Tait T800 II Reference Guide

Page 1
T800 Series Conventional Equipment
II
Reference
M800RACK-00-101
Guide
Page 2
T800 Series II Conventional Equipment
Section 1: Introduction
Guide to the Conventional T800 Equipment Questionnaire Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross-Reference Chart
Rack Components Weights Section 2: Rack Configurations Section 3: Rack Power Supply Options
Section 4: Guide Assemblies (Pending) Section 5: Rack Backplanes (Pending) Section 6: Personality Boards (Pending) Section 7: Ancillary Modules (Pending) Section 8: Modules (Pending)
3/7/00
Page 3
T800 Series Conventional Equipment
Reference Guide
II
Introduction
Page 4
T800 Series II Conventional Equipment Section 1
T800 Conventional Equipment
This publication contains relevant reference information for Tait’s T800 Conventional product range. It will be updated as equipment is modified or new features are introduced.
It is intended to show only standard options. There is provision to ‘mix & match’ up to seven modules in a rack to produce combinations for customised solutions.
Tait System Solutions are open-ended.
As well as information about the equipment there is also an order form and detailed instructions on how to fill in the orde r form.
If you cannot find a solution,
Please contact Custom Solutions.
Contact Details
Chris Quinlivan Conventional Systems Manager Alana Mehrtens Technical Illustrator
535 Wairakei Rd PO Box 1645 Christchurch New Zealand
Telephone: (64) (3) 3583399 Facsimile: (64) (3) 358 2825 E-mail: conventional.system@tait.co.nz
Copyright TEL 3/7/00
Page 5
T800 Series II Conventional Equipment Section 1
Document Control
The initial release o f this guide will be a hard copy delivered to Customer Service Organisations and other relevant people within the Tait organisation.
In the interests of im proving the performance, reliability or servicing of the equipment, Tait Electronics Limited reserve the right to update the equipment or this document or both without prior notice.
The Master copy will be available on the Tait Ele ctronics Ltd Customer Service web site.
Changes will be notified to all document holders who will be responsible for updating these changes from the web site.
Copyright TEL 3/7/00
Page 6
Guide and Purpose
for
Conventional T800 Equipment Questionnaire
The purpose of this questionnaire is to assist the staff of TEL to get as much information as possible from you at the start of your enquires or order request for equipment that is to be SET-UP BY TEL. The accurate completion of this form will speed up processing time and ensure delivery of the correct equipment.
PART 01. (WHAT IS REQUIRED)
This is to immediately identify the quantity and what sort of configuration or equipment is required.
PART 02. (FREQUENCY BAND REQUIRED
This is to indicate which frequency band the equipment is required to operate in. It also gives the equipment type required.( for Series I the last four digits are not needed). In some cases there will be a need for Transmitter and Receiver to be in different bands; this will not affect the Rackframe required.
ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE.
PART 03. (DO YOU KNOW WHAT IS REQUIRED)
The completion of this section in full is not always essential but the more information you provide will assist the Technician in correctly configuring the Rackframe to your requirements.
SPEAKER PANELS ARE FITTED AS STANDARD WHERE APPROPIATE
In the Rackframe line for part number you may put the code for the configuration required, these codes can be found in the T800 Series II Conventional Equipment Reference Guide, Section 1. If you do not have an TEL code, you may enter either the high level T number, if known. These are also in the Reference Guide, Section 2, or enter “do not know” and leave the selection of Rackframe to TEL who will select the appropriate configured Rackframe to meet your requirements, based on the rest of the information provided in this section. For the rest of the requirements, indicate the quantities required in the appropriate box for the module that you would like to be fitted into the Rackframe, remembering there is only sufficient room to fit 7 x 60mm modules. Doing this will help TEL ensure that if a Rackframe has been mentioned it can support your requirements. If no standard Rackframe exists that will fulfil your needs, then TEL can engineer a configuration to satisfy your requirements.
T800questV13.doc : Issued 6 July 2000 Page 1 of 2
Page 7
PART 04 (EQUIPMENT TYPE REQUIRED)
This is to indicate the preferred type of equipment you require, remembering that eventually all types will be Series II. Ensure type ordered are Type Approved for Country of use.
PART 05 (DO YOU KNOW THE FREQUENCIES)
This information can be helpful as sometimes the auxiliary equipment can be frequency-dependent, ie; Duplexer/Splitters, etc.
PART 06 (AUXILIARY EQUIPMENT)
The information provided in this section ensures that the auxiliary equipment asked for is appropriate for the frequency band that the rest of the equipment is to operate in.
PART 07 (ANCILLARY EQUIPMENT)
This section is to advise TEL of the maintenance support equipment required.
PART 08 (BRIEF DESCRIPTION)
This section is to enable you to give TEL a quick operational requirement and provide sketches if deemed necessary on the information sheet provided.
PART 09 (ADDITIONAL COMMENTS)
This section is to allow you to provide any extra information you think TEL will require.
PART 10
This is to inform TEL of your required delivery DATE .
PART 11 (TRANSMITTER/EXCITER PARAMETERS)
This section is to allow you to inform TEL of operational parameters for the equipment.
By ticking the STANDARD box you are indicating that all parameters required are as stated in the Set-up procedure in the appropriate equipment manual, and the frequency/frequencies required are as stated in PART 05. If no frequencies are stated in Part 05 then the equipment is to be Set-up on TEST frequencies.
By ticking the CUSTOMISED box you are indicating special requirements are needed. You must then fill in all the required details in the boxes below to allow TEL to set-up the equipment to those specifications and options, and to supply any other information that may be required by TEL.
PART 12 (RECEIVER PARAMETERS)
Same as above.
T800questV13.doc : Issued 6 July 2000 Page 2 of 2
Page 8
CONVENTIONAL T800 EQUIPMENT
Customer Information: Date:
Customer / C.S.O From: Purchase Order Number: TEL Quote Reference: TEL Staff Responsible:
This form has been devised to assist in clearly identifying the Product required, and i t s operational parameters if being BUILT and TESTED by TEL.
DO YOU REQUIRE RACKS and MODULES? DO YOU REQUIRE MODULES ONLY?
(Please continue on this page) (TEL to Set-up, Please go to PART 04)
PART 01. WHAT IS REQUIRED?
Base Station Portable Slimline To Operate as a Repeater Yes No
TOTAL QUANTITY REQUIRED :-
PART 02.
66- 88Mhz 136-156Mhz 148-174Mhz 174-225Mhz
FREQUENCY BAND REQUIRED ?
(T82n-xx-xxxx) T83n-xx-xxxx) (T83n-xx-xxxx) (T37n-xx )
220-244Mhz 243-270Mhz 330-380Mhz 400-440Mhz
(T86n-xx-xxxx) (T86n-xx-xxxx) (T87n-xx-xxxx) (T85n-xx-xxxx)
440-480Mhz 480-520Mhz 800-880Mhz 870-960Mhz
(T85n-xx-xxxx) (T85n-xx-xxxx) (T88n-xx-xxxx) (T88n-xx-xxxx)
ARE REQUIRED MODULES TYPE APPROVED,
PART 03.
DO YOU KNOW WHAT IS REQUIRED PER RACK?
Description Option Required
COUNTRY OF USE :-
Qty
( / Rack)
Part Number
Total
(Qty x No of racks)
Rackframe Receiver Transmitter Exciter
Power Amplifier
Power Supply Converter
Circuit Breaker
10Amp, 20Amp or 30Amp
50 Watts
70 / 100 Watts
AC for Volts
External 13.8V Supply
Battery
12/12, 24/12, 48/12
Alarm Unit Monitor Unit Tone Remote Combiner 200W Hi Stability Osc Channel Panel Cooling Fan
10 Channel / 100 Channel
Single or Double
Relay-50 W Max Duplexer Duplexer Cradle Blank Panel Speaker Panel
Tx/Rx Frequencies required
(T800-42-0001) (316-06615-00)
Single/selectable
Option
T800temp.V13.doc : Issued 14/07/00 Page 1 of 4
Page 9
Purchase Order Number
PART 04. EQUIPMENT TYPE REQUIRED :-
PART 05. DO YOU KNOW THE FREQUENCIES AT THIS TIME?
SERIES I SERIES II
No To be advised Attached
Yes
Tx MHz CTCSS Hz Rx MHz CTCSS Hz
Channel Panel Eprom Info To be advised Attached
PART 06.
Description OPTION REQUIRED Qty Part Number
Automatic
Changeover
Unit
PART 07. ANCILLIARY EQUIPMENT :-
Module Extender with 2 D Ranges(standard)
Module Extender with 11 way D Range(QS)
AUXILLIARY EQUIPMENT :-
For Freq:- Mhz
Power Monitor Kit
Installation Kit
Description Qty Part Number
Cabinet
Microphone
Programming Software
Service Manuals
PART 08. BRIEF DESCRIPTION : (Diagram / Information Sheet Attached?)
PART 09. ADDITIONAL COMMENTS :-
PART 10.
DATE REQUIRED
Yes No
T800temp.V13.doc : Issued 14/07/00
Page 2 of 4
Page 10
Purchase Order Number
PART 11. TRANSMITTER/EXCITER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm Tx Time Out : External Reference Disabled
Transmitter Power : Enabled
25 Watts (Max Time 5 mins) Duration Mins 50 Watts Tx Tail Time :
(For 800MHz Max 70W) 70 Watts Disabled
100 Watt s Enabled
Other Watts (Max Time 5 secs) Duration Secs
Number of Channels : Audio Response :
Single Pre-emphasised
(Freq MHz) Flat
Multiple Special Modifications
(Pattern Requir ed) No
Yes
Line Level : dBm Refer to Part 08
PART 12.
RECEIVER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm External Reference Audio Response :
Number of Channels : De-emphasised
Single Flat
(Freq MHz)
Multiple R.S.S.I. : (UHF Equipment Only)
(Pattern Required) Note:All other equipment No
has RSSI as standard Yes Special Modifications
Line Level : dBm No
Yes
Gating Operating Level : Refer to Part 08
T800temp.V13.doc : Issued 14/07/00
Page 3 of 4
Page 11
Purchase Order Number
SYSTEM BLOCK DIAGRAM (OPTIONAL)
T800temp.V13.doc : Issued 14/07/00
Page 4 of 4
Page 12
T800 Series II Conventional Equipment Section 1
T800SII Numbering System
Conventional Rack Systems ordered from RSD using the adjacent Numbering System will be configured as follows:
Rack Configuration
The Racks used in these configurations are as per Section 2 of this guide, which illustrates the factory default sp ecifications.
Each Rack is fully wired and set-up for AC or DC power supply options. (Refer to Section 3).
A Speaker / Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as required. Receiver, transmitter, PA, power supply, etc. must be ordered separately.
If the System Type is code “B”, a co-axial relay is fitted as standard. If any other code is used, then relays must be requested if required.
Module Configuration
All Rx and Ex/Tx modules are fitted with second D-ranges as Standard. ie.(T8XX-XX-0200)
All technical information on this Rack configuration is available from RSD.
Copyright TEL 3/7/00
Page 13
Order Number System
14/12/1999
System
Type
Frequency
Band
RF Output
Power
Channel Spacing
Power
Supply
Duplexer
B A 1 W D 0 0
B =
Base Station
R =
Repeater
S =
Slimline
P =
Portable
T =
Tone Remote
D =
Dual Base
Q =
Quasi-Sync
H =
HSO Rack
L =
Liberty
A = B = C = D = E =
F = G = H =
I =
J =
K =
L =
66 - 88 136 - 156 148 - 174 400 - 440 440 - 480 480 - 560 800 - 880 870 - 960 220 - 244 243 - 270 265 - 285 330 - 380
(T800-22-XXXX) (T800-22-XXXX) (T800-23-0000) (T800-25-XXXX) (T800-27-XXXX) (T800-22-001X) (T800-24-XXXX) (T800-28-XXXX) (T800-56-XXXX)
(T82x-xx)
MHz
(T83x-1x)
MHz
(T83x-2x)
MHz
(T85x-1x)
MHz
(T85x-2x)
MHz
(T85x-3x)
MHz
(T88x-1x)
MHz
(T88x-2x)
MHz
(T86x-1x)
MHz
(T86x-2x)
MHz
(T86x-3x)
MHz
(T87x-2x)
MHz
N =
12.5 kHz
M =
20 kHz
W =
25 kHz
E =
50 kHz
A =
Power Supply
(T807-10-0000) (T808-10-0000)
B =
Slimline Power Supply
D =
DC External Power supply
0 =
No Duplexer Fitted
1 =
50 Watt Duplexer Fitted
2 =
Coaxial Relay
This item code is always set to (0) for Slimline configurations.
If Duplexer item code is set to (1), then Base/Repeater/Slimline Requirement sheet must be completed.
(T807-23-0010)
Ancillary
Options
1 =
25 Watts
2 =
50 Watts
3 =
90 or 100 Watts
4 =
5 Watts
Example: BA1WD00
B =
Base Station
A =
66 -88 MHz
1 =
25 Watts
W =
25 kHz
D =
DC External Power supply Fitted
0 =
No Duplexer Fitted
0 =
No Ancillaries Fitted
0 =
No Ancillary Option
1 =
Circuit Breaker Panel
2 =
Tx/Rx Metering & Monitor Unit
3 =
Multi-Channel Panel (100 CH)
4 =
Multi-Channel Panel (10 CH)
5 =
Alarm Module
Excellence in Radio
Receiver
Communications
T800//
T800//
Sensitivity
Volume
Gating
Gate
Supply
Line level
Monitor
Off On
Monitor
Mute
Excellence in Radio
Transmitter
T800//
On
Carrier
Line
Supply
Sensitivity
Microphone
Excellence in Radio
Communications
Communications
T800//
T800//
T800//
Speaker Panel
T800//
Excellence in Radio Communications
Equipment list T825-10-0200
T826-10-0200
(T800-17-00XX) (T818-01-0000) (TA087-01-0000) (TA387-01) (TA136-02-0000)
T800-22-0000 This set-up comes complete
with all required Blank Panels and a Speaker/Programming Panel
Page 14
Rack and Function Cross-Reference Chart
Relevant
Module
T number
T8n6 -
T8n7 - T8n7 -
T8n7 - T8n7 -
Cross-
Reference
Section
2
8
8
8
Module Function
Single system
Dual system
Receive only
Transmit only 25W Transmit 50W Transmit
100W Transmit
T800 - 22 - 0x00
2
2
2
2
2
2
2
2
T800 - 22 - 0x06
2
2
2
2
T800 - 22 - 0x10
2
2
2
2
2
2
2
2
T800 - 22 - 0x11
2
2
T800 - 22 - 0x12
2
2
Superceded by T800-22-0x16 T800 - 22 - 0x13
T800 - 22 - 0x14
2
2
2
2
T800 - 22 - 0x15
2
2
2
2
T800 - 22 - 0x16
2
2
2
2
Superceded by T800-22-0x14 T800 - 22 - 0x17
T800 - 22 - 0x18
2
2
2
2
2
2
T800 - 22 - 0x20
2
2
2
2
2
2
2
2
T800 - 22 - 0x21
2
2
2
2
T800 - 22 - 0x22
2
2
2
2
T800 - 22 - 0x23
2
2
2
2
2
2
T800 - 22 - 0x24
2
2
2
2
2
2
T800 - 23 - 0000
2
2
2
2
T800 - 23 - 0001
2
2
2
2
T800 - 23 - 1001
2
2
2
2
All Power options
power options
7
Changeover interface
8
7
7
7
8
8
Circuit breaker
Optional Duplexer
Optional relay
Optional CH/PNL
T803 Remote/Alarm
Alarms (TA136)
Limited
Converter
Portable
Quasi Sync
Ext DC
2
2
AC
AC
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0 1 3
2
2
2
2
2
2
2
2
2
2
2
2
0 2
1
3
4
5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1 4
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
8
8
8
Monitor (T818)
Fylde TSC Interface
Speaker
Paging
Slimline
14/07/2000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Page 15
Module Function
Single system
T800 - 24 - 0000
2
2
T800 - 24 - 0x01
Rack and Function Cross-Reference Chart
T800 - 24 - 0x02
T800 - 24 - 0x03
T800 - 24 - 0600
T800 - 24 - 0601
T800 - 25 - 0000
T800 - 25 - 0001
T800 - 25 - 0002
T800 - 27 - 0x00
T800 - 27 - 0x01
T800 - 28 - 0x00
T800 - 29 - 0x00
T800 - 29 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 29 - 0x02
Dual system
Receive only
Transmit only 25W Transmit 50W Transmit
100W Transmit
All Power options
Limited
power options
Converter
Changeover interface
Circuit breaker
Optional Duplexer
2
2
2
2
2
2
2
Ext
DC,
Bat
2
2
2
2
2
AC, DC,
Bat
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AC,
DC
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Power Options
AC only
0
External DC only
1
2
2
2
2
2
2
2
2
2
2
1 4
2
2
2
2
2
2
AC and External DC
2
AC and Battery
3
External DC and Battery
4
AC, External DC and Battery
5
Optional relay
Optional CH/PNL
Portable
T803 Remote/Alarm
Quasi Sync
Alarms (TA136)
Speaker
Monitor (T818)
Paging
Fylde TSC Interface
Slimline
14/07/2000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Page 16
T800 SeriesII Rack and Module Weights
Weight (kg)
Rackframe
to house 2 modules 3.60 to house 3 modules 4.15 to house 4 modules 4.70 to house 5 modules 5.25 to house 6 modules 5.80 to house 7 modules 6.35
T8n5 Receiver 2.20 T8n6 Transmitter 2.05 T8n7 Exciter 2.05
50W Power Amplifier 3.20 100W Power Amplifier 3.55
T80n Power Supply 2.30 Circuit breaker 0.50 DC Converter Module 0.90
0.00
TA136 Alarm Unit 0.85 T818 Monitor 0.95 TA807 Channel Panel 0.35 TA320 Combiner 2.80 Duplexer 1.15 Duplexer Cradle 0.55 T803 Tone Remote / Alarm 1.55 T801-20 High Stability Oscillator 1.50
Portable Repeater Case
to house 3 modules (Standard) 6.00 to house 4 modules 6.15
2 Batteries (Standard) 5.60
14/07/2000
Page 17
T800 Series Conventional Equipment
Reference Guide
II
Rack
Configuration
Page 18
T800 Series II Conventional Equipment Section 2

T800-22-0x00

A standard single channel rack for repeater or base station use; up to 100 Watt output.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown) 25W - 11.25kg 50W - 14.45kg 100W - 14.80kg
NOTE:
solutions for specific req uir em ent s. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
This product offer s t he versat ility of fitting personality boards to pr ovide custom ised
Copyright TEL 3/7/00
Page 19
FRONT VIEW
T800//
Excellence in Radio Communications
Power Supply
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off On
Monitor
Mute
Speaker
Panel
Exciter
T800// T800//
Carrier
Line
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
Supply
On
Power Amplifier
FAN (OPTIONAL)
OPTIONAL
BLANK
REAR VIEW
Excellence in Radio Communications
Supply
Low forward power
High reverse power
Power
T800//
OPTIONAL
DUPLEXER
PA ReceiverExciter
T800//
Speaker Panel
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
1 2 3
+
4
-
5
FAN (OPTIONAL)
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-50-0000
FUSE
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-50-0000 BACKPLANE 1X800-90-0000 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Drawing name changed
Drawing No changed and Ref. added
4 3
Parts list added
2
Change of Title
1
Original
Version
AMM 26/11/99ABB AMM 24/8/99ABB AMM 8/3/99ABB AMM 14/12/98ABB AMM 22/10/98ABB
Drawn DateChecked
TITLE:
RACK, SNGL<100W, (OPT BD
DRAWING:
T800-22-0x00 RACKFRAME
Page 20
T800 Series II Conventional Equipment Section 2

T800-22-0x06

A 25 Watt single channel rack for repeater or link use.
Operational Characteristics
Single channel
Up to 25W Transmitter Output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
Microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
7.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 21
FRONT VIEW
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Speaker Panel
REAR VIEW
ReceiverTransmitter
Speaker
Panel
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
On
Excellence in Radio Communications
T800//
OPTIONAL
POWER
SUPPLY
Transmitter
T800//
Gate
Carrier
Line
Sensitivity
Microphone
Supply
T800-50-0000
EARTH
STUD
DC INPUT FUSE
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 4T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-50-0000 BACKPLANE 1X800-91-0005 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
3
Parts list amended
3
Optional power supply added
Drawing No changes and Ref. added
2 1
Original
Version
AMM 28/1/00ABB AMM 22/12/99ABB AMM 24/8/99ABB AMM 19/2/99ABB
Drawn DateChecked
TITLE:
DRAWING:
RACK, RPT/LK 25W
T800-22-0x06
Page 22
T800 Series II Conventional Equipment Section 2

T800-22-0x10

A single channel repeater or base station rack based on the standard T800-22-0x00, with the option of fitting a Channel Panel.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Length - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 11.25kg 50W - 14.45kg 100W - 14.80kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 23
FRONT VIEW
T800//
Excellence in Radio Communications
Power
Supply
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor
Volume
Off On
Monitor
Mute
Speaker
Panel
Exciter
T800// T800//
Carrier
Line
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
Supply
On
Power Amplifier
OPTIONAL
BLANK
REAR VIEW
Excellence in Radio Communications
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL)
T800//
OPTIONAL
DUPLEXER
PA ReceiverExciter
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
Power Supply
T800//
Overload
Standby
OPTIONAL
BLANK
On
Power
1 2 3
+
4
-
5
FAN (OPTIONAL)
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FUSE
T800-50-0001
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-50-0001 BACKPLANE CH-PNL 1X800-90-0000 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Drawing name changed
4
Drg No changed and Ref added
3
Parts list added
2
Change of Title
1
Original
Version
AMM 26/11/99ABB AMM 25/8/99ABB AMM 8/3/99ABB AMM 14/12/98ABB AMM 21/10/98ABB
Drawn DateChecked
TITLE
DRAWING:
RACK, SNGL<100W, (CH PNL
T800-22-0x10 RACKFRAME
Page 24
T800 Series II Conventional Equipment Section 2

T800-22-0x11

A Receiver only rack with alarm outputs, AC power supply and dual battery back-up connections.
Operational Characteristics
Receive only - up to 4 receivers
Speaker / Programming panel - with Receiver Speaker Select Switch
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Fans - single or double
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
17.75kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 25
FRONT VIEW
Alarm Panel
Power
PSU Fail
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
Forward
Test
Power Supply
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
Receiver
T800//
Gate
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
Gate
Speaker Panel
T800//T800//
25
16
Receiver
Speaker Select
OPTIONAL
CHANNEL
PANEL
34
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
On
Receiver
T800//
Gating
Gate
Off
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off
On
Monitor
Mute
OPTIONAL
BLANK
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
REAR VIEW
Speaker
Panel
ReceiverReceiverReceiverReceiver
Alarm
T800-50-0002 T800-50-0002
1
Output
13.8V 25A Max.
2 3
+
4
-
5
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
QTY
1T800-11-0004 RACK, FRAME ONLY, ASSEMBLED 2 BATT BACK-UP 2T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0000 GUIDE KIT T1500/300 DOUBLE 'D' 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0002 SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0002 BACKPLANE 1X800-93-0001 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
drg No changed and Ref added Original
45Frame label removed
Version
AMM 6/4/00ABB7 Cabling note added AMM 1/2/00ABB6 Modules rearranged AMM 25/8/99ABB AMM 20/10/98ABB1
AMM 22/7/99ABB
Drawn DateChecked
AMM 8/3/99ABB3 Parts list added
TITLE:
DRAWING:
RACK, RX ONLY (4RX + AL
T800-22-0x11
Page 26
T800 Series II Conventional Equipment Section 2

T800-22-0x12

Receive only rack similar to T800-22-0x11; but with no alarm outputs.
Operational Characteristics
Receive only - up to 4 receivers
Speaker / Programming panel - with Receiver Speaker Select Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Fans - single or double
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.35kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 27
FRONT VIEW
T800//
Excellence in Radio Communications
Power Supply
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Receiver
T800//
Gate
Supply
Off On
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
Speaker Panel
34
T800//
25
Gate
16
Receiver
Speaker Select
OPTIONAL CHANNEL
PANEL
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Gate
Off On
Receiver
T800//
Gating
Sensitivity
Line
level
Monitor Volume
Monitor
Mute
OPTIONAL
BLANK
Supply
Gate
Off On
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
REAR VIEW
Speaker
Panel
ReceiverReceiverReceiverReceiver
T800-50-0002 T800-50-0002
1
Output
13.8V 25A Max.
2 3
+
4
-
5
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 2T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-15-0002 SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0002 BACKPLANE 1X800-90-0001 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 8 SECTION 4 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Spk cabling note added
4
drg No changed and Ref added
3
Parts list added
2
Change of Title
1
Original
Version
AMM 6/4/00ABB AMM 25/8/99ABB AMM 8/3/99ABB AMM 14/12/98ABB AMM 20/10/98ABB
Drawn DateChecked
TITLE:
DRAWING:
RACK, RX ONLY (4RX
T800-22-0x12
Page 28
T800 Series II Conventional Equipment Section 2

T800-22-0x13

This rackframe has been superseded by T800-22-0x16.
Copyright TEL 3/7/00
Page 29
T800 Series II Conventional Equipment Section 2

T800-22-0x14

A dual 25 Watt channel rack, with AC power supply and DC battery back-up connections.
Operational Characteristics
Dual channel
25W output
Dual Speaker / Programming panel (switchable)
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Individual Speaker / Programming panels
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.05kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 30
FRONT VIEW
Excellence in Radio Communications
T800//
OPTIONAL SPEAKER
(T800-15-0000)
OPTIONAL DUPLEXER
AND/OR CHANNEL PANEL
Power Supply
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Power Supply
T800//
Overload
On
Standby
On
Power
Transmitter
T800//
Gate
Supply
Off On
Carrier
Line
Sensitivity
Microphone
Speaker Panel
T800//
O F F
RX 2
RX 1
On
Supply
AND/OR CHANNEL PANEL
O F F
OPTIONAL SPEAKER
(T800-15-0000)
OPTIONAL DUPLEXER
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
Transmitter
T800//
Gate
Carrier
Line
Sensitivity
Microphone
REAR VIEW
ReceiverTransmitter
Speaker
Panel
ReceiverTransmitter
1 2 3
+
4
-
5
T800-50-0001
DIODE
PACK
FUSE
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FUSE
T800-50-0001
BATTERY BACK-UP
QTY
TB1
REFERENCE
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP 2T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER / PROGRAM PANEL 1T800-40-0001 BLANKING BRACKET / FRONT PANEL SECTION 8 1T800-40-0000 FIXING KIT ONLY 2T800-50-0001 BACKPLANE 1X800-93-0001 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 4 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Drg name changed
4
Dual spk replaced by switched spk
Drg No changed, ref added, PA, PS moved
3 2
Parts list added, fans removed
1
Original
Version
AMM 29/11/99ABB AMM 2/9/99ABB AMM 25/8/99ABB AMM 18/3/99ABB AMM 12/1/99ABB
Drawn DateChecked
TITLE:
RACK, DUAL 2x25W, SPK SW
DRAWING:
T800-22-0x14 RACKFRAME
Page 31
T800 Series II Conventional Equipment Section 2

T800-22-0x15

A dual 25 Watt channel rack with 2 separate power supplies, one for each channel. The speaker panel can be switched between receivers.
Operational Characteristics
Dual channel
25W output
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC Not available
x = 3 AC and Battery
x = 4 External DC and Battery Not available
x = 5 AC and External DC and Battery Not available
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.6kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 32
FRONT VIEW
T800//
Power Supply
Overload
Standby
On
Power
Power Supply
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Supply
Off On
Transmitter
T800//
Gate
Carrier
Line
Sensitivity
Microphone
Supply
Speaker Panel
T800//
O F F
RX 1 RX 2
On
O F F
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Supply
Off On
Gate
T800//
Transmitter
Carrier
Line
Sensitivity
Microphone
Supply
Power Supply
T800//
Overload
On
Standby
On
Power
REAR VIEW
ReceiverTransmitter
Speaker
Panel
ReceiverTransmitter
Power Supply
1 2 3
+
4
-
5
T800-50-0001
DIODE
PACK
FUSE
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FUSE
T800-50-0001
Output
13.8V 25A Max.
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 2T800-41-0002 DOUBLE GUIDE KIT 2T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0001 BACKPLANE 1X800-22-0015 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
+
-
TB1
1 2 3 4 5
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
3
Drg name changed
Drg No changed, Ref added, Relay removed
3 2
Standard supply table added
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 3/2/99ABB AMM 12/1/99ABB
Drawn DateChecked
TITLE:
RACK, DUAL 2x25 WATT, (2 P/SUP
DRAWING:
T800-22-0x15 RACKFRAME
Page 33
T800 Series II Conventional Equipment Section 2

T800-22-0x16

A dual 50 Watt channel rackframe.
Operational Characteristics
Dual channel
50W output per channel
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
20.7kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 34
FRONT VIEW
Power Amplifier Receiver
Supply
Low forward power
High reverse power
Power
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Gate
Supply
Off On
Exciter
T800//T800//
Carrier
Line
Sensitivity
Microphone
Supply
T800//
RX 1 RX 2
On
T800//
O F F
O F F
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
REAR VIEW
ReceiverPA Exciter
Speaker
Panel
Exciter Receiver
T800// T800//
Gate
Supply
Off
On
Exciter
Carrier
Line
Sensitivity
Microphone
Supply
Power AmplifierSpeaker Panel
On
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL)FAN (OPTIONAL)
PA
EARTH
STUD
FAN
(OPTIONAL)
DC INPUT FUSE
T800-50-0001
FUSE
T800-50-0001
FAN (OPTIONAL)
TB1
The rack configuration has been changed to reduce
the risk of overheating in some environments.
The optional fans should be fitted.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 2T800-41-0002 DOUBLE GUIDE KIT 2T800-45-0000 GUIDE PA 50W KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0001 BACKPLANE 1X800-91-0002 POWER RAIL (STANDARD)
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 5 SECTION 3
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
T A I T
Radio Communications Christchurch New Zealand
3
Drg name changed
Drg No changed, Ref added, PA moved
2 1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 15/2/99ABB
Drawn DateChecked
TITLE:
RACK, DUAL 2x50W, (SPK SWITCHED)
DRAWING:
T800-22-0x16 RACKFRAME
Page 35
T800 Series II Conventional Equipment Section 2

T800-22-0x17

This rackframe has been superseded by T800-22-0x14.
Copyright TEL 3/7/00
Page 36
T800 Series II Conventional Equipment Section 2

T800-22-0x18

A dual channel rackframe suitable for Link and Repeater requirements: one 50W and one 25W channel.
Operational Characteristics
Dual channel
50W / 25W output
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
19.8kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 37
FRONT VIEW
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Power Supply
T800// T800//
Gate
Supply
Off On
Exciter
Carrier
Line
Sensitivity
Microphone
Supply
Power Amplifier
On
Supply
Low forward power
High reverse power
Power
Speaker Panel
T800//
RX 1 RX 2
FAN (OPTIONAL)
Receiver
T800//
O F F
O F F
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Supply
Off On
Gate
T800//
Transmitter
Carrier
Line
Sensitivity
Microphone
Supply
Power Supply
T800//
Overload
On
Standby
On
Power
REAR VIEW
ReceiverExciter
Speaker
Panel
PA ReceiverExciter
T800-50-0001
1
Output
13.8V 25A Max.
2 3
+
4
-
5
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FAN (OPTIONAL)
T800-50-0001
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 2T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER / PROGRAM PANEL SWITCHED 2T800-50-0001 BACKPLANE 1X800-90-0003 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
1 Original
Version
AMM 3/2/00ABB
Drawn DateChecked
TITLE:
DRAWING:
RACK, DUAL 25/50W
T800-22-0x18 RACKFRAME
Page 38
T800 Series II Conventional Equipment Section 2

T800-22-0x20

A single repeater or base station channel rack up to 100 Watt maximum output. The rack can accommodate an Rx/Tx Monitor panel and AC power input.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
Rx/Tx Monitor Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only Not Available
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery Not Available
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.2kg 50W - 15.95kg 100W - 16.3kg
NOTE: This product offers the versatility of fitt ing personality boards to provide customised solutions for specific req uir em ent s. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 39
FRONT VIEW
EARTH
STUD
T800//
Volume
Off
Rx/Tx Monitor
Power Supply
Output
13.8V 25A Max.
Supply
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
T800// T800//
Gate
Supply
Off On
TRANSMITTER
Exciter
Carrier
Line
Sensitivity
Microphone
OPTIONAL
Supply
Power Amplifier
On
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL)
OPTIONAL
BLANK PANEL
Excellence in Radio Communications
T800//
OPTIONAL
DUPLEXER
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
T800//
Power Supply
Overload
Standby
On
Power
REAR VIEW
Speaker
Panel
PA ReceiverExciter
T800-50-0000
T800-60-0000
1 2 3
+
4
-
5
FAN (OPTIONAL)
FUSE
Rx/Tx MON
T818-01-0000
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T A I T
Radio Communications Christchurch New Zealand
4
Drg name changed
3
Drg No changed, Ref added
2
Parts list added
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 8/3/99ABB AMM 12/1/99ABB
Drawn DateChecked
REFERENCE
QTY
SECTION 4
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
SECTION 4
1T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D'
SECTION 4
1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT
SECTION 4 SECTION 8
1T800-15-0000 SPEAKER / PROGRAM PANEL
SECTION 4
1T800-40-0000 FIXING KIT ONLY
SECTION 8
1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-50-0000 BACKPLANE
SECTION 5
1T800-60-0000 PERSONALITY BOARD
SECTION 6
1X800-90-0000 POWER RAIL (STANDARD)
SECTION 3
TITLE:
RACK, SNGL<100W, (MONITOR)
DRAWING:
T800-22-0x20 RACKFRAME
Page 40
T800 Series II Conventional Equipment Section 2

T800-22-0x21

A single 25 Watt repeater or base station channel rack to accommodate an Rx/Tx Monitor and rack mounted circuit breaker for protection on the DC power input.
Operational Characteristics
Single channel
25W output only
Speaker / Programming panel
Panel circuit breaker
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
(see T800-22-0x20)
(see T800-22-0x20) (see T800-22-0x20)
(see T800-22-0x20)
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
10.35kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 41
FRONT VIEW
T800//
Volume
Off
Rx/Tx Monitor
Circuit
Breaker
Supply
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor
Volume
Off On
Monitor
Mute
Speaker
Panel
Supply
Excellence in Radio Communications
T800//
On
Transmitter
T800// T800//
Carrier
Line
Sensitivity
Microphone
Excellence in Radio Communications
T800//
OPTIONAL
DUPLEXER
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
REAR VIEW
ReceiverTransmitter
Circuit Breaker
On
1
0
Off
Rx/Tx MON
Supply
12V
EARTH
STUD
DC INPUT
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-50-0000
T800-60-0000
T818-01-0000
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D' 1T800-45-0000 GUIDE PA 50W KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-17-0010 PANEL CIRCUIT BREAKER WITH 10AMP SWITCH 1T800-50-0000 BACKPLANE 1T800-60-0000 PERSONALITY BOARD 1316-06615-00 BLANKING FRONT PANEL ONLY 1X800-22-0121 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 8 SECTION 5 SECTION 6 SECTION 8 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Drg name changed
4
Drg No changed, Ref added
3
Parts list added
2
Change of Title
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 18/3/99ABB AMM 14/12/98ABB AMM 22/10/98ABB
Drawn DateChecked
TITLE:
RACK, SNGL<25W, (MONITOR)
DRAWING:
T800-22-0x21 RACKFRAME
Page 42
T800 Series II Conventional Equipment Section 2

T800-22-0x22

A single 50 Watt repeater or base station channel rack to accommodate an Rx/Tx Monitor and rack mounted circuit breaker for protection on the DC power input.
Operational Characteristics
Single channel
50W output only
Speaker / Programming panel
Panel circuit breaker
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
(see T800-22-0x20)
(see T800-22-0x20) (see T800-22-0x20)
(see T800-22-0x20)
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
14.1kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 43
FRONT VIEW
EARTH
STUD
T800//
Volume
Off
Rx/Tx Monitor
Circuit
Breaker
DC INPUT
Supply
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Speaker
Panel
T800// T800//
Gate
Supply
Off On
Exciter
Carrier
Line
Sensitivity
Microphone
Supply
Power Amplifier
On
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL)
REAR VIEW
PA ReceiverExciter
FAN (OPTIONAL)
Excellence in Radio Communications
T800// T800//
OPTIONAL
DUPLEXER
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
Rx/Tx MON
T800-50-0000
T818-01-0000
T800-60-0000
Circuit Breaker
Supply
12V
On
1
0
Off
TB1
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-17-0020 PANEL CIRCUIT BREAKER WITH 20AMP SWITCH
T A I T
Radio Communications Christchurch New Zealand
5
Drg name changed
4
Drg No changed, Ref added
3
Parts list added
2
Change of Title
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 8/3/99ABB AMM 14/12/98ABB AMM 22/10/98ABB
Drawn DateChecked
REFERENCE
QTY
SECTION 4
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
SECTION 4
1T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D'
SECTION 4
1T800-45-0000 GUIDE PA 50W KIT
SECTION 8
1T800-15-0000 SPEAKER / PROGRAM PANEL
SECTION 4
1T800-40-0000 FIXING KIT ONLY
SECTION 8
1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1
SECTION 8 SECTION 5
1T800-50-0000 BACKPLANE
SECTION 6
1T800-60-0000 PERSONALITY BOARD
SECTION 3
1X800-22-0122 POWER RAIL (STANDARD)
TITLE:
RACK, SNGL<=50W, (MONITOR)
DRAWING:
T800-22-0x22 RACKFRAME
Page 44
T800 Series II Conventional Equipment Section 2

T800-22-0x23

A single channel rack with 50 Watt maximum output, alarm outputs and AC power supply.
Operational Characteristics
Single channel
Up to 50W output
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.1kg 50W - 15.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 45
FRONT VIEW
T800//
Alarm Panel
Power
PSU Fail
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
Forward
Test
Power
Supply
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off On
Monitor
Mute
TRANSMITTER
Speaker
Panel
Exciter
T800// T800//
Carrier
Supply
Line
Sensitivity
Microphone
Power Amplifier
On
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL)
OPTIONAL
OPTIONAL
BLANK
REAR VIEW
PA
Excellence in Radio Communications
T800//
OPTIONAL
DUPLEXER
Transmitter
or Exciter
Speaker Panel
T800// T800//
OPTIONAL
CH/PNL
Receiver
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
Alarm
1 2 3
+
4
-
5
FAN
(OPTIONAL)
DIODE
PACK
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-50-0000
T800-60-0002
FUSE
Personality
Board
BATTERY BACK-UP
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-43-0000 GUIDE KIT T1500/300 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / F-PNL KIT 1T800-50-0000 BACKPLANE 1T800-60-0002 PERSONALITY BOARD + CH/PNL + ALARMS (0V) 1X800-93-0000 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 6 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
4
Drg name changed
3
Drg No changed, Ref added
2
Change personality board
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 30/3/99ABB AMM 15/2/99ABB
Drawn DateChecked
TITLE:
RACK, SNGL<100W, (ALARMS 0V)
DRAWING:
T800-22-0x23 RACKFRAME
Page 46
T800 Series II Conventional Equipment Section 2

T800-22-0x24

A single channel rack with 50 Watt maximum output, alarm outputs (LO) and AC power supply.
Operational Characteristics
Single channel
Up to 50W output
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.1kg 50W - 15.85kg
NOTE: This product offers the versatility of fitt ing personality boards to provide customised solutions for specific req uir em ent s. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 47
FRONT VIEW
T800//
Alarm Panel
Power
PSU Fail
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
Forward
Test
Power
Supply
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off On
Monitor
Mute
TRANSMITTER
Speaker
Panel
Exciter
T800// T800//
Carrier
Supply
Line
Sensitivity
Microphone
OPTIONAL
On
OPTIONAL
Power Amplifier
Supply
Low forward power
High reverse power
Power
BLANK
REAR VIEW
T800//
FAN (OPTIONAL)
OPTIONAL
DUPLEXER
PA
Transmitter
or Exciter
Excellence in Radio Communications
Speaker Panel
T800// T800//
OPTIONAL
CH/PNL
Receiver
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
Alarm
1 2 3
+
4
-
5
FAN
(OPTIONAL)
DIODE PACK
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-50-0000
T800-60-0001
FUSE
Personality
Board
BATTERY BACK-UP
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-43-0000 GUIDE KIT T1500/300 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / F-PNL KIT 1T800-50-0000 BACKPLANE 1T800-60-0001 PERSONALITY BOARD + CH/PNL + ALARMS (LO) 1X800-93-0000 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 6 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
12Original
Version
Drg name changed
AMM 29/11/99ABB AMM 7/9/99ABB
Drawn DateChecked
TITLE:
RACK, SNGL<100W, (ALARMS LO)
DRAWING:
T800-22-0x24 RACKFRAME
Page 48
T800 Series II Conventional Equipment Section 2

T800-23-0000

A single channel rack with 25 Watt maximum output mounted in a 2RU Slimline configuration for use in DC situations.
Operational Characteristics
Single channel
Up to 25W output
Speaker / Programming Port
Power Supply Options
External DC only
Configuration Options
Coaxial Relay
Microphone
Mechanical Characteristics
2 Rack Units x 19” rack to house up to 7 modules
Size
Height - 89mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W – 3.9kg
This configuration includes Receiver and Transmitter modules. (to be specified when ordering)
Copyright TEL 3/7/00
Page 49
FRONT VIEW
T800//
Receiver
Supply
Gate
Gating
Sensitivity
Line Level
Monitor Volume
On Off
REAR VIEW
Monitor
ReceiverTransmitter
Transmitter
SupplyOn
Line
MicrophoneCarrier
Sensitivity
T800II Slimline
TB
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T A I T
Radio Communications Christchurch New Zealand
1 Original
Version
AMM 20/9/99ABB
Drawn DateChecked
TITLE:
DRAWING:
QTY
REFERENCE
1T800-23-0000 SLIMLINE ASSEMBLY KIT + CABLES
SECTION 4
1T8n5-nn-nnnn RECEIVER
SECTION 8
1T8n6-nn-nnnn TRANSMITTER
SECTION 8
SLIMLINE 25W DC
T800-23-0000
Page 50
T800 Series II Conventional Equipment Section 2

T800-23-0001

A single channel rack with 25 Watt maximum output mounted in a 2RU Slimline configuration, with an AC power supply.
Operational Characteristics
Single channel
Up to 25W output
Speaker / Programming Port
Power Supply Options
AC only
Configuration Options
Coaxial Relay
Microphone
Mechanical Characteristics
2 Rack Units x 19” rack to house up to 7 modules
Size
Height - 89mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W – 8.55kg
This configuration includes Receiver and Transmitter modules. (to be specified when ordering)
.
Copyright TEL 3/7/00
Page 51
FRONT VIEW
y
T800//
Receiver
Supply
Gate
Gating
Sensitivity
Line Level
Monitor Volume
On Off
REAR VIEW
Monitor
ReceiverTransmitter
Transmitter
SupplyOn
Line
MicrophoneCarrier
Sensitivity
T800II Slimline
Power Suppl
TB
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T A I T
Radio Communications Christchurch New Zealand
1 Original
Version
AMM 20/9/99ABB
Drawn DateChecked
TITLE:
DRAWING:
QTY
REFERENCE
1T800-23-0001 SLIMLINE ASSEMBLY KIT + CABLES + POWER SUPPLY
SECTION 4
1T8n5-nn-nnnn RECEIVER
SECTION 8
1T8n6-nn-nnnn TRANSMITTER
SECTION 8
SLIMLINE 25W AC
T800-23-0001
Page 52
T800 Series II Conventional Equipment Section 2

T800-23-1001

A single channel rack, transmitter only, with 25 Watt maximum output mounted in a 2RU Slimline configuration, with an AC power supply. Suitable for use in Paging situations
Operational Characteristics
Single channel
Up to 25W output
Speaker / Programming Port
Power Supply Options
AC only
Configuration Options
Coaxial Relay
Microphone
Mechanical Characteristics
2 Rack Units x 19” rack to house up to 7 modules
Size
Height - 89mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W – 6.35kg
This configuration includes Transmitter module. (to be specified when ordering)
.
Copyright TEL 3/7/00
Page 53
FRONT VIEW
y
T800//
Paging Module
Programming
Port
Transmitter
REAR VIEW
Transmitter
SupplyOn
Line
MicrophoneCarrier
Sensitivity
T800II Slimline
Power Suppl
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T A I T
Radio Communications Christchurch New Zealand
1 Original
Version
AMM 6/3/00ABB
Drawn DateChecked
TITLE:
DRAWING:
QTY
REFERENCE
1T800-23-1001 SLIMLINE ASSEMBLY KIT + CABLES + POWER SUPPLY
SECTION 4
1T8N6-nn-1000 TRANSMITTER
SECTION 8
SLIMLINE PAGING
T800-23-1001
Page 54
T800 Series II Conventional Equipment Section 2

T800-24-0x00

A single channel Quasi Sync channel with up to 100 Watt output, AC power supply and alarm outputs.
Operational Characteristics
Quasi Sync working
Single channel
Up to 100W output
Reference Input
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0012
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.1kg 50W - 15.85kg
Rack “Items Supplied as Standard” does not include modules other than those
100W - 16.2kg
listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 55
FRONT VIEW
T800//
Alarm Panel
Power
PSU Fail
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
Forward
Test
Power
Supply
T800//
Receiver
Gating
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off On
Monitor
Mute
Speaker
Panel
Exciter
T800// T800//
Carrier
Line
Supply
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
On
Power Amplifier
OPTIONAL
BLANK
REAR VIEW
Excellence in Radio Communications
Supply
Low forward power
High reverse power
Power
T800// T800//
(KANNEL 561)
Z2
FAN (OPTIONAL)
OPTIONAL
DUPLEXER
PA ReceiverExciter
Speaker Panel
T800//
OPTIONAL
CHANNEL
PANEL
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
Alarm
1 2 3
+
4
-
5
FAN (OPTIONAL)
T800-24-0000
DIODE
PACK
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-52-0000
FUSE
REFERENCE
INPUT
BATTERY BACK-UP
QTY
TB1
REFERENCE
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP 1T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0000 GUIDE KIT T1500/300 DOUBLE 'D' 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT SECTION 4 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-52-0000 BACKPLANE 1X800-93-0000 POWER RAIL 1219-02601-00 REFERENCE LEAD
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
SECTION 4 SECTION 4 SECTION 4 SECTION 4
SECTION 8 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
5
Drg name changed
4
Drg No changed, Ref added
3
Parts list added
2
Change of Title
1
Original
Version
AMM 30/11/99ABB AMM 25/8/99ABB AMM 18/3/99ABB AMM 14/12/98ABB AMM 22/10/98ABB
Drawn DateChecked
TITLE:
RACK, QS TX<100W, (ALARM)
DRAWING:
T800-24-0x00 RACKFRAME
Page 56
T800 Series II Conventional Equipment Section 2

T800-24-0x01

Dual channel Quasi Sync rack with 50 Watt maximum output, and AC power supply.
Operational Characteristics
Quasi Sync working
Dual channel
50W output maximum
Reference Input
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0012
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
23.55kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 57
FRONT VIEW
EARTH STUD
EARTH
STUD
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
T800// T800//
Gate
Supply
Off On
Exciter
Carrier
Line
Sensitivity
Microphone
On
Supply
Supply
On
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
Power Amplifier
Supply
Low forward power
High reverse power
Power
FAN (OPTIONAL) FAN (OPTIONAL)
T800//
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Gate
Supply
Off On
Exciter
T800//T800//
Carrier
Line
Sensitivity
Microphone
REAR VIEW
FUSE 2
Power Supply
Output
13.8V 25A Max.
T800-52-0000
1 2 3
+
4
-
5
FUSE 1
REFERENCE
ReceiverExciter
INPUT
FAN (OPTIONAL)
BATTERY BACK-UP
PA ReceiverExciter
T800-52-0000
FAN (OPTIONAL)
REFERENCE
INPUT
DIODE
PACK
Power AmplifierReceiver
Supply
Low forward power
High reverse power
Power
PA
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
It is recommended that the optional fans are fitted
to reduce the risk of overheating in some
environments.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
5
T A I T
Radio Communications Christchurch New Zealand
Drg name changed
Drg No changed, Ref added
4 3
Parts list added
2
Change of Title
1
Original
Version
AMM 29/11/99ABB AMM 25/8/99ABB AMM 18/3/99ABB AMM 14/12/98ABB AMM 21/10/98ABB
Drawn DateChecked
REFERENCE
QTY
SECTION 4
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
SECTION 4
2T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
2T800-45-0000 GUIDE PA 50W KIT
SECTION 4
1T800-44-0000 T800 PS GUIDE KIT
SECTION 5
2T800-52-0000 BACKPLANE 1X800-93-0002 POWER RAIL (STANDARD)
SECTION 3
2219-02601-00 REFERENCE LEAD
TITLE:
RACK, QS TX 2x50W, ( NO ALARM)
DRAWING:
T800-24-0x01 RACKFRAME
Page 58
T800 Series II Conventional Equipment Section 2

T800-24-0x02

A single channel Quasi Sync rack with output up to 100 Watt, AC and battery power supply.
Operational Characteristics
Quasi Sync working
Single channel
Up to 100W output
Reference Input
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0012
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 10.7kg 50W - 13.9kg
Rack “Items Supplied as Standard” does not include modules other than those
100W - 14.25kg
listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 59
FRONT VIEW
T800//
Rec eiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Power Supply
T800// T800//
Gate
Supply
Off On
Exciter
Carrier
Line
Sensitivity
Microphone
QS LINK
Power Amplifier
On
Supply
Supply
Low forward power
High reverse power
Power
T800//
FAN (OPTIONAL)
DUPLEXER
Speaker Panel
O F F
RX 1 RX 2
O F F
OPTIONAL
or
CHANNEL
PANEL
T800//
Rec eiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
T800//
Gate
Supply
Off On
REAR VIEW
ReceiverTransmitter
Speaker
Panel
PA ReceiverExciter
Transmitter
Carrier
Line
Sensitivity
Microphone
Power Supply
T800//
Overload
On
Supply
Standby
On
Power
OPTIONAL
BLANK
1 2 3
+
4
-
5
T800-50-0001
EARTH
STUD
Output
13.8V 25A Max.
FUSE 2 FUSE 1
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FAN (OPTIONAL)
T800-52-0000
REFERENCE
INPUT
TB1
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-15-0003 SPEAKER / PROGRAM PANEL, SWITCHED 1T800-40-0000 FIXING KIT ONLY
1T800-50-0001 BACKPLANE 1X800-90-0003 POWER RAIL (STANDARD) SECTION 3 1219-02601-00 REFERENCE INPUT LEAD
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 8 SECTION 51T800-52-0000 BACKPLANE, RACK, QS SECTION 5
T A I T
Radio Communications Christchurch New Zealand
12Original
Version
Drg name changed
AMM 29/11/99ABB AMM 22/10/99ABB
Drawn DateChecked
TITLE:
RACK, QS TX<50W, LINK TX/RX
DRAWING:
T800-24-0x02 RACKFRAME
Page 60
T800 Series II Conventional Equipment Section 2

T800-24-0x03

A single channel Quasi Sync channel with up to 100 Watt output, and AC power supply.
Operational Characteristics
Quasi Sync working
Single channel
Up to 100W output
Reference Input
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0012
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 11.25kg 50W - 15.0kg
Rack “Items Supplied as Standard” does not include modules other than those
100W - 15.55kg
listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 61
FRONT VIEW
T800//
Excellence in Radio Communications
Power
Supply
T800//
Rec eiver
Gating
Gate
Sensitivity
Supply
Line
level
Monitor Volume
Off On
Monitor
Mute
Speaker
Panel
Exciter
T800// T800//
Carrier
Line
Supply
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
Power Amplifier
On
OPTIONAL
BLANK
REAR VIEW
Excellence in Radio Communications
T800// T800//
Supply
Low forward power
High reverse power
Power
Z2
(KANNEL 561)
FAN (OPTIONAL)
OPTIONAL
DUPLEXER
PA ReceiverExciter
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
1 2 3
+
4
-
5
FAN (OPTIONAL)
RACK TYPE AND SERIAL No
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-52-0000
WARNING
FUSE
REFERENCE
INPUT
REFER TO SECTION 3
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
QTY
SECTION 4
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP
SECTION 4
1T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT SECTION 4
SECTION 8
1T800-15-0000 SPEAKER / PROGRAM PANEL
SECTION 4
1T800-40-0000 FIXING KIT ONLY
SECTION 8
2T800-40-0001 BLANKING BRACKET / FRONT PANEL
SECTION 5
1T800-52-0000 BACKPLANE 1X800-90-0000 POWER RAIL (STANDARD)
SECTION 3
OF THE
REFERENCE GUIDE
FOR
T A I T
Radio Communications Christchurch New Zealand
1 Origin a l
Version
AMM 29/11/99ABB
Drawn DateChecked
TITLE:
RACK, QS TX <100W, (NO ALARM)
DRAWING:
T800-24-0x03 RACKFRAME
Page 62
T800 Series II Conventional Equipment Section 2

T800-24-0600

Dual channel Quasi Sync monitoring receivers, with AC power and alarm outputs.
Operational Characteristics
Quasi Sync working
Single channel
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
2 PSU + 2 Rx + Alarm – 15.1kg 2 PSU + 1 Rx + Alarm – 12.35kg 2 PSU + 2 Rx - 13.7kg 2 PSU + 1 Rx - 10.95kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 63
FRONT VIEW
Speaker Panel
T800//
OPTIONAL CHANNEL
PANEL
Power
Supply
T800//
Rec eiver
Gating
Sensitivity
Line
level
Monitor Volume
Monitor
Mute
Power Supply
Gate
Supply
Off On
Rec eiver
T800//
Gating
Gate
Sensitivity
Supply
Line level
Monitor Volume
Off On
Monitor
Mute
OPTIONAL
BLANK PANEL
Speaker Panel
T800// T800//
OPTIONAL CHANNEL
PANEL or
BLANK PANEL
REAR VIEW
Alarm
Speaker
Panel
Alarm Panel
T800//
Power
PSU Fail
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
LEFT RX: Z3
(KANNEL 503)
Forward Test
RIGHT RX: Z4
(KANNEL 567)
OPTIONAL
BLANK PANEL
Power Supply
ReceiverReceiver
Overload
Standby
On
Power Supply
T800//
Overload
Standby
On
Speaker
Panel
Power
Power
EARTH STUD
TA136-02
T800-50-0002
Output
13.8V 15A Max.
1 2
Output
3
13.8V
+
4
15A
-
5
Max.
1 2 3
+
4
-
5
OPTIONAL
T800-24-0600
BATTERY BACK -UP
TB1 TB2
PART NUMBER DESCRIPTION
BATTERY BACK -UP
DIODE
ITEMS SUPPLIED AS STANDARD
OPTIONAL
TB3
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP 1T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0000 GUIDE KIT T1500/300 DOUBLE 'D' 2T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-50-0002 BACKPLANE 2316-06615-00 BLANKING FRONT PANEL ONLY 1X80 0-24-0600 RACK KIT 1W800-24-0600 WIRING KIT
T A I T
Radio Communications Christchurch New Zealand
4 3 2 1
Version
Parts list added Alarm panel added Change of Title Original
AMM 18/3/99 AMM 20/1/99 AMM 14/12/98ABB AMM 20/10/98ABB
Drawn DateChecked
TITLE:
DRAWING:
RACK, QS TX MON AC
(2RX + 2PSU + ALARM)
T800-24-0600
Page 64
T800 Series II Conventional Equipment Section 2

T800-24-0601

Dual channel Quasi Sync monitoring receivers, with AC power .
Operational Characteristics
Quasi Sync working
Single channel
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x =
0 AC only 1 External DC only 2 AC and External DC 3 AC and Battery 4 External DC and Battery 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
2 PSU + 2 Rx – 13.7kg 2 PSU + 1 Rx – 10.95kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 65
FRONT VIEW
T800//
Speaker Panel
Power
Supply
T800//
Rec eiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Power
Supply
Excellence in Radio Communications
T800//
Gate
Supply
Off On
OPTIONAL RECEIVER
Excellence in Radio Communications
T800//
OPTIONAL
SPKR/PROG
PANEL
Excellence in Radio Communications
T800// T800//
Power Supply
Overload
Standby
On
Power
T800//
Power Supply
Overload
Standby
On
Power
REAR VIEW
Receiver
Speaker
Panel
EARTH
STUD
Output
13.8V 25A Max.
1 2
Output
3
13.8V
+
4
25A
-
5
Max.
TB2
1 2 3
+
4
-
5
TB3
MAX O/P
20A
DIODE
PACK
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-50-0002
DR1
FUSE 1
REFERENCE
INPUT
TB1
REFERENCE
QTY
SECTION 4
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
SECTION 4
1T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
2T800-44-0000 T800 PS GUIDE KIT
SECTION 8
1T800-15-0000 SPEAKER / PROGRAM PANEL
SECTION 8
1T800-40-0001 BLANK PANEL AND FIXING KIT
SECTION 82T800-40-0000 FIXING KIT ONLY SECTION 5
1T800-50-0002 BACKPLANE 1X800-24-0601 STANDARD LOOM ASSEMBLY SECTION 3 1W800-24-0601 WIRING KIT 2316-06615-00 BLANK PANEL
T A I T
Radio Communications Christchurch New Zealand
1 Origin a l
Version
AMM 22/10/99ABB
Drawn DateChecked
TITLE:
RACK, QS MON, AC (2RX + 2PSU)
DRAWING:
T800-24-0601
Page 66
T800 Series II Conventional Equipment Section 2

T800-25-0000

A single 25W channel, housed in a portable case with sealed lead acid batteries.
Operational Characteristics
Single channel
Up to 25W output
DC only operation - Batteries and external DC supply input
Speaker / Programming panel
DC line fuse
Backplane interface
Battery Isolation Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
15.85kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 67
FRONT VIEW
Receiver
T800//
Gating
Gate
Sensitivity
Supply
Line level
Monitor
Volume
Off On
Monitor
Mute
EXTERNAL DC BATTERY OPERATION
T8n5 -nn-0200 T8n6 -nn-0200
Transmitter
T800// T800//
Carrier
Line
Supply
Sensitivity
Microphone
BASE STATION REPEATER
Speaker Panel
T800//
On
TALK THROUGH
T800-15-0000
SPKR/PROG PNL
TA087-01-0000 100 CHANNEL
CHANNEL PANEL
TA387-01-0000
10 CHANNEL
CHANNEL PANEL
or
or
REAR VIEW
BATTERY ISOLATION LABEL
Duplexer mounted behind
T800-50-0001
OFF
ON
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
DC
FUSE
10A
TYPE
SER NO.
QTY
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION 1T800-41-0002 DOUBLE GUIDE KIT 1T800-40-0001 BLANK PANEL AND FIXING KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-50-0001 BACKPLANE 2290-00010-48 BATTERY SEALED LEAD ACID 12V 6.5A 1X800-25-0000 STANDARD LOOM ASSEMBLY 1W800-25-0000 WIRING LIST T800-25-0000
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 5
T A I T
Radio Communications Christchurch New Zealand
4
Reference added
3
Battery details added
2
Diode pack alignment corrected
1
Original
Version
AMM 26/8/99ABB AMM 30/6/99ABB AMM 2/6/99ABB AMM 4/3/99ABB
Drawn DateChecked
TITLE:
T800-25-0000 PORTABLE
DRAWING:
T800-25-0000
Page 68
T800 Series II Conventional Equipment Section 2

T800-25-0001

A single 25W channel, housed in a portable case with sealed lead acid batteries. This unit can use an external AC power source.
Operational Characteristics
Single channel
Up to 25W output
AC and DC operation - Batteries, external AC and DC supply input
Speaker / Programming panel
DC line fuse
Backplane interface
Battery Isolation Switch
Talk Through Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
18.3kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 69
FRONT VIEW
Receiver
T800//
Gating
Gate
Sensitivity
Supply
Line level
Monitor
Volume
Off On
Monitor
Mute
EXTERNAL DC BATTERY OPERATION
T8n5 -nn-0200 T8n6 -nn-0200
Transmitter
T800//
Carrier
Line
Sensitivity
Microphone
BASE STATION REPEATER
T800//
On
Supply
TALK THROUGH
T800-15-0000
SPKR/PROG PNL
TA087-01-0000 100 CHANNEL
CHANNEL PANEL
TA387-01-0000
10 CHANNEL
CHANNEL PANEL
Speaker Panel
or
or
REAR VIEW
T800//
BATTERY ISOLATION LABEL
Power Supply
Overload
Standby
On
Power
Duplexer mounted behind
T800-50-0001
1
Output
13.8V 25A Max.
OFF
PART NUMBER DESCRIPTION
2 3
+
4
-
5
ON
ITEMS SUPPLIED AS STANDARD
AC
I/P
DC
and
FUSE
10A
TYPE
SER NO.
SIGS
QTY
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION 1T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-50-0001 BACKPLANE 2290-00010-48 BATTERY SEALED LEAD ACID 12V 6.5A 1X800-25-0000 STANDARD LOOM ASSEMBLY 1W800-25-0000 WIRING LIST T800-25-0000
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 5
T A I T
Radio Communications Christchurch New Zealand
4
Reference added
3
Battery details added
2
Diode pack alignment corrected
1
Original
Version
AMM 26/8/99ABB AMM 30/6/99ABB AMM 1/6/99ABB AMM 5/3/99ABB
Drawn DateChecked
TITLE:
T800-25-0001 PORTABLE
DRAWING:
T800-25-0001
Page 70
T800 Series II Conventional Equipment Section 2

T800-25-0002

A single channel with up to 50W output, housed in a portable case with no batteries. This unit can use external AC or DC power source.
Operational Characteristics
Single channel
Up to 50W output
AC and DC operation - External AC and DC supply input
DC line fuse
Backplane interface
Battery Isolation Switch
Talk Through Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
25W - 12.55kg 50W - 15.9kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 71
FRONT VIEW
Receiver
T800//
Gating
Gate
Sensitivity
Supply
Line level
Monitor
Volume
Off On
Monitor
Mute
EXTERNAL DC BATTERY OPERATION
OPTIONAL BLANK
PANEL
or
OPTIONS PANEL
Exciter
T800// T800//
On
Carrier
Line
Supply
Sensitivity
Microphone
TALK THROUGH
BASE STATION REPEATER
OPTIONAL
TRANSMITTER
Power Amplifier
Supply
Low forward power
High reverse power
Power
T800-15-0000
SPKR/PROG PNL
or
TA087-01-0000
100 CHANNEL
CHANNEL PANEL
or
TA387-01-0000
10 CHANNEL
CHANNEL PANEL
REAR VIEW
Power Supply
T800//
Overload
Standby
On
Power
T800-15-0000
SPKR/PROG PNL
or TA087-01-0000 100 CHANNEL
CHANNEL PANEL
or TA387-01-0000
10 CHANNEL
CHANNEL PANEL
Duplexer mounted behind
DR1
T800-50-0001
1
Output
13.8V 25A Max.
PART NUMBER DESCRIPTION
2 3
+
4
-
5
DR2
ITEMS SUPPLIED AS STANDARD
AC
I/P
DC
I/P
FUSE
10A
TYPE
SER NO.
QTY
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION 1T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 PA (50W) GUIDE KIT 1T800-50-0001 BACKPLANE 1X800-25-0002 RACK KIT 1W800-25-0002 WIRING LIST T800-25-0002
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 5
T A I T
Radio Communications Christchurch New Zealand
12Original
Version
Reference added
AMM 26/8/99ABB AMM 4/6/99ABB
Drawn DateChecked
TITLE:
PORTABLE REPEATER <=50W
X-DC + AC (NO BATT)
DRAWING:
T800-25-0002
Page 72
T800 Series II Conventional Equipment Section 2

T800-27-0x00

A dual channel rack with 25 Watt per channel maximum output and Tone Remote / Alarm outputs.
Operational Characteristics
Dual channel
Up to 25W output
Speaker / Programming panel
Remote / Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 20.25kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 73
FRONT VIEW
EARTH
STUD
T800//
Monitor On / Off
Mode Toggle
Clear Alarms
Test (3 sec)
Remote / Alarm
Talk Through
Base Station
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Monitor Volume
Programming
Port
Power
Supply
Output
13.8V 25A Max.
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Transmitter
T800//
Gate
Supply
Off On
Carrier
Line
Sensitivity
Microphone
Supply
Remote / Alarm
T800//
Talk Through
Base Station
On
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Monitor On / Off
Monitor
Mode Toggle
Volume
Clear Alarms
Test (3 sec)
Programming
Port
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Supply
Gate
Off On
T800//
Transmitter
Carrier
Line
Sensitivity
Microphone
Supply
On
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
REAR VIEW
ReceiverTransmitter Remote
1 2 3
+
4
-
5
T800-54-0000
DR1
DIODE
PACK
FUSE
DR2
FUSE
ReceiverTransmitter Remote
PLUG SKTPLUG SKT
T800-54-0000
BATTERY BACK-UP
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-11-0004 RACK, FRAME ONLY, ASSEMBLED 2 BATT BACK-UP T800-41-0003 TRIPLE GUIDE KIT T800-44-0000 T800 PS GUIDE KIT T800-54-0000 BACKPLANE RACK REMOTE X800-93-0001 POWER RAIL (STANDARD)
T A I T
Radio Communications Christchurch New Zealand
4 3
Drg name changed
2
Drg No changed, Ref added
1
Original
Version
AMM 26/11/99ABB AMM 26/8/99ABB AMM 20/10/98ABB
Drawn DateChecked
QTY
REFERENCE
1
SECTION 4
2
SECTION 4
1
SECTION 4
2
SECTION 5
1
SECTION 3
TITLE:
RACK, DUAL 2X25W, (REMOTE
DRAWING:
T800-27-0x00 RACKFRAME
Page 74
T800 Series II Conventional Equipment Section 2

T800-27-0x01

A single channel rack with 100 Watt maximum output, Tone Remote / Alarm outputs and AC power supply.
Operational Characteristics
Single channel
Up to 100W output
Speaker / Programming panel
Remote / Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.8kg 50W - 16.55kg 100W - 16.9kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 75
FRONT VIEW
T800//
Monitor On / Off
Mode Toggle
Clear Alarms
Test (3 sec)
Remote / Alarm
Talk Through
Base Station
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Monitor
Volume
Programming
Port
Power Supply
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Gate
Supply
Off On
Exciter
T800//
Carrier
Line
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
Supply
On
Power Amplifier
OPTIONAL
BLANK
REAR VIEW
Excellence in Radio Communications
T800//
Supply
Low forward power
High reverse power
Power
FAN (optional)
PA ReceiverExciter
Excellence in Radio Communications
T800//T800//
OPTIONAL
DUPLEXER
Power Supply
T800//
Overload
Standby
On
Power
OPTIONAL
BLANK
Remote / Alarm
1 2 3
+
4
-
5
FAN
Optional
DR1
EARTH
STUD
Output
13.8V 25A Max.
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FUSE
PLUG SKT
DR2
T800-54-0000
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0003 GUIDE TRIPLE SERIESII KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 GUIDE PA 50W SERIESII KIT 2T800-40-0001 BLANKING BRACKET / FRONT PANEL 1X800-54-0000 T803-00-0000 BACKPLANE ASSEMBLY 1X800-90-0000 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
3
Drg name changed
2
Drg No changed, Ref added
1
Original
Version
AMM 26/11/99ABB AMM 26/8/99ABB AMM 1/6/99ABB
Drawn DateChecked
TITLE:
RACK, SNGL<100W, (REMOTE
DRAWING:
T800-27-0x01 RACKFRAME
Page 76
T800 Series II Conventional Equipment Section 2

T800-28-0x00

A single channel rack with 100 Watt maximum output, and provision for a High Stability Oscillator to enable the Paging function.
Operational Characteristics
Single channel - Paging
Up to 100W output
Speaker / Programming panel
High Stability Oscillator
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.75kg 50W - 16.5kg 100W - 16.85kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 77
FRONT VIEW
Excellence in Radio Communications
T800//
OPTIONAL
TRANSMITTER
Power Supply
HSO
T800//
12.8 MHz
Frequency
Adjust
10.0 MHz
OPTIONAL
BLANK
Supply
Receiver
T800//
Gating
Sensitivity
Line
level
Monitor Volume
Monitor
Mute
OPTIONAL
BLANK
Supply
Off On
Gate
Exciter
T800//
Carrier
Line
Sensitivity
Microphone
OPTIONAL
TRANSMITTER
REAR VIEW
PA ReceiverExciter
On
Supply
Power Amplifier
T800//
Supply
Low forward power
High reverse power
Power
FAN (optional)
OPTIONAL
BLANK
T800//
Excellence in Radio Communications
HSO
Power Supply
T800//
Overload
Standby
On
OPTIONAL
BLANK
Power
PLUG
DR2
T800-55-0000
DR1
EARTH
STUD
Output
13.8V 25A Max.
1 2 3
+
4
-
5
FAN
Optional
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
FUSE
QTY
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0003 GUIDE TRIPLE SERIESII KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 GUIDE PA 50W SERIESII KIT 2T800-40-0001 BLANKING BRACKET / FRONT PANEL 1T800-55-0000 BACKPLANE 1X800-90-0004 POWER RAIL (STANDARD)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION 3
T A I T
Radio Communications Christchurch New Zealand
4
Drg name changed
3
Drg No changed, Ref added
2
Speaker removed Original
1
Version
AMM 26/11/99ABB AMM 26/8/99ABB AMM 30/6/99ABB AMM 2/6/99ABB
Drawn DateChecked
TITLE:
RACK, SNGL<100W, (PAGING
DRAWING:
T800-28-0x00 RACKFRAME
Page 78
T800 Series II Conventional Equipment Section 2

T800-29-0x00

A dual channel rack with 25 Watt maximum output, to interface to Fylde Trunking Controller
Operational Characteristics
Dual channel
Up to 25W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 16.05kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 79
FRONT VIEW
Excellence in Radio Communications
T800// T800//
OPTIONAL
DUPLEXER
T800//
Receiver
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Off On
Supply
Transmitter
T800//
Gate
Carrier
Line
Sensitivity
Microphone
Supply
Speaker Panel
T800//
O F F
RX 1 RX 2
On
O F F
OPTIONAL
DUPLEXER
BEHIND SPK/PROG
PANEL
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Transmitter
T800//
Gate
Supply
Off
On
Carrier
Line
Sensitivity
Microphone
On
Supply
REAR VIEW
Power Supply
ReceiverTransmitter
Speaker
Panel
ReceiverTransmitter
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
T800-57-0000
EARTH
STUD
Output
13.8V 25A Max.
SK102 SK101
1 2 3
+
4
-
5
SK107
SK201
SK109
RV210RV211
PL101
FUSE
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
POWER RAIL (STANDARD)
T800-57-0000
FUSE
SK107
SK102 SK101
SK201
REFER TO SECTION 3
SK109
RV210RV211
OF THE
REFERENCE GUIDE
FOR
PL101
POWER RAIL OPTIONS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
TB1
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 2T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANK PANEL AND FIXING KIT 2T800-57-0000 BACKPLANE (FYLDE) 1X800-90-0001
T A I T
Radio Communications Christchurch New Zealand
Drawing name changed
12Original
Version
AMM 26/11/99ABB AMM 2/8/99ABB
Drawn DateChecked
TITLE:
RACK, DUAL 2x25W, (FYLDE
DRAWING:
T800-29-0x00 RACKFRAME
Page 80
T800 Series II Conventional Equipment Section 2

T800-29-0x01

A single channel rack with 100 Watt maximum output, to interface to Fylde Trunking Controller
Operational Characteristics
Single channel
Up to 100W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 10.7kg 50W - 14.45kg 100W - 14.8kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 81
FRONT VIEW
Excellence in Radio Communications
T800// T800//
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
T800// T800//
Gate
Supply
Off On
TRANSMITTER
Exciter
Carrier
Line
Sensitivity
Microphone
OPTIONAL
Supply
On
Power Amplifier
Supply
Low forward power
High reverse power
Power
(OPTIONAL)
FAN
OPTIONAL
BLANK
Excellence in Radio Communications
T800//
OPTIONAL
DUPLEXER
T800//
Speaker Panel
REAR VIEW
Power
Supply
Speaker
Panel
PA ReceiverExciter
Power Supply
Overload
Standby
On
Power
OPTIONAL
BLANK
EARTH
STUD
Output
13.8V 25A Max.
1 2 3
+
4
-
5
FAN
DR1
(OPTIONAL)
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-57-0000
FUSE
SK107
SK102 SK101
SK201
REFER TO SECTION 3
SK108
RV210RV211
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
PL101
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
QTY
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED 1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0001 PA (100W) GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANK PANEL AND FIXING KIT 1T800-57-0000 BACKPLANE (FYLDE) 1X800-90-0000 POWER RAIL (STANDARD)
T A I T
Radio Communications Christchurch New Zealand
12Original
Version
Drg name changed
AMM 26/11/99ABB AMM 2/8/99ABB
Drawn DateChecked
TITLE:
RACK, SNGL <=100W, (FYLDE
DRAWING:
T800-29-0x01 RACKFRAME
Page 82
T800 Series II Conventional Equipment Section 2

T800-29-0x02

A dual channel rack with 50 Watt maximum output, to interface to Fylde Trunking Controller.
Operational Characteristics
Dual channel
Up to 50W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
50W - 20.7kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing. (Receiver, transmitter, PA, power supply, etc. must be ordered separately.)
Copyright TEL 3/7/00
Page 83
FRONT VIEW
Supply
Speaker Panel
T800//
O F F
RX 1 RX 2
On
O F F
Power Amplifier Exciter
T800//
Supply
Low forward power
High reverse power
Power
FAN
(OPTIONAL)
T800//
Gating
Sensitivity
Line level
Monitor
Volume
Monitor
Mute
Off On
Gate
Supply
T800//
Exciter
Carrier
Line
Sensitivity
Microphone
T800//
Receiver
Gating
Sensitivity
Line level
Monitor Volume
Monitor
Mute
Gate
Supply
Off On
REAR VIEW
PA Exciter
Receiver
Speaker
Panel
Exciter
T800// T800//
On
Carrier
Supply
Line
Sensitivity
Microphone
FAN
Receiver
Power AmplifierReceiver
Supply
Low forward power
High reverse power
Power
(OPTIONAL)
PA
T800-57-0000
EARTH
STUD
DR1
FAN (OPTIONAL)
DR2
SK107
SK102 SK101
SK201
DC INPUT FUSE
SK108
RV210RV211
PL101
FUSE
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-57-0000
SK102 SK101
DR3
SK107
SK201
REFER TO SECTION 3
SK108
RV210RV211
FAN (OPTIONAL)
DR4
ONLY 13.8V
PL101
TB1
REFERENCE
QTY
SECTION 4
1T800-11-0004 RACK, FRAME ONLY, ASSEMBLED, 2 BATTERY BACK-UP
SECTION 4
2T800-41-0002 DOUBLE GUIDE KIT
SECTION 4
2T800-45-0000 PA (50W) GUIDE KIT
SECTION 8
1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH
SECTION 4
1T800-40-0000 FIXING KIT ONLY
SECTION 5
2T800-57-0000 BACKPLANE (FYLDE) 1X800-91-0002 POWER RAIL (STANDARD)
SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
OUTPUT
MAX
2 AMPS
T A I T
Radio Communications Christchurch New Zealand
3
Drg name changed
2
Drg No changed, Ref added
1
Original
Version
AMM 26/11/99ABB AMM 31/8/99ABB AMM 3/8/99ABB
Drawn DateChecked
TITLE:
RACK, DUAL 2x50W, (FYLDE
DRAWING:
T800-29-0x02 RACKFRAME
Page 84
T800 Series Conventional Equipment
Reference Guide
II
Rack
Power Supply
Options
Page 85
T800 Series II Conventional Equipment Section 2
Power Supply Options
This section details the Power Supply Options for T800 SeriesII Conventional rackframes. The power rails have been standardised to allow versatility in the rack applications.
Not all options are available on every rack. Please contact TEL if you are unsure of the correct option.
Baan Codes
X800-90-0000RAIL<=100W,ACfor1supply X800-91-0000RAIL<=100W,AC+X-DCfor1supply X800-92-0000RAIL<=100W,ACfor1supply X800-93-0000RAIL<=100W,AC+BATfor1supply X800-94-0000RAIL<=100W,X-DC+BATfor1supply X800-95-0000RAIL<=100W,AC+X-DC+BATfor1supply
X800-90-0001RAIL,2x25W,ACfor2supply X800-91-0001RAIL,2x25W,AC+X-DCfor2supply X800-92-0001RAIL,2x25W,ACfor2supply X800-93-0001RAIL,2x25W,AC+BATfor2supply X800-94-0001RAIL,2x25W,X-DC+BATfor2supply X800-95-0001RAIL,2x25W,AC+X-DC+BATfor2supply
X800-90-0002RAIL,2x50W,ACfor2supply X800-91-0002RAIL,2x50W,AC+X-DCfor2supply X800-92-0002RAIL,2x50W,ACfor2supply X800-93-0002RAIL,2x50W,AC+BATfor2supply X800-94-0002RAIL,2x50W,X-DC+BATfor2supply X800-95-0002RAIL,2x50W,AC+X-DC+BATfor2supply
X800-90-0003RAIL,COMBI,ACfor2supply X800-91-0003RAIL,COMBI,AC+X-DCfor2supply X800-92-0003RAIL,COMBI,ACfor2supply X800-93-0003RAIL,COMBI,AC+BATfor2supply X800-94-0003RAIL,COMBI,X-DC+BATfor2supply X800-95-0003RAIL,COMBI,AC+X-DC+BATfor2supply
Copyright TEL 14/07/00
Page 86
Power Rails Numbering System
10/07/2000
System
Type
0 =
AC only
1 =
External DC only
2 =
AC and External DC
3 =
AC and Battery
4 =
External DC and Battery
5 =
AC, External DC and Battery
Power
Rail
9 0 0 0 y
Input
Supply
Output Supply
-x-T800
0 =
1 supply, up to 100 Watts
1 =
2 supplies, up to 25 Watts/channel
2 =
2 supplies, up to 50 Watts/channel
3 =
2 supplies, combination 50W / 25W
Page 87
AC POWER SUPPLY ONLY
X800 - 90 - 0000
x = 0
x = 1
x = 2
EARTH
STUD
EARTH
STUD
EARTH
STUD
EXTERNAL DC SUPPLY ONLY
X800 - 91 - 0000
DC INPUT FUS E
AC POWER SUPPLY AND EXTERNAL DC
X800 - 92 - 0000
DC INPUT FUS E
DIODE
PACK
FUSE
TB1
TB1
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
x = 3
x = 4
x = 5
EARTH
STUD
EARTH
STUD
EARTH
STUD
AC POWER SUPPLY AND BATTERY
X800 - 93 - 0000
DIODE
PACK
FUSE
OPTIONAL POSITION
BATTERY BACK-UP
EXTERNAL DC AND BATTERY
X800 - 94 - 0000
DC INPUT FUSE
DIODE
PACK
OPTIONAL POSITION
BATTERY BACK-UP
AC POWER SUPPLY EXTERNAL DC AND BATTERY
X800 - 95 - 0000
DC INPUT FUSE
DIODE
PACK
OPTIONAL POSITION
BATTERY BACK-UP
TB1
TB1
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
OUTPUT
ONLY 13.8V
MAX
2 AMPS
T A I T
Radio Communications Christchurch New Zealand
Diode position changed
12Original
Version
AMM 26/10/99ABB AMM 8/9/99ABB
Drawn DateChecked
TITLE:
X800 - 9x - 0000
POWER RAIL OPTIONS for T800 RACKS
DRAWING:
power rails.vsd
Page 88
T800 Series Conventional Equipment
Reference Guide
II
Guide
Assemblies
Page 89
T800 Series Conventional Equipment
Reference Guide
II
Rack
Backplanes
Page 90
T800 Series Conventional Equipment
Reference Guide
II
Personality
Boards
Page 91
T800 Series Conventional Equipment
Reference Guide
II
Ancillary Modules
Page 92
T800 Series Conventional Equipment
Reference Guide
II
Modules
Loading...