Optiset Plus
The controller can be programmed with OptiSet Plus temperature profiles that allow the user to select named products and/or numeric setpoints. See the appropriate Operator’s Manual for more detailed information about using OptiSet Plus.
Numeric Setpoint - If the controller does not have named products loaded, the far left soft key will display
S
ETPOINT
as shown below. Th is is the fac tory default setting. Change the numeric setpoint like you normally would on an SR-2 Controller.
Named Products - The controller can be programmed to allow only named products to be selected. In which case the far left soft key will display
P
RODUCT
as shown below.
Named products can have a single setpoint, or they can have a setpoint range that allows the user to select a setpoint within that range.
NOTE: In OptiSet Plus the terms “numeric setpoint” and “setpoint” mean the same thing and are displayed as numbers. The terms “named product” and “product” mean the same thing and ar e displayed as words.
NOTE: Alarm Code 127, Setpoint Not Entered, may be generated if the
+
or - soft keys are used to change
the numeric setpoint or named product, but the
Y
ES
or
N
O
soft keys are not used to accept or decline the
new setting within 10 seconds.
Named Products or Numeric Setpoint -The controller can be programmed to allow named products or numeric setpoints to be selected. In which case the far left soft key will display
P
RODUCT
/
S
ETPOINT
as shown below.
Selecting a Numeric Setpoint
To select or change a numeric setpoint complete the following steps. This example shows the Standard Displa y with the
P
RODUCT/SETPOINT
soft key. Using the
Standard Display with the
S
ETPOINT
soft key is basically
the same but some of the screens differ slightly.
1. Begin at the Standard Display. If the Temperature Watch Display is showing, press the
M
ENU
soft key once to return to the Standard
Display.
2. Press the
P
RODUCT/SETPOINT
(or
S
ETPOINT
) soft
key on the Standard Display.
3. The “Named Product / Numeric Setpoint?” Screen briefly appears, then the “Named Produ ct or N umeric Setpoint?” Screen will appear.
4. Press the
N
UMERIC
soft key.
5. The “Setpoint” Screen briefly appears, then the “Current Setpoint Is” Screen will appear.
6. Press the
+
or
-
soft keys to change the setpoint.
7. Press the
YES
soft key to select the new setpoint.
• If the
N
O
key is pressed the setpoi nt change selecte d
with the
+
or - soft keys will not be accepted, the setpoint will not be changed and the display will return to the Standard Display.
• If the
Y
ES
soft key is pressed, the setpoint change
selected with the
+
or - soft keys will be accepted,
and the following screens will appear.
8. The “Programming New Setpoint” Screen will briefly appear.
9. The “New Setpoint Is 40” Screen briefly appears.
10. The Standard Display appears with the new setpoi nt.
NOTE: Pressing the
E
XIT
soft key at any point will
return to the Standard Display. NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will return to the Standard Display.
Selecting a Named Product
To select or change a named product complete the following steps. This example s hows the S ta ndard Display with the
P
RODUCT/SETPOINT
soft key. Using the
Standard Display with the
P
RODUCT
soft key is basically
the same but some of the screens differ slightly.
1. Begin at the Standard Display. If the Temperature Watch Display is showing, press the
M
ENU
soft key once to return to the Standard
Display.
2. Press the
P
RODUCT/SETPOINT
(or
P
RODUCT
) soft
key on the Standard Display.
3. The “Named Product / Numeric Setpoi nt?” (or Named Product) Screen briefly appears, then the “Named Product or Numeric Setpoint?” (or Named Product) Screen will appear.
4. Press the
N
AMED
soft key.
5. The “Product” Screen briefly appears, then the “Current Product Is” Screen will appear.
6. Press the
+
or
-
soft keys to change the named
product.
7. Press the
YES
soft key to select the new named
product.
• If the
N
O
key is pressed the named product change
selected with the
+
or - soft keys will not be accepted, the named product will not be changed and the display will return to the Standard Display. (Over)
1
2
4
6
7
1
2
4
6
7
•If the
Y
ES
soft key is pressed, the named product
change selected with the
+
or - soft keys will be
accepted, and the following screens will appear.
8. The “Programming Named Product” Screen will briefly appear.
NOTE: If the “Change Setpoint for Potatoes” Screen briefly appears, the named product has been programmed with a setpoint range. See “Selecting the Setpoint for a Named Product” below.
9. The “New Named Product Is Potatoes” Screen briefly appears.
10. The Standard Display appears with the new named product.
NOTE: Pressing the
E
XIT
soft key at any point will
return to the Standard Display. NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will return to the Standard Display.
Selecting the Setpoint for a Named Product
If the “Change Setpoint for Potatoes” Screen appears after pressing the
Y
ES
soft key to select a named product, the named product has been program med w it h a s etpo int range. Complete the following steps to select a setpoint for the named product.
1. The “Change Setpoint for Potatoes” Screen briefly
appears, then the “Current Setpoint of Potatoes & Setpoint Range Is 40 to 50” Screen will appear.
2. Press the
+ /- or E
XIT
soft keys accordingly as
described below.
• Press the
+
or
-
soft keys to change the current setpoint for the named product. Go to step 6 under “Changing the Setpoint for a Named Product” to continue.
OR
• Press the
E
XIT
soft key to accept the curre nt setpoin t for the named product. The Standard Display will appear with the named product and setpoint.
NOTE: Pressing the
E
XIT
soft key at any point will
return to the Standard Display. NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will return to the Stan dard Display and the setpoint will remain at the displayed setpoint.
Changing the Setpoint for a Named Product
If the named product has been programmed with a setpoint range, the setpoint for the named product can be changed. This example shows the Standard Display with the
P
RODUCT/SETPOINT
soft key.
1. Begin at the Standard Display. If the Temperature Watch Display is showing, press the
M
ENU
soft key once to return to the Standard
Display.
2. Press the
P
RODUCT/SETPOINT
soft key on the
Standard Display.
3. The “Named Product, Numeric Setpoint or Change Setpoint?” Screen will appear.
4. Press the
C
HANGE
SP
soft key.
5. The “Change Setpoint for Potatoes” Screen briefly appears, then the “Current Setpoint for Potatoes & Setpoint Range Is 40 to 50” Screen will appear.
6. Press the + or
-
soft keys to change the setpoint.
7. Press the
YES
soft key to accept the new setpoint.
• If the
N
O
key is pressed the named product setpoint
change made with the
+
or - soft keys will not be accepted, the named product setpoint will not be changed and the display will return to the Standard Display.
• If the
Y
ES
soft key is pressed, the named product
setpoint change made with the
+
or - soft keys will be
accepted, and the following screens will appear.
8. The “Programming New Setpoint for Potatoes” Screen will briefly appear.
9. The “New Setpoint Is 40” Screen briefly appears.
10. The Standard Display appears with the new setpoi nt.
NOTE: Pressing the
E
XIT
soft key at any point will
return to the Standard Display. NOTE: If no keys are pressed for 30 seconds while in
the Named Product Changer Screens, the HMI will return to the Standard Display.