This document applies to software version 1.0.0
and above.
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the
Rights in T echnical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the
Commercial Computer Software – Restricted Rights clause at F AR 52.227-19, as applicable.
T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A.
T ektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.
WARRANTY
T ektronix warrants that the media on which this software product is furnished and the encoding of the programs on the media
will be free from defects in materials and workmanship for a period of three (3) months from the date of shipment. If a
medium or encoding proves defective during the warranty period, T ektronix will provide a replacement in exchange for the
defective medium. Except as to the media on which this software product is furnished, this software product is provided “as
is” without warranty of any kind, either express or implied. T ektronix does not warrant that the functions contained in this
software product will meet Customer’s requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the
warranty period. If T ektronix is unable to provide a replacement that is free from defects in materials and workmanship
within a reasonable time thereafter, Customer may terminate the license for this software product and return this software
product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO
REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S PAYMENT IS THE SOLE AND EXCLUSIVE
REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS
VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT , SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF
THE POSSIBILITY OF SUCH DAMAGES.
Figure 24: Example of a Period measurement and the results33. . . . . .
TDSJIT1 Jitter Analysis Application User Manual
iii
Table of Contents
iv
TDSJIT1 Jitter Analysis Application User Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it. To avoid potential hazards, use this
product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read
the General Safety Summary in other system manuals for warnings and cautions
related to operating the system.
Connect and Disconnect Properly . Connect the probe output to the measurement
instrument before connecting the probe to the circuit under test. Disconnect the
probe input and the probe ground from the circuit under test before disconnecting
the probe from the measurement instrument.
Do not apply a potential to any terminal, including the common terminal, that
exceeds the maximum rating of that terminal.
Symbols and Terms
T erms in this Manual. This term may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
TDSJIT1 Jitter Analysis Application User Manual
v
General Safety Summary
vi
TDSJIT1 Jitter Analysis Application User Manual
Preface
Related Documentation
Conventions
This manual contains operating information for the TDSJIT1 Jitter Analysis
Application. The manual consists of the following chapters:
HThe chapter Getting Started briefly describes the TDSJIT1 Jitter Analysis
Application and provides installation instructions.
HThe chapter Operating Basics covers basic operating principles of the
application and includes a tutorial.
HThe chapter Reference describes how to perform specific tasks.
Your oscilloscope user manual provides operating instructions for general
oscilloscope features.
This manual uses the following conventions:
HThis manual refers to the TDSJIT1 Jitter Analysis Application as either the
Jitter Analysis Application or as the application.
HWhen steps require that you make a sequence of selections using front panel
controls and menu buttons, an arrow ( ➞
front panel button and a menu, or between menus. Names that are for a main
menu or side menu item are clearly indicated: Press VERTICAL MENU ➞
For application-oriented questions about a Tektronix measurement product, call toll free in North America:
1-800-TEK-WIDE (1-800-835-9433 ext. 2400)
6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail:
tm_app_supp@tek.com
For product support outside of North America, contact your
local Tektronix distributor or sales office.
Contact your local Tektronix distributor or sales office. Or visit
our web site for a listing of worldwide service locations.
http://www.tektronix.com
In North America:
1-800-TEK-WIDE (1-800-835-9433)
An operator will direct your call.
P.O. Box 1000
Wilsonville, OR 97070-1000
viii
TDSJIT1 Jitter Analysis Application User Manual
Getting Started
Product Description
The TDSJIT1 Jitter Analysis Application is a Java-based application that
enhances the jitter analysis capability of Tektronix TDS oscilloscopes. The
application offers many of the same timing measurements and two additional
measurements: Cycle-to-Cycle and N-Cycle.
Oscilloscopes can take only one measurement in an acquisition waveform. The
TDSJIT1 application can take and accumulate measurements throughout an
entire waveform.
The application can display the measurement results three ways: as Statistics, in
a Histogram graphical format, or in a Profile graphical format (measurement
versus measurement index numbers).
Figure 1 shows an example of the Histogram format of a period measurement.
Figure 1: TDSJIT1 Jitter Analysis Application
Compatibility
The Jitter Analysis Application is compatible with the following Tektronix
oscilloscopes:
HAll TDS 500D and 700D Digital Phosphor Oscilloscopes with Option HD
(hard disk drive) or Option 2M (hard disk drive plus 8 MB record length)
HTDS 600C Digitizing Oscilloscopes with an Option HD (hard disk drive)
HTDS 700C Color Digitizing Oscilloscopes serial number B020100 and up,
with Option HD (hard disk drive) or Option 2M (hard disk drive plus 8 MB
record length), and with firmware version 5.2e and up
TDSJIT1 Jitter Analysis Application User Manual
1
Product Description
For a current list of compatible oscilloscopes, check the Tektronix, Inc. web site,
http://www.tektronix.com/Measurement/scopes/index.html
Drivers category.
Requirements and Restrictions
The TDS Run-Time Environment V1.1 and above must be installed on the
oscilloscope to operate the Jitter Analysis Application.
The application does not support control by external GPIB commands.
Updates
You can find information about this and other applications at the Tektronix, Inc.
web site, http://www.tektronix.com/Measurement/scopes/index.html
Software and Drivers category. Check this site for application updates that you
can download and for free applications.
in the Software and
in the
Accessories
There are no standard accessories for this product.
2
TDSJIT1 Jitter Analysis Application User Manual
Installation
This application resides on a floppy disk. You can download updates, if any, from
the Tektronix ftp site through a web browser.
NOTE. To operate the Jitter Analysis Application, the TDS Run-Time Environment
V1.1 or above must be installed on your oscilloscope.
Installing the Application
To install the application from the floppy disk to your oscilloscope, follow these
steps:
1. Power off the oscilloscope.
NOTE. Additional information about the application or installation is located in a
Readme.txt file on the floppy disk. You should insert the floppy disk into a
DOS-based personal computer and read the Readme.txt file before you continue.
If you are updating the application, the Readme.txt file on the Tektronix ftp site
supercedes the Readme.txt file on the floppy disk.
2. Insert the disk in the floppy disk drive and power on the oscilloscope.
NOTE. To verify that the TDS Run-Time Environment V1.1 or above is installed,
watch for the name to appear at the top of the display when you power on the
oscilloscope. If it does not appear, contact your local Tektronix sales office.
After performing the power-up self-test, the oscilloscope automatically
begins the installation procedure.
As the application loads from the disk, the oscilloscope displays a clock icon
to indicate that it is busy. Also, the floppy disk drive LED is on, indicating
activity. If the clock icon continues to display after the floppy disk LED has
gone out, a problem has occurred with the installation. Repeat the above
procedure. If the problem persists, contact your Tektronix representative.
When the installation is complete, an Installation Complete message
displays.
3. Remove the floppy disk and cycle the power to the oscilloscope.
TDSJIT1 Jitter Analysis Application User Manual
3
Installation
Updates Through a Web Browser
If there is an update for this application, it will be available from the Tektronix
ftp site. To install an application update, you will need to download it from the
ftp site to a hard disk, copy it to a blank DOS-formatted floppy disk, and then
install it on your oscilloscope.
NOTE. More information about changes to the application or installation is in a
Readme.txt file on the ftp site. You should read it before you continue.
To copy the application from a web browser, follow these steps:
1. Access the ftp site at ftp://ftp.tek.com/mbd/support/00–index.html#1
2. Scroll through the files to the TDSJIT1 application, select the file, and
download it to your hard disk drive. If necessary, unzip the file.
3. Copy the application from the hard disk to a blank DOS-formatted floppy
disk.
4. Follow the Installing the Application procedure on page 3.
Equipment Under Test Connections
You can use any compatible probe to connect between your EUT (equipment
under test) and the oscilloscope. The connection is usually to a clock signal.
The Skew measurement requires two channels or two reference waveforms.
WARNING. To avoid electric shock, you must ensure that power is removed from
the EUT before attaching a probe to it. Do not touch exposed conductors except
with the properly rated probe tips. Refer to the probe manual for proper use.
Power down the EUT before connecting the probe to it.
.
Table 1 shows the default channel-to-waveform assignments.
T able 1: Channel assignments
Channel or referenceWaveform assignment
Ch 1Main waveform, such as the Clock signal
Ch 2Skewed waveform
Ref1Profile graphical format
Ref2Histogram graphical format
4
TDSJIT1 Jitter Analysis Application User Manual