Getting Started with TDSJIT3 and TDSJIT3E
Y ou can use this side of the Quick Reference to get started
taking measurements with the Jitter Analysis Measurements
Application (TDSJIT3 or TDSJIT3E). The other side
contains a complete menu tree for TDSJIT3 and TDSJIT3E
software.
NOTE. For complete operating instructions
and General Safety information, refer to the
Online Help for the application.
The TDSJIT3 and TDSJIT3E applications represent third
generation jitter analysis tools from Tektronix. TDSJIT3
includes random and deterministic jitter separation (Rj/Dj)
and bit error ratio estimation (BER). These applications are
designed to meet general purpose testing requirements.
Requirements
H TDS5000, TDS5000B, TDS6000, TDS/CSA7000B or TDS/
CSA7000 oscilloscope
H TDSJIT3/TDSJIT3E Jitter Analysis Software
H 1 m BNC to BNC coaxial cable or voltage probe
appropriate to connect to probe compensation signal
H BNC TCA (TDS6000 and some TDS7000 models)
To set up the oscilloscope, follow these steps:
1. In the oscilloscope front panel, press the DEFAULT
SETUP button. This sets the oscilloscope into a known
state for this example only.
NOTE. You do NOT need to perform step 1
before each jitter measurement.
2. Connect the BNC cable between the PROBE
COMPENSATION Signal BNC and the CH 1 BNC.
3. Press the AUTOSET button.
4. Set up the following Vertical menu controls:
H Select 50 Ω Termination
H Adjust CH 1 Scale to 100 mV
H Adjust CH 1 Offset to 900 mV
H Adjust Position to 0
5. Press the RUN/STOP button to set the oscilloscope to
the RUN mode.
6. Set up the following Horizontal menu controls:
H Adjust the Horizontal Scale to 40 ms/div
H Adjust the Record Length to 200000
An alternative method to set these Horizontal controls is
through the front panel knobs, as follows:
H Turn the HORIZONTAL SCALE knob to set the
value; a readout below the lower right quadrant of the
graticule indicates the value
H Turn the Resolution knob to adjust the acquisition
rate to 500 kS/s, 2 µs/pt
The oscilloscope displays a free running waveform,
about 1.5 divisions high.
To set up the TDSJIT3 or TDSJIT3E application, follow
these steps:
1. Select File> Run Application> Jitter Analysis 3 (or Jitter
Analysis 3 Essentials) in the oscilloscope menu bar.
NOTE. There will be a short delay while the
application is loading.
2. In the application menu bar, go to the Measurements>
Select menu.
3. Press the Clock Period measurement button.
NOTE. The default measurement source is
CH 1. You can select other channels and
waveform sources through the pull-down
Select Source menu.
After you select a measurement, the name of
the measurement appears in the list on the
right that shows selected measurements and
their sources. To delete a measurement, press
the select button next to the measurement
name, and press the CLEAR button.
4. Select the Measurements> Configure> Source Reference
Levels tab, and press the AUTOSET All Active Sources
button.
NOTE. This sets the reference levels for all
sources defined in the measurement list. To
modify what the Autoset function uses as
midpoint, high, and low refer ence levels, press
the AUTOSET Setup button. To Autoset a
source for a single measurement, press the
appropriate button from the Select Source list,
and then press AUTOSET Selected Source.
5. Press the Go To Results button (bottom button on the
left of the screen), and select the All Statistics tab (which
is the default).
6. Press the Measure Single sequence button (last one on
the right of the screen) to start the measurement process.
The oscilloscope acquires a waveform and transfers it to
the application. The application performs edge detection
and timing analysis, calculates statistics, and displays
measurement results.
NOTE. The Results menu includes several tabs.
The All Statistics tab shows complete statistics
for each measurement. To select a different
measurement to display, press the selection
button next to the measurement list. To select
a summary of partial details of all
measurements, select the Min/Max or the
Mean/Std Dev tabs.
To obtain maximum accuracy use the highest
sample rate available on the instrument, for
example 20 GS/s on a TDS6604. Also make
the vertical size of the signal at least 4
divisions; ideally between 7 and 8 divisions.
TDSJIT3 Ordering Information
This application supports the TDS5000B, TDS5000,
TDS6000, TDS/CSA7000B or TDS/CSA7000
oscilloscopes; refer to the Optional Applications Software
on Windows-Based Oscilloscopes Installation Manual for a
list of specific models. The applications CD includes a PDF
file of the installation manual.
If Option JT3 was ordered with your new TDS or CSA
oscilloscope:
H TDSJIT3 is installed and enabled
To order an upgrade for an existing oscilloscope:
H Order TDS5UPB Option JT3
H Order TDS5UP Option JT3
H Order TDS6UP Option JT3
H Order TDS7BUP Option JT3
H Order TDS7UP Option JT3
H Order CSAB7UP Option JT3
H Order CSA7UP Option JT3
To order an upgrade for TDSJIT3E to TDSJIT3:
H Order TDS5BUP Option J23
H Order TDS5UP Option J23
H Order TDS6UP Option J23
H Order TDS7BUP Option J23
H Order TDS7UP Option J23
H Order CSA7BUP Option J23
H Order CSA7UP Option J23
TDSJIT3 Essentials Ordering Information
This application supports the TDS5000, TDS5000B,
TDS6000, TDS/CSA7000B or TDS/CSA7000
oscilloscopes; refer to the Optional Applications Software
on Windows-Based Oscilloscopes Installation Manual for a
list of specific models. The applications CD includes a PDF
file of the installation manual.
If Option J3E was ordered with your new TDS or CSA
oscilloscope:
H TDSJIT3 Essentials is installed and enabled
To order an upgrade for an existing oscilloscope:
H Order TDS5BUP Option J3E
H Order TDS5UP Option J3E
H Order TDS6UP Option J3E
H Order TDS7BUP Option J3E
H Order TDS7UP Option J3E
H Order CSA7BUP Option J3E
H Order CSA7UP Option J3E
Recommended Accessories
AWG710 — 4.0 GS/s Arbitrary Waveform Generator
P7260 — 6.0 GHz active probe
--3 dB probe tip bandwidth with TDS6604
P7240 — 4.0 GHz active probe
--3 dB probe tip bandwidth with CSA/TDS7404
P7380SMA — 8 GHz differential adapter
P7350SMA — 5G Hz differential SMA probe
P7350 — 5G Hz differential probe
--3 dB probe tip bandwidth with TDS6604 and above
P7330 — 3.0 GHz active differential probe
--3 dB probe tip bandwidth with CSA/TDS7404
TDSJIT3 and TDSJIT3E
Jitter Analysis Measurements
Application Reference
www.tektronix.com
*P071107902*
071-1079-02

TDSJIT3/TDSJIT3E Menu Tree
File
Measurements
Results
Plot
Log
Utility
Help
Control Panel (Visible
under Results, Plot,
and Utility menus)
Default Setup
Recall...
Save . . .
Recent Files
Minimize
Exit
Select...
Configure . . .
Summaryof...
All Statistics
Min/Max
Mean/Std Dev
TIE : RjDj -- BER*
Create
Vert/Horiz Axis
Statistics
Measurements
Worst Case Waveforms
Deskew
Acq Timeout
Warnings
Topics . . .
About TDSJIT3 . . .
Plots
Measure
OK | Cancel
File browser
Open | Cancel
File browser
Save | Cancel
List of Files to Recall
Yes
No
Cancel
Meas Setup Sequence
Select Source
Math Defs
Add Measurement
Clear | Clear All
Meas Setup Sequence
Meas Params
Source Autoset
Source Gate/Qualify
Source Ref Levels
Stat Pop Limit
Meas Setup Sequence
Measurements | Source Ref Levels | Miscellaneous
Measurement; Sources
Statistics; Current Acq; All Acqs
All Acqs | Current Acq
All Acqs | Current Acq
Analysis
Pattern Len
BER = 1E--?
Add Plot
Plots
Clear | Clear All
Modify Axis
Log Statistics
Save Current Statistics
Config
File names
Config
File names
Specify Deskew Sources
User Edges
Deskew Range
Perform Deskew
Summary
Acquisition Timeout
Warning History
Select View
Run/Stop
Single
Clear
Restore Scope Settings
Select Meas | Configure | View Summary | Go to
Clock
Data
Clk-Data
General
Math1
Math2
Math3
Math4
Clock
Data
Clock-Data
General
Select Meas | Configure | View Summary | Go to
Measurement dependent; refer to Online Help
Select Acq Source
Gate
Qualify with Logic Waveform
Select Source
Set Reference Level
Population Control
Select Meas | Configure | View Summary | Go to Results
Measurement; Sources; Population; Max; Min; Max + ∆; Max -- ∆
Measurement; Sources; Population; Mean; StdDev
On | Off
Histogram | Time Trend | Cycle Trend | Spectrum | Bathtub*
Plot dependent; refer to Online Help
Plot dependent; refer to Online Help
Path to filename
On | Off | Delete
Path to filename
Save | Delete
Log Measurements
Save Current Measurements
Measurement; Sources; File Names
Log Worst Case Waveforms
Refer to Online Help for a list of default filenames
Reference
Target
Rise | Fall | Both
Max. Value | Min. Value
Auto
User — Timeout
View | Clear
Active Plots Summary
(position plots)
Close
<< Less
New Acq Yes | N o
Results
Clock
Data
Clock
Data
Main
Slew/Cross
Scope User | Ch1--Ch2 | Ch3--Ch4 | Ref1--Ref2 | Ref3--Ref4
Scope User | Ch1--Ch2 | Ch3--Ch4 | Ref1--Ref2 | Ref3--Ref4
Period | Frequency | TIE | PLL TIE* | Cycle-Cycle | Positive Cy-Cy Duty |
Positive Duty Cycle | N-Cycle | Negative Cy-Cy Duty | Negative Duty Cycle
Period | Frequency | TIE | PLL TIE*
Setup | Hold | Clock--Out
Rise Time | Positive Width | High Time | Skew | Fall Time | Negative Width |
Low Time | Crossover Voltage*
Ch1 | Ch2 | Ch3 | Ch4 | Ref1 | Ref2 | Ref3 |
Ref4 | Math1 | Math2 | Math3 | Math4
Results
Autoset
Off | Zoom | Cursors
Source
Active
Ch | Ref | Math
Autoset
Rise
Fall
Hysteresis
Off
On — Size
Directory
On | Off | Delete
Directory
Save | Delete
Directory
On | Off | Delete
Source | Mid | Hysteresis
Source | Mid | Hysteresis
Vertical Scale | Horizontal Resolution | All Vert & Horiz
Ch1—4|Ref1—4|Math1—4
Off | High | Low
Setup | Selected Source | All Active Sources
High | Mid | Low
High | Mid | Low
* These measurements are only available in TDSJIT3.
Copyright Tektronix, Inc.