Safety Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Définitions concernant la sécurité ........................................................................................................................... 1
Definiciones de seguridad ........................................................................................................................................ 1
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Sécurité ......................................................................................................................................................................3
Seguridad ...................................................................................................................................................................5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation .................................................................................................................................................................7
Instalación ..................................................................................................................................................................7
This Thermador appliance is made by
BSH Home Appliances Corporation
1901 Main Street, Suite 600
Irvine, CA 92614
Questions?
1-800-735-4328
www.thermador.com
We look forward to hearing from you!
Safety Definitions
WARNING
This indicates that death or serious injuries may occur as a result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or property may occur as a result of non-compliance with this advisory.
Note: This alerts you to important information and/or tips.
CAUTION
This indicates that minor or moderate injuries may occur as a result of non-observance of this warning.
Définitions concernant la sécurité
AVERTISSEMENT
Ceci indique que le non respect de cet avertissement peut entraîner des blessures graves, voire la mort.
ATTENTION
Ceci indique que le non respect de cet avertissement peut entraîner des blessures légères ou modérées.
NOTICE : Ceci indique que la non-conformité à cet avis de sécurité peut entraîner des dégâts à l'appareil ou à la propriété.
Note : Ceci vous avertit que d'importantes informations et/ ou conseils sont fournis.
Definiciones de seguridad
ADVERTENCIA
Esto indica que se pueden producir lesiones graves o la muerte si no se cumple con esta advertencia.
PRECAUCIÓN
Esto indica que pueden producirse lesiones leves o moderadas si no se cumple con esta advertencia.
NOTA: Esto indica que puede producirse un daño al electrodoméstico o a la propiedad como resultado de la falta de cumplimiento de este aviso.
Nota: Esto lo alerta sobre información y/o consejos importantes.
1
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.This appliance conforms to the relevant safety
regulations.
Equipment Needed Equipment Included
䙚 Drill and Bit
Screwdriver
The unit must be sealed to the roof, e.g. screws, pipe connections, roof cutout, etc.
The sides of the roof plate may have sharp edges. Risk of injury! Wear protective gloves for mounting.
Repairs should only be carried out by qualified specialists.
Check if this blower is recommended by the manufacturer to be installed with the hood.
Anchors (18)
Screws #10 X 1'' (18)
Screws 3.9 x 9.5 (8)
WARNING
TO REDUCE THE RISK OF FIRE, OR INJURY TO PER FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and regulations, including fire-related construction.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) To properly exhaust air, be sure to duct air outside.
DO NOT vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
SONS, OBSERVE THE
ELECTRIC SHOCK,
WARNING
To avoid electrical shock hazard, before installing, switch power off at the service panel and lock the panel to prevent the power from being switched on accidentally.
CAUTION
FOR GENERAL VENTILATING USE ONLY. Do not use
to exhaust hazardous or explosive materials and vapors.
WARNING
To reduce the risk of fire or electric blower with any solid-state
WARNING
State of California Proposition 65 Warnings:
This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
WARNING
speed control device.
shock, do not use this
Grounding instructions
This appliance must be grounded. In the event of an electrical short-circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
WARNING
Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt as to whether the appliance is properly grounded.
None of the packing materials cause pollution to the environment and all can be recycled for use again. Please help to protect the environment and dispose of the packaging in an environment-friendly manner.
Remove all tape and packaging before using the appliance. Destroy or recycle the packaging after unpacking the appliance.
Never allow children to play with packaging material.
To reduce the risk of fire, use only metal ductwork.
2
Sécurité
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
LISEZ ET CONSERVEZ CES INSTRUCTIONS
INSTALLATEUR : Veuillez laisser ces instructions d’installation avec l’appareil pour le propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour consultation ultérieure.
Équipement requis Équipement inclus
䙚 Perceuse électrique et
foret
Tournevis
L'appareil doit posséder une barrière étanche dans le toit, p. ex. vis, raccords de tuyauterie, découpe de toit etc.
Les côtés de la plaque de toit peuvent comporter des bords coupants. Risque de blessures! Nous recommandons de porter des gants lors du montage.
Cet appareil est conforme aux règlements de sécurité pertinents.
Les réparations doivent uniquement être effectuées par des spécialistes qualifiés.
Vous pouvez obtenir des informations sur la meilleure façon de mettre au rebut les vieux appareils électroménagers et les matériaux d'emballage auprès de votre revendeur ou du conseil municipal local.
Vérifiez si ce ventilateur peut être monté en association avec la hotte aspirante.
AVERTISSEMENT
Pour éviter tout risque de choc électrique, avant d'installer, coupez le courant au panneau et verrouiller le panneau pour empêcher l'activation accidentelle de la puissance.
Boulons d'ancrage (18)
Vis #10 x 1 po (18)
Vis 3,9 x 9,5 (8)
AVERTISSEMENT
Pour réduire le risque d'incendie ou de choc électrique, ne pas utiliser ce ventilateur avec un régulateur de vitesse à semiconducteurs.
AVERTISSEMENT
Afin de réduire le risque d'incendie, n'utiliser que des conduits en métal.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE PRÉJUDICE PHYSIQUE, RESPECTEZ LES CONSIGNES SUIVANTES :
a) Tout travail d'installation ou câblage électrique doit
être réalisé par une ou des personnes qualifiées, conformément à tous les codes et normes appli­cables, y compris ceux relatifs à la construction résis­tante au feu.
b) Une circulation d'air efficace est requise afin d'assurer
la combustion et l'évacuation complète des gaz par le tuyau d'évacuation (cheminée) des équipements à combustible pour prévenir les retours d'air. Suivez les normes et mesures de sécurité des fabricants d'appareils de chauffage publiées par la « National Fire Protection Association » (NFPA), la « American Society for Heating, Refrigeration and Air Conditioning Engineers » (ASHRAE), et les autorités du code local.
c) Lorsque vous percez les murs et plafonds, évitez
d'endommager les fils électriques et les autres canalisations de services publics non visibles.
d) Pour obtenir une bonne évacuation de l'air, veillez à
ce que l'air soit acheminé vers l'extérieur. Ne pas évacuer l'air dans des espaces enfermés par des murs, ou dans un plafond, un grenier, un vide sanitaire ou un garage.
AVERTISSEMENT
ATTENTION
POUR LA VENTILATION GÉNÉRALE SEULEMENT. Ne
pas utiliser l'appareil pour évacuer des matières ou vapeurs dangereuses ou explosives.
Avertissements de la Proposition 65 de l'État de la Californie :
Ce produit contient des produits chimiques connus de l'État de la Californie pour causer le cancer, des anomalies congénitales ou d'autres problèmes de reproduction.
3