Tektronix TL704H User Manual

x
TL704H TekLink 4 Port Instrument Hub
ZZZ
User Manual
*P071211401*
071-2114-01
xx
TL704H TekLink 4 Port I nstrument Hub
ZZZ
User Manual
www.tektronix.com
071-2114-01
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TekLink is a registered trademark of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O . B o x 5 00 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to nd contacts in your area.
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of sh ipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective pro duct without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect befo re the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be res ponsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned t o any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the pro duct; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX W IT H RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER T EKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
[W2 – 15AUG04]
Table of Contents
General Safety Summary . . ................................................................................................................ iii
Compliance Information .................................................................................................................... vi
EMC Compliance ..................................................................................................................... vi
Environmental Considerations....................................................................................................... viii
Preface...................................................................................................................................... ix
Key Features.......................................................................................................................... ix
Installation .................................................................................................................................. 1
Standard Accessories ................................................................................................................ 1
Optional Accessories ................................................................................................................. 2
Controls an d Connectors . ............................................................................................................ 3
Connecting Power .................................................................................................................... 4
Connecting Cables.................................................................................................................... 6
Mounting the Hub . .................................................................................................................... 7
Troubleshooting............................................................................................................................. 8
Specications.............................................................................................................................. 11
Table of Contents
TL704H TekLink 4 Port Instrument Hub User Manual i
Table of Co ntents
ii TL704H TekLink 4 Port Instrument Hub User Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied.
Only qualied personnel should pe rform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
To Avoid Fire or Personal Injury
Use Proper Power Cord. Use only the power cord specied for this product and certied for the country of use.
Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock,
the grounding conductor must be connected to earth ground. Before making connections to the input or output termina ls of the product, ensure that the product is properly ground ed.
Observe All Terminal Ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult the
product manual for further ratings information before making connections to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Power Disconnect. The power cord disconnects the product from the power source. Do not block the powe r cord; it must remain
accessible to the user at all times.
Do Not Operate Without Covers. Do not operate this product with covers or panels removed.
General Safety Summary
Do Not Operate With Suspected Failures. If you suspect that there is damage to this product, have it inspected by qualied
service personnel.
TL704H TekLink 4 Port Instrument Hub User Manual iii
General Safety Summary
Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present.
Use Proper AC A dap ter. Use only the AC adapter specied for this product.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
TermsinthisManual
These terms may appear in this ma nual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Symbols and Terms on the Product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
iv TL704H TekLink 4 Port Instrument Hub User Ma nual
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
General Safety Summary
TL704H TekLink 4 Port Instrument Hub User Manual v
Compliance Information
Compliance Information
This section lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument complies.
EMC Compliance
EC Declaration of Conformity – EMC
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following specications as listed in the Ofcial Journal of the European Co mmunities:
EN 61326-1 2006. EMC r equirements for electrical equipment for measurement, control, and laboratory use.
CISPR 11:2003. Radiated and conducted emissions, Group 1, C lass A
IEC 61000-4-2:2001. Electrostatic discharge immunity
IEC 61000-4-3:2002. RF electromagnetic eld immunity
IEC 61000-4-4:2004. Electrical fa st transient / bu rst immunity
IEC 61000-4-5:2001. Power line surge immunity
IEC 61000-4-6:2003. Conducted RF immunity
IEC 61000-4-11:2004. Voltage dips and interruptions immunity
EN 61000-3-2:2006. AC power line harmonic emissions
EN 61000-3-3:1995. Voltage changes, uctuations, and icker
vi TL704H TekLink 4 Port Instrument Hub User Manual
3
12
Compliance Information
European Contact.
Tektronix UK, Ltd. Western Peninsula Western Road Bracknell, RG12 1RF United Kingdom
1
This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
To ensure compliance with the EMC standards listed here, high-quality shielded interface cables should be used.
3
Performance Criterion C applied at the 70%/25 cycle Voltage-Dip and the 0%/250 cycle Voltage-Interruption test levels (IEC 61000-4-11).
Australia / New Zealand Declaration of Conformity – EMC
Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR 11:2003. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006.
TL704H TekLink 4 Port Instrument Hub User Manual vii
Compliance Information
Environmental Considerations
This section provides information about the environmental impact of the prod uct.
Product End-of-Life Handling
Observe the following guidelines when recycling an instrument or compo nent:
Equipment Recycling. Production of this equipment required the extraction and use of natural resources. The equipment may
contain su bstances that could be harmful to the environment or human health if improperly handled at the product’s end of life. In order to avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of th e Tektronix Web site (www.tektronix.com).
Restriction of Hazardous Substances
This product has been classied as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive.
viii TL704H TekLink 4 Port Instrument Hub User Manual
Preface
This manual describes the installation and operation of the TL704H TekLink 4 Port Instrument Hub. The hub allows you to connect up to 4 instruments together into a test and measurement network (a TekLink system). The multi-instrument TekLink system has hardware and software features available beyond the capabilities of a single instrument.
Key Features
Key features include:
Four ports allowing any four TekLink-equipped instruments to form a TekLink system
Complex trigger functions from multiple instruments
Interoperability between logic analyzers, oscilloscopes, signal sources, and spectrum analyzers.
Sharing trigger events, reference clocks and GPIB commands between instruments in the TekLink system
Preface
Instrument TekLink Hub TekLink Instrument
TL704H TekLink 4 Port Instrument Hub User Manual ix
Preface
x TL704H TekLink 4 Port Instrument Hub User Manual
Installation
Unpack the hub and check that you received all o f the items listed below as standard accessories. Check the Tektronix Web site (www.tektronix.com) for the most current information.
Standard Accessories
Description Part number
User Manual 071-2114-01
External power supply (and one of the following:)
United States power cord
Universal European power cord 161-0066-09
United Kingdom power cord 161-0066-10
Australia power cord 161-0066-13
Switzerland power cord
Japan power cord 161-A005-00
China power cord
India/South Africa power cord
No power cord or power supp ly (Option A99)
Installation
119-5883-00
161-0066-00
161-0154-00
161-0304-00
161-0400-00
TL704H TekLink 4 Port Instrument Hub User Manual 1
Installation
Optional Accessories
Description Part number
TekLink cable 174-5019-xx
2 TL704H TekLink 4 Port Instrument Hub User Manual
Controls and Connectors
1. Port connectors for connection to each
instrument.
2. Port Status indicators. LEDs indicate the presence of a TekLink connection and blink whe n commands are issued over the TekLink system. (See Table 1 on page 10.)
3. Power Connector. For use with the external power supply, Tektronix part number 119-5883-00.
Installation
TL704H TekLink 4 Port Instrument Hub User Manual 3
Installation
Connecting Power
Connect power to the hub using the external power supply:
Connecting the External Power Supply
To apply power to your hub from the external power supply, do the following procedure :
1. Connect th e output power cable from the power supply to the 5 VDC connector on the rear panel of the hub.
2. Connect one end of the power cord to the external power supply.
3. Connect the other end of the power cord to the wall power outlet.
4 TL704H TekLink 4 Port Instrument Hub User Manual
4. Verify that the status LEDs turn on and
then off. The LEDs remain off until a TekLink instrument is connected to the hub, establishing a TekLink connection.
Installation
TL704H TekLink 4 Port Instrument Hub User Manual 5
Installation
Connecting Cables
NOTE. The following cables can be connected w hile the instruments are powered on.
To connect the hub to TekLink cables, do the following procedure:
1. Connect a TekLink cable to a TekLink port on the hub.
2. Connect the other end of the TekLink cable to the co nnector on the instrument.
6 TL704H TekLink 4 Port Instrument Hub User Manual
Mounting the Hub
You can mount the hub to a surface, such as a n existing rackmount tray or to a bracket of your design, by doing the following procedure:
1. Remove the four adhesive-backed, plastic
feet from the hub.
2. Refer to the dimensions shown in the
illustration, and drill holes in the mounting surface for two screws.
CAUTION. Using screws that are to o long will
damage the internal circuitry. Screws should enter the chassis 0.4in. (1.03cm).
3. Mount the hub using two 6-32 screws of
appropriate length.
NOTE. Some rackmount kits have provisions
for mounting accessories, such as the hub.
Installation
TL704H TekLink 4 Port Instrument Hub User Manual 7
Troubleshooting
Troubleshooting
Before starting to troubleshoot, note the following:
There are no use r serviceable parts.
Thereisnoperformanceverification procedure.
If your hub does not appear to work, do the following checks:
1. Check the cables.
The TekLink cables should be fully inserted on both the TekLink hub and the instrument. Failure means the cables were not inserte d correctly or the cables failed.
2. Check the power.
There is no direct indication the hub is powered on. You must check power by observing the status LEDs on the ports. Remove the power cord and plug the power cord back in. The status L EDs should briefly flash amber and then turn off. Failure implies either the hub power system failed or the external power supply failed.
8 TL704H TekLink 4 Port Instrument Hub User Manual
3. Check the port s tatus LED.
A status LED should be illuminated amber if you expect a TekLink connection to exist. There are periods of time when TekLink will not function:
When an instrument is rst powering on; the operating system drives the TekLink hardware and it is necessary for the operating syste m to be running to establish a TekLink connection.
Whenahubisrst powering on: the hub will perform initialization tasks before establishing a TekLink connection.
Failure implies the cable may be bad , the TekLink Ethernet device in the instrument has failed, or the Ethernet system in the hub has failed.
Troubleshooting
TL704H TekLink 4 Port Instrument Hub User Manual 9
Troubleshooting
4. Check the indicator lights.
Table 1: Hub status LED
Color Illumination Description
None
The Hu b Status indicator lights on the hub should be in their normal settings. To check them, refer to the following table:
Solid
Blinking TekLink c ommu nication is occurring over the connection.
Off The hub is e ither off or waiting for a TekLink connection.
A TekLink connection has been established with an instrument.Yell o w
10 TL704H TekLink 4 Port Instrument Hub User Manual
Specications
Miscellaneous characteristics
Characteristic Description
Current Consumption <0.5 ADC from 5 V
Atmospherics
Characteristic Description
Temperature
Specications
Operating:
0°Cto+50°C(32°Fto+122°F)
Nonoperating:
–20°Cto+60°C(–4°Fto+140°F)
TL704H TekLink 4 Port Instrument Hub User Manual 11
Specications
Atmospherics (cont.)
Characteristic Description
Humidity
Altitude
Physical characteristics
Characteristic Description
Height
Width
Depth
Weight
Operating:
High: 40 °C to 50 °C (104 °F to 122 °F), 10% to 60% re la tive hum idity
Low: 0 °C to 40 °C (32 °F to 104 °F), 10% to 90% relative humidity
Nonoperating:
High: 40 °C to 60 °C (104 °F to 140 °F), 5 % to 60% relative humidity
Low: 0 °C to 40 °C (32 °F to 104 °F), 5% to 90% relative humidity
Operating:
Up to 3,000 m (10,000 ft.)
Nonoperating:
Up to 15,240 m (50,000 ft.)
48.25 mm (1.90 in)
133.35 mm (5.25 in)
133.35 mm (5.25 in)
560 g (1.25 lb)
12 TL704H TekLink 4 Port Instrument Hub User Manual