Multiple units can be mounted on top of each other when forced air rack ventilation is provided.
a one inch clearance is required on both sides of the MX-2424 (even in single-unit installations).
In facilities with raised computer-room style flooring, a ventilation opening in the floor is recommended. In no case should the internal rack temperature ever exceed 100 degrees Fahrenheit
(43 degrees Centigrade) during operation (as measured at the rear of any MX-2424 in the system).
When mounting MX-2424's on top of each other in a rack
the feet may be removed by unscrewing them.
To replace the feet:
1. Insert the fastener into the foot
2. Snap the fastener & foot back into the hole in the bottom of the MX-2424 chassis
3. Snap the screw into the fastener's hole
CONNECTING THE MX-2424
Following is a listing/description of cables required to make connections to the MX-2424. Please note that while
some cables look similar in appearance they may be wired/constructed very differently. Always use the correct
cable!
[53]Analog Multi-Track Connections
To connect the inputs/outputs of an analog device with balanced DB25 connectors to the analog inputs/outputs of
the IF-AN24 if installed in the MX-2424 (NOTE: This is not a TDIF or AES/EBU cable.):
CU/SD103DB25(M) – DB25(M)3 Meters
CU/SD105DB25(M) – DB25(M)5 Meters
⇒8 Channels, input or output per cable
To connect the outputs of the IF-AN24 if installed in the MX-2424 to the inputs of an analog device with XLR
connectors:
CU/SD203DB25(M) – XLR(M)3 Meters
CU/SD205DB25(M) – XLR(M)5 Meters
⇒8 Channels per cable
To connect the outputs of an analog device with XLR connectors to the inputs of the IF-AN24 if installed in the
MX-2424:
CU/SD303DB25(F) – XLR(F)3 Meters
CU/SD303DB25(F) – XLR(F)5 Meters
⇒8 Channels per cable
To connect the inputs/outputs of an analog device with balanced ¼” TRS connectors to the analog inputs/outputs of
the IF-AN24 if installed in the MX-2424:
CU/SD403DB25(M) – ¼” TRS(M)3 Meters
CU/SD405DB25(M) – ¼” TRS(M)5 Meters
⇒8 Channels, input or output per cable
[52]Digital Multi-Track Connections
To connect digitally to another device using TDIF connections when the IF-TD24 is installed in the MX-2424
(NOTE: This is not an AES/EBU or analog cable.):
CU/PW88DSTDIF Cable0.5 Meter
CU/PW88DTDIF Cable1 Meter
CU/PW88DMTDIF Cable3 Meters
CU/PW88DLTDIF Cable5 Meters
⇔8 Channels, input and output per cable
To connect digitally to another device using Adat Optical connections when the IF-AD24 is installed in the MX2424:
CU/ADOP03Fiber-Optic Cable1 Meter
CU/ADOP06Fiber-Optic Cable2 Meters
CU/ADOP16Fiber-Optic Cable5 Meters
⇒8 Channels, input or output per cable
To connect digitally to another device using AES/EBU connections when the IF-AE24 is installed in the MX-2424:
CU/AES825AES/EBU DB25(M) – XLR(M) x 4 and XLR(F) x 48 Meters
⇔8 Channels, input and output per cable
CU/AES2503AES/EBU DB25(M) – AES/EBUDB25(M)1 Meter
CU/AES2510AES/EBU DB25(M) – AES/EBUDB25(M)3 Meters
CU/AES2516AES/EBU DB25(M) – AES/EBUDB25(M)5 Meters
(NOTE: This is not a TDIF or analog cable.)
⇔8 Channels, input and output per cable
[55]AES/EBU Stereo Digital Audio Connections
To connect digitally to another stereo device using AES/EBU (XLR) connections:
CU/AES103XLR(M) – XLR(F) 110 Ohm1 Meter
CU/AES110XLR(M) – XLR(F) 110 Ohm3 Meters
CU/AES116XLR(M) – XLR(F) 110 Ohm5 Meters
[54]SPDIF Connections
To connect digitally to another stereo device using SPDIF (Coaxial) connections:
CU/SPD106Double-Shield Coax 75 Ohm RCA – RCA2 Meters
CU/SPD110Double-Shield Coax 75 Ohm RCA – RCA3 Meters
CU/SPD113Double-Shield Coax 75 Ohm RCA – RCA4 Meters
[58]Remote Connection
This cable comes with the RC-2424.
[56}Footswitch Connection
This cable is already attached to the footswitch or LRC.
[59]TL-Bus Connection
This cable is used to synchronize MX-2424’s on the TL-Bus:
CU/MXBUS01 1 Meter
[61]Video Sync In/Thru Connections
This cable is used to connect to another device to provide video sync to the MX-2424:
CU/BB102BNC – BNC 75 Ohm RG592 Meters
CU/BR202BNC – RCA 75 Ohm RG592 Meters
[62]Net Connection
Category 5 Ethernet cables are used to connect the MX-2424 to a computer running the ViewNet application. When
connecting directly to a computer a Crossover Cable is used. When connecting to a computer through an Ethernet
hub a Straight Cable is used.
[63]SCSI Connection
Please refer to SCSI & The MX-2424 for detailed information about SCSI cables.
[57]Word Clock In/Out/Thru Connections
This cable is used to digital word clock connections between other equipment and the MX-2424:
CU/BB102BNC – BNC 75 Ohm RG592 Meters
CU/BR202BNC – RCA 75 Ohm RG592 Meters
[51]Time Code In/Out/Thru Connections
This cable is used for time code connections between other equipment and the MX-2424:
CU/AB202¼” TRS(M) – ¼” TRS(M)2 Meters
CU/AB203¼” TRS(M) – ¼” TRS(M)3 Meters
CU/AB205¼” TRS(M) – ¼” TRS(M)5 Meters
⇔For time code in/out of the MX-2424.
CU/AB302XLR(M) – ¼’ TRS(M)2 Meters
CU/AB303XLR(M) – ¼’ TRS(M)3 Meters
CU/AB305XLR(M) – ¼’ TRS(M)5 Meters
⇒For time code output from the MX-2424 to a device with XLR time code connections
CU/AD402XLR(F) – ¼” TRS(M)2 Meters
CU/AD403XLR(F) – ¼” TRS(M)3 Meters
CU/AD405XLR(F) – ¼” TRS(M)5 Meters
⇒For time code input to the MX-2424 from a device with XLR time code connections
[60]MIDI In/Out/Thru Connections
This cable is used for MIDI connections between the MX-2424 and other equipment.
CU/MD2010.3 Meter
CU/MD2031 Meter
CU/MD2051.5 Meters
CU/MD2103 Meters
CU/MD2154.5 Meters
CU/MD2206 Meters
CU/MD2257.5 Meters
[64]IEC 3-Prong AC Connection
This is where the power cord goes.
CU/PWCD8MX-2424 to wall outlet power cord2.5 Meters
This is a standard 3-prong power cord.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.