Safety
Important Safety Instructions
m
READ AND SAVE THESE INSTRUCTIONS
Appliance Handling Safety
Safety Codes and Standards
WARNING: If the information in this manual is not followed exactly, fire or shock may result causing property damage or personal injury.
WARNING: Do not repair or replace any part of the appliance unless specifically recommended in the manuals. Improper installation, service or maintenance can cause injury or property damage. Refer to this manual for guidance. All other ser­vicing should be done by a qualified technician.
Do not lift appliance by door handle. Remove the door for easier handling and in­stallation. See instructions in Use and Care Manual.
Unit is heavy and requires at least two people or proper equipment to move. Hidden surfaces may have sharp edges. Use caution when reaching behind or un-
der appliance.
This appliance complies with one or more of the following Standards:
UL 858, The Standard for the Safety of Household Electric Ranges
UL 923, The Standard for the Safety of Microwave Cooking Appliances
UL 507, The Standard for the Safety of Electric Fans
ANSI Z21.1, The American National Standard for Household Cooking Gas Ap-
pliances
CAN/CSA-C22.2 No. 113-M1984 Fans and Ventilators
CAN/CSA-C22.2 No. 61-M89 Household Cooking Ranges
It is the responsibility of the owner and the installer to determine if additional re­quirements and/or standards apply to specific installations.
Electric Safety
Before you plug in an electrical cord, be sure all controls are in the OFF position. If required by the National Electrical Code (or Canadian Electrical Code), this ap-
pliance must be installed on a separate branch circuit. Installer - show the owner the location of the circuit breaker or fuse. Mark it for easy
reference. Important - Save these instructions for the local electrical inspector's use. Before installing, turn power OFF at the service panel. Lock service panel to pre-
vent power from being turned ON accidentally. Refer to data plate for more information. See "Product Data Plate" under "Service"
for data plate location. Be sure your appliance is properly installed and grounded by a qualified technician.
Installation, electrical connections and grounding must comply with all applicable codes.
3
Important Safety Instructions
m
READ AND SAVE THESE INSTRUCTIONS
Related Equipment Safety
Transport
Remove all tape and packaging before using the appliance. Destroy the packaging after unpacking the appliance. Never allow children to play with packaging materi­al.
Never modify or alter the construction of the appliance. For example, do not re­move leveling legs, panels, wire covers or anti-tip brackets/screws.
To avoid damage to the oven vent, use the transport method shown in the picture below.
4
Installation
Before you Begin
Tools and Parts Needed
Parts Included
27” Appliances
General Information
Power Requirements
Dimensions for 27” Wall-Mounted Units
Phillips head screwdriver
Measuring tape
Drill with bit (1/8")
Phillips head screws (6)
The outlet must be properly grounded in accordance with all applicable codes.
Single Oven 27”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be in­stalled either above or below the unit. If the conduit box is installed below the unit, a 2” diameter hole or space is re­quired between the back wall and the right rear of the 2x4 supports.
The cabinet base must be flat and capable of supporting a weight of at least 210 lbs (95 kg).
5
Double Oven 27”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 355 lbs (161 kg).
Combo Oven with Microwave 27”
It is good practice, when oven is in-
stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 330 lbs (150 kg).
6
Combo Oven with Microwave and Warming Drawer 27”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 370 lbs (168 kg).
7
27” Under-the-counter units
A single oven installed under the counter allows for the installation of most Thermador Gas or Electric non-Cook’n’Vent® Model Cook­tops. Downdraft units cannot be in­stalled in this configuration; Thermador overhead ventilation is recommended.
Some TMH cooktops require addi­tional clearances to combustible walls.
A Thermador cooktop should be in­stalled on the same center line as the under-the-counter single oven. Follow the installation instructions provided with cooktop for installa­tion of cooktops. 3 3/4” (95 mm) minimum is required from the top of the countertop to the top of the cut­out opening for under-counter in­stallation with Thermador cooktops. If the type of cabinet or countertop thickness does not provide for this minimum space, the cabinet base may have to be lowered, into the toe space, to provide the necessary space above the oven. However, a 4” minimum distance between the floor and the oven bottom must re­main.
8
30” Appliances
Dimensions for 30” Wall-Mounted Units
Single Oven 30”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be in­stalled either above or below the unit. If the conduit box is installed below the unit, a 2” diameter hole or space is re­quired between the back wall and the right rear of the 2x4 supports.
The cabinet base must be flat and capable of supporting a weight of at least 190 lbs (86 kg).
9
Double Oven 30”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 330 lbs (150 kg).
Combo Oven with Microwave 30”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 290 lbs (132 kg).
10
Combo Oven with Microwave and Warming Drawer 30”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 310 lbs (141 kg).
Combo Oven with Warming Drawer 30”
It is good practice, when oven is in­stalled at the end of a cabinet run, ad­jacent to a perpendicular wall or cabinet door, to allow at least 1/4” space between the side of the oven and the wall/door.
For oven support, install 2x4’s extend­ing front to back flush with the bottom and the side of the opening. The sup­porting base must be well secured to the floor/cabinet and level.
Note: The conduit box must be located above the unit to facilitate connecting and servicing.
The cabinet base must be flat and capable of supporting a weight of at least 290 lbs (132 kg).
11
30” Under-the-counter-Units
A single oven installed under the counter allows for the installation of most Thermador Gas or Electric non-Cook’n’Vent® Model Cook­tops. Downdraft units cannot be installed in this configuration; Thermador overhead ventilation is recommended.
Some TMH cooktops require addi­tional clearances to combustible walls.
A Thermador cooktop should be installed on the same center line as the under-the-counter single oven. Follow the installation in­structions provided with cooktop for installation of cooktops. 3 3/4” inches (95mm) minimum is re­quired from the top of the counter­top to the top of the cutout opening for under-counter installation with Thermador cooktops. If the type of cabinet or countertop thickness does not provide for this minimum space, the cabinet base may have to be lowered, into the toe space, to provide the necessary space above the oven. However, a 4” minimum distance between the floor and the oven bottom must re­main.
12
Electrical Installation
All model ovens on the front cover are dual rated, designed to be connected to ei­ther 208/240V AC, 60 Hz, 4 wire, single-phase power supply.
Model Circuit Required
M271, M301 25 AMP 30 AMP
208V, 60 Hz 240V, 60 Hz
ME301, MEW301 ME271, PO301,
POD301, DE301, DEC301
ME302, MED302 ME272, MED272,
PO302, POD302, PODC302, DE302, MEM271, MEM301, POM301, MEMC301, MEMCW301, MEMW271, MEMW301, POMW301
The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit box (not furnished).
Important: Local Codes may vary, installation, electrical connections and ground­ing must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect both the white neutral wire and the bare ground wire from the oven to the white neutral electrical supply wire.
Electrical Connection
1. Connect the red oven wire to the red electrical supply wire (hot wire).
2. Connect the black oven wire to the black electrical supply wire (hot wire).
3. Connect the white neutral oven wire to the white neutral (not bare ground)
electrical supply wire.
4. Connect the bare ground oven wire to the bare ground electrical supply wire.
The conduit cable, where connected at the oven, swivels. Rotate conduit cable up­ward (or downward) and direct through hole prepared in cabinet to attach to J-Box.
To facilitate maintain serviceability, the flex conduit must not be shortened and should be routed to permit temporary removal of the oven.
30 AMP 30 AMP
40 or 50 Amp circuit. Refer to local electrical codes for de-rating requirements.
13
Installing the Oven
Note: Before installing the oven be sure to verify the cabinet dimensions and elec-
trical connections.
Removing the Oven Door
For ease of installation, some oven doors may be removed to reduce the weight of the oven by 30 lbs (14 kg) per door, before installing into the cabinet. See instruc­tions below.
CAUTION: When removing the door:
m
Make sure oven is cool and power to the oven has been turned off
before removing the door. Failure to do so could result in electrical shock or burns.
The oven door is heavy and fragile. Use both hands to remove the
oven door. The door front is glass. Handle carefully to avoid breaking.
Grasp only the sides of the oven door. Do not grasp the handle as
it may swing in your hand and cause damage or injury.
Failure to grasp the oven door firmly and properly could result in
personal injury or product damage.
To avoid injury from hinge bracket snapping closed, be sure that
both levers are securely in place before removing the door. Also, do not force door open or closed - the hinge could be damaged and injury could result.
To remove the oven door:
1. Be sure to read the above CAUTION
before attempting to remove the door.
2. Open the door completely.
3. Flip levers on hinges toward you.
4. Close door carefully until it stops. It will
be about half way closed.
5. Holding the door firmly on both sides using both hands, pull the door up and out of the hinge slots. Hold firmly; the door is heavy.
6. Place the door in a convenient and sta­ble location for cleaning.