Texas Instruments 5962-8760901CA Datasheet

SN54AC04, SN74AC04
HEX INVERTERS
SCAS519C – JULY 1995 – REVISED SEPTEMBER 1996
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
EPIC
(Enhanced-Performance Implanted
CMOS) 1-µm Process
D
Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), and Thin Shrink Small-Outline (PW) Packages, Ceramic Chip Carriers (FK) and Flatpacks (W), and Standard Plastic (N) and Ceramic (J) DIPS
description
The ‘AC04 contain six independent inverters. The devices perform the Boolean function Y = A.
The SN54AC04 is characterized for operation over the full military temperature range of –55°C to 125°C. The SN74AC04 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE (each inverter)
INPUT
OUTPUT
A Y
H L L H
logic symbol
1
1A
1Y
2
3
2A 2Y
4
5
3A 3Y
6
9
4A 4Y
8
11
5A 5Y
10
13
6A 6Y
12
1
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, DB, J, N, PW, and W packages.
logic diagram, each inverter (positive logic)
YA
SN54AC04 ...FK PACKAGE
(TOP VIEW)
3212019
910111213
4 5 6 7 8
18 17 16 15 14
6Y NC 5A NC 5Y
2A
NC
2Y
NC
3A
1Y1ANC
4Y
4A
V
6A
3Y
GND
NC
CC
NC – No internal connection
1 2 3 4 5 6 7
14 13 12 11 10
9 8
1A 1Y 2A 2Y 3A 3Y
GND
V
CC
6A 6Y 5A 5Y 4A 4Y
SN54AC04 ...J OR W PACKAGE
SN74AC04 . . . D, DB, N, OR PW PACKAGE
(TOP VIEW)
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Copyright 1996, Texas Instruments Incorporated
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
SN54AC04, SN74AC04 HEX INVERTERS
SCAS519C – JULY 1995 – REVISED SEPTEMBER 1996
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1) –0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
(see Note 1) –0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, IIK (V
I
< 0 or V
I
> VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (V
O
< 0 or V
O
> VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CC
or GND ±200 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum power dissipation at T
A
= 55°C (in still air) (see Note 2): D package 1.25 W. . . . . . . . . . . . . . . . . . .
DB package 0.5 W. . . . . . . . . . . . . . . . . .
N package 1.1 W. . . . . . . . . . . . . . . . . . . .
PW package 0.5 W. . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils, except for the N package, which has a trace length of zero.
recommended operating conditions (see Note 3)
SN54AC04 SN74AC04
MIN MAX MIN MAX
UNIT
V
CC
Supply voltage 2 6 2 6 V
VCC = 3 V 2.1 2.1
V
IH
High-level input voltage
VCC = 4.5 V
3.15 3.15
V VCC = 5.5 V 3.85 3.85 VCC = 3 V 0.9 0.9
V
IL
Low-level input voltage
VCC = 4.5 V
1.35 1.35
V VCC = 5.5 V 1.65 1.65
V
I
Input voltage 0 V
CC
0 V
CC
V
V
O
Output voltage 0 V
CC
0 V
CC
V VCC = 3 V –12 –12
I
OH
High-level output current
VCC = 4.5 V
–24 –24
mA VCC = 5.5 V –24 –24 VCC = 3 V 12 12
I
OL
Low-level output current
VCC = 4.5 V
24 24
mA VCC = 5.5 V 24 24
t/∆v Input transition rise or fall rate 0 8 0 8 ns/V T
A
Operating free-air temperature –55 125 –40 85 °C
NOTE 3: Unused inputs must be held high or low to prevent them from floating.