Tenma 72-2605, 72-2610, 72-10410, 72-10405, 72-10415 User Manual

1
Model: 72-2605, 72-2610
72-10405 and 72-10410 and 72-10415
Digital Multimeter
2
Please read these instructions carefully before use and retain for future reference.
Check the test leads, probes and case insulation before using. If you nd any
breakage or abnormality, or you consider the device is broken, stop using the device immediately.
When using the test probes, keep your ngers behind the nger protection ring.
Do not use the meter with the back cover open.
Select appropriate test range for measurements.
Ensure all inputs are less than the range selected otherwise it may cause electrical shock or meter damage.
Do not change the range selector position during voltage or current measurements.
Do not apply a voltage over 1000V between COM terminal and ground.
Take caution when working voltages are above 60V DC or 30V AC rms.
Do not connect the meter to voltage signals when the range selector is on current, resistance, diode or continuity range.
When measuring current, each single measurement should be shorter than 10 seconds. For current values over 5A, the wait period between each measurement must be longer than 15 minutes.
When a measurement has been completed, disconnect the testing probes from the circuit under test.
Replace the batteries as soon as the low battery indicator appears on the display.
Remove dead batteries from the meter or if it is not going to be used for a long time.
Never mix old and new batteries together, or different types of batteries.
Never dispose of batteries in a re, or attempt to recharge ordinary batteries.
Before replacing the battery, turn off the meter and disconnect all the test probes.
To prolong battery life turn off the meter after use.
CAT III: Measurement category III is for measurements performed in the building installation. Examples are measurements on distribution boards, circuit-breakers, and wiring, such as cables, bus-bars, junction boxes, switches and socket-outlets
in the xed installation, and equipment for industrial application and some other equipment such as stationary motors with permanent connection to the xed
installation.
Only use test leads and probes that are in compliance with IEC 61010-031, and rated CAT III 1000V.
SYMBOL GUIDE
Low battery Grounding Warning
Continuity Buzzer AC DC
Fuse Double insulated Diode
IMPORTANT SAFETY INFORMATION
3
WHAT’S INCLUDED
Digital multimeter
User manual
Set of test leads
K-type temperature probe (72-10405 & 72-2610 only)
9V battery (installed)
RS232 PC interface cable
FUNCTIONS
1. LCD Display
2. FUNCTION buttons
3. BLUE button
4. Range selector
5. Input terminals
DC VOLTAGE
Range Resolution 72-2605 Accuracy 72-10405
Input
Impedance
Fixed value
input
40mV 0.01mV ±(0.8%+3)
Around
>3000MΩ
1000V DC
750V AC
400mV 0.1mV ±(0.8%+3)
4V 0.001V
±(0.5%+1)
Around 10MΩ
40V 0.01V
400V 0.1V
1000V 1V ±(1.0%+3)
Range Resolution 72-2610 Accuracy 72-10410
Input
Impedance
Fixed value
input
60mV 0.01mV ±(0.8%+3)
Around
>3000MΩ
1000V DC
750V AC
600mV 0.1mV ±(0.8%+3)
6V 0.001V
±(0.5%+1)
Around 10MΩ
60V 0.01V
600V 0.1V
1000V 1V ±(1.0%+3)
1
2
3
4
5
72-2605 AND 72-10405
72-2610 AND 72-10410
4
AC VOLTAGE
Range Resolution 72-2610 Accuracy
Input
Impedance
Fixed value
input
220mV 0.01mV ±(0.1%+5)
Around
>3000MΩ
1000V DC
750V AC
2.2V 0.0001V
±(0.1%+2)
Around 10MΩ
22V 0.001V
220V 0.01V
1000V 0.1V ±(0.1%+5)
Range Resolution
Accuracy
45~1kHz >1kHz~10kHz
Input
Impedance
Fixed value
input
220mV 0.01mV ±(1.0%+10) ±(1.5%+50)
Around
>3000MΩ
1000V DC
750V AC
2.2V 0.0001V
±(0.8%+10)
±(1.2%+50)
Around 10MΩ
22V 0.001V
220V 0.01V ±(2.0%+50)
750V 0.1V ±(1.2%+10) ±(3.0%+10)
72-10415
72-10415
72-2605 and 72-10405
Range Resolution 72-2605 Accuracy 72-10405
Input
Impedance
Fixed value
input
40mV 0.01mV ±(1.2%+5)
Around
>3000MΩ
1000V DC
750V AC
400mV 0.1mV ±(1.2%+5)
4V 0.001V
±(1.0%+3)
Around 10MΩ
40V 0.01V
400V 0.1V
750V 1V ±(1.2%+5)
Range Resolution 72-2610 Accuracy 45~1kHz
Input
Impedance
Fixed value
input
60mV 0.01mV
±(1.2%+5)
Around
>3000MΩ
1000V DC
750V AC
600mV 0.1mV
6V 0.001V
±(1.0%+3)
Around 10MΩ
60V 0.01V
600V 0.1V
750V 1V ±(1.2%+5)
72-2610 and 72-10410
Displays effective value of sine wave. mV range is applicable from 5% of range to 100% of range.
Displays effective value of sine wave. mV range is applicable from 5% of range to 100% of range.
True RMS is applicable from 10% of range to 100% of range.
AC crest factor can be up to 3.0 except 1000V when it is 1.5.
A residual reading of 10 digits with test leads shorted will not affect stated.
5
DC CURRENT
Range Resoluon Accuracy Overload Protecon
400μA 0.1μA
±(1.0%+2)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
4000μA 1μA
40mA 0.01mA
±(1.2%+3)
400mA 0.1mA
4A 0.001A
±(1.5%+3)
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
10A 0.01A
Range Resoluon Accuracy Overload Protecon
600μA 0.1μA
±(1.0%+3)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
6000μA 1μA
60mA 0.01mA
600mA 0.1mA
6A 0.001A
±(1.2%+5)
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
10A 0.01A
Range Resoluon Accuracy Overload Protecon
220μA 0.01μA
±(0.5%+10)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
2200μA 0.1μA
22mA 0.001mA
220mA 0.01mA
10A 0.001A ±(1.2%+50)
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
72-2605 and 72-10405
72-2610 and 72-10410
72-10415
When <5A continuous measurement is allowed/
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
When <5A continuous measurement is allowed/
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
When <5A continuous measurement is allowed/
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
6
AC CURRENT
Range Resoluon Accuracy
Overload Protecon
400μA 0.1μA
±(1.2%+5)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
4000μA 1μA
40mA 0.01mA
±(1.5%+5)
400mA 0.1mA
4A 0.001A
±(2.0%+5)
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
10A 0.01A
Range Resoluon Accuracy
Overload Protecon
600μA 0.1μA
±(1.2%+5)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
6000μA 1μA
60mA 0.01mA
±(1.5%+5)
600mA 0.1mA
6A 0.001A
±(2.0%+5)
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
10A 0.01A
Range Resoluon
Accuracy
Overload Protecon
45~1kHz >1kHz~10kHz
220μA 0.01μA
±(0.8%+10) ±(1.2%+50)
Fuse 1 F600mA H 1000V
6.35 dia x 31.8mm
2200μA 0.1μA
22mA 0.001mA
±(1.2%+10) ±(1.5%+50)
220mA 0.01mA
10A 0.001A ±(1.5%+10)
>1kHz~5kHz
Fuse 2 F10A H 1000V
10.3 dia x 38.1mm
(2.0%+50)
72-2605 and 72-10405
72-2610 and 72-10410
72-10415
When <5A continuous measurement is allowed.
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
True RMS is applicable from 10% of range to 100% of range.
AC crest factor can be up to 3.0 except 1000V where it is 1.5.
A residual reading of 10 digits with test leads shorted will not effect stated.
When <5A continuous measurement is allowed.
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
Displays effective value of sine wave.
When <5A continuous measurement is allowed.
When >5A use 10 seconds measurement at an interval of more than 15 minutes.
Displays effective value of sine wave.