Tektronix TPH1000 Probe Holder Instructions User manual

Features
Works with many Tektronix active and passive probes
Use with single-ended, differential, and high-voltage probes
Integral locking socket holds other probe accessories in place
CAUTION. If you are probing circuitry with dense conta Tektronix recommends that you use insulated probe tip acces short-circuiting adjacent IC pins or circuitry.
ctssuchasICpins,
sories designed to prevent
TPH1000 Probe Holder
ZZZ
Instructions
*P071289401*
071-2894-01
TPH1000 Probe Holder
The TPH1000 probe holder is a probe accessory that allows you to probe circuits and test points hands-free, without using hook clips or tape to keep the probe in contact with your circuit.
Probe Grips
Two probe grips are molded into the probe, 14 mm (0.55 in) and 9 mm (0.35 in) in diameter. Use the smaller grip with Tektronix passive probes, for example, the P6139B and P5050B. Use the larger grip with Tektronix high voltage probes like the P5100A and P5122.
To use the holder, insert the cable in the grip opening and th
CAUTION. Do not pull the probe by the cable; you may damage the probe. Always insert and remove probes by gripping the handheld section of the probe.
Position the base of the probe holder on your circuit where it can maintain stability while contacting the test point.
en slide the probe into the grip.
CAUTION. If your probe has exposed ground contacts near t avoid short-circuiting the probe to adjacent circuitry.
You can also position the probe on the other side of the holder a
TPH1000 Probe Holder Dimensions
Characteristic Description
Length
Width
Height
Probe Grips (2) 14 mm (0.55 in) and
Weight
he probe tip, be careful to
s shown below.
63.5 mm (2
11 mm (0.44 in )
99 mm (3.9 in)
9mm(0.35in)
55 gm (1.9 oz)
.5 in)
The weight of the probe holder keeps the probe in contact with your circuit, and the non-skid base keeps the probe holder in place. The probe holder is insulated to prevent short-circuits, and the two probe grip areas accept a wide variety of probes.
Safety Informat
ion
Connect and Disconnect Properly. Connect the
probe output to t
he measurement instrument before connecting the probe to the circuit under test. Disconne
ct the probe input and the probe reference lead from the circuit under test before disconnecting
the probe from the measurement instrument.
Avoid Electric Shock. To avoid injury or loss of life, do not c
onnect or disconnect probes or test leads while they are connected to a voltage source.
Warranty Inform
ation
For warranty information, go to www.tektronix.
com/warranty.
Contacting Tekt
Web site: www.tektronix.com
Phone: 1-800-833-920
Address: Tektronix, Inc.
Email:
ronix
0
Department or name (if known) 14200 SW Karl Br P.O. Box 500 Beaverton, OR 97077 USA
techsupport@tektronix.com
aun Drive
opyright © Tektronix, Inc. All rights reserved. www.tek.com
C