Thermador PCG486NL Specification Sheet

PCG486NL
48-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
GENERAL PROPERTIES
Controls Metal Knobs
Sealed Burners Yes
Grate Material Cast Iron
BURNER PERFORMANCE
FEATURES & BENEFITS
- Patented Pedestal Star® Burner with QuickClean Base® designed for easy surface cleaning and superior heat spread for any size pan
- Precision simmering capabilities as low as 100°F (375 BTU) with 2 ExtraLow® Simmer burners
- 18,000 BTU (NG) Star® Burners
- Superior grill results, 1,630 Watt indoor electric grill
- Non-stick, rust-proof cast-aluminum grill with fusion coated surface, removable for easy cleanup
ACCESSORIES (OPTIONAL)
PABRICKBKN Black Ceramic Briquettes with Basket
PA12LCVRN 12" Pro Grill Cover for Indoor Electric Grill
PAGRIDDLEN 12" Pro Griddle
PA12CVRJ 12" Griddle / Pro Grill Cover
PA12CHPBLK 12" Cutting Board
PWOKRINGHC Wok Ring
PA48GLBC 12" Low Backguard
PAKNOBLUNH Blue Knob Kit
Total Number of Cooktop Burners 6
Total BTU Load (NG / LP) 108,000
Power of Front Left Burner (NG / LP) 18,000
Power of Back Left Burner (NG / LP) 18,000
Power of Back Center Burner (NG / LP) 18,000
Power of Front Center Burner (NG / LP) 18,000
Power of Center 12" Electric Griddle (W) N/A
Power of Center 12" Electric Grill (W) 1,630 W
Power of Back Right Burner (NG / LP) 18,000
Power of Front Right Burner (NG / LP) 18,000
TECHNICAL DETAILS
Circuit Breaker (A) 15 A
Volts (V) 120 V
Frequency (Hz) 60 Hz
Plug Type 120V-3 Prong
Power Cord Length (in) 72"
Energy Source Gas
Gas Type Natural Gas 15 mbar
Alternative Gas Type LP 27, 5 mbar (USA)
Convertible To LP (Kit Required) Yes
DIMENSIONS & WEIGHT
Overall Appliance Dimensions (H*xWxD) (in) 10 9/16" x 47 15/16"
Required Cutout Size (HxWxD) (in) 7 11/16" x 46 1/4"
Minimum Distance From Rear Wall (in) 12" min to
Net Weight (lbs) 172 lbs
ACCESSORIES (INCLUDED)
1 x Island Trim
WARRANTY
Limited Warranty, Entire Appliance, Parts and Labor
*Height Includes Gas Connection
(USA)
x 25 13/16"
x 22 13/16"
Combustible Surface with Flush Island Trim
2 Year
PALPKITHN LP Conversion Kit
THERMADOR EXCLUSIVE
Page 1 of 4
PCG486NL
48-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
48-INCH RANGETOP AND CUTOUT DIMENSIONS
Page 2 of 4
PCG486NL
48-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
48-INCH RANGETOP CLEARANCE REQUIREMENTS
as dened in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certied by CSA. Clearances of less than 12” (305 mm) must be approved by the local codes and/or by the local authority having jurisdiction.
NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a ame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper.
Page 3 of 4
PCG486NL
48-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
ELECTRICAL AND GAS LOCATIONS
The gas and electrical supply must be located in an area that is accessible without requiring removal of the rangetop. The appliance electrical power cord and gas pipe connection are located on the left rear underside of the rangetop.
The junction box must be located within 3 feet (~900 mm) of the rangetop connection.
NATURAL GAS REQUIREMENTS:
Inlet Connection: 1/2" NPT (min. 3/4" dia. ex line) Supply Pressure: 6" min. to 14" max. water column (14.9 mb to 34.9 mb) Manifold Pressure: 5" water column (12.5 mb)
PROPANE GAS REQUIREMENTS:
Inlet Connection: 1/2" NPT (min. 3/4" dia. ex line) Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb)
These warranties give you specific legal rights and you may have ot her rights that vary from state to stat e. Full war ranty and limited warr anty from date of installation. For comp lete war ranty details, refe r to your Use & Care man ual, or as k your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model numbe r. Specif ications are correct a t time of pr inting. Thermador reserves t he right to change produc t spec ifications or design w ithout notice. Some models are certified for us e in Canada. Thermador is not respo nsible for products t hat are transported f rom the U.S. for use in Canada.
1 800 735 4 328 | USA THERMADOR.COM | CANADA THERMAD OR.CA | ©2015 BSH H OME APPLIANCES COR PORATION . ALL RIGH TS RESERVED. 05 / 15
Page 4 of 4
Loading...