Texas Instruments SN74ALS841DW, SN74ALS841DWR, SN74ALS841NT Datasheet

SN74ALS841, SN74AS841A . . . DW OR NT PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7 8 9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
OE
1D 2D 3D 4D 5D 6D 7D 8D 9D
10D
V
CC
1Q 2Q 3Q 4Q 5Q 6Q 7Q 8Q 9Q 10Q LE
SN74ALS842 . . . DW OR NT PACKAGE
(TOP VIEW)
1 2 3 4 5 6 7 8 9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
OE
1D 2D 3D 4D 5D 6D 7D 8D 9D
10D
V
CC
1Q 2Q 3Q 4Q 5Q 6Q 7Q 8Q 9Q 10Q LE
SN74ALS841, SN74AS841A, SN74ALS842
10-BIT BUS-INTERFACE D-TYPE LATCHES
WITH 3-STATE OUTPUTS
SDAS059C – DECEMBER 1983 – REVISED JANUARY 1995
Copyright 1995, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3-State Buffer-Type Outputs Drive Bus
Lines Directly
Bus-Structured Pinout
Provide Extra Bus-Driving Latches
Necessary for Wider Address/Data Paths or Buses With Parity
Buffered Control Inputs to Reduce
dc Loading Effects
Power-Up High-Impedance State
Package Options Include Plastic
Small-Outline (DW) Packages and Standard Plastic (NT) 300-mil DIPs
description
These 10-bit latches feature 3-state outputs designed specifically for driving highly capacitive or relatively low-impedance loads. They are particularly suitable for implementing buffer registers, I/O ports, bidirectional bus drivers, and working registers.
The ten latches are transparent D-type latches. The SN74ALS841 and SN74AS841A have noninverting data (D) inputs. The SN74ALS842 has inverting D
inputs.
A buffered output-enable (OE
) input places the ten outputs in either a normal logic state (high or low logic levels) or a high-impedance state. In the high-impedance state, the outputs neither load nor drive the bus lines significantly. The high-impedance state and increased drive provide the capability to drive bus lines without interface or pullup components.
OE
does not affect the internal operation of the latches. Previously stored data can be retained or new data can
be entered while the outputs are off. The SN74ALS841, SN74AS841A, and SN74ALS842 are characterized for operation from 0°C to 70°C.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
SN74ALS841, SN74AS841A, SN74ALS842 10-BIT BUS-INTERFACE D-TYPE LATCHES WITH 3-STATE OUTPUTS
SDAS059C – DECEMBER 1983 – REVISED JANUARY 1995
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Function Tables
SN74ALS841, SN74AS841A
INPUTS
OUTPUT
OE LE D
Q
L H H H L HL L LLX Q
0
HXX Z
SN74ALS842
INPUTS
OUTPUT
OE LE D
Q
L H H L L HL H LLX Q
0
HXX Z
logic symbols
EN
1
7
6D
8
7D
9
8D
10
9D
1D
2
1D
6Q
18
7Q
17
8Q
16
9Q
15
1Q
23
3
2D
4
3D
5
4D
6
5D
2Q
22
3Q
21
4Q
20
5Q
19
OE
C1
13
LE
11
10D
10Q
14
SN74ALS841, SN74AS841A
EN
1
7 8 9 10
1D
2
6Q
18
7Q
17
8Q
16
9Q
15
1Q
23 3 4 5 6
2Q
22
3Q
21
4Q
20
5Q
19
OE
C1
13
LE
11
10Q
14
SN74ALS842
1D 2D 3D
4D 5D
6D 7D
8D 9D
10D
These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
SN74ALS841, SN74AS841A, SN74ALS842
10-BIT BUS-INTERFACE D-TYPE LATCHES
WITH 3-STATE OUTPUTS
SDAS059C – DECEMBER 1983 – REVISED JANUARY 1995
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic diagrams (positive logic)
1D
OE
2
1
13
1Q
23
LE
1D
To Nine Other Channels
C1
SN74ALS841, SN74AS841A
1D
OE
2
1
13
1Q
23
LE
1D
To Nine Other Channels
C1
SN74ALS842
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage applied to a disabled 3-state output 5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN74ALS841, SN74ALS842 0°C to 70°C. . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Loading...