Tektronix TDSCEM1 User Manual

User Manual
TDSCEM1 Communications Eye-Diagram Measurements Application
071-0606-00
This document supports software version 1.0.0 and above.
Warning
Copyright © T ektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in T echnical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the Commercial Computer Software – Restricted Rights clause at F AR 52.227-19, as applicable.
T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A. T ektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000 TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.
WARRANTY
T ektronix warrants that the media on which this software product is furnished and the encoding of the programs on the media will be free from defects in materials and workmanship for a period of three (3) months from the date of shipment. If a medium or encoding proves defective during the warranty period, T ektronix will provide a replacement in exchange for the defective medium. Except as to the media on which this software product is furnished, this software product is provided “as is” without warranty of any kind, either express or implied. T ektronix does not warrant that the functions contained in this software product will meet Customer’s requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If T ektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S PAYMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT , SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

Getting Started
Operating Basics
Related Documentation vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventions vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contacting T ektronix viii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Description 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compatibility 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requirements and Restrictions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Updates Through a Web Browser 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Application 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to a System Under T est 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Basics 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Menu Structure 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main and Side Menus 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Common Menu Items 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Utility Menus 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Basic Oscilloscope Functions 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Local Help 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Returning to the Application 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W arning Messages 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the Display 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up the Application 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Menu 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measurement Setup 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measurement Options 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display Results Setup 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T aking Measurements 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving the Results to a Data Log File 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Importing a Data Log File into a Personal Computer 12. . . . . . . . . . . . . . . . . . . . .
Viewing Data 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving and Recalling Setups 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving a Setup 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recalling a Setup 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exiting the Application 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tutorial 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to a Communications Signal 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up the Oscilloscope 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Starting the Application 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T aking Measurements 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving the Results to a Data Log File 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viewing the Results.csv File (Data Log) 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
i
Table of Contents
Reference
Appendices
Stopping the Tutorial 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Returning to the Tutorial 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIB Program Example 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Structure 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parameters Reference 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Menu 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measure Menu 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measure Options Menu 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logging Menu 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Menu 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Utility Menu 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix A: Measurement Algorithms 39. . . . . . . . . . . . . . . . . . . . . . . .
Oscilloscope Setup Guidelines 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T est Methodology 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measurements 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B: GPIB Command Syntax 43. . . . . . . . . . . . . . . . . . . . . . . . . .
VARIABLE:VALUE TDS COMMAND 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Syntax 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Arguments and Returns 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index
ii
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual

List of Figures

Table of Contents
Figure 1: TDSCEM1 Communication Eye-Diagram Measurements
Application 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2: Connecting to the SUT 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3: Returning to the application 7. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4: Example of a mask pattern with an eye-diagram, the Results
readout and a .csv file (data log) 13. . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 5: Starting the application 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6: TDSCEM1 application initial display 19. . . . . . . . . . . . . . . . . .
Figure 7: OC1/STM0 standard mask pattern selected 20. . . . . . . . . . . .
Figure 8: An OC1/STM0 eye-diagram, and Results readout 21. . . . . . .
Figure 9: Measure menu, page 1 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10: Measure menu, page 2 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 11: Measure menu, page 3 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 12: Measure menu, page 4 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 13: Results readout for all measurements 23. . . . . . . . . . . . . . . . .
Figure 14: Logging setup menu 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 15: Path to the RESULTS.CSV file 25. . . . . . . . . . . . . . . . . . . . . .
Figure 16: Copying the RESULTS.CSV file to a floppy disk 25. . . . . . .
Figure 17: Data in a Results.csv file viewed in a spreadsheet
program 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 18: Application-specific menu structure 33. . . . . . . . . . . . . . . . . .
Figure 19: Control and Utility menu structures 34. . . . . . . . . . . . . . . . . .
Figure 20: Eye-diagram and mask pattern values 40. . . . . . . . . . . . . . . .
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
iii
Table of Contents

List of Tables

Table 1: Common menu items 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2: Utility menus 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3: Display options 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4: Mask pattern selections and communications standard
documents 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5: Measurements 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6: Measurement Options 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7: Control menu items 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8: Logging menu selections 12. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9: Measure menu parameters 35. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10: Measure Options menu parameters 36. . . . . . . . . . . . . . . . . . .
Table 11: Logging menu parameters 36. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 12: Control menu parameters 37. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 13: Utility menus and parameters 37. . . . . . . . . . . . . . . . . . . . . . .
Table 14: Measurements and calculations 41. . . . . . . . . . . . . . . . . . . . . .
Table 15: VARIABLE:VALUE TDS COMMAND arguments and
queries 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 16: Measurement results queries 46. . . . . . . . . . . . . . . . . . . . . . . .
iv
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.
Connect and Disconnect Properly . Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Symbols and Terms
T erms in this Manual. This term may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
v
General Safety Summary
vi
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual

Preface

This manual contains operating information for the TDSCEM1 Communication Eye-Diagram Measurements Application. The manual consists of the following chapters:
H The chapter Getting Started briefly describes the TDSCEM1 Communication
Eye-Diagram Measurements Application, lists oscilloscope compatibility, and provides installation instructions.
H The chapter Operating Basics covers basic operating principles of the
application and includes a tutorial that teaches you how to set up the application to acquire a waveform, take measurements, and view the results.
To show you how to operate the application using GPIB commands, this chapter includes a simple GPIB program.
H The chapter Reference includes a diagram of the menu structure and
descriptions of parameters.
H The appendix Measurement Algorithms contains information on measure-
ment guidelines and on how the application takes the measurements.

Related Documentation

Conventions

H The appendix GPIB Command Syntax contains a list of arguments and values
that you can use with the GPIB commands and their associated parameters.
The user manual for your oscilloscope provides general information on how to operate the oscilloscope.
This manual uses the following conventions: H This manual refers to the TDSCEM1 Communication Eye-Diagram
Measurements Application as the TDSCEM1 application or as the applica­tion.
H When steps require that you make a sequence of selections using front-panel
controls and menu buttons, an arrow ( front panel button and a menu, or between menus. Names that are for a main menu or side menu item are clearly indicated: Press VERTICAL MENU Coupling (main) DC (side) Bandwidth (main) 250 MHz (side).
) marks each transition between a
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
vii
Preface

Contacting Tektronix

Product Support
Service Support
For other information
To write us Tektronix, Inc.
For application-oriented questions about a Tektronix measure­ment product, call toll free in North America: 1-800-TEK-WIDE (1-800-835-9433 ext. 2400) 6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail: tm_app_supp@tek.com
For product support outside of North America, contact your local Tektronix distributor or sales office.
Contact your local Tektronix distributor or sales office. Or visit our web site for a listing of worldwide service locations.
http://www.tektronix.com In North America:
1-800-TEK-WIDE (1-800-835-9433) An operator will direct your call.
P.O. Box 1000 Wilsonville, OR 97070-1000
viii
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
Getting Started

Product Description

The TDSCEM1 Communication Eye-Diagram Measurements Application is a Java-based application that enhances basic capabilities of TDS oscilloscopes.
The application displays a mask pattern behind the eye-diagram of the commu­nication signal being acquired. This allows you to visually analyze the eye-dia­gram against the mask pattern. In addition, the application can display other measurements in a numeric format, as well as saving the information to a data log file to view on a personal computer.
Figure 1 shows an example of a standard mask pattern, the eye-diagram of an OC1/STM0 communications signal, and the Results readout.
Figure 1: TDSCEM1 Communication Eye-Diagram Measurements Application

Compatibility

The Communication Eye-Diagram Measurements Application is compatible with the following Tektronix oscilloscopes:
H All TDS 500D and 700D Digital Phosphor Oscilloscopes with Option 2C
(Communications Signal Analyzer package) and Option HD (hard disk drive) or Option 2M (hard disk drive plus 8 MB record length); the TDS oscilloscope must also have firmware version 6.4e and up
H TDS 700C Color Digitizing Oscilloscopes with Option 2C (Communica-
tions Signal Analyzer package) and Option HD (hard disk drive) or Option 2M (hard disk drive plus 8 MB record length); the TDS oscilloscope must also be serial number B020100 and up, with firmware version 6.4e and up
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
1
Product Description
You can also use this application with Tektronix TDS Option 3C (Short-wave­length Fibre Channel Optical Reference Receiver) or TDS Option 4C (Long­wavelength SONET/SDH Optical Reference Receiver).
For a current list of compatible oscilloscopes, check the Tektronix, Inc. web site, http://www.tektronix.com/Measurement/scopes/index.html in the Software and Drivers category.

Requirements and Restrictions

The TDS Run-Time Environment V1.1.0 and above must be installed on the oscilloscope to operate the TDSCEM1 application.
The TDS Run-Time Environment V1.2.0 and above must be installed on the oscilloscope to use the GPIB commands.

Updates Through a Web Browser

You can find information about this and other applications at the Tektronix, Inc. web site, http://www.tektronix.com/Measurement/scopes/index.html in the Software and Drivers category. Check this site for application updates that you can download and for free applications.
To install an application update, you will need to download it from the Tektronix ftp site to a hard disk, copy it to a blank DOS-formatted floppy disk, and then install it on your oscilloscope.
NOTE. More information about changes to the application or installation is in a Readme.txt file on the ftp site. You should read it before you continue.
To copy the application from a web browser, follow these steps:
1. Access the ftp site at ftp://ftp.tek.com/mbd/support/00–index.html#1.
2. Scroll through the files to the TDSCEM1 application, select the file, and
download it to your hard disk drive. If necessary, unzip the file.
3. Copy the application from the hard disk to a blank, DOS-formatted floppy
disk.
4. Follow the Installing the Application procedure on page 3.

Accessories

2
There are no standard accessories for this product.
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual

Installation

The TDSCEM1 floppy disk contains the Communication Eye-Diagram Measure­ments Application. You can download updates, if any, from the Tektronix ftp site through a web browser.
NOTE. To operate the TDSCEM1 application, the TDS Run-Time Environment V1.1.0 or above must be installed on your oscilloscope. To use GPIB commands, the TDS Run-Time Environment V1.2.0 or above must be installed.

Installing the Application

To install the application from the floppy disk to your oscilloscope, follow these steps:
1. Power off the oscilloscope.
NOTE. Additional information about the application or installation is located in a
Readme.txt file on the floppy disk. You should insert the floppy disk into a DOS-based personal computer and read the Readme.txt file before you continue.
If you are updating the application, the Readme.txt file on the Tektronix ftp site supercedes the Readme.txt file on the TDSCEM1 floppy disk.
2. Insert the disk in the floppy disk drive and power on the oscilloscope.
NOTE. To verify that the TDS Run-Time Environment V1.1 or above is installed, watch for the name to appear at the top of the display when you power on the oscilloscope. If it does not appear, contact your local Tektronix sales office.
After performing the power-up selftest, the oscilloscope automatically begins the installation procedure.
As the application loads from the disk, the oscilloscope displays a clock icon to indicate that it is busy. Also, the floppy disk drive LED is on, indicating activity. If the clock icon continues to display after the floppy disk LED has gone out, a problem has occurred with the installation. Repeat the above procedure. If the problem persists, contact your Tektronix representative.
When the installation is complete, an Installation Complete message displays.
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
3
Installation
3. Remove the floppy disk and cycle the power to the oscilloscope.

Connecting to a System Under Test

You can use a P6701B or P6703B optical receiver probe to connect between your System Under Test (SUT) and the oscilloscope.
To connect the probe between the SUT and oscilloscope, refer to Figure 2 and follow these steps:
WARNING. To avoid electric shock, you must ensure that power is removed from the SUT before attaching a probe to it. Do not touch exposed conductors except with the properly rated probe tips. Refer to the probe manual for proper use.
1. Power down the SUT.
2. Connect the optical receiver probe to CH 1 of the oscilloscope.
3. Press VERTICAL MENU Probe Functions (main) Cal Probe (side).
This removes the dark level (Pdark) from the signal which allows the cursors
to read the true signal power levels.
4. Connect the optical receiver probe to a communication signal in the SUT.
TDS Oscilloscope
SUT
Optical cable
CH1
P6701B or P6703B O/E converter probe
Optical cable
Optical attenuator
Figure 2: Connecting to the SUT
4
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
Operating Basics

Operating Basics

This section contains information on the following topics and tasks:
H Application menu structure H Using basic oscilloscope functions H Warning messages H Configuring the display H Setting up the application H Taking measurements H Storing the results to a data log file H Importing the data log file into a personal computer H Viewing the results H Saving and recalling setups H Exiting the application

Application Menu Structure

There are two types of menus in the application menu structure: main menus and side menus. Some side menus contain common menu items as shown in Table 1.
Main and Side Menus
The main menu names appear in the bottom of the display and the side menu names appear on the right side of the display. To see the complete application menu structure, refer to Figure 18 on page 33.
When you press the front-panel button associated with a main menu, the side menu changes. In many cases, when you press a side menu, new side menu items appear. As an example, the next figure shows you how to access the Help selections through the main Utility menu and the Help side menu.
Main menu Side menu Side menu item
Utility
Help
First Page Next page Previous page Last Page Quit Help
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
5
Operating Basics
Common Menu Items
Utility Menus
Table 1 lists common side menu items.
T able 1: Common menu items
Menu item Description
Cancel Cancels the message being displayed Done Indicates that you are through making changes to that set of side menus. The
application returns to the previous menu
OK Confirms the action
Table 2 lists the Utility menus.
T able 2: Utility menus
Utility name Description
Help Accesses the online help information and views various pages Exit Exits the application Save/Recall Setup Accesses the save and the recall menus for application setups Display Options Accesses other menus where you can change display settings, such as
the message box location on the display

Using Basic Oscilloscope Functions

You can use the Utility menu to access help information about the application. You can also use other oscilloscope functions and easily return to the application.
Using Local Help
The application includes local help information about the measurements modes, with some explanation of the individual controls.
To display the local help, follow these steps:
1. Press Utility (main) Help (side).
2. Use the side menu buttons to navigate through the help.
6
TDSCEM1 Communication Eye-Diagram Measurements Application User Manual
Loading...