Water heater mounting methods
Water heater mounting
Connection to water main
Connection to electric main
8. Water heater operation
9. Maintenance
10. Troubleshooting
11. Wiring diagram
Dear customer!
Thank you for your good choice. You purchased TIMBERK
2
electric storage water heater with an enameled internal tank. It
will serve you for a long time!
3
3
TIMBERK electric storage water heaters will provide a lot
of hot water and will automatically maintain the specified
3
temperature. They are perfect to provide hot water for country
4
houses, cottages, baths and other standalone amenity rooms.
4
5
5
6
6
Please, read this operation manual carefully prior to use of the water heater.
6
This operation manual contains important information regarding your
7
safety, as well as recommendations on the proper operation of the unit and
its maintenance.
8
Save this operation manual together with the guarantee card, cash register
9
receipt, if possible, cardboard box and packing material.
9
Different types of this device are described in this manual.
10
The purchased water heater can slightly differ from the one, described in
11
the manual, but that doesn’t affect methods of its use and operation.
11
1. IMPORTANT INFORMATION
IMPORTANT!
Important precautions and instructions, contained in
this manual, do not account for all possible modes and
situations to be encountered. It is vital to understand
that common sense, caution and thoroughness are the
factors that are impossible to be built-in in any product.
These factors must be taken into consideration by
a person, interested in proper operation of the unit.
The manufacturer does not bear any responsibility in
case when the unit or its parts are damaged during
transportation, as a result of improper installation,
voltage fluctuations, as well as if some part of the unit
was altered or modified.
2
www.timberk.com • electrical storage water heater
2. PRECAUTIONS
Certain precautions are to be observed upon use of the water heater. Improper use due to ignoring precautions may harm health of the user and
other people as well as damage their property.
1. Any electrical appliance must be under control upon its use, especially if
there are children nearby. Make sure children do not touch the appliance.
2. Prior to installation of the water heater, not connecting it to the electrical main, check and make sure that the outlet for the water heater has a
ground contact and it is properly earthed. If there is no earth loop in your
electrical main then using of the water heater will be dangerous for your life.
3. Connect the water heater only to 220V / 50Hz electrical main. If necessary, find out parameters of your main at power suppliers.
4. To prevent overheating and risk of fire as well as damage of inner electrical main do not modify the power cord’s length and do not connect the
water heater through power extension cord.
5. It is forbidden to switch on the water heater if it is not filled with water or
if water cannot go through the pressure safety valve.
6. Never use the water heater if it is damaged.
7. Do not remove the water heater cover when it is in operation.
8. Immediately unplug the water heater from the electrical main if strange
sounds, odour or smoke comes out from it.
9.Always unplug the water heater from the electrical main during thunderstorm.
10. Prior to cleaning and maintenance of the water heater unplug it from
the electrical main every time. Cleaning and maintenance must be performed in compliance with the instructions contained in this manual.
11. Do not use hazardous chemical substances to clean the water heater
and prevent their contact with the appliance.
12. To prevent electrical shock the damaged power cord must be replaced
only by qualified specialists in manufacturer’s authorized service centres.
13. To prevent electrical shock do not place the power cord nearby heating
devices and flammable or combustible agents.
14. As temperature of water in the water heater can reach 75°C when it is
in operation you should not place your body parts under hot water upon
the first run. To prevent burns you should adjust the temperature of the
outflowing water.
15. Do not use the water heater for purposes not stipulated in this instruc-
tion manual.
16. Do not use the water heater in an explosive or corrosive environment.
Do not store petrol and any other volatile flammable liquids near to the
appliance. It is very dangerous!
17. It is forbidden to make alterations in the design of the water heater or
modify it.
18. Any service works must be performed by a specialized organisation
and qualified specialists. Improper installation may cause voiding of guarantee maintenance.
19. The water heater is not intended for use by children and persons with
reduced physical, sensory or mental capabilities, or a lack of experience
and knowledge unless they are under supervision or instructed on using of
the appliance by a person responsible for their safety. Children should be
controlled to ensure that they do not play with the appliance.
3. APPLICATION OF WATER HEATER
Electric water heater is used to heat cold water from water supply. Unit is
for household use.
4. PERFORMANCE PARAMETERS
1. Completely automatic control: automatic water heating, continuous automatic water temperature control.
2. DROP Defense – leakage protection and protection against surplus pres-
sure within a tank (pressure safety valve).
HOT Defense – two-stage overheating protection (thermostat and temperature limiter).
ALL PROTECTION SYSTEMS ARE RELIABLE AND SAFE.
3. Steel internal tank with a special titanium fine glass enamel coating,
applied by the modern electrostatic dry enameling method, is resistant to
corrosion and scale. Also enamel has an increased adhesive capability and
high ductility (hardened at 850°C), which allows it to expand and contract at
temperature drops in the same ratio as the internal tank walls not generating
microcracks, where corrosion may emerge.
4. Pipes of heating elements are designed taking into account high heat load:
safe and reliable, with an increased service life.
www.timberk.com • electrical storage water heater
3
5. The water heater is equipped with an anode bar to protect the internal
tank from corrosion and decrease scale generation on the heating element.
6.Internal thickened urethane foam insulation allows to efficiently preserve
temperature of the heated water and minimize heat losses, reducing power
consumption of the water heater.
7. The water heater has simple structure and is convenient in service.
Technical characteristics
Technical characteristics of water heaters are given below in Table 1.
Table 1
DescriptionUnitsRE11 30 VRE11 50 VRE11 80 VRE11 100 V
Power supplyV/Hz220~/50220~/50220~/50220~/50
Rated currentA6,86,86,86,8
Nominal power
consumption
Tank capacityL305080100
Rated pressureMpa0,80,80,80,8
Water protection–IPX4IPX4IPX4IPX4
Heating time, at
Constant daily heating loss
Δ 30 °Cmin4270112140
Appliance dimensions
(WxHxD)
Net weightkg12,916,321,625,7
Factual year energy
consumption
W1500150015001500
mmØ410х485Ø410х625Ø410х880Ø410х1055
kW•h270,1412,55598,6602,25
kW•h /
day
0,761,141,661,79
Dimensions
A
E
100
D
C
100
Fig. 1Fig. 2
Dimensions of water heaters (mm) are made in accordance with fig. 1 and
fig. 2.
Table 2
Capacity, lABCDE
RE11 30 V30
RE11 50 V50
RE11 80 V80
RE11 100 V10
Ø410
Ø410
Ø410
Ø410
485120115154
625120230181
880120465194
1055120625217
B
4
www.timberk.com • electrical storage water heater
5. WATER HEATER DESCRIPTION
6. SCOPE OF DELIVERY
RE11
2
1
9
8
7
Fig. 4
1. Internal tank
2. External case
3. Power cable
4. COLD water inlet nozzle
5. HOT water outlet nozzle
6. Control panel
7. Heating element
8. Protective magnesium anode
9. Heat insulation
5
1. Water heater – 1 pc.
2. Anchor bolt – 2 pcs.
3. Pressure safety valve – 1 pc.
4. Operation manual and guarantee slip – 1 pc.
5. Package – 1 pc.
3
4
6
www.timberk.com • electrical storage water heater
5
7. WATER HEATER INSTALLATION
Location
1. Electric water heater should be mounted on a firm wall.
2. The wall, where the electric water heater is to be mounted, must withstand
at least the double weight of the water heater, fully filled with water; there
must be no cracks and other damages on the wall. Otherwise it is necessary
to take measures to strengthen the mounting or mount the water heater on
a special support.
3. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to
reduce heat losses in pipelines, the location, where a water heater is to be
installed, must be as close to the place, where hot water is used, as possible.
Water heater mounting methods
Fig. 5 shows the way to mount the water heater for one consumption point.
6
www.timberk.com • electrical storage water heater
Fig. 5
1.Power cord with a plug
2.Water outlet
3.Hot water supply adjustment tap*
4.Mixer*
5.Shower header*
6.Cold water supply adjustment tap*
7.Pressure relieving opening
8.Check relief valve
9.Water inlet
10.Water heater
11.Water main shut-off valve*
12.Water main
13.T-bend*
*Does not included in the scope of delivery
IMPORTANT!
You can use the same way of installation for RE9. But,
please, note that pipe of cold water (9) is on the left
position. Pipe of hot water (2) is on the right.
Water heater mounting methods
Fig. 6 shows the way to mount the water heater for several consumption
points.
Fig. 6
6.Shower header*
7.Water main shut-off valve*
8.Pressure relieving opening
9.Water main
10.Bath tub*
11.T-bend*
12.Water outlet
13.Water inlet
*Does not included in the scope of delivery
Water heater mounting
NOTE:
Please, use accessories, provided by the manufacturer,
to install the water heater. Electric water heater must
not be mounted on a wall prior you make sure that the
bracket is installed firmly and securely. Otherwise the
electric water heater may fall down from the wall, which
may cause its damage and even serious accidents
involving bodily injury. When determining points for
bolt holes, it is necessary to provision some spare
space between the lower part of the water heater and
the floor not less than 0.6 m, to make it convenient to
perform maintenance if necessary.
1.Power cord with a plug
2.Water heater
3.Check relief valve
4.Cold water supply valve*
5.Mixer*
www.timberk.com • electrical storage water heater
7
NOTE:
The water heater is an appliance, operating in such
a manner that pressure of water in the water heater
corresponds to the pressure of water in water main.
If pressure in the main exceeds 0.8 MPa, then it is
necessary to mount a pressure reducer before the water
heater so that pressure doesn’t exceed 0.8 MPa.
Fig. 7
1. The electric water heater must be mounted on a solid wall. If wall strength
doesn’t allow to bear the double weight of the total water heater weight
fully filled with water, then it should be mounted on a special support.
2. After you chose the proper place to install the water heater, determine
points for holes for anchor hook bolts (to be determined in accordance
with the data sheet for the appliance you chose). Drill two holes of the
corresponding depth in the wall using a drill, dimensionally fit for anchor
bolts, enclosed with the water heater.
Then insert bolts into the drilled holes, and, turning bolt hooks clockwise,
securely tighten bolt nuts, then hang the water heater on these anchor bolt
hooks (see Fig. 7).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
220V/10A, single-phase, three-wired. It is recommended to place the
outlet on the right side above the water heater.
NOTE:
In places or on the wall, where there may be a water
contact, the power outlet installation height must be
not less than 1.8 m.
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.75 MPa.
8
www.timberk.com • electrical storage water heater
2. G1/2 diameter pipes are used to connect the water heater to the water
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets
on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow
of the water flow direction, so that the water flow direction coincides with
direction of the arrow on the valve’s case.
NOTE:
Do not mount additional accessories, such as a shut-off
valve, between the relief valve and the inlet nozzle.
5. Water heater with the mounted valve must be connected to the water
main – install a shut-off valve at the water inlet point. You need to connect
a drain pipe to the opening of the pressure relief of safety valve. Next you
should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle,
marked red.
7. Open the shut-off tap and one of the tap assemblies. After the tank is
filled with water, as evidenced by issue of water from the cock assembly,
shut the cock assembly and check the leak integrity of all joints.
IMPORTANT!
If water in the installation location contains a large
amount of calcium, manganese or iron salts, then
necessary to mount a respective filter in the delivery
system to reduce the amount of scale generated in
the tank and on the heating element.
Connection to electric main
IMPORTANT!
To provide reliable operation and safe use of the
water heater, prior to the first run check if it is properly
connected to the 220V~ AC mains. The water heater to
be connected must be securely linked with the earth
circuit of your electric mains. The waterheater must be
grounded properly, otherwise it is extremly dangerous
for life safety.
IMPORTANT!
Prior to connecting the tank water heater, make sure
that the water heater is properly grounded. Proper
grounding is important to minimize electric shocks
and risk of fire. The power cord is equipped with a plug
with a grounding pin. The appliance must be used
with a properly grounded power outlet. If the outlet,
you are intending to use, is not properly grounded or
grounded by a time-delay fuse or a circuit breaker,
contact a qualified electrician to install a proper outlet.
1. The water heater is designed to be connected to 220V~ single-phase
electric main. Prior to connecting make sure that parameters of the electric
main in the place of connection correspond to parameters, specified on the
identification plate with technical parameters of the appliance. You should
follow the current electrical safety code when installing the water heater.
2. The power outlet must be properly grounded. The outlet must be
designed for rated current not less than 10A, electric cable with copper
core must have cross section not less than 3x1.5 mm
The power outlet and plug must always be dry to prevent current leakage.
Regularly check if the power plug is tightly connected to the outlet. Do
it in the following order: insert the power plug into the outlet, switch off
the water heater after half-hour operation and unplug the cord, check if
the plug is heated by your hand. If the plug is heated over 50°C, then to
prevent damages, accidents and fire as a result of bad electrical contact,
replace the outlet with a new one. A specialist must do this.
2
(for copper).
8. WATER HEATER OPERATION
Fig.8
1. At first, open one of the separable taps at the water heater outlet, then
open the inlet tap. The electric water heater will start filling with water.
When water flows from separable tap freely, it means the water heater is
fully filled with water and you can close the separable tap.
NOTE:
During normal operation the cold water supply valve
must be opened.
2. Plug the power cord into the outlet.
www.timberk.com • electrical storage water heater
9
IMPORTANT!
The outlet must be designed for rated current not less
than 10A, electric cable with copper core must have
cross section not less than 3x1.5 mm2 (for copper).
3. Turn the thermostate handle (7) (fig. 4) clockwise and set the desirable
temperature. The temperature can be set from +35°C (±5°С) (MIN»
position of the thermostat knob) up to 75°C (±5°С) (rightmost position of
the thermostat knob). To reduce the water temperature turn the handle
anticlockwise.
4. Water temperature keeps up by the thermostate automatically. When
water temperature reach the set level, Heating is automatically switched off.
At that, the indicator lamp in the lower part of the appliance extinguishes.
When the temperature be lower then set, the heating will automaticlly start
again and the indicator lamp lights up.
5. To turn off the waterheater, turn the handle to the closest left position
«Off» and unplug the power cord or disconnect the appliance from the power
supply.
IMPORTANT!
Water can start to drip from the opening of safety valve
then heating process is going. It’s impossible to avoid
leakage of water and you can’t prevent this! Locking
of valve may cause rupture of the inner tank in case
of failure.
IMPORTANT!
«♥» position on the control panel corresponds to the
optimum water heating temperature of 58 +/-2°C, at
which:
1. The user is less likely to get burned in case when the
outlet water temperature is incorrectly adjusted.
2. A sufficient amount of hot water is obtained after
mixing with cold water, at a lesser power energy
consumption.
3. Less scale is generated on the heating element and
internal surfaces of the water heater.
10
www.timberk.com • electrical storage water heater
Fig. 9
Fig. 10
9. MAINTENCE
1. Check the power plug and outlet as often as possible. Secure electrical
contact and also proper grounding must be provided. The plug and outlet
must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with
low air temperature (below 0°C), it is necessary to drain water from the
heater to prevent damage of the water heater (due to water freezing in the
internal tank).
3. To ensure long reliable water heater operation, it is recommended to
regularly clean the internal tank and remove deposits on the electric heating
element of the water heater, as well as check condition (fully decomposed
or not) of the magnesium anode and, if necessary, replace it with a new one
in case of full decomposition.
4. Tank cleaning frequency depends on hardness of water located in this
territory. Cleaning must be performed by special maintenance services.
You can ask the seller for address of the nearest service center or find it on
the website www.timberk.com.
IMPORTANT!
The manufacturer provides an extended guarantee
for particular water heater components provided that
timely and proper routine maintenance is performed
by specialists of an authorized service center (see the
guarantee slip).
Preventive operations must be performed upon strict observance of the
operation manual and safety precautions.
5. The water heater is equipped with a thermal switch, which cuts off power
supply of the heating element upon water overheating or its absence in the
water heater. If the water heater is connected to the mains, but water is
not heated and the indicator doesn’t light up, then the thermal switch was
switched off or not switched on. To reset the water heater to the operating
condition, it is necessary to:
- de-energize the water heater, remove the plate of the side / lower cover.
- press the button, located at the center of the thermal switch, Fig.10 ;
- if the button is not pressed and there is no clicking, then you should wait
until the thermal switch cools down to the initial temperature.
www.timberk.com • electrical storage water heater
11
IMPORTANT!
If these actions had no positive result or the thermal
switch turns off repeatedly during a short period of
time, then you should de-energize the water heater,
cut off water supply and contact your local Timberk
Authorized Service Center for a consult or repair of the
appliance.
6. Water can be drained through a composite relief valve (Fig.9 ) (unscrew
the composite relief valve drain knob screw and set the drain knob to the
upper position, at that hot water tap must be open, and cold water supply
valve must be closed).
IMPORTANT!
Never drain water if its temperature is over 50°C since
it may result in burns.
7. Bear in mind to check serviceability of the relief valve every 14 days –
inspection method:
- turn the discharge lever to the left up until you feel the change of thread,
then water must start flowing from the valve’s hole. After checking the
water flow, return the lever to its initial position.
IMPORTANT!
If water doesn’t flow, then the valve is damaged.
In this case you must not use the heater and it is
recommended to call for a service technician.
10. TROUBLESHOOTING
Possible malfunctions and troubleshooting methods
Table 3
FailurePossible causesTroubleshooting method
Heating indicator light doesn’t light up,
water is not heated
Water doesn’t flow from the hot water
discharge cock
Water temperature is too highWater temperature control system
Water leakageSeal at the point of pipe connection
Water flows from the appliance’s case Breaking of the internal tank
1. Temperature adjustment device
is broken.
2. Temperature limiter was actuated or
was not switched on.
3. Temperature limiter is broken.Contact a repairer, TIMBERK service
1. Water feed is cut off.1. Wait until water supply is restored.
2. Water pressure is too low.2. Switch on the water heater again,
3. Water supply exhaust valve is
closed.
is damaged.
is broken.
(corrosion)Seal at the point of the
heating element connection is broken.
Contact a repairer, TIMBERK service
center.
Switch on the temperature switch
following instructions on its activation.
(page 15)
center.
when normal water pressure restores.
Contact a repairer, TIMBERK service
center.
Replace the joint seal.
Contact a repairer, TIMBERK service
center.
8. If necessary, wipe external surfaces of the heater by a damp cloth with
soap.
12
www.timberk.com • electrical storage water heater
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.