Tektronix TDS3SDI User Manual

User Manual
TDS3SDI 601 Digital Video Application Module
071-0787-00
*P071078700*
Copyright E Tektronix, Inc. All rights reserved.

WARRANTY SUMMARY

Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment from an authorized Tektronix distributor. If a product or CRT proves defective within the respective period, Tektronix will provide repair or replacement as described in the complete warranty statement.
To arrange for service or obtain a copy of the complete warranty statement, please contact your nearest Tektronix sales and service office.
EXCEPT AS PROVIDED IN THIS SUMMARY OR THE APPLICABLE WARRANTY STATEMENT, TEKTRONIX MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL TEKTRONIX BE LIABLE FOR INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500 Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
www.tektronix.com
1

Contents

Installation 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The 601 Digital Video Module 13. . . . . . . . . . . . . . . . . .
601 Digital Video Conventions 14. . . . . . . . . . . . . . . . . .
Accessing 601 Digital Video Functions 15. . . . . . . . . . .
Menu Changes 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alternating Trigger Source 36. . . . . . . . . . . . . . . . . . . .
Specifications 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Manual Storage

The oscilloscope front cover has a convenient place to store this manual.

Contacting Tektronix

Product Support
For questions about using Tektronix measurement products, call toll free in North America: 1-800-833-9200 6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail: support@tektronix.com
Service Support
Toll-free Number
Postal Address
Web Site
For product support outside of North America, contact your local Tektronix distributor or sales office.
T ektronix offers a range of services, including Extended Warranty Repair and Calibration services. Contact your local Tektronix distributor or sales office for details.
For a listing of worldwide service centers, visit our web site.
In North America: 1-800-833-9200 An operator can direct your call.
Tektronix, Inc. Department or name (if known) P.O. Box 500 Beaverton, OR 97077 USA
www.tektronix.com
3

Preventing Electrostatic Damage

CAUTION. Electrostatic discharge (ESD) can
damage components in the oscilloscope and its accessories. To prevent ESD, observe these precautions when directed to do so.
Use a Ground Strap. W ear a grounded antistatic wrist strap to
discharge the static voltage from your body while instal­ling or removing sensitive components.
Use a Safe Work Area. Do not use any devices capable of
generating or holding a static charge in the work area where you install or remove sensitive components. Avoid han­dling sensitive components in areas that have a floor or benchtop surface capable of generating a static charge.
Handle Components Carefully. Do not slide sensitive compo-
nents over any surface. Do not touch exposed connector pins. Handle sensitive components as little as possible.
Transport and Store Carefully . Transport and store sensitive
components in a static-protected bag or container.

Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.

To Avoid Fire or Personal Injury

Do Not Operate With Suspected Failures. If you suspect there
is damage to this product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry.

Safety terms in this manual

CAUTION. These statements identify conditions
or practices that could result in damage to the equipment or other property.
2
5
4. Power on the oscilloscope. The oscilloscope checks
whether or not the firmware update is necessary. If an update is necessary, go to page 5. If an update is not necessary, go to page 7.

Firmware Update Required.

If a firmware update is necessary, the oscilloscope displays the following message:
This procedure will replace the firmware in the instrument with firmware from the floppy disk. This procedure will take approximately 5 minutes.
Caution: Do not turn the instrument off or eject the floppy disk until prompted.
Push ‘OK Load New Firmware’ to proceed. Push MENU OFF to abort this procedure.
1. Push OK Load New Firmware to begin loading the
firmware. The oscilloscope shows a clock icon on the screen while the firmware upgrade is in process. If a second firmware floppy disk is required, the oscilloscope will instruct you to eject the first disk and insert the second disk.
If you do not want to upgrade the firmware, push MENU OFF.
When the firmware upgrade is complete, the oscillo­scope will restart automatically with the new firm­ware.

Installation

This section describes how to install and check the TDS3SDI 601 Digital Video application firmware and module.

Installing the Application Module Firmware

NOTE. You must install the application module
firmware the first time you install a new application module. If you do not install the firmware, the new application module may not function at all, or may not function correctly. It is strongly recommended that you install new firmware when the oscilloscope indicates that an update is necessary.
To install the application module firmware, do these steps:
1. Save any oscilloscope settings and/or reference
waveforms to floppy disk before doing these steps.
2. Power off the oscilloscope.
3. If the application module came with one or more
floppy disks, insert floppy disk 1 into the floppy disk drive.
4
7
4. Proceed to step 1 of Firmware Update Not Necessary
on page 7 to finish the firmware installation.

Firmware Update Not Required.

If a firmware update is not necessary, the oscilloscope displays the following message:
A floppy disk containing instrument firmware has been detected. However, the firmware on the disk is not newer than the instrument firmware. Therefore, no firmware upgrade is required.
Push MENU OFF to remove this message.
1. Push the MENU OFF button.
2. Eject the floppy disk.
3. You are done installing the firmware. Go to Installing
the Application Module on page 8.
NOTE. If you power off the oscilloscope, eject the
floppy disk before prompted, or if there is a power outage during the firmware upgrade process, you must restart the firmware upgrade procedure starting at step 2 on page 4.
2. The oscilloscope may also display the following
message:
WARNING! This instrument is not calibrated. You must run Signal Path Compensation (SPC) in order to calibrate the instrument.
SPC is adversely affected by input signals with AC components. Disconnect or otherwise remove these signals prior to running SPC. SPC will take approximately 10 minutes to run.
Push OK Compensate Signal Paths to begin the calibration procedure. Or, you may run SPC in the UTILITY Cal menu.
3. If the instrument has been operating for 20 minutes or
longer in the ambient temperature at which it will be used, Push OK Compensate Signal Paths to run SPC. You can also skip this step for now and run SPC at a later time.
6
9
ITU-R 601

Installing the Application Module

The following figures show how to install the TDS3SDI application module.
CAUTION. Turn off power before installing or
removing a module. To avoid damaging the oscilloscope or application module, observe the ESD precautions described on page 3.
8
Loading...
+ 15 hidden pages