TEC APO140
TEC APO140
OWNER’S MANUAL 2013
This telescope is closer to opcal perfecon more
than any instrument I have ever used before.”
R.Renzi, Italy.
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 1
IMPORTANT - PLEASE READ THIS MANUAL BEFORE
SAFETY PRECAUTION
Do not look at the sun through the telescope!
Viewing the sun through the telescope without special equipment (Solar Filter, Herschel Wedge) will cause permanent visual impairment and damage to telescope components.
Do not disassemble!
Disassembly of the telescope could result in personal injury and telescope malfunction.
Do not use hairdryer to remove dew condensation from the front lens!
CONTACT INFORMATION
If you have any questions or need assistance - please contact us: Phone 303 273 9322 • Fax: 303 273 0204 E-mail tec@telescopengineering.com Web site www.telescopengineering.com User’s group http://groups.yahoo.com/group/tec-scopes Address Telescope Engineering Co. • 15730 West 6th Ave., Golden CO, 80401. USA
TEC APO 140 TECHNICAL SPECIFICATIONS
Clear aperture 5.5” / 140 mm Focal length 980 mm Focal ratio 7.0 Image scale 3.5 arc min/mm Resolution (theor.) 0.8 arc sec
Focuser TEC 4” / 96mm ID Eyepiece holder 2” Collet type (no plastic parts) Focusing range 4.5” / 114 mm One turn focus travel: Coarse 18.3 mm Fine (small knob) 1.8 mm Back focus distance 6.70” / 170 mm Focuser load capacity 12 lb / 5.5kg
Tube assembly dia. 5.9” / 150 mm Dew shield dia. 7.0” / 178 mm OTA length (shortest) 34” / 860 mm OTA weight 19 lb / 8.6 kg (for tube ring add 2lb) Weight with case 18 lb / 8.2 kg incl. keys
Price 2013 $5700 Includes : Optical tube assembly, front cover, plug.
Note: All prices, specifications and availability subject to change without notice.
2
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 2
OPTIONAL EQUIPMENT (see www.telescopengineering.com for up to date prices)
Tube rings $280 Finderscope bracket with base $120 TEC 9” narrowed dovetail plate $70 TEC 12” narrowed dovetail plate $90 7X50 VIXEN finderscope with illuminated eyepiece $190 10x60 Baader Planetarium VARIO finder w. prism & illum. EP $290 Eyepiece Turret $500 Field Flattener $750 Transportation case (hard case made in Germany) $460
OVERVIEW
The APO140 ED is TEC’s first production model of apochromatic refractor and it is our “best seller” telescope, since start in the end of 2002 about 600 telescopes have been sold.
Scope has number of features that in given combination are rarely found in one scope:
• Compact, lightweight tube assembly with retractable baffle and precision adjustable tube rings.
• Case for telescope has “carry-on” dimensions for most airlines (since these dimensions could change, please double check weight/dimensional limitation prior to your flight).
•Telescope objective being “oiled triplet” by design transmits more light than any other type of objectives; combination of “oiled \” design and modern coating that makes lenses almost invisible.
• Precision rotatable focuser with coarse and fine focusing, with 2”eyepiece holder.
• The focuser features a specially designed collet made of metal wich is insensitive to temperature and holds loads with high precision when concentricity of focuser tube and axis of the eyepiece or camera attained automatically by definition.
3
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 3
4
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 4
1 2 3
9
10
10.1
9
9
11
12
13
13
14
4 5 6 7 8
TEC LARGE FOCUSER
The TEC  focuser for APO140 and larger telescopes has been designed and made in our shop. While similar in appearance to other focusers on the market, it has a few special features that were required for today's imaging:
• It is all metal 2" collet type holder; being all metal it does not change holding force under colder temperatures and would not be damaged from sun heat exposure either.
• Holding capacity (axial load) of TEC collet itself is over 3 times the telescope weight - thanks to special design of the collet. Compared to traditional thumb screw holders the collet type holder keeps item's axis strictly concentric to focuser axis by definition.
• Focuser draw tube is held in the focuser housing all the way around that also makes the axis of draw tube strictly concentric to the optical axis of the telescope. Holding draw tube in such a way makes focuser more robust, it has virtually no play under radial load, 7lb weight shifts fully extended draw tube for less than 20mk.
• The planetary mechanism ratio is 1:10 and one turn of the fine focusing knob moves focuser tube 1.8mm.
• The TEC focuser is "dry" - no oiling is required on the draw tube - this will keep focuser draw tube free from dirt.
FOCUSER  PARTS
1. Focuser locking collar with 3 pegs
2. TEC  logo
3. Focuser housing
4. Focuser draw tube
5. Draw tube end cap
6. End cap locking screws (3X)
7. Collet locking nut
8. Collet sleeve
9. Coarse focus knobs (CFK)
10. Fine focus knob (FFK)
10.1 Fine Focus Lock knob (FFLK)
11. Left knob set screw
12. Pinion shaft housing
13. Pinion shaft housing threaded holes (4X)
14. Pinion housing screws (3X).
5
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 5
FOCUSER PARTS DESCRIPTION
Focuser locking collar (1) connected to the OTA flange (not shown) and holds focuser on the end of telescope. Loosening it will allow you to rotate the focuser to any position.
NOTE
: The focuser can be completely removed by unscrewing the locking collar completely and then pulling the focuser from the OTA flange. This should only be done in rare special circumstances. Please contact TEC before removing focuser for any reason.
Focuser draw tube (4) has laser engraved mm scale, inside it is painted with flat black paint and has number of knife-edge baffles to reduce internal reflections at low angles. Draw tube end cap (5) with Collet locking nut ((7) and Collet sleeve (8) are assembled as one unit. This unit can be removed by loosening three 6-32 set screws (6) and unscrewing it completely. The Field Flattener for wide field imaging could then be screwed onto the focuser draw tube end.
The Collet sleeve is made of Aluminum, its surface is tumbled and left un-anodized to avoid scratching the barrel of eyepiece or other equipment, also coefficient of friction of unanodized aluminum is higher than for anodized aluminum.
NOTE: keep the Collet locking nut tightened at all times to avoid droping /damaging your equipment!
Coarse focusing knobs (9), here and further CFK and Fine focusing knob (10), FFK have special shape slots cuts around of cylindrical surface for better tactile feeling during focusing. Left focusing knob can be removed by loosening set screw (11), a Robofocus or other brand of electrical motors can be installed instead, use 4-40 threaded holes (13) for motor bracket installation. Please note: the pinion shaft diameter is 1/4”.
The movement and feel of the CFK (9) and FFK (10) is preset by TEC before shipping; however, the "Feel" may be adjusted to your liking. By increasing the friction between the CFKand FFK the load carrying and holding ca pacity will also be increased. To increase the friction felt and increase the load carrying capacity, first, using your left hand, grip the FFK, then
with your right hand, loosen the Fine Focus Lock Knob, FFLK (10.1) by turning it counterclockwise. Next, while holding the CFK, turn the FFK by approximately 10 degrees clockwise (about 1/2 the angle between two slotted cuts on the course focus knob). Finish by resetting the FFLK by gripping the FFK and turn in the FFLK clockwise and tighten it. Please note, the steps to loosen up the "feel" is the same as above with the exception of turning the FFK 5-10 degrees counterclockwise. Please note, while giving a looser feel, this will reduce the load capacity and
holding capacity of the focuser, particularly pointing at the zenith. Moreover, the holding capacity of the focuser can be increased up to full lock-up if needed.
Pinion shaft housing (12) attached to the focuser housing (3) with 4-40 socket head cup screws (14). Position of the pinion housing with pinion shaft relatively to the rack (installed on the focuser draw tube), is precisely adjusted by TEC during assembly.
Please avoid unscrewing these screws.
The Focuser housing (3) also has two 8-32 threaded holes for finder base installation (these holes are on the left from TEC logo) not shown on given sketch. If finder base is to be installed on the focuser housing, make sure the screws being used are of correct length to avoid scratching/damaging internal parts of the focuser housing.
Please contact TEC if you have question about the length of the finder base screws.
WARNING:
Do not ever try to disassemble the focuser for any reason, it can not be done without proper tools and
without knowing its internal structure. Attempt to disassemble focuser may end with focuser parts damage
and loosing warrantee. Contact TEC if you have any issues or question about the focuser.
6
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 6
7
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 7
8
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 8
9
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 9
CLEANING  AND  HANDLING  YOUR  TELESCOPE
The tube assembly and front baffle are powder coated; to clean them use water with soap or mineral spirits (paint thinner); do not use Acetone or any other strong chemicals. Please contact us if you need the lens to be cleaned.
Handling the telescope around and it’s transportation to the observing site requires careful handling. We recommend to keep the telescope in the case when it is not in use.
If you find any problems, or have any comments - please call us for assistance. Telescope Engineering Company is commited to serving it’s customers after sale for unlimited time. See the info on the second page of this manual.
Remember - your feedback makes our telescopes better.
Yuri Petrunin, TEC President
10
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 10
Loading...