THALER VRE118C, VRE117MA, VRE117M, VRE117CA, VRE117C Datasheet

...
0 (0)
THALER VRE118C, VRE117MA, VRE117M, VRE117CA, VRE117C Datasheet

VRE117/118/119

Precision

Reference Supplies

THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000

FEATURES

VERY HIGH ACCURACY: 3.000 V OUTPUT ±200 µV

EXTREMELY LOW DRIFT: 0.6 ppm/°C 55°C to +125°C

LOW WARM-UP DRIFT: 1 ppm Typ.

EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.

EXCELLENT LINE REGULATION: 3 ppm/V Typ.

HERMETIC 14-PIN CERAMIC DIP

MILITARY PROCESSING OPTION

APPLICATIONS

PRECISION A/D and D/A CONVERTERS

TRANSDUCER EXCITATION

ACCURATE COMPARATOR THRESHOLD REFERENCE

HIGH RESOLUTION SERVO SYSTEMS

DIGITAL VOLTMETERS

HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS

DESCRIPTION

VRE117 Series

Precision

Voltage

References

 

SELECTION GUIDE

 

provide ultrastable +3.000V (VRE117), -3.000V

 

 

 

 

 

 

(VRE118)

and

±3.000V (VRE119)

outputs with

Type

Output

Temperature

Max. Volt

±0.200 mV initial accuracy and temperature

Operating Range

Deviation

coefficient

as

low as

0.6

ppm/°C

over the full

 

 

 

 

VRE117C

+3.0V

-25°C to +85°C

200 µV

military temperature range. This improvement in

VRE117CA

+3.0V

-25°C to +85°C

100 µV

accuracy

is

made

possible

by

a

unique,

VRE117M

+3.0V

-55°C to +125°C

400 µV

proprietary

multipoint

laser

compensation

VRE117MA

+3.0V

-55°C to +125°C

200 µV

technique developed by Thaler Corporation.

 

 

 

 

Significant improvements have been made in

VRE118C

-3.0V

-25°C to +85°C

200 µV

other performance parameters as well, including

VRE118CA

-3.0V

-25°C to +85°C

100 µV

initial accuracy, warm-up drift, line regulation, and

VRE118M

-3.0V

-55°C to +125°C

400 µV

long-term stability, making the VRE117 series the

VRE118MA

-3.0V

-55°C to +125°C

200 µV

most accurate

and

stable

3.0V

reference

 

 

 

 

VRE119C

±3.0V

-25°C to +85°C

200 µV

available.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE119CA

±3.0V

-25°C to +85°C

100 µV

 

 

 

 

 

 

 

 

 

VRE117/118/119 devices are available in two

VRE119M

±3.0V

-55°C to +125°C

400 µV

operating

temperature

ranges,

-25°C

to +85°C

VRE119MA

±3.0V

-55°C to +125°C

200 µV

and -55°C to +125°C, and two performance

grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.

Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.

VRE117DS REV. C NOV 2000

 

ELECTRICAL SPECIFICATIONS

 

 

 

 

 

 

 

VRE117/118/119

 

 

Vps =±15V, T = 25°C, RL = 10k? unless otherwise noted.

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

 

C

 

 

CA

 

 

M

 

 

MA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETERS

MIN

TYP

MAX

MIN

TYP

MAX

MIN

TYP

MAX

MIN

TYP

MAX

UNITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABSOLUTE MAXIMUM RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

±13.5

 

 

±22

*

 

*

*

 

*

*

 

*

V

 

 

Operating Temperature

-25

 

 

85

*

 

*

-55

 

125

-55

 

125

°C

 

 

Storage Temperature

-65

 

 

150

*

 

*

*

 

*

*

 

*

°C

 

 

Short Circuit Protection

Continuous

 

*

 

 

*

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE117

 

+3.0

 

 

*

 

 

*

 

 

*

 

V

 

 

VRE118

 

-3.0

 

 

*

 

 

*

 

 

*

 

V

 

 

VRE119

 

±3.0

 

 

*

 

 

*

 

 

*

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT VOLTAGE ERRORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial Error

 

 

 

300

 

 

200

 

 

300

 

 

200

µV

 

 

Warmup Drift

 

 

2

 

 

1

 

 

2

 

 

1

 

ppm

 

 

Tmin - Tmax (1)

 

 

 

200

 

 

100

 

 

400

 

 

200

µV

 

 

Long-Term Stability

 

 

6

 

 

*

 

 

*

 

 

*

 

ppm/1000hr.

 

 

Noise (.1-10Hz)

 

 

1.5

 

 

*

 

 

*

 

 

*

 

µVpp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

±10

 

 

 

*

 

 

*

 

 

*

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REGULATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

 

 

3

10

 

*

*

 

*

*

 

*

*

ppm/V

 

 

Load

 

 

3

 

 

*

 

 

*

 

 

*

 

ppm/mA

 

 

OUTPUT ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

 

5

 

 

*

 

 

*

 

 

*

 

mV

 

 

Temperature Coefficient

 

 

1

 

 

*

 

 

*

 

 

*

 

µV/°C/mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY CURRENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE117 +PS/ -PS

 

5

7

 

*

*

 

*

*

 

*

*

mA

 

 

VRE119 +PS

 

7

9

 

*

*

 

*

*

 

*

*

mA

 

 

VRE118/119 -PS

 

4

6

 

*

*

 

*

*

 

*

*

mA

 

NOTES: *Same as C Models.

1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.

2.The specified values are unloaded.

VRE117DS REV. C NOV 2000