![](/html/95/953c/953ccbc9942dd0f0e154c79bcef2c3854461b2d78225814b4d0c8d846ffc81fa/bg1.png)
VRE210
Precision Surface Mount
Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
• PIN AND FUNCTION COMPATIBLE WITH REF01
• VERY HIGH ACCURACY: 10.000 V OUTPUT ±0.3 mV
• EXTREMELY LOW DRIFT: 0.5 ppm/°C 55°C to +125°C
• LOW WARM-UP DRIFT: 1 ppm Typ.
• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
• EXCELLENT LINE REGULATION: 3 ppm/V Typ.
• HERMETIC 20 TERMINAL CERAMIC LCC
• MILITARY PROCESSING OPTION
DESCRIPTION
VRE210 Series Precision Voltage References
provide ultrastable +10.000V outputs with ±0.3
mV initial accuracy and temperature coefficient
as low as 0.5 ppm/°C over the full military
temperature range. This improvement in
accuracy is made possible by a unique,
proprietary multipoint laser compensation
technique developed by Thaler Corporation.
Significant improvements have been made in
other performance parameters as well, including
initial accuracy, warm-up drift, line regulation, and
long-term stability, making the VRE210 series the
most accurate and stable 10V surface mount
references available.
APPLICATIONS
• PRECISION A/D and D/A CONVERTERS
• TRANSDUCER EXCITATION
• ACCURATE COMPARATOR THRESHOLD
REFERENCE
• HIGH RESOLUTION SERVO SYSTEMS
• DIGITAL VOLTMETERS
• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
SELECTION GUIDE
Type
VRE210C +10V -25°C to +85°C 0.6mV
VRE210CA +10V -25°C to +85°C 0.3mV
VRE210M +10V -55°C to +125°C 1.0mV
VRE210MA +10V -55°C to +125°C 0.5mV
Output
Temperature
Operating Range
Max. Volt
Deviation
VRE210 devices are available in two operating
temperature ranges, -25°C to +85°C and -55°C to
+125°C, and two electrical performance grades.
All devices are packaged in 20 terminal ceramic
LCC packages for maximum long-term stability.
"M" versions are screened for high reliability and
quality.
VRE210DS REV. C JUNE 1995
![](/html/95/953c/953ccbc9942dd0f0e154c79bcef2c3854461b2d78225814b4d0c8d846ffc81fa/bg2.png)
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10KΩ unless otherwise noted.
VRE210
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply +13.5 +22 * * * * * * V
Operating Temperature -25 85 * * -55 125 -55 125 °C
Storage Temperature -65 150 * * * * * * °C
Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE210 +10 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 500 300 800 400 µV
Warmup Drift 2 1 2 1 ppm
T
- T
min
max
(1)
600 300 1000 500 µV
Long-Term Stability 6 * * * ppm/1000hrs
Noise (.1-10Hz) 6 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 3 10 * * * * * * ppm/V
Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 20 * * * mV
Temperature Coeff. 4 * * * mV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE210 +PS 5 7 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the
maximum deviation from the output voltage at 25°C
over the specified operating temperature range.
2.The specified values are unloaded.