THALER VRE116MA, VRE116M, VRE116CA, VRE116C, VRE115MA Datasheet

...
VRE114/115/116
Precision Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
VERY HIGH ACCURACY: 1.500 V OUTPUT ±150 µV
EXTREMELY LOW DRIFT: 0.8 ppm/°C 55°C to +125°C
LOW WARM-UP DRIFT: 1 ppm Typ.
EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
EXCELLENT LINE REGULATION: 3 ppm/V Typ.
MILITARY PROCESSING OPTION
APPLICATIONS
PRECISION A/D and D/A CONVERTERS
TRANSDUCER EXCITATION
ACCURATE COMPARATOR THRESHOLD
REFERENCE
HIGH RESOLUTION SERVO SYSTEMS
DIGITAL VOLTMETERS
HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
DESCRIPTION
VRE114 Series Precision Voltage References provide ultrastable +1.500V (VRE114), -1.500V (VRE115) and ±1.500V (VRE116) outputs with ±150 µV initial accuracy and temperature coefficient as low as 0.8 ppm/°C over the full military temperature range. This improvement in accuracy is made possible by a unique, proprietary multipoint laser compensation technique developed by Thaler Corporation. Significant improvements have been made in other performance parameters as well, including initial accuracy, warm-up drift, line regulation, and long-term stability, making the VRE114 series the most accurate and stable 1.5V reference available.
VRE114/115/116 devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
Type
VRE114C +1.5V -25°C to +85°C 150 µV VRE114CA +1.5V -25°C to +85°C 75 µV VRE114M +1.5V -55°C to +125°C 240 µV VRE114MA +1.5V -55°C to +125°C 120 µV
VRE115C -1.5V -25°C to +85°C 150 µV VRE115CA -1.5V -25°C to +85°C 75 µV VRE115M -1.5V -55°C to +125°C 240 µV VRE115MA -1.5V -55°C to +125°C 120 µV
VRE116C ±1.5V -25°C to +85°C 150 µV VRE116CA ±1.5V -25°C to +85°C 75 µV VRE116M ±1.5V -55°C to +125°C 240 µV VRE116MA ±1.5V -55°C to +125°C 120 µV
SELECTION GUIDE
Output
Temperature
Operating Range
Max. Volt Deviation
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.
VRE114DS REV. C NOV 2000
SPECIFICATIONS
ELECTRICAL
Vps =±15V, T = 25°C, RL = 10k? unless otherwise noted.
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply ±13.5 ±22 * * * * * * V Operating Temperature -25 85 * * -55 125 -55 125 °C Storage Temperature -65 150 * * * * * * °C Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE114 +1.5 * * * V VRE115 -1.5 * * * V VRE116 ±1.5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 300 150 300 150 µV Warmup Drift 2 1 2 1 ppm Tmin - Tmax 150 75 240 120 µV Long-Term Stability 6 * * * ppm/1000hr. Noise (.1-10Hz) 1.0 * * * µVpp
(1)
VRE114/115/116
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 3 10 * * * * * * ppm/V Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 5 * * * mV Temperature Coefficient 1 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE114 +PS/ -PS 5 7 * * * * * * mA VRE116 +PS 7 9 * * * * * * mA VRE115/116 -PS 4 6 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.
2.The specified values are unloaded.
VRE114DS REV. C NOV 2000