Instructions
WCA2UP-02 & RSA3UP-02
256 MB Data Memory with Frequency Mask Trigger
WCA230A & WCA280A
Portable Wireless Communication Analyzers
RSA3303A & RSA3308A
Real-Time Spectrum Analyzers
075-1267-01
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
www.tektronix.com
075126701

Copyright © Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

Kit Description
This kit provides parts and instructions to install the A30 trigger board and add
Option 02 (256 MB data memory with frequency mask trigger) to your
WCA230A and WCA280A Portable Wireless Communication Analyzers or
RSA3303A and RSA3308A Real-Time Spectrum Analyzers.
Products
WCA230A and WCA280A without Option 02
RSA3303A and RSA3308A without Option 02
Minimum Tool and Equipment List
Required tools and equipment Description
ScrewdriverĂhandle Accepts PhillpsĆdriver bits
#2 Phillips tip PhillipsĆdriver bit for #2 size screw heads
Kit Parts List
Fig. & index
number
606Ć0139Ć00
1Ć1 1ea 671ĆB162Ć50 CIRCUIT BD ASSY:A30
1Ć2 1 ea 334Ć1377Ć50 MARKER,IDENT
1Ć3 1ea 075Ć1267Ć00 INSTRUCTION MANUAL
Quantity Part number Description
WCA2UPĆ02 & RSA3UPĆ02
WCA2UP-02 & RSA3UP-02 Instructions
1

Kit Description
1
3
2
Figure 1: Kit parts
WCA2UP-02 & RSA3UP-02 Instructions
2

Installation Instructions
These instructions are for personnel who are familiar with servicing the product.
If you need further details for disassembling or reassembling the product, refer to
the WCA230A and WCA280A Service Manual (Tektronix part number
071-1257-XX) or the RSA3303A and RSA3308A Service Manual (Tektronix part
number 071-1412-XX).
CAUTION. To prevent static discharge damage, service the product only in a
static-free environment. Observe standard handling precautions for static-sensitive devices while installing this kit. Always wear a grounded wrist strap,
grounded foot strap, and static resistant apparel while installing this kit.
These installation instructions consist of three main processes:
H Installing the A30 trigger board
H Enabling 256 MB data memory and frequency mask trigger
H Verifying operation
WCA2UP-02 & RSA3UP-02 Instructions
3