THALER VRE104C, VRE104MA, VRE104M, VRE104CA Datasheet

VRE104
Precision Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
•• VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV
•• EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C
•• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
•• EXCELLENT LINE REGULATION: 6 ppm/V Typ.
•• WIDE SUPPLY RANGE: +13.5 to +22.0 V
•• MILITARY PROCESSING OPTIONS
DESCRIPTION
VRE104 Series Precision Voltage References provide ultrastable +4.500 V outputs with up to ±0.4 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range.
APPLICATIONS
•• PRECISION A/D and D/A CONVERTERS
•• TRANSDUCER EXCITATION
•• ACCURATE COMPARATOR THRESHOLD
REFERENCE
•• HIGH RESOLUTION SERVO SYSTEMS
•• DIGITAL VOLTMETERS
•• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
SELECTION GUIDE
Type Output
Temperature
Operating Range
Max. Volt Deviation
These references are specifically designed to be used with the Crystal Semiconductor line of successive-approximation type Analog to Digital Converters (ADCs). This line of ADCs sets new standards for temperature drift, which can only be as good as the external reference used. The Thaler VRE104 combined with a Crystal ADC will provide the lowest drift data conversion obtainable.
VRE104 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make the VRE104 ideal for all precision applications which may require a 4.5V reference. High-accuracy test and measurement instrumentation, and transducer excitation are some other applications which can benefit from the high accuracy of the VRE104.
VRE104C +4.5V -25°C to +85°C 0.4mV VRE104CA +4.5V -25°C to +85°C 0.2mV
VRE104M +4.5V -55°C to +125°C 0.6mV VRE104MA +4.5V -55°C to +125°C 0.3mV
VRE104DS REV. C SEPT 1994
ELECTRICAL SPECIFICATIONS
Vps =+15V, T = 25°C, RL = 10K
unless otherwise noted.
VRE104
MODEL C CA M MA
PARAMETERS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
ABSOLUTE MAXIMUM RATINGS
Power Supply +13.5 +22 * * * * * * V Operating Temperature -25 85 * * -55 125 -55 125 °C Storage Temperature -65 150 * * * * * * °C Short Circuit Protection Continuous * * *
OUTPUT VOLTAGE
VRE104 +4.5 * * * V
OUTPUT VOLTAGE ERRORS
Initial Error 800 400 800 400 µV Warmup Drift 2 1 2 1 ppm T
- T
min
max
(1)
400 200 600 300 µV Long-Term Stability 6 * * * ppm/1000hrs Noise (.1-10Hz) 3 * * * µVpp
OUTPUT CURRENT
Range ±10 * * * mA
REGULATION
Line 6 10 * * * * * * ppm/V Load 3 * * * ppm/mA
OUTPUT ADJUSTMENT
Range 10 * * * mV Temperature Coeff. 4 * * * µV/°C/mV
POWER SUPPLY CURRENTS
(2)
VRE104 +PS 5 7 * * * * * * mA
NOTES: *Same as C Models.
1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range.
2.The specified values are unloaded.
VRE104DS REV. C SEPT 1994
Loading...
+ 3 hidden pages