21-19700
DESOLDERING STATION
INSTRUCTION MANUAL
Thank you for purchasing 21-19700 Desoldering Station.
Please read the manual before using the unit.
Keep manual in accessible place for future reference.
www.Tenma.com
CAUTION
Please remember to remove the pump securing screw
(M4×10 marked red) from the bottom of the station before
using. Failure to do so may cause damage to the unit.
DESOLDERING GUN MAINTENANCE
TABLE OF CONTENTS
Package Contents ……..…………...………………….. 4
Care and Safety Precaution …………………..….. 5
Specifications …….…………..…..………………...….. 6
Features ………...………………………...……...…..... 6
Parts Guide ……….……………..…………………...….. 7
Operation Guidelines …..……………..…………..… 8-9
Maintenance …..……………...………………….….. 10
After extracting the Filter
Barrel Assembly we can
now take out the filter
spring or the filter pads for
cleaning or replacement.
Re-assemble Filter Barrel
assembly and place back to
the de-soldering gun body.
Push the Filter dock back in
place a “click” sound would
signify that the filter dock is
properly secured.
Using the Cleaning pin:
Caution: Desoldering gun will be hot during maintenance please
use proper materials and equipments to avoid injuries.
1. When the suction efficiency has deteriorated the
desoldering gun might be clogged. Follow these directions
to properly clean the desoldering gun.
2. Turn on the desoldering gun and wait for the nozzle to
heat up.
3. Slowly insert the cleaning pin while turning the cleaning
pin clockwise.
4. Pull the cleaning pin out in a straight motion.
2
11