Kit Description

The TDSXF13 kit includes parts and instructions for installing Option 13: RS-232/Centronics Interface into the oscilloscopes listed under Instruments.

Instruments

TDS500A and later All serial numbers TDS620A/B All serial numbers TDS640A All serial numbers TDS680B All serial numbers

Minimum Tools and Equipment List

Tool Part number
One screwdriver with a size T-20 Torx tip n/a One screwdriver with a size T-15 Torx tip n/a Torque driver capable of 16 inch-pounds
(1.81 newton-meters)
n/a

Kit Parts List

RS-232/Centronics Upgrade Kit
The following table and Figure 1 identify the parts list for this kit.
Qty Part number Name & description
1 ea 070-9634-xx Manual, tech instructions;TDSXF13 1 ea 070-8567-xx Manual tech: Option 13 RS-232/Centronics 1 ea 672-1397-00 Circuit board assy: ECB/Brkt Assy consisting of the
following: (see Figure 1): 1 ea 671-2437-00 Circuit board assy: RS-232/Centronics 2 ea 407-3825-00 Bracket, ckt bd: plastic, rear 1 ea 386-6182-00 Plate, rear: aluminum, RS-232/Centronics 4 ea 131-0890-01 Lock, connector: 4-40 X 0.312 L, hex hd, stl 2 ea 348-1300-00 Shield, gasket, clip on
1
TDSXF13
Rear plate
Figure 1: RS-232/Centronics hardcopy interface replaceable parts

Service Safety Summary

WARNING. The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to the General Safety Summary in the appropriate TDS service manual before performing any service.
RS-232/Centronics
circuit board
Bracket
Connector lock
Do Not Service Alone
Avoid Exposed Circuitry
Use Care When Servicing
With Power On
2
Do not perform internal service on this product unless another person capable of rendering first aid and resuscitation is present.
To avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do not touch exposed connections and components when power is present.
Dangerous voltages or currents may exist in this product. Disconnect the power, remove the battery (if applicable), and disconnect the test leads before removing protective panels, soldering, or replacing components.