Tektronix TDSDVI DATASHEET

DVI Compliance Test Solution
TDSDVI Data Sheet
Features & Benets
Wide Range of Tests enable Complete Validation to Standards
Automatic One-button Testing ensures Faster Testing with Higher
y
Reliabilit
Comprehensive Range of Tests for Transmitter, Cable, and Receiver Testing – Eye-diagram Test, Peak-to-Peak Jitter, Inter-pair and Intra-pair Skew, Rise and Fall Time.
Automatic Pass/Fail Notication for Quick Conformance to Standards
Supports All Resolutions up to UXGA
Half-clock and Pseudorandom Patterns for Various Resolutions allow Testing as per DDWG Procedures
Online Con
Sophisticated Report Generator Saves Time
Unique Res Conducted on Two Different Devices
text-sensitive Help provides Assistance
ult-comparison Feature enables Comparing Results of Tests
Applications
DVI Physi
Characterize the Quality of Your DVI Designs
cal Layer Compliance Testing
Data Sheet
indication for the conducted tests, substantiated with detailed results, makes TDSDVI the preferred solution for DVI compliance testing. An automatic report generat
or provides the detailed report for the conducted tests.
Characteristics
Eye diagram showing mask hits.
Engineers involved in d esign, characterization, and validation of DVI devices face constant pressure to speed new products to the marketplace. Developer
s need to improve efciency with faster validation cycles. Design and validation engineers need to ols to perform quick and r eliable compliance testing right on their bench.
TDSDVI Compliance Test Solution, coupled with DPO7354 and DPO/DSA/MSO70000 Series oscilloscopes, enhances test efciency with faster validation cycles and offers higher reliability for conformance to standards.
Comprehensive Range of Measureme nts
TDSDVI addresses the wide spectrum of Transmitter, Receiver, and Cable tests. The portfolio of tests includes eye diagram, jitter, skew, and rise/fall time testing.
Reliable Testing with In-depth Information
TDSDVI i according to DVI specication and the DVI Test and Measurement Guide. It rst calculates the unit interval (T and performs the eye diagram test on the worst-case eye amon g the ten bits of a pixel. The mask hit count provides detailed information about the signal characteristics.
s the industry’s rst c ompliance test tool that conducts testing
), accumulates a million acquisitions,
bit
Easy to Use
TDSDVI automatically sets up the oscilloscope for the selected test, creates the eye mask, and also performs other parametric tests. Pass/Fail
Characteristic
Transmitter Tests
Cable Tests Eye Diagram (high amplitude and low amplitude),
Receiver Tests Patterns for Compliance
Testing as per DDWG Procedures
Description
Eye Diagram, Peak-to-Peak Jitter, Skew (Intra- and Inter-pair), Rise/Fall Time
Peak-to-Peak Jitter, Skew (Intra- and Inter-pair) Eye Diagram (high amplitude and low amplitude) Half-clock and pseudorandom patterns for resolutions
from VGA to UXGA.
Tektronix Oscilloscopes Required
DPO7000 and
3.0.0 and above.
DPO/DSA/MSO70000 Series oscilloscopes with rmware version
Ordering Information
TDSDVI
DVI Compliance Test Software
Includes: Application CD and electronic documentation.
To O rder Al Series Oscilloscopes
Opt. DVI – DVI Compliance Test Solution.
To Upgrade Existing Oscilloscope
Model
DPO/DSA/MSO70000 Series
DPO7354 DPO-UP DVI
Recommen
Accessory Description
Differential Probes DPOJET Single-ended Probes Arbitrary Waveform
Generator Time Domain
Reectometery
ong with the DPO7354 and DPO/DSA/MSO70000
Order
DPO-UP DVI
ded Accessories
P7350, P7330, P6330 Jitter and Eye Analysis package P7240 AWG5000 and AWG7000 Series
0and80E04
DSA820
2 www.tektronix.com
Loading...
+ 2 hidden pages