User Guide

Veritas 8/Veritas 8Compact/Veritas R8

INS036-5

User Guide Summary

 

User Guide Summary

 

Full Set

Enter Your Code

!!!!

 

Press Full

"

Part Set

Enter Your Code

!!!!

 

Press Part Set Number

#or $

 

Press Part

%

Unset

Enter Your Code

!!!!

Omit Zones

Enter Your Code

!!!!

 

Press Full or (Part Set No &) Part

"or !%

 

Press Omit

&

 

Press Zone Number(s)

!

 

Press Prog

'

Reset

Enter Your Code

!!!!

 

Press Reset

(

Chime Zones

Enter Your Code

!!!!

 

Press Chime

)

 

Press Zone Number(s)

!

 

Press Prog

'

Chime On/Off

Press Chime

)

Test Sounders &

Enter Your Code

!!!!

Strobe

Press Prog

'

 

Enter 05

*+

 

Press 3 (Internal Sounder)

,

 

Press 2 (Strobe)

$

 

Press 1 (Bell)

#

 

Press Reset

(

 

Press Reset

(

Walk Test

Enter Your Code

!!!!

 

Press Prog

'

 

Enter 06

*-

 

Conduct Walk Test

Conduct Walk Test

 

Press Reset

(

 

Press Reset

(

Change Code

Enter Existing Code

!!!!

 

Press Prog

'

 

Press 60

-*

 

Enter New Code

!!!!

 

Press Prog

'

 

Press Reset

(

2

INS036-5

User Guide

Setting the System

If any zones are left open (e.g. a door ajar) or are ‘in fault’ the display will illuminate the zone light of these zones and sound a repeating series of bleeps corresponding to the zone number (i.e. Zone 1 bleeps once, Zone 2 bleeps twice, etc.). If more than one zone is open the bleeps will correspond to the highest zone number (i.e. if Zone 2 and Zone 6 are open the control panel will bleep 6 times).

While one or more zones are open the exit timer is suspended. Open zones that will be closed during exit (e.g. exit zones, like the front door) may be disregarded. Other open zones should be closed. The exit tone and exit timer will resume when all zones are closed. If it is necessary to leave a zone open then it must be omitted (see “To OMIT Zones During Setting” below). If an open zone cannot be closed then it may be ‘in fault’. If the fault cannot be corrected contact your alarm company.

Your Installer can program the system so that it can be set using the "or %keys without the need to first enter a User code.

To FULL Set the System

Ensure all zones are closed (e.g. windows and doors). Enter your 4 digit code !!!!. The Unset light will flash. Press ". The exit tone will sound. Leave the premises. When the system has set the exit tone will stop.

To PART Set the System

Ensure all zones in the intended Part Set area are closed. Enter your 4 digit code !!!!. The Unset light will flash. Press the number of the required Part Set Suite #or $. Press %. The quiet exit tone will sound. Leave the protected area. When the system has set the exit tone will stop.

1.If Part Set Suite 1 is desired then it is NOT necessary to press # before pressing %.

2.After entering your code the Unset light will flash indicating the control panel is ready to accept a command (e.g. " or

%). If no valid command is entered the system will revert to unset after 16 seconds.

3.Excluded zones (whether from part set or manual omit) that are closed will flash during the exit period.

INS036-5

3