FEATURES

VERY HIGH ACCURACY: 1.500 V OUTPUT ±150 µV

EXTREMELY LOW DRIFT: 0.8 ppm/°C 55°C to +125°C

LOW WARM-UP DRIFT: 1 ppm Typ.

EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.

EXCELLENT LINE REGULATION: 3 ppm/V Typ.

HERMETIC 14-PIN CERAMIC DIP

MILITARY PROCESSING OPTION

APPLICATIONS

PRECISION A/D and D/A CONVERTERS

TRANSDUCER EXCITATION

ACCURATE COMPARATOR THRESHOLD REFERENCE

HIGH RESOLUTION SERVO SYSTEMS

DIGITAL VOLTMETERS

HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS

DESCRIPTION

VRE114 Series

Precision

Voltage

References

 

SELECTION GUIDE

 

 

 

provide ultrastable +1.500V (VRE114), -1.500V

 

 

 

 

 

 

 

 

 

 

(VRE115)

and

±1.500V (VRE116)

outputs with

Type

Output

Temperature

Max. Volt

±150 µV initial accuracy and temperature

Operating Range

Deviation

coefficient

as

low as

0.8

ppm/°C

over the full

 

 

 

 

 

 

VRE114C

+1.5V

-25°C to +85°C

150

µV

military temperature range. This improvement in

VRE114CA

+1.5V

-25°C to +85°C

75

µV

accuracy

is

made

possible

by

a

unique,

VRE114M

+1.5V

-55°C to +125°C

240 µV

proprietary

multipoint

laser

compensation

VRE114MA

+1.5V

-55°C to +125°C

120

µV

technique developed by Thaler Corporation.

 

 

 

 

 

 

Significant improvements have been made in

VRE115C

-1.5V

-25°C to +85°C

150

µV

other performance parameters as well, including

VRE115CA

-1.5V

-25°C to +85°C

75

µV

initial accuracy, warm-up drift, line regulation, and

VRE115M

-1.5V

-55°C to +125°C

240 µV

long-term stability, making the VRE114 series the

VRE115MA

-1.5V

-55°C to +125°C

120 µV

most accurate

and

stable

1.5V

reference

 

 

 

 

 

 

VRE116C

±1.5V

-25°C to +85°C

150

µV

available.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE116CA

±1.5V

-25°C to +85°C

75

µV

 

 

 

 

 

 

 

 

 

VRE114/115/116 devices are available in two

VRE116M

±1.5V

-55°C to +125°C

240 µV

operating

temperature

ranges,

-25°C

to +85°C

VRE116MA

±1.5V

-55°C to +125°C

120

µV

and -55°C to +125°C, and two performance

grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.

Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.

VRE114DS REV. C NOV 2000

 

SPECIFICATIONS

 

 

 

 

 

 

 

 

VRE114/115/116

 

ELECTRICAL

 

 

 

 

 

 

 

 

 

 

 

 

Vps =±15V, T = 25°C, RL = 10k? unless otherwise noted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

 

C

 

 

CA

 

 

M

 

 

MA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETERS

MIN

TYP

MAX

MIN

TYP

MAX

MIN

TYP

MAX

MIN

TYP

MAX

UNITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABSOLUTE MAXIMUM RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

±13.5

 

 

±22

*

 

*

*

 

*

*

 

*

V

 

Operating Temperature

-25

 

 

85

*

 

*

-55

 

125

-55

 

125

°C

 

Storage Temperature

-65

 

 

150

*

 

*

*

 

*

*

 

*

°C

 

 

 

 

 

 

 

Short Circuit Protection

Continuous

 

*

 

 

*

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE114

 

+1.5

 

 

*

 

 

*

 

 

*

 

V

 

VRE115

 

-1.5

 

 

*

 

 

*

 

 

*

 

V

 

VRE116

 

±1.5

 

 

*

 

 

*

 

 

*

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT VOLTAGE ERRORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial Error

 

 

 

300

 

 

150

 

 

300

 

 

150

µV

 

Warmup Drift

 

 

2

 

 

1

 

 

2

 

 

1

 

ppm

 

Tmin - Tmax (1)

 

 

 

150

 

 

75

 

 

240

 

 

120

µV

 

Long-Term Stability

 

 

6

 

 

*

 

 

*

 

 

*

 

ppm/1000hr.

 

Noise (.1-10Hz)

 

 

1.0

 

 

*

 

 

*

 

 

*

 

µVpp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

±10

 

 

 

*

 

 

*

 

 

*

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REGULATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

 

 

3

10

 

*

*

 

*

*

 

*

*

ppm/V

 

Load

 

 

3

 

 

*

 

 

*

 

 

*

 

ppm/mA

 

OUTPUT ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

 

5

 

 

*

 

 

*

 

 

*

 

mV

 

Temperature Coefficient

 

 

1

 

 

*

 

 

*

 

 

*

 

µV/°C/mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY CURRENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

VRE114 +PS/ -PS

 

5

7

 

*

*

 

*

*

 

*

*

mA

 

VRE116 +PS

 

7

9

 

*

*

 

*

*

 

*

*

mA

 

VRE115/116 -PS

 

4

6

 

*

*

 

*

*

 

*

*

mA

NOTES: *Same as C Models.

1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.

2.The specified values are unloaded.

VRE114DS REV. C NOV 2000