Thermador PRD48NLSGU Installation

Ventilation Planning Guide
For THERMADOR PROFESSIONAL Ranges, Rangetops, and Hoods
Models | Modèles | Modelos:
Guide de Planification de Ventilation
Pour les cuisinières, surface de cuisson, et hottes PROFESSIONAL de THERMADOR
Guía de Planificación de Ventilación
Para las estufas, placas de cocción, y campanas PROFESSIONAL de THERMADOR
PRO GRAND DUAL FUEL RANGES
PRO GRAND GAS RANGES
PRO HARMONY DUAL FUEL RANGES
PRO HARMONY GAS RANGES
PRO RANGETOPS
PRO WALL HOODS
PRO CHIMNEY HOODS
PRO CUSTOM INSERT HOODS
Ventilation Planning Guide
It is recommended that a THERMADOR PROFESSIONAL hood is used with a THERMADOR PROFESSIONAL range or rangetop. The following range and rangetop ventilation combinations are approved installations.
All blower models referenced may not be compatible with all hoods referenced. Refer to www.thermador.com for a complete selection of ventilation options, blowers, and accessories.
IMPORTANT NOTES:
See related Thermador Manuals for additional information.
Thermador recommends not exceeding 50 ft. (15.24 m) equivalent length of duct.
Keep duct runs as short and straight as possible. Elbows and transitions fittings reduce air flow efficiency. Back to back elbows and “S” turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of a remote blower gives the best delivery.
For Thermador Pro Ranges applications with a non-approved Thermador hood. The hood and/or blower must be rated for 1 CFM for every 100 BTU on the Range/Rangetop.
If the range has a 12'' Griddle, add an additional 200 CFM to the estimated blower capacity.
If the range has a 24'' Griddle, add an additional 400 CFM to the estimated blower capacity.
If the range has a Grill, add an additional 400 CFM to the estimated blower capacity.
If the range has a Grill and a Griddle, add an additional 600 CFM to the estimated blower capacity.
For island applications, it is recommended to use a hood width that exceeds the width of the range by 6'' (152 mm), overlapping the range or rangetop by a minimum of 3'' (76 mm) on each end.
A 25 foot extension cable (EXTNCB25) is available for purchase to connect the hood to in-line or remote blowers, if required.
English | 1 |
Range hoods with selectable blowers:
Range or Rangetop
Model
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct.
30'' PH30HS VTN630* VTI610*
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct.
30'' PH30HS, HPCN36NS, PH36GS,
PH36HS, VCIN36JP
36'' without Grill or Griddle 36'' with Griddle
48'' with Griddle only HPCN48NS, PH48GS, PH48HS,
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct.
36'' with Grill HPCN36NS, PH36GS, PH36HS,
48'' with Grill 48" with Grill and Griddle
60" with Grill and Griddle 60" with Double Griddle
* Indicates a letter designating the release year.
HPCN36NS, PH36GS, PH36HS, VCIN36JP, PH42GS, HPCN48NS, PH48GS, PH48HS, VCIN48JP
VCIN48JP, PH54GS, VCIN54JP
VCIN36JP, PH42GS, HPCN48NS, PH48GS, PH48HS, VCIN48JP
HPCN48NS, PH48GS, PH48HS, VCIN48JP, PH54GS, VCIN54JP
VCIN60RP, PH60GS VTN1090*
VCIN60RP, PH60GS VTN1090*
Recommended
Hood Models
Min. Integral
Blower
VTN1030* VTN1090*
VTN1030* VTN1090*
Min. In-Line or
Remote Blower
VTR630*
VTI1010*
VTR1030*
VTI1010*
VTR1030*
Other Available
Blowers
N/A
VTR1330* VTN1080*
VTR1330* VTN1080*
Range hoods with blower included:
Range or Rangetop Model Recommended Hood Models
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct.
30'' HPWB30FS
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct.
30'' HPCB36NS, HPWB36FS, VCIB36JP
36'' without Grill or Griddle 36'' with Griddle
48'' with Griddle only HPCB48NS, HPWB48FS, VCIB48JP, VCIB54JP
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct.
36'' with Grill HPCB36NS, HPWB36FS, VCIB36JP, HPWB48FS, VCIB48JP
48'' with Grill
48" with Grill and Griddle
HPCB36NS, HPWB36FS, VCIB36JP, HPCB48NS, HPWB48FS, VCIB48JP
HPCB48NS, HPWB48FS, VCIB48JP, VCIB54JP