FEATURES
•• VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV
•• EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C
•• EXCELLENT STABILITY: 6ppm/1000 Hrs. Typ.
•• EXCELLENT LINE REGULATION: 6 ppm/V Typ.
•• WIDE SUPPLY RANGE: +13.5 V to +22.0 V
•• HERMETIC 20 TERMINAL CERAMIC LCC
•• MILITARY PROCESSING AVAILABLE
DESCRIPTION
VRE204 Series Precision Voltage References provide ultrastable +4.500 V outputs with up to ±0.4 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range.
APPLICATIONS
•• PRECISION A/D and D/A CONVERTERS
•• TRANSDUCER EXCITATION
•• ACCURATE COMPARATOR THRESHOLD
REFERENCE
•• HIGH RESOLUTION SERVO SYSTEMS
•• DIGITAL VOLTMETERS
•• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
SELECTION GUIDE
These references are specifically designed to be used with the Crystal Semiconductor line of successive-approximation type Analog-to-Digital Converters (ADCs). This line of ADCs sets new standards for temperature drift, which can only be as good as the external reference used. The Thaler VRE204 combined with a Crystal ADC will provide the lowest drift data conversion obtainable.
VRE204 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two performance grades. All devices are packaged in 20 terminal LCC ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make the VRE204 ideal for all precision applications which may require a 4.5V reference. High-accuracy test and measurement instrumentation, and transducer excitation are some other applications which can benefit from the high accuracy of the VRE204.
Type
VRE204C +4.5V -25°C to +85°C 0.4mV VRE204CA +4.5V -25°C to +85°C 0.2mV
VRE204M +4.5V -55°C to +125°C 0.6mV VRE204MA +4.5V -55°C to +125°C 0.3mV
Output
Temperature
Operating Range
VRE204DS REV. C JUNE 1995
Max. Volt Deviation
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10K unless otherwise noted.
VRE204
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply +13.5 +22 * * * * * * V Operating Temperature -25 85 * * -55 125 -55 125 °C Storage Temperature -65 150 * * * * * * °C Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE204 +4.5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 800 400 800 400 µV Warmup Drift 2 1 2 * ppm T
- T
min
max
(1)
400 200 600 300 µV Long-Term Stability 6 * * * ppm/1000hrs Noise (.1-10Hz) 3 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 6 10 * * * * * * ppm/V Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 10 * * * mV Temperature Coeff. 4 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE204 +PS 5 7 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.
2.The specified values are unloaded.
VRE204DS REV. C JUNE 1995
Loading...