The electronic control and display components of the TED 191 Portable Oxygen
Monitor are warranted against defective workmanship and materials for 24
months from date of shipment from Teledyne.
The class T-7 Micro-Fuel Cell is warranted for one year from the date of shipment
from Teledyne.
The liability of Teledyne, if any, shall be limited solely to the replacement and
repair of the goods, and shall not include shipping costs or other incidental
damages as defined in Section 2-715 of the U.S Uniform Commercial Code.
This warranty is null and void if any goods are subjected to misuse, negligence,
accident or repairs other than those performed by Teledyne or an authorized
service center.
Caution: Federal Law restricts this device to sale by or on the order of a
physician.
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
2
ABLE OF CONTENTS
T
ECTION TOPIC
S
I
NTRODUCTION
A
PPLICATIONS
D
ESCRIPTIONS OF FUNCTIONAL ZONES
F
RONT PANEL
R
EAR PANEL
1.
OPERATIONS
1.1SET-
1.2 I
1.3 I
1.4 C
1.5 N
1.6 S
2.A
3.C
4.D
5.R
NSTALL THE BATTERIES
NSTALL THE SENSOR
ALIBRATE THE INSTRUMENT
ORMAL OPERATION
ET THE ALARMS
NAESTHETIC AGENTS
LEANING
O’S AND DON’T’S
OUTINE MAINTENANCE
AGE NUMBER
P
:
:
UP
.17
4
5
6
7
8
9
10
11
12
13
14
15
16
6.T
7.T
8. E
9.E
10.E
11.D
12.R
S
T
G
S
ROUBLESHOOTING
ECHNICAL SPECIFICATIONS
FFECT OF PRESSURE
FFECT OF HUMIDITY
FFECT OF TEMPERATURE
ISCREPANCY IN READING
EPAIR SERVICE
ENSOR CELL REPLACEMENT LOG
ECHNICAL SERVICE LOG
ENERAL NOTES
PARE PARTS LIST
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
18
20
22
23
24
25
26
27
28
29
30
3
NTRODUCTION
I
The TED 191 Portable Oxygen Monitor is an easy-to-use, portable instrument that provides fast
and accurate oxygen monitoring and audio-visual alarm capability. The TED 191 is designed to
monitor concentrations of up to 100% oxygen in medical gas mixtures.
The TED 191 Portable Oxygen Monitor is designed and manufactured in accordance with strict
performance and quality protocols and subject to ISO 9002 Quality System protocols. When used
correctly, this instrument will provide you with many years of trouble free service.
The TED 191 Portable Oxygen Monitor is a compact, self-contained unit, which is battery powered
by four (4) dry cell batteries (size AA/penlight).
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
4
PPLICATIONS
A
The instrument is designed for the measurement of oxygen concentrations in a variety of medical
gas mixtures. It is recommended that the instrument be used only as a secondary measuringdevice to verify the concentration of oxygen in gas mixtures prepared using a gas blender or
similar apparatus. The use of this monitor as a primary or only means of preparing gas mixtures is
not advised.
The monitor is capable of verifying oxygen concentrations in gas mixtures used in:
• Anesthesia
• Neonatal Intensive care
• Adult Intensive care
• Respiratory / Oxygen Therapy
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
5
RONT PANEL
F
ESCRIPTION OF FUNCTIONAL ZONES
D
Alarm Mute ButtonHigh Alarm Setting Knob
60
50
60
102
102
70
70
90
90
80
80
HI
LO
TELEDYNE
X
21
% OXYGEN
OXYGEN MONITOR
Liquid Crystal Display (LCD)On / Off Switch
signal for ± 60 seconds. During this time, a red signal lamp will
flash, indicating a “muted” alarm condition is in force.
40
30
21
50
40
30
21
Low Alarm Setting Knob
On / Off SwitchAllows the operator to turn the instrument on and off.
Alarm Mute SwitchAllows the operator to “mute” the sound of the audible alarm
Calibration Control
I O
Calibration ControlAllows the operator to calibrate the instrument to one primary set
point (usually 100%) in accordance with the designated calibration
protocol. This protocol is defined further in this manual and also.
Instructions in abbreviated form can be found on the top of the
monitor casing.
High Alarm Setting Allows the operator to define a high alarm threshold limit. Range
18% to 102% - if the actual measured value as displayed on the
LCD exceeds this set threshold, an audible and visual alarm
condition will be invoked.
Low alarm setting KnobAllows the operator to define a low alarm threshold limit. Range
18% to 100% - if the actual measured value as displayed on the
LCD falls below this set threshold, an audible and visual alarm
condition will be invoked.
and provides a visual indication of either a high (+) or low (-) alarm
threshold violation.
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
6
EAR PANEL
R
ESCRIPTION OF FUNCTIONAL ZONES
D
Battery Drawer
Battery DrawerThe Battery Drawer contains 4 x AA (Penlight) batteries
required to power the instrument.
Sensor Cable Connector PlugThe Oxygen Sensor Connector Cable is plugged into this
“one way” socket.
Sensor Cable Connector Plug
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
7
ECTION ONE
S
PERATIONS
O
Note : Upon receipt, inspect the entire unit and accompanying accessories for damage or broken
or loose parts. If damaged, do not use. Notify the Shipper, and consult Teledyne
Electronic Technologies
Analytical Instruments
1.1 SET-U
To set-up your TED 191 Portable Oxygen Monitor :
1.1.1 Install the Batteries
See 1.2 below for procedure
1.1.2 Install the Sensor
See 1.3 below for procedure
1.1.3 Calibrate the Instrument
See 1.4 below for procedure
1.1.4 Normal Operation
See 1.5 below for procedure
1.1.5 Set the Alarms
See 1.6 below for procedure
P
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
8
PERATIONS
O
1.2 I
NSTALLING THE BATTERIES
Withdraw the battery drawer from the monitor casing, by grasping the side lugs located on
either side of the battery drawer, and, firmly pinching them inwards, simultaneously pull the
drawer outwards. When new, this action can be somewhat stiff and difficult to execute. Care
should be taken not to damage either the drawer or the casing of the monitor when
executing this procedure.
Fresh batteries must be inserted into the four battery recepticles located within the battery
drawer assembly. Care should be taken to ensure that the correct battery polarity is
maintained.
Caution : Improper installation of the batteries may result in heat damage to the
batteries.
Re-insert the battery drawer into the monitor casing, and close.
TELEDYNE ELECTRONIC TECHNOLOGIES
Analytical Instruments
9
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.