740ix
Airless Sprayer
NOTE: This manual contains important warnings
and instructions. Please read and retain for reference.
For professional use only
NOTE: This manual contains important warnings
and instructions. Please read and retain for reference.
Model Number:
High Rider Bare 800-1000 High Rider Complete 800-1005 Low Rider Bare 800-1010 Low Rider Complete 800-1015
Page 2
Table of Contents
Safety Precautions.................................................................2
Français ..............................................................................14
Español...............................................................................16
General Description ...............................................................4
Operation ................................................................................4
Setup ....................................................................................4
Preparing to Paint.................................................................4
Painting.................................................................................5
Electronic Pressure Control Indicators .................................5
Pressure Relief Procedure ...................................................5
Spraying ..................................................................................6
Spraying Technique ..............................................................6
Practice.................................................................................6
Cleanup ...................................................................................7
Maintenance............................................................................7
General Repair and Service Notes.......................................7
Replacing the Filters.............................................................8
Replacing the Motor (with Electronic Control)......................8
Replacing the Gears.............................................................9
Replacing the Transducer.....................................................9
Replacing the PRIME/SPRAY Valve...................................10
Servicing the Fluid Section.................................................10
Troubleshooting ...................................................................12
Parts Listings........................................................................18
Main Assembly....................................................................18
Motor Assembly ..................................................................19
Electrical Schematic ...........................................................19
Gear Box Assembly............................................................20
High Rider Cart Assembly ..................................................21
Low Rider Cart Assembly...................................................21
Fluid Section Assembly ......................................................22
Suction Set Assembly, Low Rider.......................................23
Accessories ........................................................................24
Labels .................................................................................24
Warranty................................................................................24
Safety Precautions
This manual contains information that must be read and understood before using the equipment. When you come to an area that has one of the following symbols, pay particular attention and make certain to heed the safeguard.
This symbol indicates a potential hazard that may cause serious injury or loss of life. Important safety information will follow.
This symbol indicates a potential hazard to you or to the equipment. Important information that tells how to prevent damage to the equipment or how to avoid causes of minor injuries will follow.
HAZARD: Injection injury - A high pressure fluid stream
produced by this equipment can pierce the skin and underlying tissues, leading to serious injury and possible amputation. See a physician immediately.
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE CUT! Injection can lead to amputation. See a physician immediately.
The maximum operating range of the sprayer is 3300 PSI/228BAR fluid pressure.
PREVENTION:
• NEVER aim the gun at any part of the body.
WARNING
NOTE: Notes give important information which should
be given special attention.
CAUTION
WARNING
Titan Tool Inc. All rights reserved.
• NEVER allow any part of the body to touch the fluid stream. DO NOT allow body to touch a leak in the fluid hose.
• NEVER put hand in front of the gun. Gloves will not provide protection against an injection injury.
•ALWAYS lock gun trigger, shut pump off, and release all pressure before servicing, cleaning tip or guard, changing tip, or leaving unattended. Pressure will not be released by turning off the motor. The PRIME/SPRAY valve handle must be turned to PRIME to relieve the pressure. Refer to the PRESSURE RELIEF PRESSURE described in the pump manual.
•ALWAYS keep tip guard in place while spraying. The tip guard provides some protection but is mainly a warning device.
•ALWAYS remove the spray tip before flushing or cleaning the system.
• Paint hose can develop leaks from wear, kinking and abuse. A leak can inject material into the skin. Inspect the hose before each use.
• NEVER use a spray gun without a working trigger lock and trigger guard in place.
• All accessories must be rated at or above 3300 PSI/228 BAR. This includes spray tips, guns, extensions, and hose.
HAZARD: EXPLOSION AND FIRE - Solvent and paint
fumes can explode or ignite. Severe injury and/or property damage can occur.
PREVENTION:
• Provide extensive exhaust and fresh air introduction to keep the air within the spray area free from accumulation of flammable vapors.
•Avoid all ignition sources such as static electricity sparks, electrical appliances, flames, pilot lights, hot objects, and sparks from connecting and disconnecting power cords or working light switches.
•Do not smoke in spray area.
• Fire extinguisher must be present and in good working order.
• Place pump at least 20 feet (6.1 m) from the spray object in a well ventilated area (add more hose if necessary). Flammable vapors are often heavier than air. Floor area must be extremely well ventilated. The pump contains arcing parts that emit sparks and can ignite vapors.
• The equipment and objects in and around the spray area must be properly grounded to prevent static sparks.
• Use only conductive or grounded high-pressure fluid hose. Gun must be grounded through hose connections.
• Power cord must be connected to a grounded circuit.
• Always flush unit into separate metal container, at low pump pressure, with spray tip removed. Hold gun firmly against side of container to ground container and prevent static sparks.
• Follow material and solvent manufacturer's warnings and instructions.
• Use extreme caution when using materials with a flashpoint below 70° F (21° C). Flashpoint is the temperature at which a fluid can produce enough vapors to ignite.
• Plastic can cause static sparks. Never hang plastic to enclose spray area. Do not use plastic drop cloths when spraying flammable materials.
• Use lowest possible pressure to flush equipment.
NOTE TO PHYSICIAN: Injection into the skin is a traumatic injury. It is
important to treat the injury as soon as possible. DO NOT delay treatment to research toxicity. Toxicity is a concern with some coatings injected directly into the blood stream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.
Page 3
GAS ENGINE (WHERE APPLICABLE)
Always place sprayer outside of structure in fresh air. Keep all solvents away from engine exhaust. Never fill fuel tank with a running or hot engine. Hot surface can ignite spilled fuel. Always attach ground wire from pump to a grounded object. Refer to engine owner’s manual for complete safety information.
HAZARD: EXPLOSION HAZARD DUE TO INCOMPATIBLE
MATERIALS - will cause severe injury or property damage.
PREVENTION:
• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as bleach, mildewcide, methylene chloride and 1,1,1 ­trichloroethane. They are not compatible with aluminum.
• Contact your coating supplier about the compatibility of material with aluminum.
HAZARD: HAZARDOUS VAPORS - Paints, solvents,
insecticides, and other materials can be harmful if inhaled or come in contact with body. Vapors can cause severe nausea, fainting, or poisoning.
PREVENTION:
• Use a respirator or mask if vapors can be inhaled. Read all instructions supplied with the mask to be sure it will provide the necessary protection.
•Wear protective eyewear.
•Wear protective clothing as required by coating manufacturer.
HAZARD: GENERAL - Can cause severe injury or
property damage.
PREVENTION:
• Read all instructions and safety precautions before operating equipment.
• Follow all appropriate local, state, and national codes governing ventilation, fire prevention, and operation.
• The United States Government Safety Standards have been adopted under the Occupational Safety and Health Act (OSHA). These standards, particularly part 1910 of the General Standards and part 1926 of the Construction Standards, should be consulted.
• Use only manufacturer authorized parts. User assumes all risks and liabilities when using parts that do not meet the minimum specifications and safety devices of the pump manufacturer.
• Before each use, check all hoses for cuts, leaks, abrasion or bulging of cover. Check for damage or movement of couplings. Immediately replace hose if any of those conditions exist. Never repair a paint hose. Replace with a grounded high-pressure hose.
• All hoses, swivels, guns, and accessories must be pressure rated at or above 3300PSI/228 BAR.
• Do not spray outdoors on windy days.
•Wear clothing to keep paint off skin and hair.
• Always unplug cord from outlet before working on equipment.
Grounding Instructions
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER — Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the green grounding wire to either flat blade terminal. The wire with insulation having a green outer surface with or without yellow stripes is the grounding wire and must be connected to the grounding pin.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided. If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the product. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. A 12 gauge cord is recommended. If an extension cord is to be used outdoors, it must be marked with the suffix W­A after the cord type designation. For example, a designation of SJTW-A would indicate that the cord would be appropriate for outdoor use.
CAUTION
©Titan Tool Inc. All rights reserved. 3
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
Page 4
General Description
This airless sprayer is a precision power tool used for spraying many types of materials. Read and follow this instruction manual carefully for proper operating instructions, maintenance, and safety information.
Operation
This equipment produces a fluid stream at extremely high pressure. Read and understand the warnings in the Safety Precautions section at the front of this manual before operating this equipment.
Setup
Perform the following procedure before plugging in the power cord of an electric unit.
1. Ensure that the siphon tube/suction set and the return hose are attached and secure.
2. Using a wrench, attach a minimum of 50’ of 1/4” nylon airless spray hose to the unit. Tighten securely.
3. Attach an airless spray gun to the spray hose. Using two wrenches (one on the gun and one on the hose), tighten securely.
Make sure all airless hoses and spray guns are electrically grounded and rated for at least 3300 psi (228 bar) fluid pressure.
4. Make sure the pressure control knob is in its OFF position in the black zone.
5. Make sure the ON/OFF switch is in its OFF position.
6. Fill the oil cup with one tablespoon of piston seal lubricant (Piston Lube).
Never operate unit for more than ten seconds without fluid. Operating this unit without fluid will cause unnecessary wear to the packings.
7. Make sure the electrical service is 120V, 15 amp minimum.
8. Plug the power cord into a properly grounded outlet at least 25’ from the spray area.
CAUTION
WARNING
NOTE: Do not attach the tip to the spray gun yet.
Remove the tip if it is already attached.
WARNING
Titan Tool Inc. All rights reserved.
Always use a minimum 12 gauge, three-wire extension cord with a grounded plug. Never remove the third prong or use an adapter.
Preparing a New Sprayer
If this unit is new, it is shipped with test fluid in the fluid section to prevent corrosion during shipment and storage. This fluid must be thoroughly cleaned out of the system with mineral spirits before you begin spraying.
Always keep the trigger lock on the spray gun in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn the unit on by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the test fluid out through the return hose and into the waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF position.
Preparing to Paint
Before painting, it is important to make sure that the fluid in the system is compatible with the paint that is going to be used.
Always keep the trigger lock on the spray gun in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate solvent. Examples of the appropriate solvent are water for latex paint or mineral spirits for oil-based paints.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn the unit on by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the old solvent out through the return hose and into the metal waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF position.
CAUTION
NOTE: Incompatible fluids and paint may cause the
valves to become stuck closed, which would require disassembly and cleaning of the sprayer’s fluid section.
CAUTION
CAUTION
Pressure Control
Motor
Circuit
Breaker
Filter
Outlet Fitting
Knob
ON/OFF Switch
Oil Cup
PRIME/ SPRAY Valve
Fluid Section
Return Hose
Siphon Tube
Min. – 1800 PSI
(yellow zone)
(black zone)
OFF
Turbo PulseClean
(red zone)
OFF
(black zone)
Min. PSI
Clean
1800 – 3300 PSI (green zone)
Max. PSI
Pressure Control Knob
Min. PSI
Clean
Max. PSI
Page 5
8. Move the PRIME/SPRAY valve up to the SPRAY position.
9. Turn the unit on.
10. Unlock the gun by turning the gun trigger lock to the unlocked position.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
11.Trigger the gun into the metal waste container until the old solvent is gone and fresh solvent is coming out of the gun.
12. Lock the gun by turning the gun trigger lock to the locked position.
13. Set down the gun and increase the pressure by turning the pressure control knob slowly clockwise into the green zone.
14. Check the entire system for leaks. If leaks occur, follow the “Pressure Relief Procedure” in this manual before tightening any fittings or hoses.
15. Follow the “Pressure Relief Procedure” in this manual before changing from solvent to paint.
Be sure to follow the pressure relief procedure when shutting the unit down for any purpose, including servicing or adjusting any part of the spray system, changing or cleaning spray tips, or preparing for cleanup.
Painting
1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn the unit on by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run until paint is coming through the return hose into the metal waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF position.
8. Remove the return hose from the waste container and place it in its operating position above the container of paint.
9. Move the PRIME/SPRAY valve up to the SPRAY position.
10. Turn the unit on.
11. Unlock the gun by turning the gun trigger lock to the unlocked position.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
12. Trigger the gun into the metal waste container until all air and solvent is flushed from the spray hose and paint is flowing freely. from the gun.
WARNING
WARNING
WARNING
NOTE: Make sure that the spray gun does not have a
tip or tip guard installed.
13. Lock the gun by turning the gun trigger lock to the locked position.
14. Turn the unit off.
15. Attach tip guard and tip to the gun as instructed by the tip guard or tip manuals.
POSSIBLE INJECTION HAZARD. Do not spray without the tip guard in place. Never trigger the gun unless the tip is in either the spray or the unclog position. Always engage the gun trigger lock before removing, replacing or cleaning tip.
16. Turn the unit on.
17. Increase the pressure by turning the pressure control knob slowly clockwise toward the green zone and test the spray pattern on a piece of cardboard. Adjust the pressure control knob until the spray from the gun is completely atomized. Try to keep the pressure control knob at the lowest setting that maintains good atomization.
Electronic Pressure Control Indicators
The following is a description of the indicators on the electronic pressure control.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure when shutting the unit down for any purpose, including servicing or adjusting any part of the spray system, changing or cleaning spray tips, or preparing for cleanup.
1. Lock the gun by turning the gun trigger lock to the locked position.
2. Turn the unit off by moving the ON/OFF switch to the OFF position.
3. Turn the pressure control knob counterclockwise to its OFF position in the black zone.
4. Unlock the gun by turning the gun trigger lock to the unlocked position.
5. Hold the metal part of the gun firmly to the side of a metal container to ground the gun and avoid a build up of static electricity.
6. Trigger the gun to remove any pressure that may still be in the hose.
7. Lock the gun by turning the gun trigger lock to the locked position.
8. Move the PRIME/SPRAY valve down to the PRIME position.
WARNING
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear and additional overspray.
WARNING
©Titan Tool Inc. All rights reserved. 5
Tr igger lock
in locked position.
Min. PSI
Clean
Max. PSI
Tr igger lock
in locked position.
Blinking Yellow = 0 PSI – priming pressure
Solid Yellow = priming pressure – 1800 PSI
Solid Green = 1800 PSI – 3300 PSI
Motor Running Indicator
Programmer Port
Programmer Port
Pressure
Indicator
Dust Cover
Circuit
Breaker
Tr igger lock
in locked position.
Page 6
Spraying
POSSIBLE INJECTION HAZARD. Do not spray without the tip guard in place. Never trigger the gun unless the tip is in either the spray or the unclog position. Always engage the gun trigger lock before removing, replacing, or cleaning tip.
Spraying Technique
The following techniques, if followed, will assure professional painting results.
Hold the gun perpendicular to the surface and always at equal distance from the surface. Depending on the type of material, surface, or desired spray pattern, the gun should be held at a distance of 12 to 14 inches (30 to 35 cm).
Move the gun either across or up and down the surface at a steady rate. Moving the gun at a consistent speed conserves material and provides even coverage. The correct spraying speed allows a full, wet coat of paint to be applied without runs or sags.
Holding the gun closer to the surface deposits more paint on the surface and produces a narrower spray pattern. Holding the gun farther from the surface produces a thinner coat and wider spray pattern. If runs, sags, or excessive paint occur, change to a spray tip with a smaller orifice. If there is an insufficient amount of paint on the surface or you desire to spray faster, a larger orifice tip should be selected.
Maintain uniform spray stroke action. Spray alternately from left to right and right to left. Begin movement of the gun before the trigger is pulled.
Avoid arcing or holding the gun at an angle. This will result in an uneven finish.
Proper lapping (overlap of spray pattern) is essential to an even finish. Lap each stroke. If you are spraying horizontally, aim at the bottom edge of the preceding stroke, so as to lap the previous pattern by 50%.
WARNING
Titan Tool Inc. All rights reserved.
For corners and edges, split the center of the spray pattern on the corner or edge and spray vertically so that both adjoining sections receive approximately even amounts of paint.
When spraying with a shield, hold it firmly against the surface. Angle the spray gun slightly away from the shield and toward the surface. This will prevent paint from being forced underneath.
Shrubs next to houses should be tied back and covered with a canvas cloth. The cloth should be removed as soon as possible. Titan gun extensions are extremely helpful in these situations.
Nearby objects such as automobiles, outdoor furniture, etc. should be moved or covered whenever in the vicinity of a spray job. Be careful of any other surrounding objects that could be damaged by overspray.
Practice
1. Be sure that the paint hose is free of kinks and clear of objects with sharp cutting edges.
2. Turn the pressure control knob counterclockwise to its to its lowest setting.
3. Turn the PRIME/SPRAY valve up to its SPRAY position.
4. Turn the pressure control knob clockwise to its highest setting. The paint hose should stiffen as paint begins to flow through it.
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to check the spray pattern.
8. Use the lowest pressure setting necessary to get a good spray pattern. If the pressure is set too high, the spray pattern will be too light. If the pressure is set too low, tailing will appear or the paint will spatter out in gobs rather than in a fine spray.
Overlap edges
1st
pass
2nd
pass
3rd
pass
4th
pass
5th
pass
start
stroke
pull trigger
Too Thick
Arcing Gun at angle
release
trigger
end stroke
Offspray
Good spray pattern
Paint tailing pattern
Page 7
Cleanup
Special cleanup instructions for use with flammable solvents:
•Always flush spray gun preferably outside and at least one hose length from spray pump.
• If collecting flushed solvents in a one gallon metal container, place it into an empty five gallon container, then flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
The sprayer, hose, and gun should be cleaned thoroughly after daily use. Failure to do so permits material to build up, seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun nozzle tip removed when using mineral spirits or any other solvent to clean the sprayer, hose, or gun. Static electricity buildup may result in a fire or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the Operation section of this manual.
2. Remove the gun tip and tip guard and clean with a brush using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate solvent. Examples of the appropriate solvent are water for latex paint or mineral spirits for oil-based paints.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to its PRIME position.
6. Set the pressure to Turbo PulseClean by turning the pressure control knob to its CLEAN position in the red zone.
7. Turn the unit on by moving the ON/OFF switch to the ON position.
8. Allow the solvent to circulate through the unit and flush the paint out of the return hose into the metal waste container.
9. Turn the unit off by moving the ON/OFF switch to the OFF position.
10. Move the PRIME/SPRAY valve up to its SPRAY position.
11.Turn the unit on.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
12. Trigger the gun into the metal waste container until the paint is flushed out of the hose and solvent is coming out of the gun.
13. Continue to trigger the spray gun into the waste container until the solvent coming out of the gun is clean.
WARNING
WARNING
CAUTION
WARNING
©Titan Tool Inc. All rights reserved. 7
14. Follow the “Pressure Relief Procedure” found in the Operation section of this manual.
15. Unplug the unit and store in a clean, dry area.
Do not store the unit under pressure.
Maintenance
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. Additionally, follow all other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver 3/8" Hex Wrench Needle Nose Pliers 5/16" Hex Wrench Adjustable Wrench 1/4" Hex Wrench Rubber Mallet 3/16" Hex Wrench Flat-blade Screwdriver 5/32” Hex Wrench
1. Before repairing any part of the sprayer, read the instructions carefully, including all warnings.
Never pull on a wire to disconnect it. Pulling on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be sure that the problem is corrected. If the sprayer does not operate properly, review the repair procedure to determine if everything was done correctly. Refer to the Troubleshooting Charts to help identify other possible problems.
3. Make certain that the service area is well ventilated in case solvents are used during cleaning. Always wear protective eyewear while servicing. Additional protective equipment may be required depending on the type of cleaning solvent. Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your TITAN Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................1-800-526-5362
Fax ................................................1-800-528-4826
Customer Service (Canada)..................1-800-565-8665
Fax ................................................ 1-905-856-8496
Customer Service (International)...........1-201-405-7520
Fax ................................................1-201-405-7449
CAUTION
WARNING
CAUTION
NOTE: For long-term or cold weather storage, pump
mineral sprits through the entire system. For short-term storage when using latex paint,
pump water mixed with Titan Liquid Shield through the entire system (see the Accessories section of this manual for part number).
Clean
Min. PSI
Max. PSI
Page 8
Replacing the Filters
Pump Filter
1. Loosen and remove the filter housing by hand.
2. Slip the filter off of the filter support spring.
3. Inspect the filter. Based on inspection, clean or replace the filter.
4. Inspect the o-ring. Based on inspection, clean or replace the o-ring.
5. Slide the new or cleaned filter over the filter support spring with the adapter in place. Push the filter into the center of the pump block.
6. Slide the filter housing over the filter and thread it into the pump block until secure.
Gun Filter
1. Move the gun trigger lock to the unlocked position.
2. Loosen and remove the handle from the gun body.
3. Turning clockwise, unscrew the filter from the gun body.
4. Turning counterclockwise, screw the new or cleaned filter into the gun body.
5. Make sure the handle seal is in position and thread the handle into the gun body until secure.
6. Move the gun trigger lock to the locked position.
NOTE: For more detail, part number information, and
assembly drawings at larger scale, please see the LX -80 Professional Airless Gun Owner's Manual (#313-012).
NOTE: Left-handed threads require turning the filter
clockwise to remove.
NOTE: The filter housing should be hand-tightened,
but make sure the filter housing is seated fully into the pump block.
Titan Tool Inc. All rights reserved.
Replacing the Motor (with Electronic Control)
Electrostatic discharge (ESD) potential could cause damage to electronic control. Use Titan ESD wrist strap P/N 700-1037 or equivalent when working on electronic control with electronic cover removed.
1. Unplug the unit.
2. Loosen and remove the four motor shroud screws. Remove the motor shroud.
3. Release the baffle tape on the side of the baffle assembly and slip the baffle assembly off of the motor. Remove the four baffle spacers.
4. Slide the electronic cover off of the electronic control assembly on the motor.
5. Loosen and remove the four heat sink assembly mounting screws. Pull back the heat sink assembly to access and disconnect the two wires coming from the motor.
6. At the electronic control assembly:
a. Disconnect the white wire coming from the power cord
and the white wire coming from the ON/OFF switch.
b. Disconnect the three wires coming from the
potentiometer and the phone jack-style connector coming from the transducer.
c. Disconnect the seven wires coming from the indicator
lights assembly.
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the gear box housing.
9. With the motor removed, inspect the gears in the gear box housing for damage or excessive wear. Replace the gears, if necessary.
10. Install the new motor into the gear box housing. Make sure the housing gasket is positioned properly.
11.Secure the motor with the four motor mounting screws.
12. Reconnect the wires to the electronic control assembly (refer to the electrical schematic in the Parts List section of this manual).
13. Connect the two motor wires to the heat sink assembly.
14. Position the electronic cover over the electronic control assembly.
15. Position the heat sink assembly on the gear box housing and secure in position with the four heat sink assembly mounting screws
16. Slip the baffle assembly around the motor. Secure the baffle assembly with the baffle tape. Slip the four baffle spacers into position between the rear bell of the motor and the baffle assembly.
17. Slide the motor shroud over the motor. Make sure the housing gasket is positioned properly.
18. Secure the motor shroud with the four motor shroud screws.
WARNING
Filter Housing
Filter Spring
Filter
Adapter
Filter Support Spring
O-Ring
Pump Block
Gun Body
Handle Seal
Filter
Handle
Motor Shroud Screw
Motor Shroud
Electronic Cover
Electronic Control
Assembly
Motor Mounting
Screw
Housing
Gasket
Baffle Assembly
Baffle Tape
Baffle Spacers
Gear Box Housing
Page 9
Replacing the Gears
1. Unplug the unit.
2. Loosen and remove the four motor shroud screws. Remove the motor shroud.
3. Release the baffle tape on the side of the baffle assembly and slip the baffle assembly off of the motor. Remove the four baffle spacers.
4. Slide the electronic cover off of the electronic control assembly on the motor.
5. Loosen and remove the four heat sink assembly mounting screws. Pull back the heat sink assembly to access and disconnect the two wires coming from the motor.
6. At the electronic control assembly: a. Disconnect the white wire coming from the power cord
and the white wire coming from the ON/OFF switch.
b. Disconnect the three wires coming from the
potentiometer and the phone jack-style connector coming from the transducer.
c. Disconnect the seven wires coming from the indicator
lights assembly.
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the gear box housing.
9. Inspect the rotor gear on the end of the motor for damage or excessive wear. If this gear is completely worn out, replace the motor.
10. Remove and inspect the 2nd stage gear assembly for damage or excessive wear. Replace, if necessary.
11. Remove and inspect the crankshaft/gear assembly for damage or excessive wear. If damaged or worn, replace the crankshaft/gear assembly.
12. Install the motor into the gear box housing. Make sure the housing gasket is positioned properly and the thrust washer is in place.
13. Secure the motor with the four motor mounting screws.
14. Reconnect the wires to the electronic control assembly (refer to the electrical schematic in the Parts List section of this manual).
15. Connect the two motor wires to the heat sink assembly.
16. Position the electronic cover over the electronic control assembly.
17. Position the heat sink assembly on the gear box housing and secure in position with the four heat sink assembly mounting screws
18. Slip the baffle assembly around the motor. Secure the baffle assembly with the baffle tape. Slip the four baffle spacers into position between the rear bell of the motor and the baffle assembly.
19. Slide the motor shroud over the motor. Make sure the housing gasket is positioned properly.
20. Secure the motor shroud with the four motor shroud screws.
NOTE: Clean and refill the gear box cavity up to the rear
face of each gear with Lubriplate (P/N 314-171).
Replacing the Transducer
1. Loosen and remove the four front cover screws. Remove the front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston is in its lowest position. Turn off and unplug the sprayer.
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. Additionally, follow all other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
3. Tilt the pump back for easy access to the fluid section.
4. Using a 3/8” hex wrench, loosen and remove the two pump block mounting screws.
5. Pull the pump block down approximately 1/2” from the gear box housing to clear the transducer.
6. Slide the pump block and piston rod forward until the piston rod is out of the T-slot on the slider assembly.
7. Loosen and remove the four heat sink assembly mounting screws.
8. Pull back the heat sink assembly for access to the transducer wire plug-in.
9. Follow the wire from the transducer to the heat sink assembly and unplug the transducer wire from the heat sink assembly.
10. Using an 1/8” hex wrench, loosen and remove the set screw from the bottom of the gear box housing.
11. Slide the transducer assembly out of the bottom of the gear box housing.
12. Install the new transducer assembly into the gear box housing.
13. Thread the set screw into the gear box housing and tighten securely.
14. Plug the transducer wire into the heat sink assembly where the old transducer wire was located.
15. Reassemble the pump by reversing steps 1–8.
Make sure the transducer is aligned properly with the hole in the pump block during reassembly. Improper alignment may cause damage to the transducer gasket.
CAUTION
WARNING
©Titan Tool Inc. All rights reserved. 9
Rotor Gear
Housing Gasket
Thrust Washer
Crankshaft/Gear Assembly
2nd Stage Gear Assembly
Gear Box Housing
Heat Sink Assembly
Heat Sink Assembly
Mounting
Screw
Gear Box
Front
Cover
Front
Cover
Screw
Set Screw
Tr ansducer
Assembly
Housing
T-Slot
Pump Block
Pump Block Mounting Screw
Page 10
Replacing the PRIME/SPRAY Valve
Perform the following procedure using PRIME/SPRAY valve replacement kit P/N 800-915.
1. Push the groove pin out of the valve handle.
2. Remove the valve handle and the cam base.
3. Using a wrench, loosen and remove the valve housing assembly.
4. Make sure the gasket is in place and thread the new valve housing assembly into the pump block. Tighten securely with wrench.
5. Place the cam base over the valve housing assembly. Lubricate the cam base with grease and line up the cam with the pump block using the dowel pin.
6. Line up the hole on the valve stem with the hole in the valve handle.
7. Insert the groove pin into the valve handle and through the valve stem to secure the valve handle in position.
10 ©Titan Tool Inc. All rights reserved.
Servicing the Fluid Section
Use the following procedures to service the valves and repack the fluid section. Perform the following steps before performing any maintenance on the fluid section.
1. Loosen and remove the four front cover screws. Remove the front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston is in its lowest position. Turn off and unplug the sprayer.
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. Additionally, follow all other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
2. For High Rider units, remove the return hose from the clamp on the siphon tube. Unscrew the siphon tube from the foot valve housing.
3. For Low Rider units, remove the retaining clip from the bottom of the foot valve housing. Unscrew the return hose from the pump block and remove the suction set assembly.
5. Tilt the pump back for easy access to the fluid section.
Servicing the Valves
The design of Titan's fluid section allows access to the foot valve and seat as well as the outlet valve and seat without completely disassembling the fluid section. It is possible that the valves may not seat properly because of debris stuck in the foot valve seat or outlet valve seat. Use the following instructions to clean the valves and reverse or replace the seats.
1. Loosen and remove the foot valve housing from the pump block.
2. Remove the lower cage, foot valve ball, foot valve seat, and o-ring from the foot valve housing.
3. Clean out any debris in the foot valve housing and examine the valve housing and seat. If the seat is damaged, reverse or replace the seat.
4. Remove the adapter from the pump block.
5. Using a 3/8” hex wrench, loosen and remove the outlet valve retainer from the piston rod.
6. Remove the upper seal, upper cage, nylon washer, outlet valve ball, and outlet valve seat from the outlet valve retainer.
7. Clean out any debris and examine the outlet valve retainer and outlet valve seat. If the seat is damaged, reverse or replace the seat.
8. Clean and inspect the upper cage and outlet valve ball. Replace if they are worn or damaged.
9. Reassemble the valves by reversing the steps above.
NOTE: During reassembly, make sure the o-ring
between the pump block and foot valve housing is lubricated with grease and in position.
NOTE: Always service the
outlet valve with the piston rod attached to the pump. This will prevent the piston rod from rotating during disassembly of the outlet valve.
Foot Valve Housing
Foot Valve Seat
Foot Valve Ball
Lower Seal
Lower Cage
Adapter
Pump Block
O-Ring
WARNING
Pump Block
Gasket
Dowel Pin
Valve Housing
Assembly
Valve Stem
Cam Base
Valve Handle
Groove Pin
Piston Rod
Upper Seal
Upper Cage
Nylon Washer
Outlet Valve Ball
Outlet Valve Seat
Outlet Valve Retainer
Page 11
Repacking the Fluid Section
©Titan Tool Inc. All rights reserved. 11
NOTE: The factory-installed packings are black in
1. Remove the foot valve assembly using the steps in the
NOTE: The outlet valve does not need to be
2. Using 3/8” a hex
3. Pull the pump
4. Slide the pump
5. Slide the piston
6. Loosen and
7. Remove the upper and lower packings from the pump
8. Clean the pump block.
9. Locate the new upper and lower packings and pack the
10. Insert the upper packing into the
11.Insert the piston guide into the
12. Pre-form the lower packing using the lower packing sizing
13. Insert the lower packing partially
14. Push the lower packing into
15. Inspect the piston rod for wear
color. The replacement packings in the packing replacement kit are white.
“Servicing the Valves” procedure above.
disassembled from the piston rod for this procedure.
wrench, loosen and remove the two pump block mounting screws.
block down approximately 1/2” from the gear box housing.
T-Slot
Tr ansducer
Gasket
Slider Assembly
Retainer Nut
Piston Guide
Upper Packing
block and piston rod forward until the piston rod is out of the T-slot on the slider assembly.
rod out through the bottom of the pump block
Pump Block
Lower Packing
Pump Block Mounting Screw
Piston Rod
remove the retainer nut and piston guide from the pump block.
block.
areas between the packing lips with grease. Lubricate the o-rings on the exterior of the packings with grease.
top of the pump block with the raised lip on the packing facing down.
retainer nut. Thread the retainer nut into the pump block until it is hand tight.
Install upper packing
with raised lip and
o-ring facing down.
O-Ring
Raised Lip
tool (included in the repacking kit).
Closer
into the bottom of the pump block so that the side that has
Top
the o-ring closest to the face of the packing faces up.
position using the lower packing insertion tool (see Fluid Section Assembly parts list for lower packing insertion tool P/N).
Install lower packing with
the side that has the o-ring
closest to the top of the
packing facing up.
and replace if necessary.
17. Insert the piston rod into the bottom of the pump block, through the lower packing, through the upper packing, and out through the retainer nut. Using a rubber mallet, tap the bottom of the piston rod lightly until the piston rod is in position in the pump block.
NOTE: When repacking the fluid section, make sure
the raised lip on the bottom of the lower packing is fully outside the packing around the piston rod after insertion of the piston rod.
18. Remove the piston insertion tool from the top of the piston rod.
19. Using a wrench, tighten the retainer nut into the pump block. Torque to 25-30 ft. lbs.
20. Slide the top of the piston rod into the T-slot on the slider assembly.
21. Position the pump block underneath the gear box housing and push up until it rests against the gear box housing.
CAUTION
Make sure the transducer is aligned properly with the hole in the pump block during reassembly. Improper alignment may cause damage to the transducer gasket.
22. Thread the pump block mounting screws through the pump block and into the gear box housing. Tighten securely.
23. Reassemble the foot valve assembly into the pump block.
NOTE: During reassembly, make sure the o-ring
between the pump block and foot valve housing is lubricated with grease and in position.
24. For High Rider units, thread the siphon tube into the foot valve housing and tighten securely. Make sure to wrap the threads on the siphon tube with PTFE tape before assembly. Replace the return hose into the clamp on the siphon tube.
25. For Low Rider units, insert the elbow on the suction set assembly into the bottom of the foot valve housing. Position the retaining clip up into the foot valve housing to secure the suction set assembly.
26. Thread the return hose into the pump block and tighten securely.
27. Place the front cover on the gear box housing and secure in position using the four front cover screws.
28. Turn on the sprayer by following the procedure in the “Operation” section of this manual and check for leaks.
NOTE: Repacking kit P/N 800-450 is available. For
best results use all parts supplied in this kit.
NOTE: Coat the piston insertion tool and the piston
rod with grease before inserting them into the pump block.
16. Place the piston insertion tool (included in the repacking kit) over the top of the piston rod.
Page 12
Solution
Cause
1. The unit is not plugged in.
2. Tripped breaker.
3. The pressure is set too low (pressure control knob set at minimum setting does not supply power to unit).
4. Faulty or loose wiring.
5. Excessive motor temperature.
6. ON/OFF switch is defective.
1. The PRIME/SPRAY valve is in the SPRAY position.
2. Air leak in the siphon tube/suction set.
3. The pump filter and/or inlet screen is clogged.
4. The siphon tube/suction set is clogged.
1. The spray tip is worn.
2. The spray tip is too large.
3. The pressure control knob is not set properly.
4. The pump filter, gun filter, or inlet screen is clogged.
5. Material flows from the return hose when the PRIME/SPRAY valve is in the SPRAY position.
6. Air leak in the siphon tube/suction set.
7. There is external fluid leak.
8. There is an internal fluid section leak (packings are worn and/or dirty, valve balls are worn).
9. Worn valve seats
10. Motor powers but fails to rotate
1. The upper packings are worn.
2. The piston rod is worn.
Troubleshooting
Problem
The unit will not run.
The unit will not prime.
The unit will not build or maintain pressure.
Fluid leakage at the upper end of the fluid section.
12 ©Titan Tool Inc. All rights reserved.
1. Plug the unit in.
2. Reset the breaker.
3. Turn the pressure control knob clockwise to supply power to the unit and increase the pressure setting.
4. Inspect or take to a Titan authorized service center.
5. Allow motor to cool.
6. Replace the ON/OFF switch.
1. Rotate the PRIME/SPRAY valve clockwise to the PRIME position.
2. Check the siphon tube/suction set connection and tighten or re-tape the connection with PTFE tape.
3. Remove the pump filter element and clean. Remove the inlet screen and clean.
4. Remove the siphon tube/suction set and clean.
1. Replace the spray tip following the instructions that came with the spray gun.
2. Replace the spray tip with a tip that has a smaller orifice following the instructions that came with the spray gun.
3. Turn the pressure control knob clockwise to increase the pressure setting.
4. Remove the pump filter element and clean. Remove the gun filter and clean. Remove the inlet screen and clean.
5. Clean or replace the PRIME/SPRAY valve.
6. Check the siphon tube/suction set connection and tighten or re-tape the connection with PTFE tape.
7. Check for external leaks at all connections. Tighten connections, if necessary.
8. Clean the valves and service the fluid section following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
9. Reverse or replace the valve seats following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
10. Take unit to a Titan authorized service center.
1. Repack the pump following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
2. Replace the piston rod following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
Page 13
©Titan Tool Inc. All rights reserved. 13
Troubleshooting
Problem
Excessive surge at the spray gun.
Poor spray pattern.
The unit lacks power.
Cause
1. Wrong type of airless spray hose.
2. The spray tip worn or too large.
3. Excessive pressure.
1. The spray tip is too large for the material being used.
2. Incorrect pressure setting.
3. Insufficient fluid delivery.
4. The material being sprayed is too viscous.
1. The pressure adjustment is too low.
2. Improper voltage supply.
Solution
1. Replace hose with a minimum of 50’ of 1/4” grounded textile braid airless paint spray hose.
2. Replace the spray tip following the instructions that came with the spray gun.
3. Rotate the pressure control knob counterclockwise to decrease spray pressure.
1. Replace the spray tip with a new or smaller spray tip following the instructions that came with the spray gun.
2. Rotate the pressure control knob to adjust the pressure for a proper spray pattern.
3. Clean all screens and filters.
4. Add solvent to the material according to the manufacturer's recommendations.
1. Rotate the pressure control knob clockwise to increase the pressure setting.
2. Reconnect the input voltage for 120V AC.
Patents
These products are covered by one or more of the following U.S. patents: 4,500,119 4,768,929
Page 14
14 ©Titan Tool Inc. Tous droits réservés.
Consignes de sécurité
Le présent manuel comprend des renseignements devant être lus attentivement avant toute utilisation de l'appareil. Lorsque l'un des symboles suivants apparaît, il est recommandé d'être particulièrement attentif et de tenir compte des mesures de sécurité indiquées.
Ce symbole indique un danger potentiel pouvant causer des blessures graves ou même mortelles. Des renseignements importants sur la sécurité sont également indiqués.
Ce symbole indique un danger potentiel pouvant causer des blessures corporelles ou des dommages à l'équipement. Des renseignements importants sur la façon de prévenir tout dommage à l'équipement ou toute blessure corporelle mineure sont également indiqués.
DANGER: BLESSURES PAR PERFORATION - Le jet de
peinture à haute pression produit par cet appareil peut perforer la peau et les tissus sous-jacents et entraîner de sévères blessures pouvant nécessiter une amputation. Consultez immédiatement un médecin.
NE PAS TRAITER UNE BLESSURE PAR PERFORATION COMME UNE SIMPLE COUPURE! Une perforation peut entraîner des risques d'amputation. Consultez immédiatement un médecin.
Pression de service maximale du fluide dans l’appareil : 3300 lb/po2 / 228BAR.
MESURES PRÉVENTIVES:
• NE JAMAIS diriger le pistolet vers une quelconque partie du corps.
•NE JAMAIS mettre une quelconque partie du corps en contact avec le jet de liquide. NE JAMAIS se mettre au contact d'un jet de liquide provenant d'une fuite du flexible d'alimentation en liquide.
• NE JAMAIS placer votre main devant le pistolet. Des gants ne vous protégeront pas contre les risques de blessures par perforation.
•TOUJOURS verrouiller la gâchette du pistolet, fermer la pompe à liquide et décompresser l'appareil lorsque vous travaillez sur celui-ci, nettoyez le protecteur de tête, remplacez la tête de pulvérisation ou vous éloignez de l'appareil. Couper le moteur ne décompresse pas l'appareil. Vous devez, pour le décompresser, placer le bouton AMORÇAGE/PULVÉRISATION en position AMORÇAGE. Reportez-vous, pour cela, à la PROCÉDURE DE DÉCOMPRESSION décrite dans de ce manuel.
•TOUJOURS s'assurer que le protecteur de tête est en place lorsque vous pulvérisez. Le protecteur de tête offre une certaine protection contre les blessures par perforation mais sa principale fonction est d'ordre préventif.
•TOUJOURS ôter la tête de pulvérisation avant de purger ou nettoyer l'appareil.
• Le flexible d'alimentation en peinture peut fuir à la suite d'une usure, de chocs ou de mauvais traitements. Une fuite peut entraîner une perforation de la peau. Inspecter le flexible avant chaque utilisation.
• NE JAMAIS utiliser un pistolet dont la gâchette n'est pas munie d'un loquet ou un cran de sécurité qui soit en état de fonctionner.
•Tous les accessoires doivent être homologués pour une pression égale ou supérieure à 3300 lb/po2 / 228BAR. Cela s'applique, entre autres, aux têtes de pulvérisation, aux accessoires du pistolet et aux flexibles.
AVERTISSEMENT
NOTA : Les remarques donnent des renseignements
importants requérant une attention particulière.
DANGER: RISQUES D'EXPLOSION OU D'INCENDIE - Les
vapeurs dégagées par le solvant ou la peinture sont explosives et inflammables et peuvent causer des corporels sérieux ou dommages matériels.
MESURES PRÉVENTIVES:
•Veiller à éviter toute accumulation de vapeurs inflammables en vous assurant que la zone où la pulvérisation a lieu est suffisamment ventilée.
•Veiller à éviter la présence de toute source incandescente telle qu'étincelle électrostatique, flamme nue, flamme­pilote, objet brûlant, cigarette et étincelle provenant du branchement ou du débranchement d'un cordon d'alimentation électrique ou d'un commutateur.
• Ne pas fumer dans la zone d’épandage.
•Toujours avoir un extincteur en état de fonctionner à portée de la main.
• Placer la pompe à peinture à une distance d’au moins un mètre (3 pi) (on recommande d’ailleurs une plus grande distance) de l’objet qui doit être vaporisé dans une pièce séparée bien aérée, ou à une distance d’au moins six mètres (20 pi) de celui-ci dans une zone bien aérée (utiliser d’autres tuyaux si nécessaires). Les vapeurs inflammables sont souvent plus lourdes que l’air. Le plancher doit être extrêmement bien aéré. La pompe à peinture contient des pièces pouvant créer des étincelles et enflammer les vapeurs présentes dans l’air.
• Le matériel utilisé, ainsi que les objets se trouvant à proximité de la zone de pulvérisation, doivent être convenablement reliés à la terre afin d'éviter toute étincelle ou toute décharge électrostatique.
• N'utiliser que des flexibles d'alimentation en liquide à haute pression conducteurs ou reliés à la terre dans les cas d'utilisation sans air comprimé. S'assurer que le pistolet est convenablement relié à la terre par l'intermédiaire du flexible.
• Le cordon d’alimentation doit être raccordé à un circuit mis à la terre.
•Toujours purger l’appareil dans un contenant métallique séparé, en s’assurant que la pompe soit à basse pression et que le chapeau soit retiré. Tenir le pistolet fermement contre la paroi du contenant pour mettre celui-ci à la terre et empêcher l’émission d’étincelles causées par l’électricité statique.
• Se conformer aux consignes et recommandations de sécurité du fabricant du solvant ou du produit.
• S’entourer de toutes les précautions possibles lorsqu’on utilise des produits ayant un point d’éclair inférieur à 21 °C (70 °F). Le point d’éclair d’un fluide est la température à laquelle les vapeurs émanant du fluide peuvent s’enflammer au contact d’une flamme ou d’une étincelle.
• Le plastique peut être une source d’étincelles provoquées par l’électricité statique. Ne jamais utiliser une couverture en plastique pour fermer une zone d’épandage ni utiliser des toiles de protection en plastique lors de la pulvérisation de matières inflammables.
• Lorsque vous purgez l'appareil, veillez à utiliser à la pression minimale.
AVERTISSEMENT AUX MÉDECINS : Une perforation sous-cutanée constitue un traumatisme. Il est important de traiter la blessure de façon chirurgicale aussitôt que possible. NE RETARDEZ PAS ce traitement pour des recherches de toxicité. La toxicité n'est un risque que dans les cas où certains produits de revêtement pénètrent dans le flux sanguin. Il peut être nécessaire de faire appel à des soins de chirurgie plastique ou de reconstruction de la main.
Français
AVERTISSEMENT
ATTENTION
Page 15
©Titan Tool Inc. Tous droits réservés. 15
MOTEUR À ESSENCE (DANS LES CAS OÙ CELA S’APPLIQUE)
Toujours placer la pompe à l’extérieur de la structure à l’air frais. Garder tous les solvants loin de l’échappement du moteur. Ne jamais remplir le réservoir à carburant lorsque le moteur est en marche ou lorsqu’il est chaud ; les surfaces chaudes risquent d’enflammer le carburant déversé accidentellement. Toujours raccorder un fil de mise à la terre entre la pompe et un objet mis à la terre, tel qu’une conduite d’eau métallique. Se reporter au guide d’utilisation du moteur pour obtenir de plus amples renseignements concernant la sécurité.
DANGER: RISQUES D'EXPLOSION PAR INCOMPATIBILITÉ
DES MATÉRIAUX - Peuvent être à l'origine de corporels sérieux ou dommages matériels.
MESURES PRÉVENTIVES:
• Ne pas utiliser de matériaux contenant des agents de blanchiment ou du chlore.
• Ne pas utiliser des solvants à base d’hydrocarbure halogéné tels que l’agent anticryptogamique, le chlorure de méthylène et le trichloro-éthane-1,1,1. Ces produits ne sont pas compatibles avec l’aluminium
• Communiquer avec votre fournisseur de revêtement pour connaître la compatibilité du matériau avec l’aluminium.
DANGER: VAPEURS NOCIVES – la peinture, les solvants,
les insecticides et autres matériaux peuvent être nocifs lorsqu’ils sont inhalés ou en contact avec le corps. Les vapeurs peuvent causer une nausée importante, des évanouissements ou un empoisonnement.
MESURES PRÉVENTIVES:
• Utiliser un respirateur ou un masque chaque fois qu'il y a des risques d'inhalation de vapeurs. Lire attentivement toutes les instructions se rapportant au masque pour vérifier que celui-ci vous assure une protection suffisante contre les vapeurs toxiques.
• Porter des lunettes de protection.
• Porter des vêtements de protection, conformément aux directives du fabricant de revêtement.
DANGER: GÉNÉRALITÉS - Peut causer des dommages
matériels ou corporels sérieux.
MESURES PRÉVENTIVES:
•Avant d'utiliser tout équipement, lire attentivement toutes les instructions et les consignes de sécurité
•Toujours débrancher le moteur de l’alimentation électrique avant d’effectuer des travaux sur l’appareil.
• Se conformer à la législation locale, provinciale ou fédérale pour tout ce qui concerne la ventilation, la prévention des incendies et les conditions générales d'utilisation.
• Les normes de sécurité du Gouvernement américain sont régies par le Occupational Safety and Health Act (OSHA). Il est important de consulter ces normes, en particulier la section 1910 sur le normes générales et la section 1926 sur les des normes de la construction.
• N’utiliser que les pièces autorisées par le fabricant. L’utilisateur assume tous les risques et responsabilités lorsqu’il utilise des pièces qui ne sont pas conformes aux caractéristiques techniques minimales ainsi qu’aux dispositifs de sécurité du fabricant de la pompe.
• Vérifier, avant toute utilisation, que les flexibles ne présentent pas d'entaille ou de fuite, que le couvercle ne soit pas gonflé et que les raccords ne soient pas endommagés. Si le flexible a subi l'un des dommages précités, remplacez-le immédiatement. Ne jamais réparer un flexible d'alimentation en peinture. Le remplacer par un autre flexible mis à la terre.
•Tout flexible, raccord orientable, pistolet et accessoire utilisé avec cet appareil doit pouvoir fonctionner à une pression égale ou supérieure à 3300 lb/po2 / 228BAR.
• Ne jamais pulvériser lorsqu'il vente.
• Porter des vêtements pour protéger la peau et les cheveux contre tout contact avec la peinture.
Instructions de mise à la terre
Cet appareil doit être mis à la terre. La mise à la terre réduit les risques d'électrocution lors d'un court-circuit en permettant au courant de s'écouler par le fil de mise à la terre. Cet appareil est muni d'un cordon électrique avec fil de mise à la terre ainsi que d'une fiche de terre. La fiche doit être branchée sur une prise installée correctement et mise à la terre conformément à la réglementation et aux codes en vigueur.
DANGER — Une prise de terre mal branchée peut être à l'origine d'électrocutions. S'il s'avère nécessaire de réparer ou de remplacer le cordon électrique ou la fiche, ne pas brancher le fil vert de mise à la terre sur l'une ou l'autre des bornes à broche plate. Le fil recouvert d'un isolant vert avec ou sans rayures jaunes est le fil de mise à la terre et doit être branché sur la broche de mise à la terre.
Si vous ne comprenez pas les instructions de mise à la terre ou si vous n'êtes pas sûr que l'appareil est correctement mis à la terre, contactez un électricien agréé. Ne pas modifier la fiche d'origine. Si la prise ne convient pas à la fiche, faites installer la prise adéquate par un électricien agréé.
Utiliser uniquement une rallonge à trois fils munie d'une fiche de terre dans une prise secteur mise à la terre correspondant au type de fiche de l'appareil. S'assurer que votre rallonge est en bon état. Lorsque vous utilisez une rallonge, assurez-vous qu'elle soit d'un calibre suffisant pour supporter l'intensité du courant requise par l'appareil. Une rallonge trop mince entraîne une chute de tension, une diminution de l'intensité et une surchauffe. Une rallonge de calibre 12 est recommandée. Si vous devez utiliser une rallonge à l’extérieur, celle-ci doit comprendre la marque W­A après la désignation indiquant le type de cordon. Par exemple, la désignation SJTW-A indique que le cordon est conçu pour être utilisé à l’extérieur.
ATTENTION
Français
Prise de terre
Goupille de mise à la terre
Couvercle du boîtier de prise de terre
Page 16
Español
16 ©Titan Tool Inc. Todos los derechos reservados.
Precauciones de seguridad
Este manual contiene información que debe leer y comprender antes de usar el equipo. Cuando se encuentre con uno de los siguientes símbolos, asegúrese de observar sus indicaciones de seguridad.
Este símbolo indica la existencia de un peligro potencial que puede causar lesiones graves o la muerte. Después del mismo se incluye información de seguridad importante.
Este símbolo indica la existencia de un peligro potencial para usted o el equipo. Después del mismo se incluye información importante que indica la forma de evitar daños al equipo o la forma de prevenir lesiones menores.
PELIGRO: LESIÓN POR INYECCIÓN - La corriente de
pintura de alta presión que produce este equipo puede perforar la piel y tejidos subyacentes, lo que conduciría a lesiones serias y una posible amputación. Consulte de inmediato a un médico.
NO TRATE LAS LESIONES POR INYECCIÓN COMO SI FUERAN SIMPLES CORTADAS! Una inyección puede conducir a una amputación. Consulte de inmediato a un médico.
El rango de operación máximo de la unidad es 3300 PSI / 228BAR de presión de fluidos.
PARA PREVENIR:
• NO dirija NUNCA la punta de la pistola hacia alguna parte del cuerpo.
• NO permita NUNCA que alguna parte del cuerpo tenga contacto con la corriente del fluido. EVITE tener contacto con corrientes de fluido que salgan de fugas que haya en la manguera.
• NO ponga NUNCA la mano enfrente de la manguera. Los guantes no ofrecen ninguna protección contra lesiones por inyección.
• Bloquee SIEMPRE el gatillo de la pistola, apague la bomba de fluido y libere toda la presión antes de dar mantenimiento, limpiar el protector de la boquilla, cambiar la boquilla o dejar desatendido el equipo. La presión no se liberará al apagar el motor. Para liberar la presión debe girarse la perilla PRIME/SPRAY (cebar/atomizar) hasta la posición PRIME. Consulte el PROCEDIMIENTO PARA LIBERAR LA PRESIÓN que se describe en este manual.
• Mantenga puesto SIEMPRE el protector de la boquilla mientras atomice. El protector de la boquilla ofrece cierta protección contra lesiones por inyección pero es principalmente un dispositivo de advertencia.
• Quite SIEMPRE la boquilla del atomizador antes de enjuagar o limpiar el sistema.
• Pueden desarrollarse fugas en la manguera de pintura por causa del desgaste, retorcimientos o el abuso. Una fuga es capaz de inyectar el material en la piel. Cada vez que use la manguera de pintura, inspecciónela antes.
• NO use nunca una pistola de atomización que no tenga un bloqueador o un protector de gatillo puesto y que funcione.
•Todos los accesorios deben tener una capacidad de 3300 lb/pulg2 / 228BAR o mayor. Esto incluye las boquillas de atomizador, pistolas, extensiones y mangueras.
NOTA: los avisos contienen información importante,
présteles especial atención.
PELIGRO: EXPLOSIÓN O INCENDIO - Los vapores de
solventes y pintura pueden explotar o incendiarse, causando con esto lesiones severas y/o daños en la propiedad.
PARA PREVENIR:
• Debe proveerse un escape y aire fresco para hacer que el aire que está dentro del área de atomización se mantenga libre de acumulaciones de vapores inflamables.
• Evite todas las fuentes de ignición como son las chispas electrostáticas, llamas abiertas, flamas de piloto, objetos calientes, cigarros, y chispas que se generan al conectar y desconectar las extensiones o de apagadores de luz que estén funcionando.
• No fume en la zona de trabajo.
• Debe haber un equipo para extinguir incendios permanentemente y en buenas condiciones.
• Coloque la bomba para pintar a un mínimo de 1 m (de preferencia más) en una habitación aparte, bien ventilada, alejada del objeto que va a pintar o a por lo menos 6 m de dicho objeto, en una zona bien ventilada (utilice una manguera más larga, si es necesario). Los gases inflamables a menudo son más pesados que el aire. La zona del piso debe tener la debida ventilación. La bomba para pintar contiene piezas que forman arcos que emiten chispas y pueden encender los gases.
• El equipo que se utilice, así como los objetos que estén dentro y alrededor del área de atomización, deben conectarse a tierra de manera apropiada para prevenir las descargas eléctricas y las chispas.
• Use solamente mangueras para fluidos de alta presión, conductoras o conectadas a tierra, para aplicaciones sin aire. Asegúrese de que la pistola esté conectada a tierra de manera apropiada, mediante conexiones de manguera.
• El cable de alimentación debe enchufarse a un circuito aterrado.
• Siempre enjuague la unidad en un recipiente de metal por separado, con presión baja en la bomba y sin la boquilla. Sostenga la pistola firmemente contra el recipiente para ponerlo a tierra y evitar chispas estáticas.
• Siga las advertencias y avisos de seguridad del fabricante de los materiales y solventes.
•Tenga muchísimo cuidado al usar materiales cuyo punto de ignición sea inferior a 70° F (21° C). El punto de ignición es la temperatura a la cual pueden encenderse los vapores emanados por un fluido al exponerlos a llamas o chispas.
• El plástico puede causar chispas estáticas. Nunca cuelgue plástico en las ventanas ni en las puertas del área donde va a pintar. No utilice plástico para proteger el piso cuando pinte materiales inflamables.
• Cuando enjuague el equipo utilice la presión más baja posible.
MOTOR DE GAS (SEGÚN CORRESPONDA)
Coloque siempre la bomba fuera del edificio, al aire libre. Mantenga todo solvente alejado del escape del motor. Nunca llene el tanque de combustible si el motor está encendido o caliente. La superficie caliente puede encender el combustible derramado. Conecte siempre un conductor de tierra desde la unidad de la bomba a un objeto puesto a tierra, por ejemplo una tubería de agua metálica. Consulte el manual del motor para obtener información completa de seguridad.
NOTA PARA EL MÉDICO: La inyección dentro de la piel es una lesión traumática. Es importante que la lesión se trate quirúrgicamente tan pronto como sea posible . NO retrase el tratamiento por investigar la toxicidad. La toxicidad es motivo de preocupación con algunos revestimientos que se inyectan directamente en la corriente sanguínea. Es recomendable consultar a un cirujano plástico o reconstructor de manos.
ADVERTENCIA
PRECAUCION
ADVERTENCIA
Page 17
©Titan Tool Inc. Todos los derechos reservados. 17
PELIGRO: PELIGRO DE EXPLOSIÓN DEBIDO A
MATERIALES INCOMPATIBLES - Podría causar lesiones severas o daños en la propiedad.
PARA PREVENIR:
• No utilice materiales que contengan blanqueador o cloro.
• No use solventes con hidrocarburos halogenados, tales como productos para eliminar el moho, cloruro de metileno y 1,1,1 - tricloroetano. Estos no son compatibles con el aluminio.
• Comuníquese con el proveedor del producto para obtener información de compatibilidad con materiales de aluminio.
PELIGRO: GASES PELIGROSOS - Las pinturas, solventes,
insecticidas y otros materiales pueden ser perjudiciales si se inhalan o entran en contacto con el cuerpo. Los gases pueden causar náusea, desmayos o envenenamiento graves.
PARA PREVENIR:
• Use una mascarilla respiratoria o careta siempre que exista la posibilidad de que se puedan inhalar vapores. Lea todas las intrucciones que vengan con la careta para estar seguro de que se tendrá la protección necesaria contra la inhalación de vapores dañinos.
• Use gafas protectoras.
• Use ropa de protección, según lo requiera el fabricante del producto.
PELIGRO: GENERAL - Puede causar daños en la
propiedad o lesiones severas.
PARA PREVENIR:
• Lea todas las instrucciones y advertencias de seguridad antes de hacer funcionar cualquier equipo.
• Desconecte siempre el motor del suministro eléctrico antes de dar servicio al equipo.
• Observe todos los códigos locales, estatales y nacionales apropiados que rigen las medidas de ventilación, prevención de incendios y operación.
• Los Estándares de Seguridad del Gobierno de los Estados Unidos se han adoptado bajo el Acta de Seguridad y Salud Ocupacionales (OSHA por sus siglas en inglés). Deben consultarse estos estándares, particularmente la parte 1910 de los Estándares Generales y la parte 1926 de los Estándares de la Construcción.
• Utilice únicamente piezas autorizadas por el fabricante. El usuario asume todos los riesgos y responsabilidades si usa piezas que no cumplen con las especificaciones mínimas y dispositivos de seguridad del fabricante de la bomba.
• Antes de usarla cada vez, revise todas las mangueras para ver que no tengan cortadas, fugas, una cubierta desgastada por abrasión o con abolladuras, así como uniones dañadas o que se hayan movido. Si existiera cualquiera de estas condiciones, reemplace la manguera inmediatamente. No repare nunca una manguera de pintura. Reemplácela con otra manguera conectada a tierra.
•Todas las mangueras, soportes giratorios, pistolas y accesorios que se usen con esta unidad deben tener una capacidad de presión de 3300 lb/pulg2 / 228 BAR o mayor.
• No atomice en días con viento.
• Use ropa que evite el contacto de la pintura con la piel y el cabello.
Español
Instrucciones para conectar a tierra
Este producto se debe conectar a tierra. En caso de que ocurra un corto circuito, la conexión a tierra reduce el riesgo de choque eléctrico al proporcionar un alambre de escape para la corriente eléctrica. Este producto está equipado con un cable que tiene un alambre de conexión a tierra con un enchufe de conexión a tierra apropiado. El enchufe se debe enchufar en una toma de corriente que se haya instalado y conectado a tierra debidamente, de acuerdo con todos los códigos y estatutos locales.
PELIGRO — Una instalación inapropiada del enchufe de conexión a tierra puede dar como resultado el que exista un riesgo de choque eléctrico. Si es necesario reparar o reemplazar el cable o el enchufe, no conecte el alambre de conexión a tierra a ninguno de los terminales de hoja planos. El alambre con aislamiento que tiene la superficie exterior de color verde con franjas amarillas o sin ellas es el alambre de conexión a tierra que debe conectarse al conector de conexión a tierra.
Verifique con un electricista o técnico de servicio calificado si las instrucciones para conectar a tierra no le han quedado completamente claras, o si duda que el producto haya quedado conectado a tierra de manera apropiada. No modifique el enchufe que se proporciona. Si el enchufe no entra en la toma de corriente, pídale a un electricista calificado que instale la toma apropiada.
Use solamente extensiones trifilares que tengan un enchufe de conexión a tierra de 3 hojas y un receptáculo de triple ranura que acepte el enchufe del producto. Asegúrese de que su extensión esté en buenas condiciones. Cuando use una extensión, asegúrese de usar una que sea lo suficientemente resistente como para soportar la corriente que descargue su producto. Un cable de un tamaño menor causará una caída de voltage en la línea que dará como resultado una pérdida de energía y un sobrecalenta|ôento. Se recomienda usar un cable de calibre 12. Si se utiliza un cable de extensión en el exterior, tiene que estar marcado con el sufijo W-A después de la designación del tipo de cable. Por ejemplo, SJTW-A para indicar que el cable es apropiado para uso en exteriores.
PRECAUCION
Tomacorriente aterrado
Terminal de tierra
Tapa de la caja del tomacorriente aterrado
Page 18
18 © Titan Tool Inc. All rights reserved.
Parts List
Main Assembly
Item Part # Description Quantity
1 800-570 High Rider cart assembly ...........................1
2 ---------- Gear box assembly (see separate listing)..1 3 ---------- Fluid section assembly
(see separate listing) ..................................1
4 763-552 Lock washer................................................2
5 710-033 Screw ..........................................................2
6 704-304 Pail hook .....................................................1
7 730-334 Hose clamp.................................................1
Item
Part # Description Quantity
8 705-054 Siphon tube (High Rider) ............................1
9 710-046 Inlet screen, 10 mesh (High Rider).............1
10 704-117 Screw..........................................................2
11 ---------- Motor assembly (see separate listing)........1
12 761-178 Screw..........................................................4
13 800-915 PRIME/SPRAY valve assembly..................1
14 702-239 Return hose (High Rider)............................1
1
2
3
11
4
5
6
7
8
9
10
12
13
3
14
Page 19
©Titan Tool Inc. All rights reserved. 19
Motor Assembly
Item Part # Description Quantity
1 800-465 Motor shroud...............................................2
2 705-063 Electronic cover ..........................................1
3 700-681 Screw ..........................................................4
4 800-211 Motor assembly, 120V
(includes items 5 and 9–11) .......................1
5 800-209 Front end bell assembly w/bearings ...........1
6 704-331 Housing gasket ...........................................1
7 704-181 Screw ..........................................................4
Item
Part # Description Quantity
8 704-332 Screw grommet...........................................4
9 800-213 Electronic control assembly, 120V..............1
10 800-215 Fan shroud..................................................1
11 800-294 Fan assembly .............................................1
12 800-427 Baffle assembly ..........................................1
13 800-416 Baffle tape...................................................1
14 800-439 Baffle spacer...............................................4
Electrical Schematic
NOTE: All electrical work should be
performed by a Titan authorized service center.
1
2
3
7
8
4
5
6
Plug
Potentiometer
800-461
9
10
11
12
13
14
Transducer
800-101
Power Cord
800-079 (HR)
800-029 (LR)
Chassis
Ground
WHITE
GREEN
Wire Assembly 765-072
Circuit Breaker 765-327
BLACK
Switch
780-380
WHITE
Electronic
Control Assy
BLACK
#1 #2
#4 #5
WHITE
Chassis
YELLOW PURPLE
GRAY BLUE
RED WHITE BLACK
Motor
Indicator Lights Assembly
Page 20
20 © Titan Tool Inc. All rights reserved.
Gear Box Assembly
1
3
4
5
10
11
12
2
8
9
6
7
15
16
17
18
2
13
14
19
20
Page 21
©Titan Tool Inc. All rights reserved. 21
Item Part # Description Quantity
1 800-464 Front cover w/label .....................................1
2 700-139 Screw ..........................................................8
3 704-173 Crankshaft/gear assembly ..........................1
4 704-174 Thrust washer .............................................1
5 704-176 2nd stage gear............................................1
6 800-067 Gear box housing .......................................1
7 704-301 Slider assembly ..........................................1
8 700-175 Cap .............................................................1
9 700-176 Seal.............................................................1
10 700-159 Pressure control knob.................................1
11 800-274 Potentiometer mount ..................................1
Item
Part # Description Quantity
12 800-079 Power cord assembly (high rider)...............1
800-029 Power cord assembly (low rider)
13 704-229 Screw..........................................................1
14 800-101 Transducer assembly .................................1
15 800-461 Potentiometer .............................................1
16 704-380 ON/OFF switch ...........................................1
17 765-327 Circuit breaker ............................................1
18 710-127 Set screw....................................................1
19 800-460 Heat sink assembly
(includes item 21) .......................................1
20 704-281 Port plug .....................................................1
High Rider Cart Assembly (P/N 800-570)
Item Part # Description Quantity
1 800-463 Handle
(includes items 2–6 and 11 ........................1
2 590-506 Washer........................................................2
3 590-508 Roll pin........................................................2
4 590-504 Sleeve .........................................................2
5 856-921 Screw ..........................................................4
6 856-002 Washer........................................................4
7 704-291 Roll pin........................................................2
8 704-354 Spacer ........................................................2
9 704-355 Cap .............................................................2
10 800-462 Frame (includes items 13 and 15)..............1
11 590-507 Snap button ................................................2
12 761-178 Hex head screw..........................................4
13 710-199 Plug.............................................................2
14 800-593 Wheel..........................................................2
15 335-018 Plug.............................................................2
9
10
8
7
2
3
5 6
4
1
11
15
13
14
12
Low Rider Cart Assembly (P/N 705-200)
Item Part # Description Quantity
1 704-307 Mounting bracket ........................................2
2 763-549 Hex lock nut ................................................2
3 856-921 Screw ..........................................................4
4 856-002 Washer........................................................4
5 704-291 Roll pin........................................................2
6 800-468 Wheel..........................................................2
7 704-355 Cap .............................................................2
8 800-470 Frame (includes items 9 and 11)................1
9 700-674 Cap .............................................................2
10 763-549 Lock nut ......................................................2
11 335-018 Plug.............................................................2
12 590-508 Roll pin........................................................2
13 590-506 Washer........................................................2
14 704-188 Screw..........................................................1
15 773-918 Screw..........................................................2
16 700-1041 Drip cup ......................................................1
17 756-091 Hex head screw..........................................4
18 590-504 Sleeve.........................................................2
19 590-507 Snap button ................................................2
20 800-469 Handle assembly
(includes items 1, 3, 4, 12, 13, 18, and 19)...1
21 704-354 Wheel spacer (not shown)..........................4
1 2 3 4 5 6
7
8
9 10 11
12 13
14
15 16 17
18 19
20
Page 22
22 © Titan Tool Inc. All rights reserved.
Fluid Section Assembly
NOTE: When repacking the fluid section, make
sure the raised lip on the bottom of the lower packing is fully outside the packing around the piston rod after insertion of the piston rod.
NOTE: When using “HOT” solvents, replace Viton o-ring (item 36) with optional PTFE o-ring (P/N 700-897). Install with o-ring tool (P/N 700-890).
Install upper packing
with raised lip and
o-ring facing down.
O-Ring
Raised Lip
24
3
4
5
6
37
30
38
39
40
41
31
32
33
7
34
35
36
8
25
26
27
28
29
9
42 43
1
10
Closer
Top
11
12
2
13
14
15
Install lower packing with
the side that has the o-ring
closest to the top of the
packing facing up.
16
17
18
19
20
21
22
23
Page 23
©Titan Tool Inc. All rights reserved. 23
Item Part # Description Quantity
Suction Set Assembly, Low Rider (P/N 704-300)
1
3
6
2
4
5
7
Item Part # Description Quantity
1 704-263 Return hose assembly ................................1
2 704-121 O-ring ..........................................................2
704-109 O-ring (for hot solvents, optional)
3 700-1024 Elbow ..........................................................1
4 704-127 Retaining clip ..............................................1
5 700-1023 Siphon hose
(includes items 2–4, and 7) ........................1
6 755-135 Clip..............................................................1
7 700-805 Inlet screen .................................................1
1 800-458 Fluid section, High Rider
(excludes items 24–41) ..............................1
800-466 Fluid section, Low Rider
(excludes items 24–41)
2 800-451 Piston assembly (includes items 10–16) ....1
3 705-104 Retainer nut ................................................1
4 705-105 Piston guide ................................................1
5 800-454 Upper packing assembly ............................1
6 227-028 Plug.............................................................1
7 800-453 Pump block (includes item 6) .....................1
8 227-006 Outlet fitting.................................................1
9 800-456 Lower packing assembly ............................2
10 800-452 Piston rod....................................................1
11 800-348 Upper seal ..................................................1
12 800-441 Upper cage .................................................1
13 800-245 Nylon washer..............................................1
14 800-247 Outlet valve ball ..........................................1
15 800-243 Outlet valve seat.........................................1
16 800-336 Outlet valve retainer ...................................1
17 705-103 Adapter .......................................................1
18 800-442 Lower cage .................................................1
19 800-242 Foot valve ball ............................................1
20 800-241 Foot valve seat ...........................................1
21 762-058 O-ring..........................................................1
22 762-103 Lower seal ..................................................1
23 705-106 Foot valve housing (High Rider).................1
705-141 Foot valve housing (Low Rider)
24 704-252 Filter housing ..............................................1
25 730-067 Filter............................................................1
26 730-083 Filter spring.................................................1
Item
Part # Description Quantity
27 702-251 Adapter .......................................................1
28 757-105 Filter support spring....................................1
29 704-297 O-ring..........................................................1
30 800-915 PRIME/SPRAY valve assembly
(includes items 31—43)..............................1
31 700-537 Gasket ........................................................1
32 221-012 O-ring, Viton................................................1
33 222-012 O-ring, PTFE ..............................................1
34 700-253 Valve housing .............................................1
35 800-910 Valve seat...................................................1
36 700-721 O-ring, Viton................................................1
700-897 O-ring, PTFE (optional)
37 700-750 Valve stem..................................................1
38 800-926 Spring .........................................................1
39 700-248 Valve retainer..............................................1
40 700-251 Cam base ...................................................1
41 700-697 Valve handle...............................................1
42 700-759 Groove pin ..................................................1
43 700-823 Dowel pin....................................................1
44 704-273 Fitting (Low Rider only, not shown)............1
800-459 Fluid section complete, high rider
(includes items 1–43)
800-467 Fluid section complete, low rider
(includes items 1–44)
800-450 Repacking kit (includes items 4, 5, 9, 11,
13, 14, 17, 19, and 20–22, as well as packing grease P/N 700-203 and lower packing insertion tool P/N 705-138)
705-138 Lower packing insertion tool .......................1
Page 24
24 © Titan Tool Inc. All rights reserved.
Warranty
Material Safety Data Sheets (MSDS) are available on Titan’s website or by calling Customer Service.
Titan Tool, Inc., (“Titan”) warrants that at the time of delivery to the original purchaser for use (“End User”), the equipment covered by this warranty is free from defects in material and workmanship. With the exception of any special, limited, or extended warranty published by Titan, Titan’s obligation under this warranty is limited to replacing or repairing without charge those parts which, to Titan’s reasonable satisfaction, are shown to be defective within twelve (12) months after sale to the End User. This warranty applies only when the unit is installed and operated in accordance with the recommendations and instructions of Titan.
This warranty does not apply in the case of damage or wear caused by abrasion, corrosion or misuse, negligence, accident, faulty installation, substitution of non-Titan component parts, or tampering with the unit in a manner to impair normal operation.
Defective parts are to be returned to an authorized Titan sales/service outlet. All transportation charges, including return to the factory, if necessary, are to be borne and prepaid by the End User. Repaired or replaced equipment will be returned to the End User transportation prepaid.
THERE IS NO OTHER EXPRESS WARRANTY. TITAN HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING, BUT NOT LIMITED TO, THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, TO THE EXTENT PERMITTED BY LAW. THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD SPECIFIED IN THE EXPRESS WARRANTY. IN NO CASE SHALL TITAN LIABILITY EXCEED THE AMOUNT OF THE PURCHASE PRICE. LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
TITAN MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY TITAN. THOSE ITEMS SOLD, BUT NOT MANUFACTURED BY TITAN (SUCH AS GAS ENGINES, SWITCHES, HOSES, ETC.) ARE SUBJECT TO THE WARRANTY, IF ANY, OF THEIR MANUFACTURER. TITAN WILL PROVIDE THE PURCHASER WITH REASONABLE ASSISTANCE IN MAKING ANY CLAIM FOR BREACH OF THESE WARRANTIES.
Accessories
Airless Tip Selection
Tips are selected by the orifice size and fan width. The proper selection is determined by the fan width required for a specific job and by the orifice size that will supply the desired amount of fluid and accomplish proper atomization.
For light viscosity fluids, smaller orifice tips generally are desired. For heavier viscosity materials, larger orifice tips are preferred. Please refer to the chart below.
The following chart indicates the most common sizes and the appropriate materials to be sprayed.
Fan widths measuring 8" to 12" (20 to 30 cm) are preferred because they offer more control while spraying and are less likely to plug.
Liquid Shield Plus
Cleans and protects spray systems against rust, corrosion and premature wear. Now with -25º anti-freeze protection.
Part #
Description
314-483...........4 ounce bottle
314-482...........1 quart bottle
Tip Size Spray Material Filter Type
.011 — .013 Lacquers and stains 100 mesh filter
.015 — .019 Oil and latex 60 mesh filter
.021 — .026 Heavy bodied latex and blockfillers 30 mesh filter
NOTE: Do not exceed the sprayer's recommended
maximum tip size.
Piston Lube
Specially formulated to prevent materials from adhering to the piston rod, which becomes abrasive to the upper seals. Piston Lube will break down any material that may accumulate in the oil cup and keep it from drying.
Part #
Description
314-481...........4 ounce bottle
314-480...........8 ounce bottle
Miscellaneous
Part #
Description
490-012...........Hose coupling, 1/4" x 1/4"
730-397...........High pressure fluid Gauge
314-171...........Lubriplate, 14 ounce individual
314-172...........Lubriplate, 6 lb. can
700-1037..........Electrostatic discharge (ESD) wrist strap
Labels
Part #
Description
313-1691 740i logo label 313-1673 Warning label
(injection/explosion) 313-1847 Shock hazard label 313-1715 Pressure control knob label 313-1743 Indicator lights label 313-1638 “Titan” front label 313-1906 Infinity logo label
United States Sales & Service
1-800-526-5362
Fax 1-800-528-4826
107 Bauer Drive
Oakland, NJ 07436
www.titantool.com
Canadian Branch
1-800-565-8665
Fax 1-905-856-8496
200 Trowers Road, Unit 7B
Woodbridge, Ontario L4L 5Z8
International
1-201-337-1240
Fax 1-201-405-7449
107 Bauer Drive
Oakland, NJ 07436 USA
Loading...