Thermador PCG486GD/04, PCG486GD/02, PCG486GD/01, PCG304G-01, PCG486GD/03 Installation Guide

...
INSTALLATION MANUAL
For Thermador Professional ® Cooktops
MANUEL D'INSTALLATION
Des tables de cuisson Thermador Professional ®
MANUAL DE INSTALACION
Para Parrillas de Thermador Professional ®
Models/ Modeles/ Modelos: PCG30 PCG36
Table of Contents
Safety Instructions ............................ 2
Before you Begin ................................................. 2
Important Installation Information ............... 3
Step 1: Ventilation Requirements ............................................... 3
Step 2: Cabinet Preparation ................................................... 5
Step 3: Unpacking, Moving, Placing and Anchoring the Cooktop ...................... 10
Step 4: Gas Requirements and Hookup ......................................... 11
Step 5: Electrical Requirements, Connection and Grounding ......................... 12
Step 6: Backguard Installation ................................................. 13
Step 7: Burner Test and Adjustment ............................................ 13
Installer Checklist ............................................... 14
To Clean and Protect Exterior Surfaces ......... 15
This Thermador Appliance is made by
BSH Home Appliances Corporation
5551 McFadden Ave.
Huntington Beach, CA 92649
Questions?
1-800-735-4328
www.thermador.com
We look forward to hearing from you!
For Massachusetts Installations:
1. Installation must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region
where this appliance is being installed.
2. Shut-off valve must be a "T" handle gas cock.
3. Flexible gas connector must not be longer than 36 inches.
WARNING:
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
English 1
Safety Instructions
Important Safety Instructions
READ AND SAVE THESE INSTRUCTIONS
APPROVED FOR ALL RESIDENTIAL APPLIANCES
AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
FOR RESIDENTIAL USE ONLY
Before you Begin
IMPORTANT: Save these Instructions for the Local
Electrical Inspector's use. INSTALLER: Please leave these Instructions with this unit
for the owner. OWNER: Please retain these instructions for future
reference.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For
assistance or additional information consult a qualified installer, service agency, manufacturer
(dealer) or the gas supplier.
NOTE:
This Cooktop is NOT designed for installation in manufactured (mobile) homes or for installation in
Recreational Park Trailers.
DO NOT install this appliance outdoors.
Data Rating Plate
Cooktop Models:
The data rating plate showing the model and serial numbers of your cooktop is located on the underside of the cooktop chassis near the gas inlet connection and electric power cord. This information is required if customer service is requested. Before installation, the model and serial numbers should be entered in the appropriate spaces in
the "BEFORE CALLING FOR SERVICE" section near the back of the Care and Use Manual. After installation, accessing the information is difficult.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS,
Electrical Power Supply
30" Model: 4 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit
36" Models: 6 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit
4 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15 Amp circuit
48" Model: 6 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15
Amp circuit
Gas Supply Natural Gas - 6" min. to 14" max. water column (14.9 mb
to 34.9 mb) Propane Gas - 11"min. to 14"max. water column (27.4 mb to 34.9 mb)
WARNING
Disconnect power before installing. Before turning power ON, be sure that all controls are in the OFF position.
All sealed burners are rated at 18,000 BTU/HR ('15,000 BTU/HR on LP). *All models are convertible to LP/Propane gas using an accessory conversion kit.
IMPORTANT
A backguard must be utilized when there is less than a 12" horizontal clearance between combustible
materials and the back edge of the cooktop. The Thermador Low Back backguard must be ordered separately and installed at the rear of the cooktop. For
island installations and other installations with more than 12" clearance, an optional stainless steel Island
Trim is available to cover the backguard mounting flanges.
Verify that the appliance is correct for the type of gas
being provided. Refer to "Step 4: Gas Requirements and Hookup" on page 11 before proceeding with the
installation.
English 2
_j[__; _ii_11__ ...................................................................................................................................................................................................................................................................................................................................................................................................,_
Important Installation Information
It is stronqlv recommended that this appliance be installed in conjunction with a suitable overhead vent heed. (See "Step 1: Ventilation Requirements".)
Check local building codes for the proper method of appliance installation. Local codes vary. Installation, electrical connections and grounding must comply with all applicable codes. In the absence of local codes the appliance should be installed in accordance with the
National Electric Code ANSI Z223.1 current issue and National Gas Code ANSI/NFPA 70 - current issue. In
Canada, installation must be in accordance with the CAN
1-B149.1 and .2 - Installation Codes for Gas Burning
Appliances and/or local codes.
This appliance is equipped with an intermittent/interrupted ignition device that cycles the two far left surface burners on and off when in the ExtraLow setting.
CAUTION
(1) When connecting the unit to propane gas, make certain the propane gas tank is equipped with its own high-pressure regulator in addition to the pressure regulator supplied with this unit. The maximum gas pressure to this appliance is not to exceed 14.0 inches water column (34.9 mb) from the propane gas tank regulator.
CAUTION
To eliminate risk of burns or fire caused by reaching over heated surface units, cabinet storage located above the surface units should
be avoided.
Remove all tape and packaging before using the appliance. Destroy the packaging after unpacking the appliance. Never allow children to play with packaging material.
Step 1 Ventilation Requirements
It is stronqlv recommended that asuitable exhaust hood be installed above the appliance. Downdraft ventilation should not be used. The following table indicates the ventilation hood options and blower capacity guidelines that are recommended for use with all Thermador cooktops.
Due to the high heat capability of this unit, particular attention should be paid to the hood and duct work installation to assure it meets local building codes.
Do not install a microwave oven/ventilator combination above the cooktop, as these types of units do not provide
the proper ventilation and are not suitable for use with the cooktop.
(2) This unit is designed as a cooking appliance. Based on safety considerations, never use it for warming or heating a room.
Due to the high heat of the cooktop burners, installing a microwave oven with a ventilation system over the cooktop
is not recommended.
This appliance complies with one or more of the following standards:
UL 858, Standard for the Safety of Household Electric Ranges
UL 923, Standard for the Safety of Microwave Cooking Appliances
UL 507, Standard for the Safety of Electric Fans
ANSI Z21.1 American National Standard for Household Cooking Gas Appliances
CAN/CSA-C22.2 No. 113-M1984 Fans and Ventilators
CAN/CSA-C22.2 No. 61-M89 Household Cooking Ranges
It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
Select Hood and Blower Models:
For wall installations the hood width must, at a minimum, equal the nominal width of the appliance cooking surface. Where space permits, a hood larger in width than the cooking surface may be desirable for improved ventilation performance.
For island installations the hood width should, at a minimum, overhang the appliance cooking surface by
3" on each side.
Hood Placement:
For best smoke elimination, the lower edge of the hood should be installed 30" above the appliance cooking surface. (See Figure 1).
If the hood contains any combustible materials (i.e., a wood covering), it must be installed a minimum of 40" above the cooking surface.
NOTICE:
Most hoods contain combustible components which must be considered when planning the installation.
English 3
Consider Make-Up Air:
Due to the high volume of ventilation air, a source of outside replacement air is recommended. This is particularly important for tightly sealed and insulated
homes. A qualified heating and ventilating contractor should be
consulted.
NOTE:
Ventilation hoods and blowers are designed for use with single-wall ducting. Some local building codes may require double-wall ducting. Before starting installation, consult local building codes and agencies to insure that the installation will meet local requirements.
Cooktop Cooktop Minimum Recommended
Width Configuration Blower Capacity*
Ventilation Options
30" or 36" Pro Wall Hood
30" 4 burners 800 CFM
30" or 36" Custom Insert w/optional blower 42" Island Hood w/optional blower
36"
4 burners with griddle 6 burners
1000 CFM
1100 CFM
36" or 42" Pro Wall Hood 36" Custom Insert w/optional blower
42" or 48" Island Hood w/optional blower
48.... or 54" Pro Wall Hood
48"
6 burners with griddle
1300 CFM
48" Custom Insert w/optional blower 54" Island Hood w/optional blower
Important Notes:
It is recommended that a Thermador Professional wall or island hood or custom insert is used with Thermador Professional Cooktops.
Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and Accessories.
* For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is recommended. If the cooktop has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity may be required for longer duct runs.
For island applications, it is recommended to use a hood width that exceeds the width of the cooktop by 6" (overlapping the cooktop by 3" on each end).
**Not all 48" Pro Wall Hood models can accommodate a 1300 CFM blower option.
CFM = "cubic feet per minute" (standard blower capacity rating).
English 4
Step 2: Cabinet Preparation
1. To ensure professional results, the cabinet and countertop openings should be prepared by a qualified
cabinet worker.
2. The clearances shown in Figure 1 are required. The same clearances apply to island installations, except for the overhead cabinets, which must have a space wide enough to accept the island hood.
3. The cooktop is designed to hang from the countertop by its side flanges. The countertop however, must be strong enough to support this cooktop. It may be necessary to add a supporting cleat along each side (see Figure 2) or a 2 x 4 corner brace (see Figure 3 and Figure 4 and Detail A). Another alternative would be to construct a deck to set the cooktop on.
4. The cooktop can be installed in various positions with the front either flush or projecting, depending on the countertop's depth. (See Figure 5, side view of cooktop; see Figure 3, Figure 4, Figure 6 and Figure 7 for alternate mounting positions.)
5. The gas and electrical supply must be located in an area that is accessible without requiring removal of the cooktop. The appliance electrical power cord and gas pipe connection are located on the left rear underside of the cooktop, as shown in Figure 5 and Figure 9.
6. The maximum depth of over head cabinets installed on either side of the hood is 13".
A 40-inch minimum clearance is required between the cooking surface of the cooktop and the bottom of an unprotected cabinet. A 30-inch distance can be used when the bottom of the wood or metal cabinet is protected by not
less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4
mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020inch (0.5 mm) thick copper. Flame retardant
materials bear the mark:
UNDERWRITERS LABORATORIES INC. CLASSIFIED MINERAL AND FIBER BOARDS SURFACE BURNING CHARACTERISTICS
followed by the flame spread and smoke ratings. These designations are shown as "FHC (Flame Spread/Smoke Developed)." Materials with "O" flame spread ratings are flame retardant. Local codes may allow other flame spread ratings.
7. When there is less than a 12" horizontal clearance between combustible material /_ and the back edge of
the cooktop above the cooking surface, a Thermador Low Backguard must be installed. (See Step 6). When
clearance to combustible material/_ is over 12", a Thermador Island Trim may be used. Attach the
backguard before sliding the appliance into the final installed position.
8. Establish the centerline of the cooktop's desired location. It should be the same as the center of the
overhead ventilation hood.
,
Cut the openings for the following installations:
Wall installation, see Figure 3.
Island installation, see Figure 4.
10.
For installation of a 48" cooktop above two side-by-side Thermador Warming Drawers, Model No. WD24, refer to Figure 8. Completing the installation as per Figure 8
will result in the left and right edges of the cooktop
being aligned with the left edge of the left-side warming drawer and right edge of the right-side warming drawer. If different alignment is desired, the 1-7/8" horizontal distance between warming drawer cutouts may be
varied. However, maintain at least a 1-1/8" distance to avoid interference between the warming drawers.
Attach a 90-degree elbow to the gas cooktop inlet pipe. All above-the-countertop clearances must be maintained, as shown in Figure 1.
/_ As defined in the "National Fuel Gas Code" (ANSI
Z223.1/NFPA54-current issue).
NOTES:
If a solid side cabinet wall exists on one or both sides, you will need to notch the front corner of the cabinet to
match the countertop notch and to allow clearance for the cooktop front (see Detail A, Figure 3 and Figure 4).
If a supporting deck is used, the sides or bottom of the cutout may be solid combustible or non-combustible material. If the bottom is solid, provide a 8" by 8" cutout in the left rear corner of the supporting deck. This will provide clearance for the gas inlet and power cord, while also allowing viewing of the product rating label.
Always keep appliance area clean and free from combustible materials, gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air to the unit.
English 5
Fig.
!:i:i:i:i:i: i;?;i!!!;!!!
i_i_!;!;i;!i
:[:?:i:i:i:i
30"to36"WideHoodfor30"Cooktop 36"to42"WideHoodfor36"_
"_48"to60"WideHoodfor48"Cooktopt
VENT HOOD
Combustible Material ,/_
:':':':g4'
!Si:i:i:i:
5 ,;<°:':,
:!:;?::
i!i_?!i;iiii
!!i!iiiiiiiI
18" Min
®
13" Max.
depth of overhead "
cabinets
oth sides I..,,_
30" Min. from bottom of Overhead Hood to Cooking
Surface (40" or greater if hood contains combustible
materialsA).
O" Bottom
®
Horizontal Min. Clearance
to Rear Wall:
.//0" with Backguard
12"with Island Trim
/
_._J CookingSu_ace
_q
-_I--- O" Sides
!::_!i 40" Min.to
Material Z_ from Cooking
Surface.
English 6
Figure 1: Clearance Requirements
Counter Sunk
Screws
B
Figure 2: Installing Side Supports (both sides)
Vent Hood Width Requirements
Island - 42" or 48" Wide Hood for 36" Cooktop Island - 54" or 60" Wide Hood for 48" Cooktop
Figure 3: Wall Installation with Countertop Backsplash
Figure 4: Island Installation (No Countertop Backsplash)
English 7
7-11
...................................
C
2 x 4 Corner Support
A 29-7/8" 35-7/8" 47-7/8"
B 3/8" 3/8" 13/16"
C 0" (Control Panel Projecting 1-1/4" from Base
Cabinet Face)
11/16" (Notch Required for Standard 24" - Deep Base Cabinet, Control Panel Projecting 9/16" from Base Cabinet Face) 1-1/4" (Control Panel Flush to Cabinet Face- Min. 24-9/16"- Deep Base Cabinet Required)
Corner Notch Detail
Detail A: (Front Face of Cabinet)
_ 5-1/4" TO CENTERLINE OF ,,
| GAS INLET,,
,,___ 23-5/16 ----
1-1/4 I_--Cabinet face for installation with projecting control panel
/
t'_Cabinet face for installation with flush control panel
U 29-118"[35-118"146-114"
25-3/8"
1 2"
Side
Flange
7-5/8"
English 8
* Low Back required when there is less than 12" horizontal clearance from back of cooktop to combustible
material. With more than 12" of clearance, the Island
Trim may be used.
Figure 5: Side View of Cooktop
11/16" Notch
Depth
Front projects outward 9/16" as shown from
standard 24'Ldeep base.
Figure 6: Projecting from Cabinet Front
Minimum 3/4" (19 mm)
1-7/8" (4,8 cm) Horizontal Distance
Between Cutouts
2-3/4" (7 cm) Vertical Distance
Between Cutouts (See Side View for Wood Support)
Figure 8a: Installation of 48" Cooktop above two side-by-
side Thermador Warming Drawers - Model No. WD24
Front flush with cabinets; minimum of 24-9/16" cabinet depth required.
Figure 7: Flush to Cabinet Front
_7-11/16"
Plywood support _(19,52 cm)
I mm
_: Install additional _'
wood support along front edge of cutout
Figure 8b: Installation of 48" Cooktop above two side-by-side
Thermador Warming Drawers - Model No. WD24
D
2-3/4" (70 mm)
minimum
between
cutouts
(Side View)
English 9
" nds ust e "
__ ropane_as
......................j
3" Min.
"_ _ _ 3/4" flex line
Power
, a Cord or
/
3-Prong grounding type receptacle connected to a properly grounded and polarized electrical supply rated at 120VAC,
10 Amps, (or 15A*) Single Phase, 60 HZ.
All Installer supplied parts must conform to Local Codes. "15 Amp 120 VAC electrical supply is required for 36" and 48" models with an electric griddle.
A manual valve must be installed
external to the appliance, in an acces- sible location from the front, for the
purpose of shutting off the gas supply.
Figure 9: Bottom of Unit
Step 3: Unpacking, Moving, Placing and Anchoring the Cooktop
CAUTION
Proper equipment and adequate manpower must be used in moving the appliance to avoid damage and/or personal injury. The unit is heavy and should be handled accordingly.
Important
Verify that the appliance is correct for the type of gas
being provided. Refer to Step 4 before proceeding with the installation.
Attach the backguard before sliding the appliance into the final installed position. See Step 6.
Remove the outer carton and packing material from the shipping base. Ensure that you have all cooktop components before proceeding.
Remove the top grate castings and burner caps to reduce cooktop's weight.
NOTE:
Leave adhesive-backed foam layer over brushed-metal surfaces, to protect finish from scratches, until the cooktop
is installed in its final position.
Lift and place the cooktop in the opening. Be careful not to pinch the power cord or gas inlet. Care should be used not to scratch the griddle cooking plate.
Make sure that the power cord is free and hanging loose.
The cooktop must be level for proper performance. Replace the cooking grates and burner caps. Ensure
that the burner caps are correctly seated on the burner bases.
Griddle Tilt Adjustment (not all models) Check the griddle adjustment by pouring two tablespoons
of water on the back of the griddle plate. The water should slowly roll into the grease tray. If not, adjust the two screws under the back of the plate. Start with one half turn counter- clockwise (CCW) of the screws. Further adjustment should be made by one-quarter turn until water slowly flows into the grease tray.
English 10
Step 4: Gas Requirements and Hookup
Cooktops are shipped by the factory to operate on natural gas.They must be converted for use with propane, Verify the type of gas being used at the installation site matches the type of gas used by the
appliance. If the location/job site requires conversion from natural gas to propane (LP), contact the dealer where the unit was purchased or contact Thermador. The field conversion kit for the Professional Cooktops inthis series is Thermador Model PALPKITHC. Obey all instructions in this kit for correct conversion of the gas regulator and settings for the gas valves. Field conversion must be done by qualified service personnel only.
Natural Gas Requirements:
Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) Supply Pressure: 6" min. to 14" max. water column (14.9 to
34.9 mb) Manifold Pressure: 5" water column (12.5 mb)
Propane Gas Requirements:
The installer should inform the consumer of the location of the gas shut-off valve. Make sure all users
know where and how to shut off the gas supply to the cooktop.
The gas supply connections shall be made by a competent technician and in accordance with local
codes or ordinances. In the absence of local codes, the installation must conform to the National Fuel Gas
Code ANSI Z223.1/NFPA54-current issue. Always use pipe-sealing compound or Teflon® tape on
the pipe threads, and be careful not to apply excessive pressure when tightening the fittings.
Leak testing of the appliance shall be in accordance
with the following instructions.
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Bubbles forming indicate a gas leak. Repair all
leaks immediately after finding them.
WARNINGDo not use a flame of any kind to check for gas
leaks.
Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb)
WARNING
If a gas conversion kit is used, the kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in the instructions is not followed
exactly, afire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper
installation of the kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions supplied with the
kit.
Hook Up
A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit. Make sure the gas supply is turned off at the manual shut-off valve before connecting the appliance.
All installer-supplied parts must conform to
applicable codes.
CAUTION
When connecting unit to propane gas, make certain the propane gas tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the appliance. The pressure of the gas supplied to the appliance regulator must not exceed a 14" water column (34.9 mb).
CAUTION
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa.).
When checking the manifold gas pressure, the inlet pressure to the regulator should be at least
6.0" W.C. for natural gas or 11.0" for propane. Do not attempt any adjustment of the pressure
regulator.
English 11
Step 5: Electrical Requirements, Connection and Grounding
CAUTION
Improper grounding or reverse polarization will cause malfunction (such as continuous sparking of the burner igniters). This can damage the appliance and can create a condition of shock hazard. If the circuit is not correctly grounded and polarized, it is the responsibility and obligation of the installer and user to have the existing receptacle changed to a properly grounded and polarized receptacle. This must be accomplished in accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle replacement shall be in accordance with the National Electric Code. (See Figure 10.)
Grounding Method
The cooktop is factory equipped with a power supply cord
with a three-prong grounding plug (with polarized parallel
blades).
IT MUST BE PLUGGED INTO A MATING, GROUNDING TYPE RECEPTACLE THAT IS CONNECTED TO A
CORRECTLY POLARIZED 120 VOLT CIRCUIT (See Figure 10).
Before installing, turn power OFF at the service panel. Lock service panel to prevent power from being turned ON accidentally.
Always disconnect appliance from the electric supply either by disconnecting power cord or shutting off the breaker before servicing the appliance.
Before you plug in an electrical cord, be sure all controls are in the OFF position.
All 120 Volt cooktop models must be plugged into a mating 3-Prong, Grounding-Type Receptacle. The receptacle must be connected to a properly grounded and polarized electrical power supply rated at 120VAC, Single Phase, 60HZ. See "Electrical Power Supply Over-current Protection Requirements" on page 12 for proper over-current protection requirements for each
model.
Observe all governing codes and ordinances when grounding. In the absence of these codes or
ordinances observe National Electrical Code ANSI/ NFPA No. 70 current issue. See Figure 10 for
recommended grounding method.
An electrical wiring diagram and schematic have been attached to the bottom of the cooktop chassis for access by a qualified service technician. Do not remove or discard this important information.
THREE-PRONG
PLUG
Figure 10: Recommended Grounding Method for 120V
Models
THE THIRD, GROUND PRONG MUST NOT BE CUT OR REMOVED UNDER ANY CIRCUMSTANCES.
NOTE: If the 120V cooktop is installed and connected as specified
above, it will be completely grounded in compliance with the National Electric Code.
Electrical Power Supply Over-current Protection Requirements
4 Burners - 10 Amp circuit protection
6 Burners - 10 Amp circuit protection
4 Burners with electric griddle - 15 Amp circuit protection
6 Burners with electric griddle -15 Amp circuit protection
Installer - show the owner the location of the circuit breaker or fuse. Mark it for easy reference.
English 12
Step 6: Backguard Installation
A Low Back backguard must be installed when there is less than a 12" clearance between combustible materials and
back edge of cooktop. (See Figure 1 and Figure 5.) For island installations and other installations with over 12"
clearance, an optional stainless steel trim channel is available to cover the backguard mounting flanges. Attach
the backguard before sliding the appliance into the final installed position. Follow Steps A through C below:
z" °
c 4./
=
1. Slide backguard over the two flanges on the rear of the appliance. Fasten the front and back with the two
A
screws (see A, Figure 11) provided.
2. Fasten the top of the backguard to the wall with two screws through the backguard. (See B, Figure 11.)
\
3. Place the backguard cap on top and fasten using the two counter-sink screws provided. (See C, Figure 11.)
Figure 11: Low Back Attachment
Cooktop Size/Type 12" Low Back Island Trim*
30" PA30G LBC PA30G ITC 36" PA36G LBC PA36G ITC
48" PA48GLBC PA48GITC *Requires a minimum of 12" horizontal clearance between back of appliance and combustible materials.
Step 7: Burner Test and Adjustment
Install any loose components, such as burner caps and grates that may have been removed earlier. Be certain that burner caps seat properly into the burner bases. Before testing operation of the appliance, verify that the unit and the gas supply have been carefully checked for
leaks and that the unit has been connected to the electrical power supply. Turn the manual gas shut-off valve to the
open position.
Test Cooktop Burners Test Burner Ignition. Select a cooktop burner knob. Push
in and turn counterclockwise to HI. The ignitor/spark module will produce a clicking sound. Once the air has been purged from the supply lines, the burner should light within four (4) seconds.
Test Flame: High Setting. Turn burner on to HI. See Figure 12 for appropriate flame characteristics. If any of the cooktop burners continue to burn mostly or completely yellow, verify that the burner cap is positioned properly on
the burner base, then re-test. If flame characteristics do not improve, call Thermador.
Test Flame: Low Setting. Turn burner on to LO. Verify that the flame completely surrounds the burner. There should be a flame at each burner port and there should be no air gap between the flame and the burner. Ifany burners do not carry over, call Thermador.
The two far left burners feature XLO, causing the flame to cycle on and off when the knob is set to the XLO range. This is normal operation.
Repeat the Ignition and Flame Test procedures described above for each cooktop burner.
English 13
Installer Checklist
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the regulator is set for the correct fuel. After adjustment,
retest. Some orange-colored streaking is normal during the
initial start-up. Allow unit to operate 4-5 minutes and re-evaluate before making adjustments.
Figure 12: Flame Characteristics
WHEN FLAME IS PROPERLY ADJUSTED:
There should be a flame at each burner port.
There should be no air gap between the flame and
burner port.
Final Check List
Cooktop correctly positioned in countertop recess.
Specified clearances maintained to cabinet surfaces.
Burner caps positioned properly on burner bases.
All packaging material removed.
Island Trim or Backguard attached according to instructions.
The griddle plate tilted slightly forward. (See "Griddle Tilt Adjustment (not all models)" on page 10.)
Gas Supply
Connection: 1/2" NPT with a minimum 3/4" diameter flex line.
If converting from natural to LP gas, refer to LP Conversion Instructions for details.
Manual gas shut off valve installed in an accessible location (without requiring removal of appliance).
Unit tested and free of gas leaks.
Electrical
Call Thermador if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
For models with the electric griddle, a polarized and grounded 120VAC receptacle with 15 AMP over current protection is provided for service cord
connection.
Operation
All internal packing materials removed. (Check below grates and grill pans.)
Bezels centered on burner knobs, and knobs turn freely.
Purge air from gas system by operating one of the top burners for several minutes.
Each burner lights satisfactorily, both individually and with other burners operating.
Burner grates are correctly positioned.
Installer
Give CARE and USE MANUAL and INSTALLATION
INSTRUCTIONS to your customer.
English 14