THALER VRE127MA, VRE127M, VRE127CA, VRE127C, VRE125MA Datasheet

...
VRE125/127
Precision High Temperature Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
•• WIDE OPERATING RANGE: -55°C to +200°C
•• VERY HIGH ACCURACY: 5.000 V ±0.4 mV
•• EXTREMELY LOW DRIFT: 0.6 mV (-55°C to +150°C)
•• EXCELLENT STABILITY: 6 ppm / 1000Hrs.
•• HERMETIC 14-PIN DIP
2.0 mV (-55°C to +200°C)
APPLICATIONS
•• PRECISION A/D and D/A CONVERTERS
•• ACCURATE COMPARATOR
THRESHOLD VOLTAGE
•• HIGH RESOLUTION SERVO SYSTEMS
•• HIGH TEMPERATURE TEST and
MEASUREMENT SYSTEMS
•• TRANSDUCER EXCITATION
•• GEOLOGICAL EQUIPMENT
DESCRIPTION
VRE125 series references are designed to operate over an extremely wide temperature range (-55°C to +200°C) and still provide excellent accuracy. The VRE125 provides a +5V output and the VRE127 provides a ±5V output. All types are available in commercial (C suffix) and military (M suffix) models. They are hermetically sealed and are screened for high reliability and quality. Two accuracy grades (standard and A) are available in both models. The adjacent selector guide shows the limits of the most important parameters of the VRE125/127 series references.
The accuracy of the VRE125/127 series over temperature is achieved by using Thaler
Corporation's patented multi-point compensation technique. The stability of the VRE125 series is enhanced by using a zener diode instead of a bandgap reference, which is typically used in 5V references. Zener diodes have better long term stability and don't suffer the significant shifts caused by temperature cycling that bandgap references do.
Type
VRE125C +5V ±0.9mV ±3.0mV ±0.8mV VRE125CA +5V ±0.6mV ±2.0mV ±0.4mV VRE125M +5V ±0.9mV ±3.0mV ±0.8mV VRE125MA +5V ±0.6mV ±2.0mV ±0.4mV
VRE127C ±5V ±0.9mV ±3.0mV ±0.8mV VRE127CA ±5V ±0.6mV ±2.0mV ±0.4mV VRE127M ±5V ±0.9mV ±3.0mV ±0.8mV VRE127MA ±5V ±0.6mV ±2.0mV ±0.4mV
SELECTION GUIDE
Max. Volt
Output
Deviation
(-55°C
to +150°C)
Max. Volt Deviation
(150°C
to +200°C)
Initial Error
(Max)
Other performance parameters, such as warm-up drift and long term stability are better than competitive models.
Superior stability, accuracy, and quality make these references ideal for high temperature applications such as A/D and D/A converter references.
VRE125DS REV. C SEPT 1994
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10K unless otherwise noted.
VRE125/127
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply ±13.5 ±22 * * * * * * V Operating Temperature -55 200 * * * * * * °C Storage Temperature -65 150 * * * * * * °C Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE125 +5 * * * V
VRE127 ±5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 0.8 0.4 0.8 0.4 mV Warmup Drift 2 1 2 1 ppm
-55°C to 150°C 0.9 0.6 * * mV
(1)
(3)
150°C to 200°C 3.0 2.0 * * mV
Long-Term Stability 6 * * * ppm/1000hr. Noise (.1-10Hz) 3 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 6 10 * * * * * * ppm/V Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 10 * * * mV Temperature Coefficient 4 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE125 +PS 4 7 * * * * * * mA
VRE127 +PS 6 9 * * * * * * mA
VRE127 -PS 4 6 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.
2.The specified values are unloaded.
3. Cone widening from 150 °C value to specified value.
VRE125DS REV. C SEPT 1994