Operator's Manual
HVD3102 and HVD3106
High Voltage
Differential Probes
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106
High-Voltage Differential Probes
Operator's Manual
June 2014
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106 High-Voltage Differential Probes Operator's Manual
© 2014 Teledyne LeCroy, Inc. All rights reserved.
Unauthorized duplication of Teledyne LeCroy documentation materials other than for internal
sales and distribution purposes is strictly prohibited. However, clients are encouraged to
distribute and duplicate Teledyne LeCroy documentation for their own internal educational
purposes.
Teledyne LeCroy is a trademark of Teledyne LeCroy, Inc. Other product or brand names are
trademarks or requested trademarks of their respective holders. Information in this publication
supersedes all earlier versions. Specifications are subject to change without notice.
923278-00
June 2014
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
Operator's Manual
Contents
Safety 1
Symbols 1
Precautions 1
Introduction 3
Requirements 4
Probe Kit 5
Standard Accessories 6
Voltage Derating for Standard Accessories 8
Specifications 9
Guaranteed Specifications 9
Environmental Characteristics 9
Common Mode Rejection Ratio 12
Input Voltage vs. Frequency and Burn Limit 13
Differential Mode and Common Mode 14
Differential Mode Range and Common Mode Range 14
Differential Input Impedance 14
Operation 15
Connecting to the Test Instrument 15
Connecting to the Test Circuit 15
Operating with an Oscilloscope 16
Maintenance 19
Cleaning 19
Calibration Interval 19
Service Strategy 19
Replacement Parts 19
Returning a Product for Service 20
Functional Test Procedure 21
Required Equipment 21
Test Procedure 21
Performance Verification 22
Required Equipment 22
Preliminary Procedure 23
Certification Procedure 23
923278-00
i
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106 High-Voltage Differential Probes
HVD3102/HVD3106 Test Record 25
Reference 26
Certifications 26
Warranty 29
Contact Us 30
Notes 31
ii
923278-00
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
Operator's Manual
Safety
Follow these instructions to keep the probe operating in a correct and safe condition. Observe
generally accepted safety procedures in addition to the precautions specified in this section. The
overall safety of any system incorporating this product is the responsibility of the
assembler of the system.
Symbols
These symbols appear on the probe or in documentation to alert you to important safety
considerations.
CAUTION of damage to instrument, or WARNING of hazard to health. Attend to the
accompanying information to protect against personal injury or damage. Do not
proceed until conditions are fully understood and met.
HIGH VOLTAGE WARNING. Risk of electric shock.
ESD CAUTION. Risk of electrostatic discharge (ESD) that can damage the instrument if
anti-static measures are not taken.
Double Insulation
Measurement Ground
Precautions
Avoid personal injury or damage to your equipment by complying with the following safety
precautions:
Use only as specified. The probe is intended to be used only with compatible Teledyne LeCroy
instruments. Use of the probe and/or the equipment it is connected to in a manner other than
specified may impair the protection mechanisms.
Do not overload; observe all ratings. To avoid electric shock or fire, do not apply any potential
that exceeds the maximum rating of the probe and/or the probe accessory, whichever is less.
Observe all terminal ratings.
923278-00
1
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106 High-Voltage Differential Probes
Connect and disconnect properly. Always make the connections from the probe input leads to
the probe accessory that you intend to use before making any connections to a voltage source.
Do not connect accessories to (or disconnect from) a voltage source unless they are first
connected to the probe input leads. Avoid damaging cables through excessive bending.
Use only accessories compatible with the probe. Use only accessories that are rated for the
application. Substituting other accessories (except those specified in this manual) may create a
shock or burn hazard. Ensure the connections between probe input leads and probe
accessories are secure before connecting them to a voltage source.
Comply with the voltage derating curve. When measuring higher frequency signals, comply
with the Voltage vs. Frequency Derating Curve.
Use only within the operational environment listed. Do not use in wet or explosive
atmospheres.
Do not remove the probe's casing. Touching exposed connections may result in electric
shock.
Keep product surfaces clean and dry.
Handle with care. Probe accessory tips are sharp. They can puncture skin or cause other bodily
injury if not handled properly.
Keep fingers behind the finger guard of the probe accessories.
Do not operate with suspected failures. Before each use, inspect the probe and accessories
for any damage such as tears or other defects in the probe body, cable jacket, accessories, etc.
If any part is damaged, cease operation immediately and sequester the probe from inadvertent
use.
2
923278-00
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
Operator's Manual
Introduction
The HVD3102 and 3106 high-voltage active differential probes are safe, easy-to-use, and ideally
suited for power electronics measurements. The probes feature:
l Differential voltage measurement capability in high common-mode (up to 1000Vrms)
environments.
l Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
l Wide differential voltage range – 1500Vpeak rated and 2000Vpeak before amplifier
saturation to permit capture of short duration overshoots
l High offset capability at both 50x and 500x attenuation settings provides maximum
flexibility for capturing gate drive and control signals floating on a 1000Vdc bus
l 1% DC and low frequency gain accuracy
l ProBus interface with automatic scaling
l Auto Zero capabilities
The HVD3102 probe (25 MHz, 1000Vrms) and HVD3106 probe (120 MHz, 1000Vrms) are ideal
for power electronics applications, where the reference potential is elevated from ground. Each
probe is supplied with a complete set of lead accessories and a soft accessory case. The main
differences between the two probes is the probe bandwidth (25 MHz vs. 120 MHz).
The CMRR for the probes is exceptional out to very high frequencies. This greatly assists in
measurement of signals in the noisy, high common-mode environments common to power
electronics. The high CMRR combined with low probe noise and high offset capability makes the
probes capable of measuring very small control signals floating on high common-mode
voltages.
Probe specifications are provided for using the probe within a 1500Vpeak differential voltage
range. However, the probe can be safely operated above this range. Up to 2000Vpeak, the probe
will display the signal, but the probe specifications cannot be guaranteed. However, in this
range, the probe is operating below the saturation point of the amplifier, and very reasonable
results can be expected. The V/div range for each probe can be set up to 400V/div (3200Vp-p
displayed over all 8 vertical oscilloscope grid divisions).
923278-00
3
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106 High-Voltage Differential Probes
The probe is calibrated for high precision measurements to within 1% at DC to low frequency
(~10 kHz). This provides for high accuracy of top and base voltage levels of pulse-width
modulated signals. The AutoZero capability permits further measurement precision by allowing
small offset drifts to be calibrated out of the measurement.
With the ProBus interface, the HVD310x becomes an integral part of the oscilloscope. Power is
provided to the probe through the ProBus interface, so there is no need for a separate power
supply or batteries. Attenuation (50x or 500x) is automatically selected based on oscilloscope
gain range (V/div) setting and the offset adjust is unified with that of the oscilloscope. The
sensitivity of the HVD31xx ranges from 100 mV/Div to 400 V/Div, with the maximum available
offset dependent on the V/div setting and the oscilloscope model. In general, Teledyne LeCroy
12-bit High Resolution Oscilloscopes (HRO) and HD4096 High Definition Oscilloscopes (HDO)
provide the most offset capability over the widest range of V/div settings.
Requirements
The HVD3102 and HVD3106 probes are compatible with any Teledyne LeCroy oscilloscope
equipped with the ProBus interface and XStream software version 7.4 or greater.
4
923278-00
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
Operator's Manual
Probe Kit
The HVD3102 and HVD3106 probes are delivered in a soft accessory case (SAC-01A) with an
Operator's Manual, Certificate of Calibration, and all standard accessories described below.
HVD3102 and HVD3106 Probe Kit
See Replacement Parts for information about ordering replacement accessories.
Adobe portable document format (PDF) copies of this manual are available for free download
from teledynelecroy.com/support/techlib.
923278-00
5
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com
HVD3102 and HVD3106 High-Voltage Differential Probes
Standard Accessories
All accessories feature a 4 mm Banana (female) connector to accept most Banana plugs.
Spade Terminals, PK-HVA-05, QTY 2 (1 ea. red/black). Designed to connect to
terminal strips, posts and screws, the overall length is 63 mm (2.48 inches).
Insulated, 1000 V, CAT III.
WARNING. To avoid injury or death due to electric shock, do not
handle probe input leads connected to the Spade Terminals while
they are connected to a voltage source. Do not use Spade
Terminals as hand-held accessories; they are meant to be used as
a permanent installation in a test set up.
Safety Alligator Clips, PK-HVA-01, QTY 2 (1 ea. red/black). Designed to
reliably grip large components, such as bus bars and large bolts, the overall
length is 92.8 mm (3.65 inches) and the jaw opens to 32 mm (1.26 inch).
Only the lower jaw is conducive; the top jaw is insulating plastic. Insulated,
1000 V, CAT III.
Plunger Hook Clips, PK-HVA-03, QTY 2 (1 ea. red/black). Designed with a flexible stem to
access deep targets in dense environments and a 4.5 mm (0.177 inch) hook to attach to wire
leaded parts. The overall length is 157.6 mm (6.20 inches). Insulated, 1000 V, CAT II.
6
923278-00
www.GlobalTestSupply.com
Quality Teledyne Lecroy Products Online at: sales@GlobalTestSupply.com