VRE105/107
Precision
Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
•• VERY HIGH ACCURACY: 5.000 V ±0.4 mV
•• EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C
•• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
•• EXCELLENT LINE REGULATION: 6 ppm/V Typ.
•• WIDE SUPPLY RANGE: ±13.5 V to ±22.0 V
•• HERMETIC 14-PIN CERAMIC DIP
•• MILITARY PROCESSING OPTION
DESCRIPTION
provide ultrastable +5.000 V (VRE105) and
±5.000 V (VRE107) outputs with ±0.4 mV initial
accuracy and temperature coefficient as low as
0.6 ppm/°C over the full military temperature
range. This impovement in accuracy is made
possible by a unique, proprietary multipoint laser
compensation technique developed by Thaler
Corporation. Significant improvements have been
made in other performance parameters as well,
including initial accuracy, warm-up drift, line
regulation, and long-term stability, making the
VRE105 series the most accurate and stable 5V
references available.
VRE105C +5V -25°C to +85°C 0.4mV
VRE105CA +5V -25°C to +85°C 0.2mV
VRE105M +5V -55°C to +125°C 0.6mV
VRE105MA +5V -55°C to +125°C 0.3mV
VRE107C ±5V -25°C to +85°C 0.4mV
VRE107CA ±5V -25°C to +85°C 0.2mV
VRE107M ±5V -55°C to +125°C 0.6mV
VRE107MA ±5V -55°C to +125°C 0.3mV
APPLICATIONS
•• PRECISION A/D and D/A CONVERTERS
•• TRANSDUCER EXCITATION
•• ACCURATE COMPARATOR THRESHOLD
REFERENCE
•• HIGH RESOLUTION SERVO SYSTEMS
•• DIGITAL VOLTMETERS
•• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
SELECTION GUIDEVRE105 Series Precision Voltage References
Type Output
Temperature
Operating Range
Max. Volt
Deviation
VRE105 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to
+125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for
maximum long-term stablity. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D
and D/A converters, high accuracy test and measurement instrumentation, and tranducer excitation.
VRE105DS REV. C SEPT 1994
4-32
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10KΩ unless otherwise noted.
VRE105/107
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply ±13.5 ±22 * * * * * * V
Operating Temperature -25 85 * * -55 125 -55 125 °C
Storage Temperature -65 150 * * * * * * °C
Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE105 +5 * * * V
VRE107 ±5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 800 400 800 400 µV
Warmup Drift 2 1 2 1 ppm
Tmin - Tmax 400 200 600 300 µV
(1)
Long-Term Stability 6 * * * ppm/1000hr.
Noise (.1-10Hz) 3 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 6 10 * * * * * * ppm/V
Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 10 * * * mV
Temperature Coefficient 4 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE105 +PS 5 7 * * * * * * mA
VRE107 +PS 7 9 * * * * * * mA
VRE107 -PS 4 6 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the
maximum deviation from the output voltage at 25°C
over the specified operating temperature range.
4-32
2.The specified values are unloaded.
VRE105DS REV. C SEPT 1994