Tenma 21-19700 User Manual

21-19700
DESOLDERING STATION
INSTRUCTION MANUAL
Thank you for purchasing 21-19700 Desoldering Station.
Please read the manual before using the unit.
www.Tenma.com
CAUTION
Please remember to remove the pump securing screw (M4×10 marked red) from the bottom of the station before using. Failure to do so may cause damage to the unit.
DESOLDERING GUN MAINTENANCE
TABLE OF CONTENTS
Package Contents ……..…………...………………….. 4
Care and Safety Precaution …………………..….. 5
Specifications …….…………..…..………………...….. 6
Features ………...………………………...……...…..... 6
Parts Guide ……….……………..…………………...….. 7
Operation Guidelines …..……………..…………..… 8-9
Maintenance …..……………...………………….….. 10
After extracting the Filter Barrel Assembly we can now take out the filter spring or the filter pads for cleaning or replacement.
Re-assemble Filter Barrel assembly and place back to the de-soldering gun body.
Push the Filter dock back in place a “click” sound would signify that the filter dock is properly secured.
Using the Cleaning pin:
Caution: Desoldering gun will be hot during maintenance please use proper materials and equipments to avoid injuries.
1. When the suction efficiency has deteriorated the desoldering gun might be clogged. Follow these directions to properly clean the desoldering gun.
2. Turn on the desoldering gun and wait for the nozzle to heat up.
3. Slowly insert the cleaning pin while turning the cleaning pin clockwise.
4. Pull the cleaning pin out in a straight motion.
2