Tektronix TPA-N-VPI Instruction Manual

TPA-N-VPI Probe Adapter
ZZZ
Instructions
*P071296700*
071-2967-00
Safety Summary
To avoid potential hazards, use this product only as specied.
To avo id re or personal injury
TPA-N-VPI Adapter to the host instrument before connecting the device to the circuit-under-test. Disconnect the device input and ground from the circuit under test before disconnecting the device from the adapter and host instrument.
Ground the product. This product is indirectly grounded through the grounding conductor of the host instrument power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the host instrument. Consult the host instrument documentation for further ratings information before making connections to the host instrument.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not operate wi
thout covers. Do not operate
this product with covers or panels removed.
Do not operate with suspected failures. If you suspect there i
s damage to this product, have it
inspected by qualied service personnel.
Do not operate in wet/damp conditions.
Do not operate i
n an explosive atmosphere.
Keep product surfaces clean and dry.
Environmental
Considerations
This section provides information about the environmenta
l im pact of the product.
Equipment Recycling. This product complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). For more information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Product Description
The TPA-N-VPI Adapter accepts probes with BNC, TekProbe™, and TekVPI™ outputs and allows you to use them on instruments that use an N-type RF input connector.
The adapter does not require pow er, and does not affect the scale factor of the attached probe. The adapter works with passive, active, and differential voltage probes with 50 outputs.
NOTE. If your probe connects with an N connector, connect your probe directly to the N connector input.
Installing the A
dapter
1. Align adapter to input N connector.
2. Rotate thumbwheel clockwise to tighten.
3. Connect probe to adapter input.
Specications
Characteristic Specication
Bandwidth
Attenuation
VSWR 1.3:1 D
Temperature
Operating 0 °C to 50 °C
Nonoperating
Humidity
Operating 0–40 °C 10–60% RH
Nonoperating
Altitude
Operating 3000 m (10,000 ft)
Nonoperating
Dimensions
xWxH)
(L
6GHz
0.5dBDCto6GHz
Cto6GHz
(32 °F to 122 °F)
–20°Cto+60°C (4 °F to 140 °F)
40–50 °C 10–90% R H
0–40 °C 5–90% RH
0°C5–60%RH
40–6
12,000 m (40,000 ft)
5.0 x 2.66 x 3.96 cm .0 x 1.05 x 1.56 in)
(2