Timberk SWH RE 11 30 V User Manual [ru]

Instruction manual
Руководство по эксплуатации
Электрический накопительный водонагреватель
Модели/Models:
Руководство по эксплуатации включает в себя гарантийный талон
Outlook of devices, aslo colour scores can be revised without any special advance notices.
Производитель вправе менять внешний вид прибора и цветовую гамму при­бора без специального уведомления.
Electrical storage water heater
SWH RE11 30 V SWH RE11 50 V SWH RE11 80 V SWH RE11 100 V
TABLE OF CONTENTS
1. Important information
2. Precautions
3. Application of water heater
4. Performance parameters Technical characteristics Dimensions
5. Water heater description
6. Scope of delivery
7. Water heater installation
Location
Water heater mounting methods Water heater mounting Connection to water main Connection to electric main
8. Water heater operation
9. Maintenance
10. Troubleshooting
11. Wiring diagram
Dear customer!
Thank you for your good choice. You purchased TIMBERK
2
electric storage water heater with an enameled internal tank. It will serve you for a long time!
3 3
TIMBERK electric storage water heaters will provide a lot of hot water and will automatically maintain the specified
3
temperature. They are perfect to provide hot water for country
4
houses, cottages, baths and other standalone amenity rooms.
4 5 5 6 6
Please, read this operation manual carefully prior to use of the water heater.
6
This operation manual contains important information regarding your
7
safety, as well as recommendations on the proper operation of the unit and its maintenance.
8
Save this operation manual together with the guarantee card, cash register
9
receipt, if possible, cardboard box and packing material.
9
Different types of this device are described in this manual.
10
The purchased water heater can slightly differ from the one, described in
11
the manual, but that doesn’t affect methods of its use and operation.
11
1. IMPORTANT INFORMATION
IMPORTANT!
Important precautions and instructions, contained in this manual, do not account for all possible modes and situations to be encountered. It is vital to understand that common sense, caution and thoroughness are the factors that are impossible to be built-in in any product. These factors must be taken into consideration by a person, interested in proper operation of the unit. The manufacturer does not bear any responsibility in case when the unit or its parts are damaged during transportation, as a result of improper installation, voltage fluctuations, as well as if some part of the unit was altered or modified.
2
www.timberk.com • electrical storage water heater
2. PRECAUTIONS
Certain precautions are to be observed upon use of the water heater. Im­proper use due to ignoring precautions may harm health of the user and other people as well as damage their property.
1. Any electrical appliance must be under control upon its use, especially if there are children nearby. Make sure children do not touch the appliance.
2. Prior to installation of the water heater, not connecting it to the electri­cal main, check and make sure that the outlet for the water heater has a ground contact and it is properly earthed. If there is no earth loop in your electrical main then using of the water heater will be dangerous for your life.
3. Connect the water heater only to 220V / 50Hz electrical main. If neces­sary, find out parameters of your main at power suppliers.
4. To prevent overheating and risk of fire as well as damage of inner elec­trical main do not modify the power cord’s length and do not connect the water heater through power extension cord.
5. It is forbidden to switch on the water heater if it is not filled with water or if water cannot go through the pressure safety valve.
6. Never use the water heater if it is damaged.
7. Do not remove the water heater cover when it is in operation.
8. Immediately unplug the water heater from the electrical main if strange sounds, odour or smoke comes out from it.
9.Always unplug the water heater from the electrical main during thunder­storm.
10. Prior to cleaning and maintenance of the water heater unplug it from the electrical main every time. Cleaning and maintenance must be per­formed in compliance with the instructions contained in this manual.
11. Do not use hazardous chemical substances to clean the water heater and prevent their contact with the appliance.
12. To prevent electrical shock the damaged power cord must be replaced only by qualified specialists in manufacturer’s authorized service centres.
13. To prevent electrical shock do not place the power cord nearby heating devices and flammable or combustible agents.
14. As temperature of water in the water heater can reach 75°C when it is in operation you should not place your body parts under hot water upon the first run. To prevent burns you should adjust the temperature of the outflowing water.
15. Do not use the water heater for purposes not stipulated in this instruc-
tion manual.
16. Do not use the water heater in an explosive or corrosive environment. Do not store petrol and any other volatile flammable liquids near to the appliance. It is very dangerous!
17. It is forbidden to make alterations in the design of the water heater or modify it.
18. Any service works must be performed by a specialized organisation and qualified specialists. Improper installation may cause voiding of guar­antee maintenance.
19. The water heater is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or a lack of experience and knowledge unless they are under supervision or instructed on using of the appliance by a person responsible for their safety. Children should be controlled to ensure that they do not play with the appliance.
3. APPLICATION OF WATER HEATER
Electric water heater is used to heat cold water from water supply. Unit is for household use.
4. PERFORMANCE PARAMETERS
1. Completely automatic control: automatic water heating, continuous auto­matic water temperature control.
2. DROP Defense – leakage protection and protection against surplus pres- sure within a tank (pressure safety valve).
HOT Defense – two-stage overheating protection (thermostat and tempera­ture limiter).
ALL PROTECTION SYSTEMS ARE RELIABLE AND SAFE.
3. Steel internal tank with a special titanium fine glass enamel coating, applied by the modern electrostatic dry enameling method, is resistant to corrosion and scale. Also enamel has an increased adhesive capability and high ductility (hardened at 850°C), which allows it to expand and contract at temperature drops in the same ratio as the internal tank walls not generating microcracks, where corrosion may emerge.
4. Pipes of heating elements are designed taking into account high heat load: safe and reliable, with an increased service life.
www.timberk.com • electrical storage water heater
3
5. The water heater is equipped with an anode bar to protect the internal
tank from corrosion and decrease scale generation on the heating element.
6.Internal thickened urethane foam insulation allows to efficiently preserve
temperature of the heated water and minimize heat losses, reducing power consumption of the water heater.
7. The water heater has simple structure and is convenient in service.
Technical characteristics
Technical characteristics of water heaters are given below in Table 1. Table 1
Description Units RE11 30 V RE11 50 V RE11 80 V RE11 100 V
Power supply V/Hz 220~/50 220~/50 220~/50 220~/50
Rated current A 6,8 6,8 6,8 6,8
Nominal power
consumption
Tank capacity L 30 50 80 100
Rated pressure Mpa 0,8 0,8 0,8 0,8
Water protection IPX4 IPX4 IPX4 IPX4
Heating time, at
Constant daily heating loss
Δ 30 °C min 42 70 112 140
Appliance dimensions
(WxHxD)
Net weight kg 12,9 16,3 21,6 25,7
Factual year energy
consumption
W 1500 1500 1500 1500
mm Ø410х485 Ø410х625 Ø410х880 Ø410х1055
kW•h 270,1 412,55 598,6 602,25
kW•h /
day
0,76 1,14 1,66 1,79
Dimensions
A
E
100
D
C
100
Fig. 1 Fig. 2
Dimensions of water heaters (mm) are made in accordance with fig. 1 and fig. 2.
Table 2
Capacity, l A B C D E
RE11 30 V 30
RE11 50 V 50
RE11 80 V 80
RE11 100 V 10
Ø410
Ø410
Ø410
Ø410
485 120 115 154
625 120 230 181
880 120 465 194
1055 120 625 217
B
4
www.timberk.com • electrical storage water heater
5. WATER HEATER DESCRIPTION
6. SCOPE OF DELIVERY
RE11
2
1
9
8
7
Fig. 4
1. Internal tank
2. External case
3. Power cable
4. COLD water inlet nozzle
5. HOT water outlet nozzle
6. Control panel
7. Heating element
8. Protective magnesium anode
9. Heat insulation
5
1. Water heater – 1 pc.
2. Anchor bolt – 2 pcs.
3. Pressure safety valve – 1 pc.
4. Operation manual and guarantee slip – 1 pc.
5. Package – 1 pc.
3
4
6
www.timberk.com • electrical storage water heater
5
7. WATER HEATER INSTALLATION
Location
1. Electric water heater should be mounted on a firm wall.
2. The wall, where the electric water heater is to be mounted, must withstand
at least the double weight of the water heater, fully filled with water; there must be no cracks and other damages on the wall. Otherwise it is necessary to take measures to strengthen the mounting or mount the water heater on a special support.
3. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to reduce heat losses in pipelines, the location, where a water heater is to be installed, must be as close to the place, where hot water is used, as possible.
Water heater mounting methods
Fig. 5 shows the way to mount the water heater for one consumption point.
6
www.timberk.com • electrical storage water heater
Fig. 5
1.Power cord with a plug
2.Water outlet
3.Hot water supply adjustment tap*
4.Mixer*
5.Shower header*
6.Cold water supply adjustment tap*
7.Pressure relieving opening
8.Check relief valve
9.Water inlet
10.Water heater
11.Water main shut-off valve*
12.Water main
13.T-bend*
*Does not included in the scope of delivery
IMPORTANT!
You can use the same way of installation for RE9. But, please, note that pipe of cold water (9) is on the left position. Pipe of hot water (2) is on the right.
Water heater mounting methods
Fig. 6 shows the way to mount the water heater for several consumption points.
Fig. 6
6.Shower header*
7.Water main shut-off valve*
8.Pressure relieving opening
9.Water main
10.Bath tub*
11.T-bend*
12.Water outlet
13.Water inlet
*Does not included in the scope of delivery
Water heater mounting
NOTE:
Please, use accessories, provided by the manufacturer, to install the water heater. Electric water heater must not be mounted on a wall prior you make sure that the bracket is installed firmly and securely. Otherwise the electric water heater may fall down from the wall, which may cause its damage and even serious accidents involving bodily injury. When determining points for bolt holes, it is necessary to provision some spare space between the lower part of the water heater and the floor not less than 0.6 m, to make it convenient to perform maintenance if necessary.
1.Power cord with a plug
2.Water heater
3.Check relief valve
4.Cold water supply valve*
5.Mixer*
www.timberk.com • electrical storage water heater
7
NOTE:
The water heater is an appliance, operating in such a manner that pressure of water in the water heater corresponds to the pressure of water in water main. If pressure in the main exceeds 0.8 MPa, then it is necessary to mount a pressure reducer before the water heater so that pressure doesn’t exceed 0.8 MPa.
Fig. 7
1. The electric water heater must be mounted on a solid wall. If wall strength
doesn’t allow to bear the double weight of the total water heater weight fully filled with water, then it should be mounted on a special support.
2. After you chose the proper place to install the water heater, determine
points for holes for anchor hook bolts (to be determined in accordance with the data sheet for the appliance you chose). Drill two holes of the corresponding depth in the wall using a drill, dimensionally fit for anchor bolts, enclosed with the water heater.
Then insert bolts into the drilled holes, and, turning bolt hooks clockwise, securely tighten bolt nuts, then hang the water heater on these anchor bolt hooks (see Fig. 7).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
220V/10A, single-phase, three-wired. It is recommended to place the outlet on the right side above the water heater.
NOTE:
In places or on the wall, where there may be a water contact, the power outlet installation height must be not less than 1.8 m.
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.75 MPa.
8
www.timberk.com • electrical storage water heater
2. G1/2 diameter pipes are used to connect the water heater to the water pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow of the water flow direction, so that the water flow direction coincides with direction of the arrow on the valve’s case.
NOTE:
Do not mount additional accessories, such as a shut-off valve, between the relief valve and the inlet nozzle.
5. Water heater with the mounted valve must be connected to the water main – install a shut-off valve at the water inlet point. You need to connect a drain pipe to the opening of the pressure relief of safety valve. Next you should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle, marked red.
7. Open the shut-off tap and one of the tap assemblies. After the tank is filled with water, as evidenced by issue of water from the cock assembly, shut the cock assembly and check the leak integrity of all joints.
IMPORTANT!
If water in the installation location contains a large amount of calcium, manganese or iron salts, then necessary to mount a respective filter in the delivery system to reduce the amount of scale generated in the tank and on the heating element.
Connection to electric main
IMPORTANT!
To provide reliable operation and safe use of the water heater, prior to the first run check if it is properly connected to the 220V~ AC mains. The water heater to be connected must be securely linked with the earth circuit of your electric mains. The waterheater must be grounded properly, otherwise it is extremly dangerous for life safety.
IMPORTANT!
Prior to connecting the tank water heater, make sure that the water heater is properly grounded. Proper grounding is important to minimize electric shocks and risk of fire. The power cord is equipped with a plug with a grounding pin. The appliance must be used with a properly grounded power outlet. If the outlet, you are intending to use, is not properly grounded or grounded by a time-delay fuse or a circuit breaker, contact a qualified electrician to install a proper outlet.
1. The water heater is designed to be connected to 220V~ single-phase electric main. Prior to connecting make sure that parameters of the electric main in the place of connection correspond to parameters, specified on the identification plate with technical parameters of the appliance. You should follow the current electrical safety code when installing the water heater.
2. The power outlet must be properly grounded. The outlet must be designed for rated current not less than 10A, electric cable with copper core must have cross section not less than 3x1.5 mm
The power outlet and plug must always be dry to prevent current leakage. Regularly check if the power plug is tightly connected to the outlet. Do it in the following order: insert the power plug into the outlet, switch off the water heater after half-hour operation and unplug the cord, check if the plug is heated by your hand. If the plug is heated over 50°C, then to prevent damages, accidents and fire as a result of bad electrical contact, replace the outlet with a new one. A specialist must do this.
2
(for copper).
8. WATER HEATER OPERATION
Fig.8
1. At first, open one of the separable taps at the water heater outlet, then open the inlet tap. The electric water heater will start filling with water. When water flows from separable tap freely, it means the water heater is fully filled with water and you can close the separable tap.
NOTE:
During normal operation the cold water supply valve must be opened.
2. Plug the power cord into the outlet.
www.timberk.com • electrical storage water heater
9
IMPORTANT!
The outlet must be designed for rated current not less than 10A, electric cable with copper core must have cross section not less than 3x1.5 mm2 (for copper).
3. Turn the thermostate handle (7) (fig. 4) clockwise and set the desirable
temperature. The temperature can be set from +35°C (±5°С) (MIN» position of the thermostat knob) up to 75°C (±5°С) (rightmost position of the thermostat knob). To reduce the water temperature turn the handle anticlockwise.
4. Water temperature keeps up by the thermostate automatically. When
water temperature reach the set level, Heating is automatically switched off. At that, the indicator lamp in the lower part of the appliance extinguishes. When the temperature be lower then set, the heating will automaticlly start again and the indicator lamp lights up.
5. To turn off the waterheater, turn the handle to the closest left position
«Off» and unplug the power cord or disconnect the appliance from the power supply.
IMPORTANT!
Water can start to drip from the opening of safety valve then heating process is going. It’s impossible to avoid leakage of water and you can’t prevent this! Locking of valve may cause rupture of the inner tank in case of failure.
IMPORTANT!
«» position on the control panel corresponds to the optimum water heating temperature of 58 +/-2°C, at which:
1. The user is less likely to get burned in case when the outlet water temperature is incorrectly adjusted.
2. A sufficient amount of hot water is obtained after mixing with cold water, at a lesser power energy consumption.
3. Less scale is generated on the heating element and internal surfaces of the water heater.
10
www.timberk.com • electrical storage water heater
Fig. 9
Fig. 10
9. MAINTENCE
1. Check the power plug and outlet as often as possible. Secure electrical contact and also proper grounding must be provided. The plug and outlet must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with low air temperature (below 0°C), it is necessary to drain water from the heater to prevent damage of the water heater (due to water freezing in the internal tank).
3. To ensure long reliable water heater operation, it is recommended to regularly clean the internal tank and remove deposits on the electric heating element of the water heater, as well as check condition (fully decomposed or not) of the magnesium anode and, if necessary, replace it with a new one in case of full decomposition.
4. Tank cleaning frequency depends on hardness of water located in this territory. Cleaning must be performed by special maintenance services. You can ask the seller for address of the nearest service center or find it on the website www.timberk.com.
IMPORTANT!
The manufacturer provides an extended guarantee for particular water heater components provided that timely and proper routine maintenance is performed by specialists of an authorized service center (see the guarantee slip).
Preventive operations must be performed upon strict observance of the operation manual and safety precautions.
5. The water heater is equipped with a thermal switch, which cuts off power supply of the heating element upon water overheating or its absence in the water heater. If the water heater is connected to the mains, but water is not heated and the indicator doesn’t light up, then the thermal switch was switched off or not switched on. To reset the water heater to the operating condition, it is necessary to:
- de-energize the water heater, remove the plate of the side / lower cover.
- press the button, located at the center of the thermal switch, Fig.10 ;
- if the button is not pressed and there is no clicking, then you should wait until the thermal switch cools down to the initial temperature.
www.timberk.com • electrical storage water heater
11
IMPORTANT!
If these actions had no positive result or the thermal switch turns off repeatedly during a short period of time, then you should de-energize the water heater, cut off water supply and contact your local Timberk Authorized Service Center for a consult or repair of the appliance.
6. Water can be drained through a composite relief valve (Fig.9 ) (unscrew
the composite relief valve drain knob screw and set the drain knob to the upper position, at that hot water tap must be open, and cold water supply valve must be closed).
IMPORTANT!
Never drain water if its temperature is over 50°C since it may result in burns.
7. Bear in mind to check serviceability of the relief valve every 14 days –
inspection method:
- turn the discharge lever to the left up until you feel the change of thread,
then water must start flowing from the valve’s hole. After checking the water flow, return the lever to its initial position.
IMPORTANT!
If water doesn’t flow, then the valve is damaged. In this case you must not use the heater and it is recommended to call for a service technician.
10. TROUBLESHOOTING
Possible malfunctions and troubleshooting methods Table 3
Failure Possible causes Troubleshooting method
Heating indicator light doesn’t light up, water is not heated
Water doesn’t flow from the hot water discharge cock
Water temperature is too high Water temperature control system
Water leakage Seal at the point of pipe connection
Water flows from the appliance’s case Breaking of the internal tank
1. Temperature adjustment device is broken.
2. Temperature limiter was actuated or was not switched on.
3. Temperature limiter is broken. Contact a repairer, TIMBERK service
1. Water feed is cut off. 1. Wait until water supply is restored.
2. Water pressure is too low. 2. Switch on the water heater again,
3. Water supply exhaust valve is closed.
is damaged.
is broken.
(corrosion)Seal at the point of the heating element connection is broken.
Contact a repairer, TIMBERK service center.
Switch on the temperature switch following instructions on its activation. (page 15)
center.
when normal water pressure restores.
Contact a repairer, TIMBERK service center.
Replace the joint seal.
Contact a repairer, TIMBERK service center.
8. If necessary, wipe external surfaces of the heater by a damp cloth with
soap.
12
www.timberk.com • electrical storage water heater
Loading...
+ 28 hidden pages