Telefunken TSOP1130, TSOP1156, TSOP1138, TSOP1140, TSOP1137 Datasheet

...
TSOP11..
Vishay Telefunken
Photo Modules for PCM Remote Control Systems
Available types for different carrier frequencies
Type fo Type fo TSOP1130 30 kHz TSOP1133 33 kHz TSOP1136 36 kHz TSOP1137 36.7 kHz TSOP1138 38 kHz TSOP1140 40 kHz TSOP1156 56 kHz
Description
The TSOP11.. – series are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter. The demodulated output signal can directly be decoded by a microprocessor. The main benefit is the operation with short burst transmission codes (e.g. RECS 80) and high data rates.
GND
V
S
OUT
94 8691
Features
D
Photo detector and preamplifier in one package
D
Internal filter for PCM frequency
D
Improved shielding against electrical field disturbance
D
TTL and CMOS compatibility
D
Output active low
D
Low power consumption
D
High immunity against ambient light
Block Diagram
Input
PIN
AGC
Special Features
D
Enhanced data rate of 3500 bit/s
D
Operation with short bursts possible (6 cycles/burst)
Control
Circuit
Band Pass
Demodu-
lator
80 k
2
V
S
3
OUT
1
GND
Document Number 82006
94 8136
www.vishay.com
1 (8)Rev. 8, 29-Mar-01
TSOP11..
y()
()
()
Vishay Telefunken
Absolute Maximum Ratings
T
= 25_C
amb
Parameter Test Conditions Symbol Value Unit Supply Voltage (Pin 2) V Supply Current (Pin 2) I Output Voltage (Pin 3) V Output Current (Pin 3) I Junction Temperature T Storage Temperature Range T Operating Temperature Range T Power Consumption (T Soldering Temperature t x 10 s, 1 mm from case T
Basic Characteristics
T
= 25_C
amb
Parameter Test Conditions Symbol Min Typ Max Unit
Supply Current (Pin 2) VS = 5 V, Ev = 0 I
VS = 5 V, Ev = 40 klx, sunlight I Supply Voltage (Pin 2) V Transmission Distance Ev = 0, test signal see fig.8,
IR diode TSAL6200, I Output Voltage Low (Pin 3) I
Irradiance (30 – 40 kHz) Test signal see fig.7 E
Irradiance (56 kHz) Test signal see fig.7 E
Irradiance Test signal see fig.7 E Directivity Angle of half transmission distance ϕ
= 0.5 mA,Ee = 0.7 mW/m2,
OSL
f = fo, test signal see fig.7
Test signal see fig.8 E
Test signal see fig.8 E
x 85 °C) P
amb
= 0.4 A
F
SD SH
S
d 35 m
V
OSL
e min e min e min e min
e max
1/2
S
S
O
O
j
stg
amb
tot sd
–0.3...6.0 V
5 mA
–0.3...6.0 V
5 mA
100 –25...+85 –25...+85
50 mW
260
0.4 0.6 1.5 mA 1 mA
4.5 5.5 V
0.4 0.6 mW/m
0.35 0.5 mW/m
0.45 0.7 mW/m
0.40 0.6 mW/m
30 W/m
±45 deg
°
C
°
C
°
C
°
C
250 mV
2 2 2 2
2
Application Circuit
100 W *)
2
3
4.7 mF *) >10 k
W
optional
m
C
TSOP11..
TSAL62..
**)
12755
1
*) recommended to suppress power supply disturbances **) The output voltage should not be hold continuously at a voltage below 3.3V by the external circuit.
www.vishay.com
2 (8)
+5V
GND
Document Number 82006
Rev. 8, 29-Mar-01
Suitable Data Format
The circuit of the TSOP11... is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances. The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.
The data signal should fullfill the following condition:
TSOP11..
Vishay Telefunken
Some examples for suitable data format are: NEC Code, T oshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, RCMM Code, R–2000 Code, RECS–80 Code.
When a disturbance signal is applied to the TSOP1 1... it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.
Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).
Burst length should be 6 cycles/burst or longer.
After each burst which is between 6 cycles and 70
cycles a gap time of at least 10 cycles is neccessary.
For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should have at least same length as the burst.
Up to 2200 short bursts per second can be received continuously .
0 5 10 15 20
Some examples for such disturbance signals which are suppressed by the TSOP11... are:
DC light (e.g. from tungsten bulb or sunlight)
Continuous signal at 38kHz or at any other
frequency
Signals from fluorescent lamps with electronic ballast (an example of the signal modulation is in the figure below).
Document Number 82006
time [ms]
IR Signal from Fluorescent Lamp with low Modulation
www.vishay.com
3 (8)Rev. 8, 29-Mar-01