Features
Works with many Tektronix active and
passive probes
Use with single-ended, differential, and
high-voltage probes
Integral locking socket holds other probe
accessories in place
CAUTION. If you are probing circuitry
with dense conta
Tektronix recommends that you use insulated
probe tip acces
short-circuiting adjacent IC pins or circuitry.
ctssuchasICpins,
sories designed to prevent
TPH1000
Probe Holder
ZZZ
Instructions
*P071289401*
071-2894-01
TPH1000 Probe Holder
The TPH1000 probe holder is a probe accessory
that allows you to probe circuits and test points
hands-free, without using hook clips or tape to
keep the probe in contact with your circuit.
Probe Grips
Two probe grips are molded into the probe,
14 mm (0.55 in) and 9 mm (0.35 in) in diameter.
Use the smaller grip with Tektronix passive
probes, for example, the P6139B and P5050B.
Use the larger grip with Tektronix high voltage
probes like the P5100A and P5122.
To use the holder, insert the cable in the grip
opening and th
CAUTION. Do not pull the probe by the
cable; you may damage the probe. Always
insert and remove probes by gripping the
handheld section of the probe.
Position the base of the probe holder on your
circuit where it can maintain stability while
contacting the test point.
en slide the probe into the grip.
CAUTION. If your probe has exposed ground
contacts near t
avoid short-circuiting the probe to adjacent
circuitry.
You can also position the probe on the other side
of the holder a
TPH1000 Probe Holder Dimensions
Characteristic Description
Length
Width
Height
Probe Grips (2) 14 mm (0.55 in) and
Weight
he probe tip, be careful to
s shown below.
63.5 mm (2
11 mm (0.44 in )
99 mm (3.9 in)
9mm(0.35in)
55 gm (1.9 oz)
.5 in)
The weight of the probe holder keeps the probe in
contact with your circuit, and the non-skid base
keeps the probe holder in place. The probe holder
is insulated to prevent short-circuits, and the two
probe grip areas accept a wide variety of probes.

Safety Informat
ion
Connect and Disconnect Properly. Connect the
probe output to t
he measurement instrument
before connecting the probe to the circuit under
test. Disconne
ct the probe input and the probe
reference lead from the circuit under test before
disconnecting
the probe from the measurement
instrument.
Avoid Electric Shock. To avoid injury or loss
of life, do not c
onnect or disconnect probes or
test leads while they are connected to a voltage
source.
Warranty Inform
ation
For warranty information, go to
www.tektronix.
com/warranty.
Contacting Tekt
Web site: www.tektronix.com
Phone: 1-800-833-920
Address: Tektronix, Inc.
Email:
ronix
0
Department or name (if known)
14200 SW Karl Br
P.O. Box 500
Beaverton, OR 97077 USA
techsupport@tektronix.com
aun Drive
opyright © Tektronix, Inc. All rights reserved. www.tek.com