clear of
2. Turn the pressure control knob counterclockwise to its to
3. Turn the PRIME/SPRAY valve up to its SPRAY position.
4. Turn the pressure control knob clockwise to its highest
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to
setting. The paint hose should stiffen as paint begins to
flow through it.
check the spray pattern.
necessary to get a good spray
pattern. If the pressure is set too
high, the spray pattern will be too
light. If the pressure is set too
low, tailing will appear or the paint
will spatter out in gobs rather than
in a fine spray.
Cleanup
Special cleanup instructions for use with
flammable solvents:
• Always flush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
IMPORTANT: The sprayer, hose, and gun should be
cleaned thoroughly after daily use. Failure to do so
permits material to build up, seriously affecting the
performance of the unit.
Always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2.
Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to its PRIME position.
6. Turn the unit on and set the pressure to
Turbo PulseClean by turning the pressure
control knob to its CLEAN position in the
red zone.
7. Allow the solvent to circulate through the
unit and flush the paint out of the return
hose into the metal waste container.
8. Turn the unit off by moving the pressure control knob to
the OFF position in the black zone.
9. Move the PRIME/SPRAY valve up to its SPRAY position.
10. Turn the unit on and set the pressure to Turbo PulseClean
by turning the pressure control knob to its CLEAN position
in the red zone.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure
to do so may lead to a static
electric discharge, which may
cause a fire.
11. Trigger the gun into the metal waste container until the
paint is flushed out of the hose and solvent is coming out
of the gun.
12.
Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
13. Follow the “Pressure Relief Procedure” found in the
14. Unplug the unit and store in a clean, dry area.
IMPORTANT: Do not store the unit under pressure.
mineral sprits through the entire system.
For short-term storage when using latex paint,
pump water mixed with Titan Liquid Shield Plus
through the entire system (see the Accessories
section of this manual for part number).
Operation section of this manual.
Maintenance
Filter Body
Filter Spring
Filter Spring
Adapter
Core Spring
Filter
O-ring
Filter Housing
Gasket
Dowel Pin
Cam Base
Valve Stem
Filter
Housing
Valve Housing
Assembly
Valve
Handle
Groove Pin
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
1. Before repairing any part of the sprayer, read the
IMPORTANT: Never pull on a wire to disconnect it. Pulling
on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
3. Make certain that the service area is well ventilated in
4. If you have any further questions concerning your TITAN
Replacing the PRIME/SPRAY Valve
Perform the following procedure using PRIME/SPRAY valve
replacement kit P/N 800-915.
1. Push the groove pin out of the valve handle.
2. Remove the valve handle and the cam base.
3. Using a wrench, loosen and remove the valve housing assembly.
4. Make sure the gasket is in place and thread the new valve
5. Place the cam base over the valve housing assembly.
6. Line up the hole on the valve stem with the hole in the
7. Insert the groove pin into the valve handle and through
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock. Always unplug the
sprayer before servicing!
sure that the problem is corrected. If the sprayer does not
operate properly, review the repair procedure to determine if
everything was done correctly
Charts to help identify other possible problems.
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................1-800-526-5362
housing assembly into the filter block. Tighten securely
with a wrench.
Lubricate the cam base with grease and line up the cam
with the filter block using the dowel pin.
valve handle.
the valve stem to secure the valve handle in position.
. Refer to the Troubleshooting
Replacing the Filters
Pump Filter
1. Loosen and remove the filter
body by hand.
2. Slip the filter off of the core
spring.
3. Inspect the filter. Based on
inspection, clean or replace
the filter.
4. Inspect the o-ring. Based on
inspection, clean or replace
the o-ring.
5. Slide the new or cleaned
filter over the core spring
with the filter spring adapter
in place. Push the filter into
the center of the filter
housing.
6. Slide the filter body over the
filter and thread it into the
filter housing until secure.
NOTE: The filter body
should be handtightened, but make
sure it is seated
fully into the filter
housing.
Gun Filter
1. Move the gun trigger lock to the unlocked position.
2. Loosen and remove the handle from the gun body.
3. Turning clockwise, unscrew the filter from the gun body.
NOTE: Left-handed threads require turning the filter
clockwise to remove.
4. Turning counterclockwise, screw the new or cleaned filter
into the gun body.
5. Make sure the handle seal is in position and thread the
handle into the gun body until secure.
6. Move the gun trigger lock to the locked position.