Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii)
of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1)
and (2) of the Commercial Computer Software -- Restricted Rights clause at FAR 52.227-19, as applicable.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TDSHT3 HDMI Compliance Test Software Online Help
Software Warranty
Tektronix warrants that the media on which this software product is furnished and the encoding of the programs
on the media will be free from defects in materials and workmanship for a period of three (3) months from the
date of shipment. If a medium or encoding proves defective during the warranty period, Tektronix will provide a
replacement in exchange for the defective medium. Except as to the media on which this software product is
furnished, this software product is provided “as is” without warranty of any kind, either express or implied.
Tektronix does not warrant that the functions contained in this software product will meet Customer’s
requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration
of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and
workmanship within a reasonable time thereafter, Customer may terminate the license for this software product
and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS
OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’
RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S PAYMENT IS
THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS
WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER
TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
Table of Contents
About the TDSHT3 HDMI Compliance Test Software............................................................1
Test ...........................................................................................................................................................118
How to…...................................................................................................................................................315
The TDSHT3 HDMI Compliance Test Software is a High Definition Multimedia
Interface (HDMI) compliance test solution. This software helps the test,
validation, and design engineers perform both HDMI physical layer validation
and compliance testing. The TDSHT3 HDMI Compliance Test Software
provides credible test results in conformance with the HDMI standards and test
specifications.
The TDSHT3 HDMI Compliance Test Software offers automated tests for:
Source
Clock-Data Tests: Eye Diagram (Test ID 7-10), Duty Cycle
(Test ID 7-8), Rise Time (Test ID 7-4), Fall Time (Test ID 7-4), Clock
Jitter (Test ID 7-9), Over/Undershoot V-H (Test ID 7-5),
Over/Undershoot V-L (Test ID 7-5), Inter-Pair Skew (Test ID 7-6)
with bold font and title case. For example, Click Open from the shortcut
menu.
tested.
box, which requires input.
* This phone number is toll free in North America. After office hours, please
leave a voice mail message. Outside North America, contact a Tektronix sales
office or distributor; see the Tektronix web site for a list of offices.
TDSHT3 HDMI Compliance Test Software Online Help
3
Introduction
Feedback
Tektronix values your feedback on our products. To help us serve you better,
please send us your suggestions, ideas, or comments on the TDSHT3 HDMI
Compliance Test Software.
Direct your feedback via e-mail to HDMIFeedback@tek.com or FAX at (503) 627-5695 and include the following information. Please be as specific as
possible.
General information
Instrument model number and hardware options, if any
Please indicate if you would like to be contacted by Tektronix about your
suggestions or comments
Program specific information
Software version number
Description of the problem such that technical support can duplicate the
problem
The instrument setup file of the oscilloscope and the application are also
required to identify the problem
If possible, save the waveform on which you are performing the test as a
.wfm file
Note: To know the software version number, click Help > About in the software.
Once you have gathered this information, you can contact technical support by
e-mail. When you use e-mail, be sure to type in the subject line 'TDSHT3 HDMI
Compliance Test Software Problem,' and then attach the .wfm files. You can then
attach the file to your e-mail (depending on the capabilities of your e-mail
editor).
4
TDSHT3 HDMI Compliance Test Software Online Help
Updates through the Web Site
Periodic software upgrades may be available.
To check for upgrades:
Introduction
1. Go to the Tektronix Web site (www.tektronix.com
2. Click Software and Drivers to link to the Software and Firmware Finder
Web page.
3.Enter the product name 'TDSHT3 HDMI Compliance Test Software' to find
available software upgrades.
).
TDSHT3 HDMI Compliance Test Software Online Help
5
Introduction
6
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
Compatibility
The software is compatible with the following oscilloscopes:
Do not change the oscilloscope settings when the test runs. If you change the
settings when the test runs, the software may give abnormal test results.
Prerequisites
TekVisa must be installed on the oscilloscope. If you do not have TekVisa,
you can download it from
http://www.tek.com/site/sw/detail/1,1059,2704,00.html.
If the signal is not connected and the noise level is less than 50 mV, then the
software detects and displays a message such as 'Improper Waveform.'
For better and reliable results
Before you run any test, calibrate the probes and oscilloscope for Signal
Path Compensation.*
8
If the signal is not connected and the noise level is less than 50 mV, then the
software detects and gives a message such as 'Invalid Signal.'
* To calibrate an oscilloscope, on the oscilloscope menu bar, click Utilities >
Instrument Calibration, and then click Calibrate.
TDSHT3 HDMI Compliance Test Software Online Help
Default Layouts and Templates
Templates under C:\TekApplications\TDSHT3\ReportGenerator\Templates
Source Clock-Data Tests
1. Source_Clock_Data_Eye.rgt
2. Source_Clock_Data_Jitter.rgt
3. Source_Clock_Data_Max_Duty_Cycle.rgt
4. Source_Clock_Data_Min_Duty_Cycle.rgt
5. Source_Clock_Data_Clock_Overshoot_VH+.rgt
Getting Started
6. Source_Clock_Data_Clock_Undershoot_VH-.rgt
7. Source_Clock_Data_Data_Overshoot_VH+.rgt
8. Source_Clock_Data_Data_Undershoot_VH-.rgt
9. Source_Clock_Data_Clock_Overshoot_VL-.rgt
10. Source_Clock_Data_Clock_Undershoot_VL+.rgt
11. Source_Clock_Data_Data_Overshoot_VL-.rgt
12. Source_Clock_Data_Data_Undershoot_VL+.rgt
13. Source_Clock_Data_Clock_Rise_Time.rgt
14. Source_Clock_Data_Data_Rise_Time.rgt
15. Source_Clock_Data_Clock_Fall_Time.rgt
16. Source_Clock_Data_Data_Fall_Time.rgt
17. Source_Clock_Data_Inter_Pair_Skew.rgt
Source Data-Data Tests
Source_Data_Data_Inter_Pair_Skew.rgt
Source Single-Ended Tests
1. Source_SingleEnded_Intra_Pair_Skew.rgt
2. Source_SingleEnded_Low_Amplitude+.rgt
3. Source_SingleEnded_Low_Amplitude-.rgt
TDSHT3 HDMI Compliance Test Software Online Help
9
Getting Started
Cable
1. Cable_EyeDiagram_Eye_TP1.rgt
2. Cable_EyeDiagram_Jitter_TP1.rgt
3. Cable_EyeDiagram_Eye_TP2.rgt
4. Cable_EyeDiagram_Jitter_TP2.rgt
Sink Tests
1. Sink_Min_Diff_Sen.rgt
2. Sink_Intra_Pair_Skew.rgt
Default Settings
3. Sink_Jitter_Tol.rgt
Layouts under C:\TekApplications\TDSHT3\ReportGenerator\Layouts
1.Oscilloscope bandwidth is less than 4 GHz. For higher resolution HDMI
signals, you need at least a 4 GHz oscilloscope. Your oscilloscope
bandwidth is less than 4 GHz. You cannot measure less than 1 ns Tbit
signals accurately.
2.Serial Pattern Trigger option is not available. Source Intra-pair skew test
requires serial trigger (Option ST) but it is not found in the oscilloscope.
You cannot perform the Source intra-pair skew test.
TDSHT3 HDMI Compliance Test Software Online Help
13
Getting Started
3.Maximum available record length for two channels is less than 16 M.
For HDMI compliance testing, you need at least 16 M record length in two
channels. This is available with Option 4 M or above, but it is not available
in the installed oscilloscope. The software runs the eye and jitter
measurements with the maximum available record length.
Depending on the type of oscilloscope that you have, you can start the software
in different ways.
Option 1: For supported B-series oscilloscopes
1. On the oscilloscope menu bar, click App > HDMI Compliance Test
Software.
2. A splash screen indicates that the software loading is in progress.
14
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
3.The oscilloscope display resizes to fit in the upper part of the screen. The
lower part of the oscilloscope screen displays the TDSHT3 HDMI
Compliance Test Software.
4. The software is automatically set to its default settings.
5. If you gain access to the oscilloscope functions, then the oscilloscope
display appears full screen and the TDSHT3 HDMI Compliance Test
Software recedes to the background.
6. To return to the TDSHT3 HDMI Compliance Test Software, click App >
Restore Application.
TDSHT3 HDMI Compliance Test Software Online Help
15
Getting Started
Option 2: For supported 7000-series oscilloscopes
1. On the oscilloscope menu bar, click File > Run Application > HDMI
Compliance Test Software.
2. A splash screen indicates that the software loading is in progress.
16
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
3.The oscilloscope display resizes to fit in the upper part of the screen. The
lower part of the oscilloscope screen displays the TDSHT3 HDMI
Compliance Test Software.
4. The software is automatically set to its default settings.
5. If you gain access to the oscilloscope functions, then the oscilloscope
display appears full screen and the TDSHT3 HDMI Compliance Test
Software recedes to the background.
6.To return to the TDSHT3 HDMI Compliance Test Software, click APP on
the top right of the oscilloscope display.
How to Minimize and Maximize the Software
The software appears even when you minimize the oscilloscope display.
To minimize the window, click File > Minimize. The TDSHT3 HDMI
Compliance Test Software window minimizes to the Windows taskbar. The
upper part of the screen has the oscilloscope display and the lower part of
the screen has the desktop.
To restore the minimized window to its previous size, click its taskbar
button.
To hide the window, click Hide on the top-right of the software window.
Note: If you click Hide, the TDSHT3 HDMI Compliance Test Software window
goes to the background and the oscilloscope fills the display.
TDSHT3 HDMI Compliance Test Software Online Help
17
Getting Started
How to Return to the Software
When you gain access to the oscilloscope functions, the oscilloscope fills the
display. You can gain access to the oscilloscope functions in the following ways:
Choose either the menu bar or the toolbar mode on the oscilloscope, and
Click App > Restore Application or click APP on the top right of the
How to Quit the Software
To quit the software:
then gain access to the menus.
oscilloscope display to return to the software.
On the menu bar, click File > Exit.
The Exit dialog box appears.
Click either Yes, No, or Cancel. Yes is selected by default. When the
software runs, it automatically changes some oscilloscope settings. When
you quit the software, you can choose whether to retain these settings or
restore the previous settings.
Note: Using other methods to quit the software may result in an abnormal
termination of the software.
Software Folders and File Names
18
The TDSHT3 HDMI Compliance Test Software uses file name extensions to
identify the file type. The following table lists the default folder names and their
purpose:
Folder Purpose
C:\TekApplications\TDSHT3 This is the software data folder.
C:\TekApplications\TDSHT3\Temp This folder stores the software intermediate files.
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
Shortcut Keys
C:\TekApplications\TDSHT3\Image
s
C:\TekApplications\TDSHT3\Data This folder stores all the software data.
C:\TekApplications\TDSHT3\setup This folder stores all the save and recall files.
C:\TekApplications\TDSHT3\Demo
Tools
C:\TekApplications\TDSHT3\Report
Generator
Menu Shortcut Key
File Alt+F
Tests Alt+T
Results Alt+R
Utilities Alt+U
Help Alt+H
File > Recall Compliance Default Alt+F+D
File > Recall Alt+F+R
This folder stores all the images.
This folder stores the demo waveforms.
This folder stores the report generator files, layouts,
and templates.
File > Recall > First Recent Alt+F+E+1
File > Recall > Second Recent Alt+F+E+2
File > Recall > Third Recent Alt+F+E+3
File > Recall > Fourth Recent Alt+F+E+4
File > Save Alt+F+S
File > Recall Recent Alt+F+E
File > Preferences Alt+F+P
File > Preferences > Position Eye Mask in Center Alt+F+P+M
File > Preferences > Trigger (Rise/Fall Time or Over/Undershoot) > Pulse
Width
File > Preferences > Trigger (Rise/Fall Time or Over/Undershoot) > Edge
Trigger
File > Minimize Alt+F+M
File > Exit Alt+F+X
Tests > Select Alt+T+S
Tests > Select > Source Alt+T+S+S
Alt+F+P+T+W
Alt+F+P+T+E
TDSHT3 HDMI Compliance Test Software Online Help
19
Getting Started
Tests > Select > Sink Alt+T+S+K
Tests > Select > Cable Alt+T+S+C
Tests > Configure Alt+T+C
Tests > Connect Alt+T+N
Tests > View Waveform Alt+T+V
Results > Summary Alt+R+S
Results > Details Alt+R+D
Utilities > Report Generator Alt+U+R
Utilities > Deskew Alt+U+D
Help > Help Topics Alt+H+T
Help > About HDMI Alt+H+A
Error Codes
The following table lists the error codes, their descriptions, and the possible
solutions:
Error
Code
101 Input is 'Not Conn.' Both sources are selected as not
102 Conflict in the selection of inputs. The sources that are selected for the
103 The combination of Ref and Live
Error Message Description Possible Solution
connected.
two inputs (clock source and data
source for differential tests, input 1
and input 2 for single-ended tests)
input signals is not valid.
are the same.
The software supports both Ref or
both Live combinations of channels.
Select valid channels (Ch1-Ch2,
Ref1-Ref2) for at least clock/data
source/data source (differential tests)
or for input1/input2 (single-ended
tests).
Select different channel sources for
input 1 and input 2 for single-ended
tests and different channel sources
for clock source and data source for
differential tests.
Select both ref channels or both live
channels for clock as well as data
source.
20
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
104 Ref Wfm is not valid. The software cannot switch on ref
waveforms. Ref waveforms could be
empty.
110 Unable to acquire waveform. The oscilloscope is not able to
acquire the signal and trigger.
111 Not enough acquisitions to perform
the test.
113 Error in importing the Wfm. The software could not import the
114 Improper Wfm. Signal is not probed at the proper
115 Ref Wfms have different Record
Lengths/Sample Rates.
121 Ref Levels entered are outside the
range of the Wfm.
122 ((Hysteresis Level/2) + Ref Level)
cannot be greater than 100 percent.
123 High Level is less than or equal to
Low Level.
131 Error in calculating Tbit. Not a valid clock waveform. Supply a valid clock waveform and
132 Clock input is required to calculate
Tbit.
152 Select any test to continue. Configure, Connect, View
161 Unable to recover clock. Improper waveform or the software
171 Unable to find edges. The waveform may be noisy or the Check the probes and test fixture
The software expects to acquire a
minimum number of acquisitions that
are configured.
waveform from acquisition. This
happens when there is no valid
waveform in the acquisition memory.
test points.
The ref waveforms have different
sample rates and/or record lengths.
Unable to locate the edges on the
waveform at the transition because
the levels configured do not fall
within the transition of the waveform.
((Hysteresis Level/2) + Ref Level)
has to be within 100 percent for edge
finding.
The configured high level value is
less than the low level value.
The Tbit value has to be calculated
before you run a test that uses only
data source(s).
Waveform, and Run Test need at
least one test to be selected.
components are missing.
Recall the required ref waveform
from the appropriate file on the
oscilloscope.
Ensure that the software
configurations are proper. Check the
probes and test fixture connections.
If the test uses serial trigger, ensure
that the CTL pattern is present on
the waveform.
Ensure that the software
configurations are proper. Check the
probes and test fixture connections.
Check the probes and test fixture
connections. Run the test again.
Refer to the connections diagram
and probe the proper signal.
Use waveforms that are acquired
simultaneously for ref waveforms.
Enter the Ref Level voltage value
where the transition occurs on the
waveform. Enter 50 percent of the
level of the peak to peak transition
level for mid ref levels, 80 percent of
the peak to peak for high ref levels,
and 20 percent of the peak to peak
for low ref levels.
Set both the ref and (Hysteresis
Level/2) to be less than 100 percent.
Configure the high level to be greater
than the low level.
run the test again.
Select and run a test that uses clock
source for Tbit value. Click Connect,
select clock source, and then click
Re-calculate Tbit before you run the
test.
Select at least one test before you
click either Configure, Connect, View Waveform, or Run Test.
Supply the proper waveform.
Reinstall the software.
TDSHT3 HDMI Compliance Test Software Online Help
21
Getting Started
hysteresis level may be low. connections. Increase the hysteresis
band level.
172 Not enough edges. Number of edges found on the
waveform is less than the minimum
number of edges that is required for
the test.
173 Unable to calculate skew. Could not find the mid of the
waveform.
174 CTL pattern not found. The CTL pattern 0010101011
0010101011 0010101011 was not
found on the waveform.
175 Option ST is not installed on the
oscilloscope.
177 Unable to find
overshoot/undershoot.
178 Unable to calculate Vswing. Signal is not probed at the proper
181 Check the DTG connection. DTG connection has failed. This
182 File not found in the DTG. The configured file is not found in the
183 Invalid logical channel. The logical channel is invalid. Provide a proper logical channel.
Option ST is not available on the
oscilloscope.
Signal is not probed at the proper
test points.
test points.
could happen if:
The DTG is not switched on.
There is a mismatch in the GPIB-
ENET configuration, software GPIB
configuration, or DTG remote control
configuration.
The GPIB cable is not connected
properly.
DTG.
Decrease the horizontal scale to
have more complete cycles of the
waveform. Adjust the hysteresis level
of the signal to find the edge at the
required level.
Check the probes and test fixture
connections.
Ensure that the appropriate pattern
is present on the source waveform.
Change the polarity of the waveform.
Install Option ST.
Follow the instructions in the setup
diagram and probe the proper signal.
Follow the instructions in the setup
diagram and probe the proper signal.
Switch on the DTG and wait for the
DTG software to load.
Check GPIB connections.
Ensure that the primary and
secondary addresses of DTG in the
remote control match the GPIBENET configuration of the
oscilloscope.
Ensure that the GPIB-ENET
configuration on your oscilloscope
matches the signal sources
configuration in the software.
Ensure that the specified file in the
software is present in the DTG.
Specify a file name that is present in
the DTG.
22
TDSHT3 HDMI Compliance Test Software Online Help
Getting Started
184 Conflict in selection of outputs from
the DTG.
191 Check the AWG connection. AWG connection has failed. This
192 File not found in the AWG. File is not present in the AWG. Ensure that the required file is
The same physical channel (A1, A2,
B1, B2, C1, C2, D1, D2) is selected
for any two logical channels (Clock,
Data0, Data1, Data2).
could happen if the AWG is not
switched on, there is a mismatch in
the GPIB-ENET configuration,
application GPIB configuration, and
AWG remote control configuration, or
if the GPIB cable is not connected
properly.
Select different physical channels
(A1, A2, B1, B2, C1, C2, D1, D2) for
a given logical channel (Clock,
Data0, Data1, Data2).
Switch on the AWG and wait for the
AWG software to load. Check GPIB
connections. Ensure that the primary
address of AWG in the Utility > Network > Address matches with
the GPIB-ENET configuration of the
oscilloscope. Ensure that the GPIBENET configuration on your
oscilloscope matches the signal
sources configuration in the
software.
present in the AWG.
TDSHT3 HDMI Compliance Test Software Online Help
23
Getting Started
193 Check the Signal Sources
connection.
194 Jitter value is unavailable. Signal is not probed at the proper
201 Edges on the Wfm are lesser than
the configured number of edges.
202 Calculated skew is greater than the
oscilloscope skew range.
203 Cycle has less than 20 sample
points.
Signal sources connection has failed.
It may be due to DTG or AWG
connection failure. DTG connection
has failed. This could happen if:
The DTG is not switched on
There is a mismatch in the GPIB-
ENET configuration, software GPIB
configuration, and DTG remote
control configuration
If the GPIB cable is not connected
properly.
AWG connection has failed. This
could happen if:
The AWG is not switched on
There is a mismatch in the GPIB-
ENET configuration, software GPIB
configuration, and AWG remote
control configuration
If the GPIB cable is not connected
properly
Primary addresses of DTG and AWG
are same.
test points.
Deskew number of edges set by the
user to perform the deskew is not
available on the waveform.
The calculated skew value is greater
than the oscilloscope deskew range.
Insufficient number of samples in a
complete cycle. The number of data
points in the identified cycle is less
than 20 data points.
For DTG connection failure:
Switch on the DTG and wait for the
DTG software to load. Check the
GPIB connections. Ensure that the
primary address of DTG in the
remote control matches the GPIBENET configuration of the
oscilloscope. Ensure that the GPIBENET configuration on your
oscilloscope matches the signal
sources configuration in the
software.
For AWG connection failure:
Switch on the AWG and wait for the
AWG software to load. Check the
GPIB connections. Ensure that the
primary address of AWG in the
Utility > Network > Address
matches with the GPIB-ENET
configuration of the oscilloscope.
Ensure that the GPIB-ENET
configuration on your oscilloscope
and signal sources configuration
in the software match.
Select distinct primary addresses for
DTG and AWG.
Follow the instructions in the setup
diagram and probe the proper signal.
Ensure that the edges in the
waveform and the display in the
numeric input are the same. Adjust
the horizontal scale to increase the
number of transition that is required
to adjust the deskew.
The deskew will be done to the
maximum deskew value that is
applicable to the oscilloscope.
Increase the sampling rate.
24