现货库存、技术资料、百科信息、热点资讯,精彩尽在鼎好!
NE556, SA556, SE556
DUAL PRECISION TIMERS
SLFS023C – APRIL 1978 – REVISED DECEMBER 1999
D
Two Precision Timing Circuits per Package
D
Astable or Monostable Operation
D
TTL-Compatible Output Can Sink or Source
Up to 150 mA
D
Active Pullup or Pulldown
D
Designed to be Interchangeable With
Signetics NE556, SA556, and SE556
D
Applications Include:
– Precision Timers From Microseconds to
Hours
– Pulse-Shaping CIrcuits
– Missing-Pulse Detectors
– Tone-Burst Generators
– Pulse-Width Modulators
– Pulse-Position Modulators
– Sequential Timers
– Pulse Generators
– Frequency Dividers
– Application Timers
– Industrial Controls
– Touch-Tone Encoders
description
NE556, SA556 . . . D, OR N PACKAGE
SE556 ...J PACKAGE
(TOP VIEW)
1DISCH
1THRES
1CONT
1RESET
1OUT
1TRIG
GND
1
2
3
4
5
6
7
14
13
12
11
10
9
8
V
CC
2DISCH
2THRES
2CONT
2RESET
2OUT
2TRIG
These devices provide two independent timing circuits of the NE555, SA555, or SE555 type in each package.
These circuits can be operated in the astable or the monostable mode with external resistor-capacitor (RC)
timing control. The basic timing provided by the RC time constant can be controlled actively by modulating the
bias of the control-voltage input.
The threshold (THRES) and trigger (TRIG) levels are normally two-thirds and one-third, respectively , of V
CC
These levels can be altered by using the control-voltage (CONT) terminal. When the trigger input falls below
trigger level, the flip-flop is set and the output goes high. If the trigger input is above the trigger level and the
threshold input is above the threshold level, the flip-flop is reset and the output is low. The reset (RESET) input
can override all other inputs and can be used to initiate a new timing cycle. When the reset input goes low, the
flip-flop is reset and the output goes low. When the output is low, a low-impedance path is provided between
the discharge (DISCH) terminal and ground (GND).
The NE556 is characterized for operation from 0°C to 70°C. The SA556 is characterized for operation from
–40°C to 85°C, and the SE556 is characterized for operation over the full military range of –55°C to 125°C.
AVAILABLE OPTIONS
T
VCC = 15 V
0°C to 70°C 11.2 V NE556D – NE556N
–40°C to 85°C 11.2 V SA556D – SA556N
–55°C to 125°C 10.6 V – SE556J –
The D package is available taped and reeled. Add the suffix R to the device type (e.g., NE556DR).
PACKAGED DEVICES
.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Copyright 1999, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
1
NE556, SA556, SE556
DUAL PRECISION TIMERS
SLFS023C – APRIL 1978 – REVISED DECEMBER 1999
RESET
Low Irrelevant Irrelevant Low On
High < 1/3 V
High > 1/3 V
High > 1/3 V
†
Voltage levels shown are nominal.
functional block diagram, each timer
TRIGGER VOLTAGE†THRESHOLD VOLTAGE†OUTPUT DISCHARGE SWITCH
DD
DD
DD
FUNCTION TABLE
(each timer)
Irrelevant High Off
> 2/3 V
> 2/3 V
DD
DD
Low On
As previously established
CC
R
THRES
CONT
R
TRIG
R
GND
RESET can override TRIG, which can override THRES.
RESETV
R1
RS1
OUT
DISCH
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) 18 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage (CONT, RESET, THRES, and TRIG) V
Output current ±225 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θJA (see Note 2): D package 86°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J package 300°C. . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or N package 260°C. . . . . . . . . . . . . . . .
Storage temperature range, T
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network ground terminal.
2. The package thermal impedance is calculated in accordance with JESD 51.
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 80°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
‡
CC
DISSIPATION RATING TABLE
PACKAGE
J 1375 mW 11.0 mW/°C 880 mW 715 mW 275 mW
2
TA ≤ 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING