Thermador VTR630P Installation manual

VTR630P VENTILATION BLOWER MOTOR INSTALLATION MANUAL
MANUEL D'INSTALLATION DU VENTILATEUR VTR630P
MANUAL DE INSTALACIÓN DEL
Models/ Modèles/ Modelos:
VTR630P
VENTILADOR VTR630P
Table of Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 1: EXHAUST-AIR MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 2: PREPARING THE WALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 3: INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wire Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Customer Support, Accessories & Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .back page
Safety Definitions
WARNING
This indicates that death or serious injuries may occur as a result of non-observance of this warning.
CAUTION
This indicates that minor or moderate injuries may occur as a result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or property may occur as a result of non-compliance with this advisory.
Note: This alerts you to important information and/or tips.
This Thermador appliance is made by
BSH Home Appliances Corporation
1901 Main Street, Suite 600
Irvine, CA 92614
Questions?
1-800-735-4328
www.thermador.com
We look forward to hearing from you!
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT: Save these Instructions for the Local Gas Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.This appliance conforms to the relevant safety regulations.
Repairs should only be carried out by qualified specialists.
Check if this blower is recommended by the manufacturer to be installed with the hood.
WARNING
To avoid electrical shock hazard, before installing, switch power off at the service panel and lock the panel to prevent the power from being switched on accidentally.
WARNING
TO REDUCE THE RISK OF FIRE, OR INJURY TO PER FOLLOWING:
a) Installation work and electrical wiring must be done
by qualified person(s) in accordance with all applicable codes and regulations, including fire­related construction.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) To properly exhaust air, be sure to duct air outside.
DO NOT vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
SONS, OBSERVE THE
ELECTRIC SHOCK,
WARNING
To reduce the risk of fire or electric this blower with any solid-state
WARNING
State of California Proposition 65 Warnings:
This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
WARNING
To reduce the risk of fire, use only metal ductwork.
shock, do not use
speed control device.
Grounding instructions
This appliance must be grounded. In the event of an electrical short-circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
WARNING
Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt as to whether the appliance is properly grounded.
None of the packing materials cause pollution to the environment and all can be recycled for use again. Please help to protect the environment and dispose of the packaging in an environment-friendly manner.
Remove all tape and packaging before using the appliance. Destroy or recycle the packaging after unpacking the appliance.
Never allow children to play with packaging material.
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT
use to exhaust hazardous or explosive materials and vapors.
English 1
Installation
Step 1: EXHAUST-AIR MODE
Equipment Needed
Drill and Bit
Screwdriver
Rubber Mallet
Equipment Included
Anchors (4)
Screws (4)
Connector
Exhaust air should not be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located.
Exhaust air must be discharged in accordance with official and statutory regulations only (e.g. national building regulations).
Local regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use.
If the air intake is inadequate, there is a risk of carbon monoxide poisoning from combustion gases which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
NOTE: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the
use of cooking appliances, such as ranges and ovens.
IMPORTANT SAFETY INSTRUCTIONS
The blower must be attached at least 78¾'' (200 cm) from the extractor hood.
When attaching the outer wall blower, ensure that it is accessible for maintenance and repairs.
The plug-and-socket connections of the electric cables must be located inside the building, according to local codes.
DO NOT reduce the 6'' (152 mm) diameter of the ducting connected to the extractor hood.
Step 2: PREPARING THE WALL
When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers), care must be taken to ensure that there is an adequate supply of fresh air, which will be needed by the burner for combustion.
Safe operation is possible provided that the under-pressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).
This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air-intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.
The wall must be flat and perpendicular.
Ensure that the wall is capable of providing a firm hold for mounting screws and anchors.
Weight: 10.3 kg / 23 lbs
Technical
Electrical Requirements: 120 V; 60 Hz, max. 4.2 A
Duct Size: 6" (152 mm)
Information
English 2
Step 3: INSTALLATION
min. 40"
(101.5 cm)
min. Ø ¾"
(19 mm)
½"
(12.7 mm)
(100 mm)
min. Ø 6½"
(16.5 mm)
15
/
16
"
3
(424 mm)
11
/
16
"
(211 mm)
5
/
16
"
8
(21 mm)
13
/
16
"
10⅞"
(276 mm)
5¼"
(133 mm)
1. Hold the blower on the wall. Note the direction of the air conduction.
2. Mark the 4 mounting boreholes.
At least one screw must be installed through a
stud.
All hardware must be suitable for the wall’s
construction materials.
Ensure the air outlet points downward.
3. Wall break: Mark and drill a guide hole and a separate hole for
electrical conduit.
4. Drill the 4 x ¼'' (6,3 mm) Ø mounting boreholes. Insert wall anchors and screw the blower to the wall.
5. Connect the ducting from the blower to the extractor hood and feed to the outside.
min. 40"
min. 40"
(101.5 cm)
(101.5 cm)
15
15
3
(100 mm)
min. Ø 6½"
min. Ø 6½"
(16.5 mm)
(16.5 mm)
10⅞"
10⅞"
(276 mm)
(276 mm)
/
/
16
16
min. Ø ¾"
min. Ø ¾"
"
"
(19 mm)
(19 mm)
(12.7 mm)
(12.7 mm)
½"
½"
5¼"
5¼"
(133 mm)
(133 mm)
5
5
8
/
/
16
16
(211 mm)
(211 mm)
13
13
"
"
/
/
16
16
(21 mm)
(21 mm)
"
"
11
11
"
"
161616
(424 mm)
/
/
16
16
English 3
6. Connect the blower to the extractor hood with an
(21 mm)
13
/
16
"
extension cable, if required. Use the added connector to hard-wire to the blower, if
required. Use the wire diagram for connecting.
WARNING
The additional cover on the plug must always be
• attached and closed for safety reasons.
Not needed wires must be isolated, capped with wire
• nuts and stored in a safe position.
13
13
"
"
/
/
16
16
(21 mm)
NOTE: Confirm that the blower is securely attached to the wall and all connections are secure.
NOTE: The unit can also be installed on the roof in combination with a roof plate accessory (RFPLT600P or RFPLT1000P). Ask your retailer or contact the Thermador Customer Service Team at 1-800-735-4328.
English 4
Wire Diagram
speed 1 (red)
speed 2 (blue)
speed 3 (orange)
speed 4 (brown)
N (white)
PE (green/yellow)
orange
brown
green/yellow
blue
red
white (N)
English 5
Table des matières
Sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Étape 1 : MODE D'ÉVACUATION DE L'AIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Étape 2 : PRÉPARATION DU MUR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Étape 3 : INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Schéma de câblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Entretien, Pièces et Accessoires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page verso
Définitions concernant la sécurité
AVERTISSEMENT
Ceci indique que le non respect de cet avertissement peut entraîner des blessures graves, voire la mort.
ATTENTION
Ceci indique que le non respect de cet avertissement peut entraîner des blessures légères ou modérées.
NOTICE : Ceci indique que la non-conformité à cet avis de sécurité peut entraîner des dégâts à l'appareil ou à la propriété.
Note : Ceci vous avertit que d'importantes informations et/ou conseils sont fournis.
Cet appareil électroménager de Thermador
est fait par BSH Home Appliances LtD
6696 Financial Drive, Unit 3
Mississauga, ON L5N 7J6
Des questions?
1-800-735-4328
www.thermador.ca
Nous attendons de vos nouvelles!
Sécurité
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
LISEZ ET CONSERVEZ CES INSTRUCTIONS
IMPORTANT : Conservez ces instructions pour l’inspecteur de la société gazière de votre localité.
INSTALLATEUR : Veuillez laisser ces instructions d’installation avec l’appareil pour le propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour consultation ultérieure.
Cet appareil est conforme aux règlements de sécurité pertinents.
Les réparations doivent uniquement être effectuées par des spécialistes qualifiés.
Vous pouvez obtenir des informations sur la meilleure façon de mettre au rebut les vieux appareils électroménagers et les matériaux d'emballage auprès de votre revendeur ou du conseil municipal local.
Vérifiez si ce ventilateur peut être monté en association avec la hotte aspirante.
AVERTISSEMENT
Pour éviter tout risque de choc électrique, avant d'installer, coupez le courant au panneau et verrouiller le panneau pour empêcher l'activation accidentelle de la puissance.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE PRÉJUDICE PHYSIQUE, RESPECTEZ LES CONSIGNES SUIVANTES :
a) Tout travail d'installation ou câblage électrique doit
être réalisé par une ou des personnes qualifiées, conformément à tous les codes et normes applicables, y compris ceux relatifs à la construction résistante au feu.
b) Une circulation d'air efficace est requise afin
d'assurer la combustion et l'évacuation complète des gaz par le tuyau d'évacuation (cheminée) des équipements à combustible pour prévenir les retours d'air. Suivez les normes et mesures de sécurité des fabricants d'appareils de chauffage publiées par la « National Fire Protection Association » (NFPA), la «
American Society for Heating, Refrigeration and Air
Conditioning Engineers » (ASHRAE), et les autorités du code local.
c) Lorsque vous percez les murs et plafonds, évitez
d'endommager les fils électriques et les autres canalisations de services publics non visibles.
d) Pour obtenir une bonne évacuation de l'air, veillez à
ce que l'air soit acheminé vers l'extérieur. Ne pas évacuer l'air dans des espaces enfermés par des murs, ou dans un plafond, un grenier, un vide sanitaire ou un garage.
ATTENTION
POUR LA VENTILATION GÉNÉRALE SEULEMENT.
Ne pas utiliser l'appareil pour évacuer des matières ou vapeurs dangereuses ou explosives.
AVERTISSEMENT
Pour réduire le risque d'incendie ou de choc électrique, ne pas utiliser ce ventilateur avec un régulateur de vitesse à semiconducteurs.
AVERTISSEMENT
Afin de réduire le risque d'incendie, n'utiliser que des conduits en métal.
AVERTISSEMENT
Avertissements de la Proposition 65 de l'État de la Californie :
Ce produit contient des produits chimiques connus de l'État de la Californie pour causer le cancer, des anomalies congénitales ou d'autres problèmes de reproduction.
Français 1