xx
TPR1000 and TPR4000
Active Power Rail Probes
Complian
ce and Safety Instructions
Termsinthismanual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols and terms on the product
When this symbol is marked on the product, be
sure to consult the manual to find out the nature of
the potenti
to be taken to avoid them. (This symbol may also
be used to refer the user to ratings in the manual.)
al hazards and any actions which have
The following symbol(s) may appear on the product:
Complianc
e information
This product is intended for use by professionals and trained
personnel
only; it is not designed for use in households or by
children.
Questions about the following compliance information may be
directed to the following address:
Tektronix, Inc.
PO Box 500, MS 19-045
Beaverton, OR 97077, USA
www.tek.com
Environmental considerations
This section provides information about the environmental
impact of the product.
ion of hazardous substances
Restrict
Complies with RoHS2 Directive 2011/65/EU.
Key performance specifications
Specification Description
Oscilloscope
compatibility
Bandwidth in DC
coupling mode
Bandwidth in DC
reject mode
Linear dynamic
range
Offset range
Attenuation 1.25x
Measurement
accuracy
Noise
Input impedance
Offset ±60 V offset range
1
2
3
4
23
DPO70000 oscilloscopes require the optional TCA-VPI50 adapter.
Frequency response optimized for <1 Ω source impedance.
Through SMA-to-SMA cable or Solder Micro-Coax tip.
Max AC RMS of 1 V.
6 series MSO, 5 series MSO, MDO3000,
MDO4000C, MSO/DPO5000B, DPO7000C,
and DPO70000C/DX/SX
TPR1000: DC to 1 GHz
23
TPR4000: DC to 4 GHz
TPR1000: 10 kHz to 1 GHz
TPR4000: 10 kHz to 4 GHz
Up to 60 V DC, ±1 V
±60 V
2
DC linearity: <0.1%
Step response long-term aberrations: ±1%
<300 μV
BW Limit)
<1 mV
Bandwidth)
50 kΩ DC to 10 kHz
50 Ω AC > 1
Offset setting error: ±2 mV max, ±0.4 μV
typical
noiseon6SeriesMSO(20MHz
p-p
noise on 6 Series MSO (Full
p-p
p-p
00 kHz
1
oscilloscopes
to bandwidth
4
Standard accessories
Each probe is shipped with one TPR4KIT accessory kit
containing the following items:
Item Description
1.3 m cable, SMA male-to-MMCX
male, 50 Ω
1
*P0713
63701*
071-3637-01
Important Safety information
This manual contains information and warnings that must be
followed by the user for safe operation and to keep the product
in a safe condition.
To safely perform service on this product, additional
information is provided at the end of this section in the Service
safety summary.
General safety summary
Use the product only as specified. Review the following safety
precautions to avoid injury and prevent damage to this product
or any products connected to it. Carefully read all instructions.
Retain these instructions for future reference.
Probes and test leads
e connecting probes or test leads, connect the power cord
Befor
from the power connector to a properly grounded power outlet.
Inspect the probe and accessories. Before each use, inspect
and accessories for damage (cuts, tears, or defects in
probe
the probe body, accessories, or cable jacket). Do not use if
ged.
dama
High temperature probe tips
WARNING. To prevent a burn injury, when using a solder
micro-coax or flex tip in a high temperature application, be
sure to allow the tip to cool down before handling the tip.
Service safety summary
The Service safety summary section contains additional
information required to safely perform service on the product.
Only qualified personnel should perform service procedures.
Read this Service safety summary and the General safety
summary before performing any service procedures.
Do not service alone. Do not perform internal service or
adjustments of this product unless another person capable of
rendering first aid and resuscitation is present.
Product end-of-life handling
Observe the following guidelines when recycling an instrument
or component:
Equipment recycling. Production of this equipment required
the extraction and use of natural resources. The equipment may
contain substances that could be harmful to the environment or
human health if improperly handled at the product’s end of life.
To avoid release of such substances into the environment and
to reduce the use of natural resources, we encourage you to
recycle this product in an appropriate system that will ensure
that most of the materials are reused or recycled appropriately.
This symbol indicates that this product complies
with the applicable European Union requirements
according to Directives 2012/19/EU and
2006/66/EC on waste electrical and electronic
equipment (WEEE) and batteries. For information
cycling options, check the Tektronix Web
about re
site (www.tek.com/productrecycling).
Operating overview
The TPR1000 and TPR4000 probes provide a low noise, large
offset range solution for measurement of ripple on DC power
rails ranging from –60 to +60 VD C and measurement of AC
ripple between 200 μV
and1V
p-p
Refer to one of the following TPR1000 and TPR4000
Instruction Manuals for complete operating information and
product specifications. The manuals are available for download
at www.tek.com\downloads.
Language Tektronix part number
English 077-1542-xx
Japanese 077-1543-xx
Simplified
Chinese
077-1544-xx
Environmental specifications
Specification Description
Maximum input
voltage
Temperature
Humidity
Altitude 0 to 3000 m
DC: ±60 V
AC: ±30 V RMS
Pk-Pk: ±42 V peak
Probe body: 0 to +55 °C
Standard accessories: –40 to +125 °C
High-temp accessories: –55 to +155 °C
5 to 95% up to +40 °C, derate to 85% above
+40 °C
atupto4GHz.
p-p
1.3 m cable, SMA male-to-SMA male,
50 Ω
Y-lead adapter, MMCX
female-to-0.8 mm sockets
er cable, MMCX female-to-U.FL
Adapt
female, 50 Ω
Adapter, MMCX female-to-square pin
(0.062 centers)
nterface solder pins, set of 20
DUT i
Soldering aide tool, 0.062 solder pins
over SMT
Solder-in cable adapter, MMCX
female-to-solder micro-coax tip, 50 Ω,
setof3
Solder-in cable adapter, MMCX
female-to-solder flex-paddle tip, 50 Ω,
setof3
Wire card, solderable enameled
self-fluxing copper wire (for use with
the solder-in tips)
Probe tip tripod support (with living
hinge)
Marker bands, set of 5 (for probe
identification)
x

Optional high-temperature accessory kit
If you ordered the optional TPR4KITHT high-temperature
accessory kit, you received the following items:
Item Description
2 m high-temperature cable, SMA
male-to-MMCX male, 50 Ω
Solder-in cable adapter, MMCX
female-to-solder micro-coax tip, 50 Ω,
setof3
Solder-in cable adapter, MMCX
female-to-solder flex-paddle tip, 50 Ω,
setof3
Optional 1 GHz browser accessory kit
If you ordered the optional TPRBRWSR1G browser accessory
kit, you received the following items:
Item Description
Browser
Ground leads (blade, 0.5 mm spring,
15 cm alligator)
Y-lead adapter, browser tip-to-0.8 mm
sockets
1. To install the probe, slide the probe body into the
FlexChannel or VPI receptacle. The probe clicks into
place when fully engaged.
2. Attach one of the following probe cables to the SMA
connector on the probe body:
SMA-to-SMA standard cable (standard accessory)
SMA-to-MMCX standard cable (standard accessory)
SMA-to-MMCX high-temperature cable (optional
accessory)
1 GHz browser probe cable (optional accessory)
CAUTION. To prevent damage to the probe, do not exceed
8 in-lbs torque on the SMA nut.
3. To disconnect the probe, press the latch release button and
pull away from the instrument.
Attaching MMCX accessories
Gently insert the MMCX end of the cable into one of the
following accessories: micro-coax tip, solder flex tip, u.fl
adapter or MMCX to square pin Y-lead adapter, until you feel
the connector engage. To remove an accessory, gently pull
from the MMCX connection point.
Attaching solder-in accessories
Micro-coax tip. For convenient first-time use, the solder
micro-coax tips are shipped pre-trimmed and ready t o be
soldered to the test point. You can reuse a tip by removing the
tip from the solder joint and then trimming the wire insulation
back to expose the center pin and ground shield on the tip cable.
To achieve the best measurements results with a trimmed tip,
refer to the TPR1000 and TPR4000 User Manual for guidelines
and a description of best practices.
Flex tip. To attach the solder flex tip, first solder the enameled
self-fluxing copper wire (standard accessory) to the test point.
Feed the wire through the vias on the end of the flex tip, and
then apply a small amount of solder to the vias to attach the
wire to the tip.
Using the optional 1 GHz browser
The optional 1 GHz browser kit contains the following parts:
1 GHz browser probe, square pin Y-lead adapter, micro-SMD
clip, three ground leads (alligator, blade, spring), and four
replacement probe-tip pins (two rigid, two spring loaded).
WARNING. To prevent injury to the operator or damage
to the probe, oscilloscope and device under test, do not
touch the probe ground to any point that is not at the same
potential as the chassis ground of the oscilloscope. The
probe ground must be connected to the same potential as
the chassis ground of the oscilloscope.
Installing ground leads. To obtain accurate measurements,
always attach a ground lead to the probe tip before making
measurements. It is recommended that you use the shortest
ground lead that will function in your electrical application. The
following illustration shows the browser probe tip, the tip cover
and the three types of grounds leads supplied with the browser.
To install the ground leads:
Spring: Slide the ground lead over the probe tip until it
seats around the metal portion of the probe-tip housing.
Alligator: Slide the ground lead prongs over the exposed
metal between the plastic probe-tip sections.
Blade: Loc
ate the slot in the probe-tip housing as shown
below. Slide the ground lead over the probe tip until the
blade slid
es into the slot.
Micro-SMD clip
Replacement 0.5 mm browser tips
(2 solid tips, 2 spring tips)
Optional solder-in, micro -coax tip accessory kit
If you ordered the optional TPR4SIACOAX accessory kit, you
received the following items:
Item Description
Solder-in cable adapter, MMCX
female-to-solder micro-coax tip, 50 Ω,
setof3
Optional solder-in, flex-paddle tip accessory kit
If you ordered the optional TPR4SIAFLEX accessory kit, you
received the following items:
Item Description
Solder-in cable adapter, MMCX
female-to-solder flex-paddle tip, 50 Ω,
setof3
Installation
NOTE. Your FlexChannel or VPI instrument may require a
software upgrade to support full functionality of the TPR1000
and TPR4000 probes. Before you connect the probe to an
oscilloscope, refer to the required software versions table at the
end of this document to check the version requirements.
Using the solder-pin installation tool
The supplied set of solder pins are intended to be installed
on DUT circuit boards and used with the supplied
MMCX-to-square-pin adapter. To install the solder pins, use
the supplied soldering-aide tool as described below .
NOTE. The solder pins are extremely small and can be
challenging to handle. It is recommended to use tweezers and a
magnifying tool when installing pins on a circuit board.
1. Carefully insert the solder pins into the soldering aide tool
as shown below.
2. Use the soldering a ide tool to hold the solder pins in place
while soldering the pins to the circuit board.
3. If necessary, apply a small amount of adhesive to further
strengthen the connection to the circuit board. However,
keep the height of the adhesive to a minimum to provide
good electrical contact for the adapter.
Using the tripod
The tripod probe support adds stability to square-pin mounted
test points. For more stability, use glue to attach the tripod legs
to the DUT circuit board.
Connecting the Y-lead adapter and micro-SMD clip. The browser
udes a Y-lead adapter and a micro-SMD clip that connect
kit incl
as shown below. The Y-lead adapter can also connect to square
pins.
ng browser-tip pins. To remove the browser-tip pin, use
Replaci
pliers to grasp the pin and gently pull it out of the tip housing.
ll a new browser-tip pin, select between a solid (silver
To insta
colored) or spring-loaded (gold colored) pin, and then use pliers
y insert t he pin into the browser-tip housing until you
to gentl
feel the pin press against the bottom of the housing.
Required oscilloscope software versions
Oscilloscope Required software version
5and6SeriesMSO
MDO3000
MDO4000C
MSO/DPO5000B
DPO7000C
DPO70000C/DX/SX
1
The probe may operate with older versions of oscilloscope software. However,
older software versions than those listed are not guaranteed to provide ful
probe functionality.
1.12.5
1.274
1.09354
10.8.3.3
10.8.3.3
.1
10.9
62
1
l
Copyright © Tektronix, Inc. All rights reserved. www.tek.com