THALER VRE202MA, VRE202M, VRE202CA, VRE202C Datasheet

VRE202
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
VERY HIGH ACCURACY: 2.5000 V OUTPUT ±200 µV
EXTREMELY LOW DRIFT: 0.6 ppm/°C 55°C to +125°C
LOW WARM-UP DRIFT: 1 ppm Typ.
EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
EXCELLENT LINE REGULATION: 6ppm/V Typ.
HERMETIC 20 TERMINAL CERAMIC LCC
MILITARY PROCESSING OPTION
DESCRIPTION
VRE202 Series Precision Voltage References provide ultrastable +2.5000V outputs with ±200 µV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range. This improvement in accuracy is made possible by a unique, proprietary multipoint laser compensation technique developed by Thaler Corporation. Significant improvements have been made in other performance parameters as well, including initial accuracy, warm-up drift, line regulation, and long­term stability, making the VRE202 series the most accurate and stable 2.5V surface mount references available.
VRE202 devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two electrical performance grades. All devices are packaged in 20 terminal ceramic LCC packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
APPLICATIONS
PRECISION A/D and D/A CONVERTERS
TRANSDUCER EXCITATION
ACCURATE COMPARATOR THRESHOLD
REFERENCE
HIGH RESOLUTION SERVO SYSTEMS
DIGITAL VOLTMETERS
HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
SELECTION GUIDE
Type
VRE202C +2.5V -25°C to +85°C 200µV VRE202CA +2.5V -25°C to +85°C 100µV
VRE202M +2.5V -55°C to +125°C 400µV VRE202MA +2.5V -55°C to +125°C 200µV
Output
Temperature
Operating Range
Max. Volt Deviation
VRE202DS REV. D NOV 2000
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10k? unless otherwise noted.
VRE202
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply +13.5 +22 * * * * * * V Operating Temperature -25 85 * * -55 125 -55 125 °C Storage Temperature -65 150 * * * * * * °C Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE202 +2.5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 300 200 300 200 µV Warmup Drift 2 1 2 1 ppm T
- T
min
max
(1)
200 100 400 200 µV Long-Term Stability 6 * * * ppm/1000hrs Noise (.1-10Hz) 1.5 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 6 10 * * * * * * ppm/V Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 10 * * * mV Temperature Coeff. 4 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE202 +PS 5 7 * * * * * * mA VRE202 -PS 5 7 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.
2.The specified values are unloaded.
VRE202DS REV. D NOV 2000
Loading...