Tektronix TCPA300, TCPA400, TCP303, TCP305A, TCP312A Safety Instructions

...
xx
TCPA300/400 Ampliers and
ZZZ
TCP303/305A/312A/404XL Current Probes
Compliance and Safety Instructions
www.tek.com
P071364300*
*
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worldwide, visit www.tek.com to nd contacts in your area.
Table of Contents
Important safety information ........................... .................................. ......................... 1
General safety summary ...................................................................................... 1
Service safety summary.. .................................. ................................ ................... 4
Terms in t hi
Symbols and terms on the product........................................................................... 5
Compliance information ........................................................................................... 6
EMC compliance (TCPA300/400 only)...... ................................ ............................... 6
Safety compliance ............................................................................................. 7
Environmental considerations ................................................................................ 9
Operati
Installation.......................................................................................................... 12
Operate the amplier.................. .................................. ................................ .......... 17
Operate the current probe......................................................................................... 20
ng considerations ......................................................................................... 10
Standard accessories.................. ................................ .................................. ...... 12
Optional accessories .......................... ................................ ................................ 13
System conguration ............................. ................................ ............................ 13
Connect the amplier to an oscilloscope . ..... . ..... . ..... . ..... . ..... . ..... . ..... . ... . . . .... . . .... . . .... . . 14
Powe
Connect the probe to the amplier ................................ ................................ .......... 16
LED indicators .................... .................................. ................................ .......... 18
Overload conditions .... . ..... . ..... . ..... . ..... . ..... . ..... . ..... . ..... . ..... . ..... .... . . ..... . ..... . ..... . .. 19
sic operation................................................................................................ 20
Ba
Operate the current probe slide.............................................................................. 21
Degauss and autobalance the current probe.......................................... ...................... 24
Use the ground lead........................................................................................... 25
Make DC current measurements............................................................................ 26
Make AC current measurements............................................................................ 28
s manual ... ................................ ................................ ....................... 4
r on the amplier ....................................................................................... 15
Ampliers and Current Probes Compliance and Safety Instructions i
Table of Contents
ii Ampliers and Current Probes Compliance and Safety Instructions
Important safety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition.
To safely perform service on this product, additional information is provided at the end of this section. (See page 4, Service safety summary.)
General safety summary
Use the product only as specied. Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
TCPA300/400 only: This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety precautions specied in this manual.
The product is designed to be used by trained personnel only.
Only qualied personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.
To avoid re or
personal injury
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
Use proper power cord. TCPA300/400 only: Use only the power cord specied for this product and certied for the country of use.
Do not use the provided power cord for other products.
Ground the product. TCPA300/400 only: This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, make sure that the p roduct is properly grounded.
Ampliers and Current Probes Compliance and Safety Instructions 1
Important safety information
Power disconne
ct. TCPA300/400 only: The power cord disconnects the product
from the power source. See instructions for the location. Do not position the equipment so that it is difcult to operate the power cord; it must remain accessible to the user at all times to allow for quick disconnection if needed.
Connect and disconnect properly. TCPA300/400 only: Do not connect or disconnect
probes or test leads while they are connected to the circuit.
Use only current probes, test leads, and adapters supplied with the product, or indicated
by Tektronix to be suitable for the product.
Observe all terminal ratings. TCPA300/400 only: To avoid re or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
Do not apply a potential to a ny terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not o
perate without covers. Do not operate this product with covers or panels
removed, or with the case open. Hazardous voltage exposure is possible.
Avoid exposed circuitry. Do not touch exposed connections and components when powe r is present.
t operate with suspected failures. TCPA300/400 only: If you suspect that
Do no
there is damage to this product, have it inspected by qualied service personnel.
able the product if it is damaged. Do not use the product if it is damaged
Dis or operates incorrectly. If in doubt about safety of the product, turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect current probes, test leads, and accessories for mechanical damage and replace when damaged. Do not use probes or test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specied replacement parts.
Do not operate in wet/damp conditions. Be aware that condensation may occur if a unit is moved from a cold to a warm environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry. Remove the input signals before you clean
the product.
2Amplifiers and Current Probes Compliance and Safety Instructions
Important safety information
Probes and test leads
Provide proper
ventilation. TCPA300/400 only: Refer to the installation
instructions in the manual for details on installing the product so it has proper ventilation.
Slots and openings are provided for ventilation and should never be covered or otherwise obstructed. Do not push objects into any of the openings.
Before conn
ecting probes or test leads to the TCPA300/400, connect the power
cord from the power connector to a properly grounded power outlet.
Keep nger
s behind the protective barrier, protective nger guard, or tactile
indicator on the probes.
Remove al
l probes, test leads and accessories that are not in use.
Use only correct Measurement Category (CAT), voltage, temperature, altitude, and ampe
rage rated probes, test leads, and adapters for any measurement.
Beware of high voltages. Understand the voltage and current ratings for the probe you are using and do not exceed those ratings.
The v oltage rating for the TCPA300/400 depends on the probe and your application. Refer to the Specications section of the manual for more information.
ect and disconnect properly. TCP303/305A/312A/404XL only: Connect
Conn
the probe output to the measurement product before connecting the probe to the circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement product.
Connect and disconnect properly. De-energize the circuit under test before connecting or disconnecting the current probe.
TCPA300/400 only: Connect the probe reference lead to earth ground only.
Do not connect a current probe to any wire that carries voltages or frequencies above the current probe voltage rating.
Inspect the probe and accessories. Before each use, inspect probe and accessories for damage (cuts, tears, or defects in the probe body, accessories, or cable jacket). Disable and do not use the current probe if it is damaged. Do not use the product if it is damaged or operates incorrectly.
Examine the exterior of the current probe before you use it. Look for cracks or missing pieces.
Use only specied replacement parts.
Ampliers and Current Probes Compliance and Safety Instructions 3
Important safety information
Service safet
ysummary
The Service safety summary section contains additional information required to safely perform service on the product. Only qualied personnel should perform service proc summary before performing any service procedures.
To avoid electric shock. Do not touch exposed connections.
Do not service alone. Do not perform internal service or adjustments of this
product un present.
Disconnect power. To avoid electric shock, switch off the product power and disconnect the power cord from the mains power before removing any covers or panels, or opening the case for servicing.
Use care when servicing with power on. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
Verify safety after repair. Always recheck ground continuity and mains dielectric stre
edures. Read this Service safety summary and the General safety
less another person capable of rendering rst aid and resuscitation is
ngth after performing a repair.
Termsinthismanual
se terms may appear in this manual:
The
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
4Amplifiers and Current Probes Compliance and Safety Instructions
Important safety information
Symbols and te
Ampliers
rms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
When this symbol is marked on the product, be sure to consult the manual to nd out the nature of the potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used to refer the user to ratings in the manual.)
The following symbol(s) may appear on the TCPA300/400 ampliers:
Probes
The following symbol(s) may appear on the TCP303/305A/312A/404XL current probes:
Ampliers and Current Probes Compliance and Safety Instructions 5
Compliance information
Compliance in
formation
This section
lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument complies. This product is intended for use by professionals and trained personnel only; it is not designed for use in households or by children.
Questions about the following compliance information may be directed to the following address:
Tektronix, Inc. PO Box 500, MS 19-045 Beaverton, OR 97077, USA www.tek.com
EMC compliance (TCPA300/400 only)
EU EMC Directive
Meets intent of Directive 2014/30/EU for Electromagnetic Compatibility. Compliance was demonstrated to the following specications as listed in the Ofcial Journal of the European Communities:
EN 61326-1, EN 61326-2-1. EMC requirements for electrical equipment for measurement, control, and laboratory use.
1234
CISPR 11. Radiated and conducted emissions, Group 1, Class A
IEC 61000-4-2. Electrostatic discharge immunity
IEC 61000-4-3. RF electromagnetic eld immunity
IEC 61000-4-4. Electrical fast transient/burst immunity
IEC 61000-4-5. Power line surge immunity
IEC 61000-4-6. Conducted RF immunity
IEC 61000-4-11. Voltage dips and interruptions immunity
EN 61000-3-2. AC power line harmonic emissions
EN 61000-3-3. Voltage changes, uctuations, and icker
1
This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
Emissions which exceed the levels required by t his s tandard may occur when this equipment is connected to a test object.
3
Equipment may not meet the immunity req probes are connected due to coupling of electromagnetic interference onto those leads/probes. To minimize the inuence of electromagnetic interference, minimize the loop area between the unshielded portions of signal and associated return leads, and keep leads a s far away as possible from electromagnetic disturbance sources. Twisting unshielded test leads together is an effective way to reduce loop area. For probes, keep the ground
uirements of applicable listed standards when test leads and/or test
6Amplifiers and Current Probes Compliance and Safety Instructions