Texas Instruments 5962-88718012A Datasheet

SN54HC05, SN74HC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCLS080B – MARCH 1984 – REVISED MA Y 1997
D
description
These devices contain six independent inverters. They perform the Boolean function Y = A in positive logic. The open-drain outputs require pullup resistors to perform correctly . They may be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions.
The SN54HC05 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74HC05 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
(each inverter)
INPUT
A
H L
L H
OUTPUT
Y
SN54HC05 . . . J OR W PACKAGE SN74HC05 ...D OR N PACKAGE
SN54HC05 . . . FK PACKAGE
2A
NC
2Y
NC
3A
NC – No internal connection
(TOP VIEW)
1A
1
1Y
2
2A
3
2Y
4
3A
5 6
3Y
GND
7
(TOP VIEW)
1Y1ANC
3212019
4 5 6 7 8
910111213
3Y
GND
NC
14 13 12 11 10
9 8
V
4Y
CC
V 6A 6Y 5A 5Y 4A 4Y
6A
18 17 16 15 14
4A
CC
6Y NC 5A NC 5Y
logic symbol
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, N, and W packages.
1A 2A 3A 4A 5A 6A
1 3 5 9 11 13
1
logic diagram (positive logic)
AY
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
10 12
2
1Y
4
2Y
6
3Y
8
4Y 5Y
6Y
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright 1997, Texas Instruments Incorporated
1
SN54HC05, SN74HC05
UNIT
PARAMETER
TEST CONDITIONS
V
UNIT
HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCLS080B – MARCH 1984 – REVISED MA Y 1997
absolute maximum ratings over operating free-air temperature range
Supply voltage range, V
–0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, IO (VO = 0 to VCC) ±25 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through VCC or GND ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
(see Note 2): D package 127°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JA
N package 78°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
recommended operating conditions
SN54HC05 SN74HC05
MIN NOM MAX MIN NOM MAX
V
V
V
V V
t
t
T
Supply voltage 2 5 6 2 5 6 V
CC
VCC = 2 V 1.5 1.5
High-level input voltage
IH
Low-level input voltage
IL
Input voltage 0 V
I
Output voltage 0 V
O
Input transition (rise and fall) time
Operating free-air temperature –55 125 –40 85 °C
A
VCC = 4.5 V VCC = 6 V 4.2 4.2 VCC = 2 V 0 0.5 0 0.5 VCC = 4.5 V VCC = 6 V 0 1.8 0 1.8
VCC = 2 V 0 1000 0 1000 VCC = 4.5 V VCC = 6 V 0 400 0 400
3.15 3.15
0 1.35 0 1.35
CC CC
0 500 0 500
0 V 0 V
CC CC
V
V
V V
ns
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
2
I
OH
V
I
I
I
CC
C
OL
i
CC
VI = VIH or VIL, VO = V
VI = VIH or V
VI = VCC or 0 6 V ±0.1 ±100 ±1000 ±1000 nA VI = VCC or 0, IO = 0 6 V 2 40 20 µA
IL
CC
IOL = 20 µA
IOL = 4 mA 4.5 V 0.17 0.26 0.4 0.33 IOL = 5.2 mA 6 V 0.15 0.26 0.4 0.33
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
6 V 0.01 0.5 10 5 µA 2 V 0.002 0.1 0.1 0.1
4.5 V 0.001 0.1 0.1 0.1 6 V 0.001 0.1 0.1 0.1
2 V to 6 V 3 10 10 10 pF
TA = 25°C SN54HC05 SN74HC05
MIN TYP MAX MIN MAX MIN MAX
V
Loading...