Taser X26P User Manual

Page 1
TASER® X26P™ ECD
Models 11000, 11001, 11002, 11003
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions. Save these instructions.
MMU0042 Rev: A
Page 2
Contents
4 Chapter 1: Warnings 4 Important Safety and Health Information
4 Use of Force Policy 5 Firmware Update
6 Chapter 2: General Information 6 What is the TASER X26P ECD? 6 Neuro Muscular Incapacitation (NMI) 7 Common Eects of NMI 7 Basic X26P ECD Electrical Theory
8 Chapter 3: Features 8 X26P ECD Features 8 Safety Switch 9 LASER 9 Mechanical Sights 9 Tactical Accessory Power Interface 9 Performance Power Magazine (PPM) Battery Pack 10 Changing the Battery Pack 11 Tactical Performance Power Magazine (TPPM) Battery Pack 11 eXtended Performance Power Magazine (XPPM) Battery Pack 11 Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack 12 Advanced Central Information Display (CID) 12 System Status Icons 13 Battery Level Icons 14 Spark Duration 14 Sample CID Displays 15 LED Flashlight 15 Selector Switch (LASER and LED Flashlights) 16 Trigger Switch 17 Ergonomic Grip Design
18 Chapter 4: Cartridges & ECD Operation 18 Removing the Shipping Cover from the Cartridge 18 15, 21, LS, and XP25™ TASER Cartridges 19 AFID 19 Load the TASER Cartridge
2
Page 3
20 Loading 20 Unloading 20 Aiming and Probe Placement 21 "Silence Is Golden" 21 Potential Causes of Reduced or No Eectiveness 22 Electrodes 22 Drive-Stun Backup 23 Recommended Drive-Stun Areas for Maximum Eect
24 Chapter 5: Maintenance/Troubleshooting 24 Function Test 24 Function Test Instructions 25 What to Do Following ECD Use 25 Considerations for Handling Used Probes 25 Eects On Animals 26 Police/Military K-9 Caution 26 Uploading Firmware Revisions 26 Dataport Download Kit 26 USB Connection Status 26 EVIDENCE Sync Oine Software 27 Trilogy Log 27 Event Log 27 Pulse Log 28 Engineering Log 28 Time Synchronization 28 X26P ECD Maintenance and Care 29 Dropped or Wet X26P ECD 29 TASER Online Troubleshooting Guide 29 Product Returns
30 Chapter 6: Optional Accessories 30 EVIDENCE.com 30 EVIDENCE Sync Oine Software 30 TASER CAM HD Recorder 31 Holsters
32 Chapter 7: Additional Items 32 Additional Information 32 TASER Training Academy 33 Medical Research
3
Contents
Page 4
Warnings
1
Important Safety and Health Information
Read, understand and follow the most current product warnings, safety instructions, and training materials. All product warnings are not included in this Manual. A Product Warnings document is included with this electronic control device (ECD) and the most current warnings are posted on our website at www.TASER.com. The most current training materials are available by contacting TASER’s Training Department. Do not attempt to use this ECD until you have completed training with a TASER International, Inc. (TASER) Certied Instructor.
WARNING
Complete Training First
Signicant dierences exist between each of the TASER ECD models. Do not use or attempt to use any ECD model unless you have been trained and certied by a Certied TASER Instructor on that particular model.
Read and Obey
Read, study, understand, and follow all instructions, warnings, information, training bulletins and TASER training materials before using the TASER X26P™ ECD. Failure to comply with the product instructions, warnings, information, training bulletins, and TASER training materials could increase the risk of or result in death or serious injury to the user, force recipient, and others.
Obey Applicable Laws
Use the ECD only in accordance with applicable federal, state, and local laws and other regulations or legal requirements. Your agency’s guidance must also be followed. Any ECD use must be legally justiable.
Electronic Control Device
Can temporarily incapacitate target.
Can cause death or serious injury.
Obey warnings, instructions and all laws.
Comply with current training materials and requirements.
See www.TASER.com.
TASER® ECDs are designed in probe-deployment mode to temporarily incapacitate a person from a safer distance while reducing the likelihood of serious injuries or death. When used as directed, TASER ECDs have been found to be safer and more eective than other traditional use-of-force tools and techniques. However, it is important to remember that the use of force and physical incapacitation, by their very nature, involve risk that someone will get hurt or may even die from factors that include, but are not limited to: physical resistance, exertion, individual susceptibilities, and/or unforeseen circumstances. Any use of force or physical exertion involves risks that a person may get hurt or die.
Use of Force Policy
Each agency is responsible for creating its own use-of-force policy and determining how TASER ECDs t into their use-of-force matrix based on legal and community standards. Make sure your agency has a use-of-force
4
Page 5
policy that addresses TASER ECD use and that this policy is clearly addressed during end-user training.
Firmware Update
Before using your X26P ECD, conrm with your armorer or other qualied person that the X26P rmware has been updated.
5
Chapter 1 Warnings
Page 6
General Information
2
What Is the TASER X26P ECD?
The X26P ECD is a software upgradable weapon manufactured by TASER International, Inc.
The X26P ECD uses a replaceable cartridge containing compressed nitrogen to deploy two small probes that are attached to the X26P ECD cartridge by insulated conductive wires. The cartridges are available with various wire lengths from 15' to 25' (4.6 m to 7.6 m). Sale of cartridges with wire length longer than 15' is limited to law enforcement and military only.
The X26P ECD’s Trilogy™ log can be uploaded securely to EVIDENCE.com. The X26P ECD has an internal memory that stores the operating software and a deployment record. See the Trilogy Log section in this manual for more details. Those who do not have an EVIDENCE.com account can use the Oine EVIDENCE Sync software to download a simplied log to a local computer.
The X26P ECD has an estimated useful life of 5 years.
Neuro Muscular Incapacitation (NMI)
TASER technology is designed to use electrical impulses similar to those in your body’s nervous system to cause stimulation of the sensory and motor nerves. Neuro Muscular Incapacitation (NMI) occurs when an ECD is able to cause involuntary stimulation of both the sensory nerves and the motor nerves. It is not dependent on pain and can be eective on subjects with a high level of pain tolerance.
Previous generations of stun guns primarily aected the sensory nerves only, resulting in pain compliance. A subject with a very high tolerance to pain (e.g., a drug abuser, person in serious psychological distress, or a trained, focused ghter) may not be aected by the pain or might be able to ght through the pain of a traditional stun gun.
6
Page 7
Common Eects of NMI
WARNING
The use of TASER technology is designed to cause incapacitation and strong muscle contractions making secondary injuries a possibility. These potential injuries include but are not limited to: cuts, bruises, impact injuries, and abrasions caused by falling, and strain-related injuries from strong muscle contractions such as muscle or tendon tears, or fractures. These injuries are secondary in nature and not directly attributable to the electric output of the ECD, but are possible consequences of the strong muscle contractions the ECD may induce.
Some of the eects may include:
• Falls immediately to the ground and be unable to catch oneself;
• Risk of drowning if ability to move in water or wet environments is restricted;
• Yelling or screaming;
• Involuntary strong muscle contractions;
• Freezing in place with legs locked;
• Dazed feeling for several seconds or minutes;
• Potential vertigo;
• Temporary tingling sensation; or
• May experience critical stress amnesia (may not remember any pain).
For a full list of warnings, visit www.TASER.com.
Basic X26P ECD Electrical Theory
• Electricity must be able to ow between the probes to deliver an electrical charge and will generally follow the path of least resistance between the probes.
• The greater the spread between the probes on the target, generally the greater the eectiveness.
• Electricity will generally not pass to others in contact with the subject unless contact is made directly
between or on the probes, or the wires are touched.
• Electricity can arc through most clothing, and even some bullet-resistant materials.
• Exposure to water will not cause electrocution or increase the power to the subject (the electrical
charge is xed inside the TASER ECD, and will not increase signicantly even with environmental changes).
• The Current Metering technology is designed to deliver optimal charge.
• Medical studies have found that modern pacemakers and implanted cardiac debrillators withstand
external electrical debrillators many orders of magnitude stronger than the TASER ECD conducted energy pulses.
7
Chapter 2 General Information
Page 8
Features
X26P ECD Features
Get to know the X26P ECD:
Mechanical Sights
3
Illumination Selector
Safety Switch
TASER Cartridge
Probe
Wire
AFIDs
Blast Door
NOTE: The serial number is located inside the cartridge bay.
PPM Release Button
Textured Grip Zones
Performance Power
Cartridge Release Tab
Low Intensity Lights (LEDs)
Trigger
Magazine (PPM)
LASER
WARNING
Ensure the ECD is unloaded, the safety is in the down (SAFE) position, and your ngers are away from the trigger before reading the serial number.
Safety Switch
Ambidextrous safety can be operated from either side of the ECD.
• Safety switch down (SAFE).
• Safety switch up (ARMED) and ready to deploy.
• Do not block the safety on one side of the X26P ECD while attempting to move it on the other side. This
can break the safety and disable the ECD.
• With default settings, if the X26P ECD’s safety switch is left in the up (ARMED) position for more than 20 minutes, the system goes into low power mode to reduce the amount of power consumed, and the ECD will not re. The ECD will not re, but power is still consumed and will eventually drain the battery if the safety switch remains in the ‘ARMED’ position. (This feature can be turned o, which then will cause the X26P ECD to be left on indenitely when the safety is up (ARMED). See the Setting Auto Power Down (Power Save) section in this manual for more information.) To re-arm the ECD, shift the safety to the down (SAFE) position, and then shift it back to the up (ARMED) position.
8
Page 9
Down (SAFE)
Up (ARMED)
LASER
The LASER installed in the X26P ECD is oriented with the mechanical sights. At 15 feet (4.6 m), the aiming point is aligned to the approximate trajectory of a cartridge’s top probe.
Mechanical Sights
The mechanical sights on the X26P ECD are molded to provide manual aiming of the ECD. The mechanical sights are set to coincide with a top probe’s trajectory at a 15' (4.6 m) distance.
Front Mechanical Sight
Rear Mechanical Sight
Tactical Accessory Power Interface
This is a power plug for future X26P accessories.
Performance Power Magazine (PPM) Battery Pack
The Performance Power Magazine is a lithium energy cell power supply system for the X26P ECD.
NOTE: X26P battery packs will not work with the X3® or X26™ ECDs, and battery packs designed for the X3 or X26 ECDs will not work with the X26P ECD. Battery packs designed for the X2™ ECD will work in the X26P ECD.
Do not store the PPM anywhere that the gold contacts on the top of the PPM may touch metal objects. If you
9
Chapter 3 Features
Page 10
cause an electrical short between these contacts, the short will drain the battery and may cause the pack itself to become dangerously hot.
The PPM battery has enough power for approximately 500 ve-second discharges depending on temperature, environment, use of the ashlight, and other factors. The PPM battery will deplete faster in colder weather than warm weather. Likewise, the battery will deplete faster with the ashlight active.
For more information on installing the PPM, see the Changing the PPM Battery Pack section in this manual.
NOTE: Other battery pack options are available for the X26P ECD. See the Tac tical Performance Power Magazine
(TPPM) Battery Pack, Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack, and eXtended Performance Power Magazine (XPPM) Battery Pack sections in this manual.
Changing the Battery Pack
The X26 ECD is shipped with the DPM battery pack pre-installed. To change the battery pack:
1 Point the ECD in a safe direction.
2 Ensure the safety switch is in the down (SAFE) position.
3 Safely remove the TASER cartridge (do not place any body parts in front of the cartridge). See the Unloading
section in this manual for more information.
4 To unload the battery pack, depress the battery pack release button and remove the battery pack from the
handle of the ECD.
Release Button
5 Inspect the battery contacts. Ensure that they appear in working order and are free from dirt or other
residue that may interrupt the battery connection to the ECD.
6 Install the new battery pack and ensure that it is fully inserted into the X26P ECD. Apply sucient force to
ensure the battery pack is fully seated. When the battery pack seats properly, the release button should pop out from the recessed position with an audible click.
Chapter 3 Features
10
Page 11
Tactical Performance Power Magazine (TPPM) Battery Pack
The optional TPPM has an extension to provide a larger grip on the ECD. The TPPM does not hold an extra cartridge.
eXtended Performance Power Magazine (XPPM) Battery Pack
To install a cartridge in an XPPM:
1 Keeping your hand away from the blast doors, depress the tabs on the sides of the cartridge.
2 Insert the cartridge in the XPPM so the blast doors face forward, toward the front of the ECD. You should
hear a click when the cartridge seats in the XPPM.
To remove the cartridge, keeping your hand away from the blast doors, depress the tabs again and pull the cartridge out of the XPPM.
Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack
The optional APPM is a modied battery pack that shuts down the output of the X26P ECD after 5 seconds and also contains a built-in speaker that alerts you to the impending shut down.
WARNING
Under stressful situations, audio exclusion might prevent you from hearing the alert from the APPM.
The APPM provides an audible beeping alert for the last 2 seconds of a trigger-initiated cycle before automatically shutting down the cycle. After 5 seconds’ deployment duration, the energy burst will stop even if your nger is still pulling the trigger switch. To reenergize the deployed cartridge, rst ensure that your nger is o the trigger switch, and then press the trigger again.
11
Chapter 3 Features
Page 12
Your ECD will recognize the APPM as a unique type of battery pack. If you remove the APPM and replace it with a dierent type of battery pack, the X26P ECD will return to its normal conguration. That is, there will no longer be an audio alert, and the energy cycle will continue after 5 seconds if your nger is still holding down the trigger switch. Always conrm that the ECD performs as expected before returning it to duty after changing any battery pack.
WARNING
Remove the cartridge before testing the ECD function. See the Unloading section in this manual for more information.
Advanced Central Information Display (CID)
The CID is a monochrome organic light emitting display on the back of the X26P ECD. When the safety switch is shifted into the up (ARMED) position, the CID will display the battery status.
Energy Cell Indicator:
61-80% Remaining
System Status Icons
WARNING
The system status icons are designed to inform you of the system status of the X26P ECD. It is the user’s responsibility to conduct proper maintenance and repair, and ensure that the ECD is working properly before any use. Failure to heed the system status icons could cause serious injury or death.
Major Fault indication. A yellow triangle indicates that the logging or date and time functions are not working properly. The ECD will still produce an electrical output (e.g., the ECD should still arc and deploy cartridges), but the accountability functions are compromised.
Shift the safety switch to the down (SAFE) position and then to the up (ARMED) position; the fault may clear. If the fault does not clear, it may still be possible to use the ECD for a short time.
Whether the fault clears or not, it will be recorded in the Engineering log. If the fault does not clear, and the ECD is still under warranty, send the ECD to TASER International for repair.
Chapter 3 Features
12
Page 13
Critical Fault indication. A yellow stop sign in the upper-right side of the CID
indicates a system failure. The ECD is NOT to be used.
Do NOT attempt to use the ECD. Contact TASER International customer service.
Invalid Battery Pack. If you see a blinking exclamation point and battery icon, this indicates that the ECD did not recognize the battery correctly. Remove the battery pack and reinsert it. If the error is still present, try another battery pack. If the icon still displays, the ECD should be sent in for service if it is still under warranty.
An APPM battery pack is installed in the ECD.
A TASER® CAM™ HD recorder is installed in the ECD.
A TASER CAM HD recorder with the automatic shut-down feature is installed in the ECD. This recorder oers an audio warning and shut-down feature like that of an APPM battery pack.
The USB connection status icon displays when the USB connection is good.
Battery Level Icons
When the safety switch is in the up (ARMED) position, the CID will display the percentage of battery power remaining. Remaining capacity will display in 19 percent increments.
When the battery level drops to 20 percent, TASER International recommends that the battery pack be replaced.
Battery 81– 100%
Battery 61– 80%
Battery 41– 60%
Battery 21– 40%
When the battery capacity is at 1–20 percent, the CID will ash the warning LO BAT T on the CID when the safety switch is cycled to the up (ARMED) position.
13
Chapter 3 Features
Page 14
If the battery capacity is at 1–20 percent, and the ECD is being discharged, this icon displays in the lower-right portion the CID.
Battery 01– 20% Blinking
If the battery is depleted, a zero percent indication (00%) will ash on the CID when the safety is shifted to the up (ARMED) position. The ECD then will shut down and not operate.
Battery Depleted
Spark Duration
The CID displays a count indicating how many seconds the deployment cycle lasts. The ECD will count up from the number 1 up to 99. At 99 seconds, the count will restart at 1.
Sample CID Displays
The CID below shows the X26P ECD with a TASER CAM HD recorder installed and a battery capacity of 61–80 percent.
TASER CAM HD Recorder
Battery: 61-80% Remaining
The CID below shows an ECD that has been discharging for 4 seconds, with a battery pack that is at 41–60 percent capacity.
Count
Battery: 41- 60% Remaining
The CID below shows an ECD with an APPM battery pack installed that has a battery capacity of 61–80 percent.
Chapter 3 Features
14
Page 15
APPM Installed
Battery: 61-80% Remaining
The CID below shows an ECD with a battery pack error.
Invalid Battery Pack
The CID below shows an ECD that is 4 seconds into an energy burst, has a battery pack that is 81–100 percent charged, and a major fault with the ECD.
Major Fault
Count
Battery: 81- 100% Remaining
LED Flashlight
The X26P ECD has a high intensity white LED to aid the user in dark environments.
Selector Switch (LASER and LED Flashlights)
You can select four modes of illumination when using the X26P ECD. To change the illumination setting:
1 Point the ECD in a safe direction.
2 Ensure the safety switch is in the down (SAFE) position.
3 Keeping your hand away from the blast doors, depress the tabs on the sides of the cartridge and remove.
4 Press and hold the selector switch for approximately 1 second until the CID display illuminates.
15
Chapter 3 Features
Page 16
NOTE: Using pens or paper clips to press the selector switch may damage it. Only use your nger to press the selector switch.
5 Press and release the selector switch to toggle through the four available settings until the setting you
desire is designated on the CID. Stop when the setting you desire is displayed.
OO: Neither the LASER nor the Flashlight will illuminate.
LO: Only LASER will illuminate
OF: Only Flashlight will illuminate
LF: LASER and Flashlight both illuminate
The selected mode displays for 5 seconds, and will be the default mode the next time the safety switch is moved to the up (ARMED) position.
The selector switch may also be used to activate the Stealth Mode, which will shut o the LASER and ashlight, and dim the CID display. To do this, press the selector switch when the safety is in the up (ARMED) position. To take the ECD out of Stealth Mode, press the selector switch again or shift the safety to the down (SAFE) position. You will have to reactivate the Stealth mode each time you place the safety in the up (ARMED) position.
WARNING
Do not place your ngers or any part of your body in front of the cartridge when activating the Stealth Mode.
Trigger Switch
Unlike a rearm trigger, the X26P ECD trigger is a momentary electrical switch. The switch is operational only when the safety switch is in the up (ARMED) position. Pulling and releasing the trigger switch will result in an approximately 5-second discharge cycle unless the safety switch is shifted to the down (SAFE) position to discontinue the 5-second cycle. Pulling and holding the trigger switch for more than 5 seconds will result in a continuous discharge until the trigger switch is released, or the battery is depleted—whichever comes rst.
Chapter 3 Features
16
Page 17
An X26P ECD equipped with the APPM battery pack is limited to 5-second discharges and emits an audio alert 2 seconds before the end of the cycle. See the Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack section in this manual for more information.
WARNING
In the event of an accidental discharge, immediately move the safety switch to the down (SAFE) position to stop the discharge cycle.
Trigger Switch
Ergonomic Grip Design
The handle of the X26P ECD is optimized for comfort with specic features for safe and eective use for people of most sizes.
17
Chapter 3 Features
Page 18
Cartridges & ECD Operation
4
Removing the Shipping Cover from the Cartridge
Cartridges are shipped with a shipping cover in place. Carefully remove these covers before attempting to load a cartridge into the X26P ECD. Be careful to not allow any body part to be in front of the cartridge. Static electricity can discharge a cartridge, and injuries have occurred. A cartridge cannot be loaded into the ECD with the cover in place. Once the cartridge cover is removed, it can be disposed of.
1 Before removing the covers, make sure the front of the cartridge does not point at any body part or at
anyone.
2 Carefully place the cartridge with cover face down (blast door down) onto a stable/solid surface, i.e., a table.
3 Place your index and middle ngers onto the sides of the cartridge where the wedges/electrodes are
located and place your thumbs onto the locking portions of the cover.
4 Push in with your ngers and pull outward with your thumbs and the cartridge will pop upward, releasing
it from the cover.
NOTE: The cartridge may pop upward quickly when the pressure is released from the locking portions of the cover.
15, 21, LS, and XP25™ TASER Cartridges
WARNING
Never attempt to open or modify a TASER cartridge. Tampering with a live TASER cartridge could cause it to re or malfunction (which may result in serious injury).
Handle all TASER cartridges with care. Probes may deploy unexpectedly if exposed to physical shock, or static electricity.
18
Page 19
TASER cartridges should be kept away from conditions known to create an electrostatic discharge, such as rubbing cloth (e.g., jacket liner or uniform pants) across a cartridge in an environment known to create static shocks.
Cartridge blast doors can be knocked o the front of a cartridge. Because those cartridges cannot be relied upon to consistently discharge, TASER recommends removing those cartridges from service. Attempting to deploy a cartridge with no blast doors could result in a charge being created and held in the wires. Any conductive material that comes into contact with the front of the cartridge, even after the cycle has ended, could draw the charge to the ignition pin and deploy the probes.
TASER oers a Blast Door Repair Kit that can be used to replace blast doors that come o. Cartridges with replaced blast doors should only be used for training and should not be deployed to the eld. Go to www. TASER.com for more information on the Blast Door Repair Kit.
AFID
Every time a TASER cartridge is deployed, approximately 20–30 small confetti-like Anti-Felon Identication (AFID) tags are ejected. Cartridges can be assigned to individual users, as each is serialized. Each AFID tag is printed with the corresponding serial number of the cartridge deployed, allowing determination of which user deployed the particular cartridge.
19
Load the TASER Cartridge
WARNING
Never place your hands or ngers in front of the cartridge. This is especially important when loading and unloading the cartridge. Serious injury could result. When loading and unloading always hold the cartridge on the sides or top.
TASER cartridges are shipped with a shipping cover in place. Remove these covers before attempting to load a cartridge into an X26P ECD. See the Removing the Shipping Cover from the Cartridge section in this manual for more information.
Chapter 4 Cartridges & ECD Operation
Page 20
Loaded
Unloaded
Load the TASER Cartridge
Loading
1 Point the ECD in a safe direction.
2 Ensure that the safety switch is in the down (SAFE) position.
3 Make sure the protective shipping cover is removed from the TASER cartridge.
4 Keeping your hand away from the blast doors, place the cartridge (with the cartridge cover removed) into
the front of the ECD until an audible click is heard.
5 Verify that the cartridge is secure by pulling on the sides of the cartridge.
Load the TASER Cartridge
Unloading
1 Point the ECD in a safe direction.
2 Ensure that the safety switch is in the down (SAFE) position.
3 Keeping your hand away from the blast doors, depress the tabs on the sides of the cartridge and remove.
The 15-, 21-, and 25-foot (4.6- , 6.4-, and 7.6-meter, respectively) TASER cartridges are specically designed so there is no “up” or “down” position – enabling you to quickly reload one in a stressful situation without worrying about putting it in upside down.
Aiming and Probe Placement
Level Tilted
Chapter 4 Cartridges & ECD Operation
20
Page 21
For most deployments, hold the ECD level. Do not tilt the ECD unless it is necessary to do so to align the ECD with the target.
All TASER ECD deployments should be in accordance with current TASER training and warnings, and department training, policies, and procedures.
Normally, aim the LASER at the preferred target areas of the body, which are the lower center-mass (below the chest) and legs when the subject is facing you, or the subject’s back if the subject is turned away from you.
WARNING
When possible, avoid intentionally targeting the ECD on sensitive areas of the body such as the head, throat, chest/breast, or known pre-existing injury areas without legal justication.
The top probe impacts the target near the LASER beam; however, the probe impact distance from the LASER will vary depending on the distance between the ECD and the target, type of cartridge, etc. At 15' (4.6 m), the LASER’s position corresponds to the trajectory of a 25' (7.6 m) cartridge’s top probe at the same range.
The bottom probe impacts at an 8-degree angle from the top probe. This results in a spread of approximately 1' (0.3 m) for every 7' (2.1 m) of distance from the ECD. Greater probe spread increases eectiveness.
“Silence Is Golden”
The TASER ECD’s electrical current is relatively quiet when both probes make direct contact with a human or an animal. In contrast, some practice conductive targets are loud because the energy is arcing in the air.
If electrical current is loud during eld deployment and the subject is not reacting as expected, the electrical circuit may not be completed or the current may be shorting out and may not be eective. Deploy a second cartridge or consider other options in accordance with your agency's policies.
Potential Causes of Reduced or No Eectiveness
• Loose or Thick Clothing. If the probes lodge in clothing and are too far away from the subject, ECD eectiveness is reduced and can be eliminated.
• Miss or Single Probe Hit. The current must pass between the probes. If one probe misses, a second cartridge should be deployed if practical and legally justiable. Also, using the X26P ECD in the drive­stun mode as described below may complete the circuit between the single probe and the ECD electrode.
21
Chapter 4 Cartridges & ECD Operation
Page 22
• Low Nerve or Muscle Mass. If the probes impact in an area where there is very little muscle mass (e.g., the side of the rib cage), the eectiveness can be signicantly diminished.
• Limited Probe Spread. Probe spreads of less than 4 inches (10 cm) (including drive-stun) may result in little or no eect and become primarily a pain compliance option.
• Wires Break. If a wire breaks (e.g., during a struggle), the current will not ow to the probes and an additional deployment may be required. Drive-stun may still be available.
WARNING
Do not become over-dependent on the TASER ECD. No force option, including ECDs, is 100% eective in every situation. Do not deploy the ECD without following your department policies and procedures.
Electrodes
The front of the X26P ECD has two metal electrodes. These electrodes direct the charge to the electrodes on the cartridge to initiate deployment of the probes. In addition, the electrodes provide the ability to use the X26P ECD in a “drive-stun” mode as a traditional stun-gun type ECD.
Electrode
Electrode
Drive-Stun Backup
Drive-stun capability is available with or without a TASER cartridge installed. To apply a drive-stun, place the safety in the up (ARMED) position and pull the trigger. The drive-stun mode is not designed to cause NMI and generally becomes primarily a pain compliance option. Probe deployment is usually considered more desirable if NMI is the desired objective, even at close range. Some of the advantages of probe deployment include:
• Drive-stun is only eective while the ECD is in contact with the subject or when pushed against the subject’s clothing. As soon as the ECD is moved away, the energy being delivered to the subject stops. Deploying the probes allows the user to separate from the subject while maintaining control.
• Due to automatic reex actions, most subjects will struggle to separate from the ECD. Each time the ECD comes back in contact with the subject, another set of marks may be visible on the subject’s skin. Using the probes allows for one point of discharge.
• If the probes are deployed, even at very close range, the user may drive-stun to another portion of the body that is further away from the probes, thereby increasing the possibility of inducing NMI.
Chapter 4 Cartridges & ECD Operation
22
Page 23
If the drive-stun is not eective, evaluate the location of the drive-stun, consider an additional cycle to a dierent pressure point, or consider alternative force options in accordance with your agency's policies. When using the drive-stun, push (drive) the front of the X26P ECD rmly against the body of the subject. Simply “touching” the X26P ECD against the subject is not sucient. The subject is likely to recoil and try to get away from the ECD. It is necessary to aggressively drive the front of the ECD into the subject for maximum eect.
Recommended Drive-Stun Areas for Maximum Eect
Only use the X26P ECD pursuant to your agency’s policies and guidance. Drive the X26P ECD into the following areas for maximum eectiveness:
• Carotid (sides of neck) (see warning below).
• Radial (forearm).
• Pelvic triangle (see warning below).
• Outside of thigh.
• Tibialis (calf muscle).
WARNING
Use care when applying a drive-stun to the neck or groin. These areas are sensitive to mechanical injury (such as crushing to the trachea or testicles if applied forcefully). However, these areas have proven highly eective targets. These areas should only be targeted when users are defending themselves from violent attacks. Refer to your department’s policy regarding drive-stuns in these and other sensitive areas.
23
Chapter 4 Cartridges & ECD Operation
Page 24
Maintenance/Troubleshooting
5
Function Test
TASER recommends conducting a function test every 24 hours or prior to the start of your shift for your individually issued X26P ECD. The function test is done to verify that the ECD's core electronics are working properly.
There is no need to use an extended duration. As long you see a visible spark between the electrodes (2 to 3 seconds), the X26P ECD is functional.
Function Test Instructions
1 Point the ECD in a safe direction.
2 Shift the safety switch to the down (SAFE) position.
3 Remove the TASER cartridge. A function test should never be conducted with a TASER cartridge in the ECD.
4 Ensure that that your ngers and no other part of your body are in front of the X26P ECD.
5 Shift the safety switch to the up (ARMED) position.
6 Pull the trigger and visually conrm sparking across the electrodes.
WARNING
View the arc from the top or side of the ECD. Do not point the ECD at your face or have it near your face.
7 Look at the CID display and verify the following:
• No fault icons display on the CID.
• The battery icon displays a 20 percent or greater capacity.
If any of the above verications fail, return the unit to your agency’s ECD technician for service.
8 Shift the safety switch to the down (SAFE) position.
24
Page 25
What to Do Following ECD Use
Considerations for Handling Used Probes
Each agency will establish its own procedure for probe removal, collection, biohazards, evidence collection and maintenance. Treat probes that have penetrated the body as contaminated needles (biohazard). Remember, however, that the probes may also be valuable evidence.
If the probes must be removed from the subject, follow all department policies and procedures, including for handling biohazards.
Below are suggested methods for probe removal.
• Grab the probe rmly and quickly pull it straight out. Do not twist the probe as the barbed tip may cause additional injury.
• If the probes are not going to be collected and maintained for evidence, carefully place used probes sharp-tip rst into a sharps container, secure in place, and place in a secure location where no one will accidentally touch the probes.
• Once the subject is restrained, prior to removing the probes, evaluate the need for medical attention as you would with any other use-of-force incident.*
• Take photos of any injuries, place the photos into evidence.*
• Collect the expended cartridge, probes, and AFIDs and place them into evidence.*
25
* As directed by department policy. The TASER training materials provide additional information on forensic
evidence collection procedures. The probes, wires, AFIDs, and cartridge can yield important forensic evidence if properly collected, maintained, and analyzed. Ensure that the ECD is downloaded and the downloaded logs are collected per your agency’s policy.
Eects on Animals
The M26 and X26 ECDs can be an eective option for dealing with aggressive animals and have generally been successful in most deployments. The X26P ECD uses similar technology, but does not yet have the same service record as the previous models.
NOTE: If a probe deployment completed circuit is initiated and maintained, the aggressive animals are usually incapacitated/stunned momentarily in M26 and X26 deployments, but recover quickly. The vast majority of the animals quickly left the scene and broke the wires.
If deployed on a domestic animal, consider having animal control available to restrain the animal.
Chapter 5 Maintenance/Troubleshooting
Page 26
Police/Military K- 9 Caution
ECD operators and K-9 ocers must work closely together to develop policies and procedures for deploying the ECD when a K-9 is present. If a K-9 bites a probe or bites the suspect between the probes, the K-9 could receive a shock. This could have a negative impact on the future duty use of the K-9.
Uploading Firmware Revisions
The X26P ECD internal rmware provides functionality for all aspects of the ECD. The rmware can be upgraded to the most recent version by using an X26P/X2 ECD Dataport Download Kit (purchased separately) and EVIDENCE Sync software (Online or Oine).
CAUTION
Do not remove the USB cable or shift the safety switch to the up (ARMED) position during the reprogramming cycle.
Dataport Download Kit
Optional download kits are available to permit agencies to access the deployment information in the X26P ECD memory through the EVIDENCE Sync software (Online or Oine).
NOTE: If you have a TASER CAM HD recorder, please see the TASER CAM HD Operating Manual for downloading instructions.
The X26P ECD uses a USB adapter (download cable) to connect to any Windows® XP or Windows 7 computer. The simplicity of USB makes using the dataport download kit an easy, fast process. The cable connects to the ECD through the battery compartment.
USB Connection Status
The USB icon will blink at a 1-second rate when the connection is good.
EVIDENCE Sync Oine Software
If you do not have an EVIDENCE.com account, the EVIDENCE Sync software can be used in the Oine mode to download the simplied Event Log to your local computer and print it. The EVIDENCE Sync Oine software will not enable you to download the full Trilogy Log.
Chapter 5 Maintenance/Troubleshooting
26
Page 27
Trilogy Log
Upon upload to EVIDENCE.com, the system displays the information into 3 related data logs called the Trilogy Logs:
• Event Log
• Pulse Log
• Engineering Log
The data set from the Trilogy Log is uploaded securely to EVIDENCE.com , where the information is encrypted, stored securely, and organized into dashboards that allow your agency to easily monitor the usage and system status of your entire arsenal of X26P ECDs.
Upon upload to EVIDENCE.com, the system displays the information from the Event and Pulse Logs.
Event Log
The Event Log tracks events and may help protect a user from claims of excessive use of force by providing documentation of the time and date for each ECD deployment. The Event Log also provides agencies with a powerful management tool to track usage patterns and help prevent misuse. You do not need to download the X26P to EVIDENCE.com services to obtain the Event Log – this can be downloaded directly to your PC using the EVIDENCE Sync (Oine) software.
27
The Event Log includes the following information for the most recent 10,000+ records:
• Date, time, and duration of each discharge in local time.
• The beginning (safety switch up [ARMED]) and end of (safety switch down [SAFE]) of each session
• Temperature and battery percentage remaining.
• Record of any time changes made to the X26P ECD’s memory.
• X26P ECD serial number and current rmware version.
Pulse Log
The Pulse Log records any pulse activity. The records include how long the ECD was discharged, and the charge of every pulse.
Chapter 5 Maintenance/Troubleshooting
Page 28
Engineering Log
The Engineering Log monitors the performance of key sub-systems within the X26P ECD. It provides alerts if a subsystem is not performing properly and if maintenance is advisable. Any internal circuitry errors that occur inside the X26P ECD are written to this log. This information is used for diagnostics.
Time Synchronization
The ECD has a real-time clock powered by the battery pack and an internal battery as well. The ECD should keep accurate time even when the battery pack is removed.
Every time the X26P ECD is connected to EVIDENCE.com services, the system will perform a time synchronization. The conversion to local time, including adjustments to daylight savings time, are all computed by EVIDENCE Sync software. There is no need to program the X26P ECD to local time or to reprogram the ECD to daylight savings time.
NOTE: In EVIDENCE Sync Oine mode, if your computer time is incorrect, the incorrect time will be displayed in your EVIDENCE Sync-generated report.
X26P ECD Maintenance and Care
Each agency should establish a maintenance and handling program.
CAUTION
The X26P product is a sensitive piece of electronic equipment, and should be handled with care. Avoid dropping an X26P ECD. Do not use an X26P ECD that has a cracked handle.
• Check the battery pack regularly. Replace it when the battery percentage reaches 20%.
• Occasionally wipe out the X26P cartridge deployment bay with a dry cloth. Multiple cartridge rings
create carbon build-up (particularly after training courses) that should be removed.
• Secure the X26P ECD in a protective holster when the ECD is not in use.
• Function test the ECD regularly.
• Update the ECD’s rmware when updated rmware is released.
• Download your X26P ECD data to EVIDENCE.com services or your local PC at least once per quarter and
always before sending the ECD to TASER International.
• Avoid immersing the X26P ECD in water or exposing the X26P ECD to excessive moisture or water.
• See the troubleshooting guide at www.TASER.com for additional maintenance instructions.
Check expiration of TASER cartridges (5-year expiration date is listed on the base of the cartridge). Do not use an expired TASER cartridge in the eld. They should only be used for training.
Chapter 5 Maintenance/Troubleshooting
28
Page 29
Dropped or Wet X26P ECD
1 Point the ECD in a safe direction and away from your body.
2 Shift the safety switch to the down (SAFE) position.
3 Safely remove the battery pack.
4 Safely remove the TASER cartridge.
5 Let the ECD dry out.
CAUTION
Dry the X26P ECD thoroughly (at least 24 hours). Do not use an external heat source such as a microwave oven or hair dryer to dry the X26P ECD.
6 Point the ECD in a safe direction and away from your body and ensure that the safety switch to the down
(SAFE) position.
7 Safely reinstall the battery pack.
8 Shift the safety to the up (ARMED) position.
9 Look at the CID to ensure the X26P ECD is functioning properly and the CID is not showing any fault icons.
10 Press the trigger switch to test the functioning. See the instructions under Function Test for more
information.
TASER Online Troubleshooting Guide
A troubleshooting guide is available by visiting www.TASER.com. If you need product support on accessories or have any other questions, please contact customer service online at www.TASER.com or at:
U.S.: 1.800.978.2737 International: +1.800.978.2737
Product Returns
To return a TASER product for service, rst follow the procedures at www.TASER.com.
CAUTION
Always perform a complete download from the X26P ECD before returning it for RMA. Any data information will be lost during servicing work performed by TASER.
If the TASER ECD has been exposed to bodily uids or other bio-hazards, please contact the customer service department at 1.800.978.2737 for specic instructions BEFORE returning the X26P ECD.
29
Chapter 5 Maintenance/Troubleshooting
Page 30
Optional Accessories
6
EVIDENCE.com
You can upload the data from your X26P ECD to EVIDENCE.com or EVIDENCE.com Lite services. EVIDENCE.com Lite is free and allows downloading the X26P ECD, viewing the Event and Pulse logs, and updating the ECD software.
The full EVIDENCE.com pay service allows you to manage video records in addition to your ECD records. Visit www.evidence.com for details.
EVIDENCE Sync Oine Software
The EVIDENCE Sync software can be used in the Oine mode for ECD users who do not have an EVIDENCE.com account. EVIDENCE Sync Oine enables you to download the Event Log to your local computer and print it. Visit www.evidence.com or www.TASER.com for details.
TASER CAM HD Recorder
The TASER CAM HD recorder allows users to capture vital information prior to, during, and after deployment or potential deployment of the X26P ECD. The TASER CAM HD recorder is an audio-video recording device inserted into a rechargeable X26P ECD power supply that replaces the standard battery pack and is compatible with all X26P ECDs. The TASER CAM HD recorder is activated when the safety switch is in the up (ARMED) position. There is a boot-up time delay of approximately 2 seconds after the safety switch is moved to the up (ARMED) position before it starts to record.
30
Page 31
The TASER CAM HD battery is rechargeable and is capable of approximately 100 5-second rings when completely charged. Charging is accomplished through a 110-volt wall adapter through the USB cable.
The TASER CAM HD can record approximately 1 hour of video at maximum resolution before recording over previous les (continuous loop system).
Video and audio is downloaded via a USB cable and EVIDENCE Sync software to your local computer or to EVIDENCE.com services.
There also is an automatic shuto (AS) version of the TASER CAM HD recorder that emits an alarm and shuts down the energy cycle after 5 seconds, like the APPM battery pack.
Holsters
Several holsters are designed for use with the X26P ECD. Both right- and left-handed congurations are available. Visit our website at www.TASER.com for details.
31
Chapter 6 Optional Accessories
Page 32
Additional Items
7
Additional Information
New TASER brand products are under development. Visit our website at www.TASER.com for the latest information.
Material Safety Data Sheets (MSDS) for lithium batteries are available by contacting TASER International.
TASER Training Academy
The TASER Training Academy is designed to provide training on the use of TASER-brand ECDs. Training is geared toward the special needs of law enforcement ocers, correctional ocers, medical personnel, the military, professional security, and private citizens. ECD functions, medical issues, device maintenance, and personal safety are just a few of the topics covered in the oered courses.
Located at TASER’s headquarters in Scottsdale, Arizona, the TASER Training Academy features a state-of-the-art classroom facility complete with 48 work stations equipped with power and Internet access, safety mats, and the Ti Training interactive training simulator.
We “ght like we train.” It is for this reason that we emphasize hands-on, interactive and scenario-based training. Most of our courses involve some degree of physical activity and participation. We make reasonable eorts to simulate real-life stress and circumstances, to provide realistic training to better prepare the student for success in the eld. Through the use of our Ti Training interactive force simulator and Simulation Training Suits, we promote sound use of force judgment, tactics and follow up procedures.
Our cadre of instructors consists of active and former law enforcement ocers and military trainers. Many are internationally recognized experts in use of force at all levels with extensive training backgrounds.
All of our instructors are committed to providing high-level training and to forming lasting relationships to support our students long after they leave the TASER Training Academy.
For more information visit our website www.TASER.com or give us a call at 1.800.978.2737.
Courses:
• TASER Electronic Control Device Instructor Course
• TASER Online User Course
• TASER Master Instructor Course
• TASER Technician Course
• TASER Evidence Collection and Analysis Course
32
Page 33
• TASER Use of Force, Risk Management and Legal Strategies Seminar
Medical Research
TASER ECDs are among the most extensively studied force options. Numerous ECD-related medical and eld studies have been published. For more information go to www.TASER.com.
See the current product warnings, training materials, licensing agreements, and specication sheets for more information about your TASER product.
Product functions and specications may change without notice and the actual product may vary from the illustrations in this manual.
33
Chapter 7 Additional Items
Page 34
Windows® is a registered trademark of Microsoft Corporation in the United States and other countries. Windows Vista is either a
trademark or registered trademark of Microsoft Corporation in the U.S. and other countries.
M26™, TASER CAM™ HD, X2™, X26™, X26P™, XP25™, ‘Protect Life’ and © are trademarks of TASER International, Inc.,
and TASER® and X3® are registered trademarks of TASER International, Inc., registered in the U.S. © 2012 TASER International, Inc.
All rights reserved.
MMU0042 Rev: A
Loading...