Tait T800 - 22 - 0x00, T800 - 22 - 0x14, T800 - 22 - 0x10, T800 - 22 - 0x12, T800 - 22 - 0x15 Reference Manual

...
T800 Series
II
Conventional Equipment
Reference
Guide
M800RACK-00-100
Copyright TEL 30/8/99
Index
Section 1: Introduction
Guide to the Conventional T800 Equipment Questionnaire Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross-Reference Chart
Rack Components Weights Section 2: Rack Configurations Section 3: Rack Power Supply Options Section 4: Guide Assemblies Section 5: Rack Backplanes Section 6: Personality Boards Section 7: Ancillary Modules Section 8: Modules
T800 Series
II
Conventional Equipment
Reference Guide
Introduction
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
T800 Conventional Equipment
This publication contains relevant reference information for Tait’s T800 Conventional product range. It will be updated as equipment is modified or new features are introduced.
It is intended to show only standard options. There is provision to ‘mix & match’ up to seven modules in a rack to produce combinations for customised solutions.
Tait System Solutions are open-ended.
As well as information about the equipment there is also an order form and detailed instructions on how to fill in the order form.
If you cannot find a solution,
Please contact RSD Custom Solutions.
Contact Details
Chris Quinlivan Conventional Systems Manager Alex Brunton Systems Consultant Alana Mehrtens Technical Illustrator
535 Wairakei Rd PO Box 1645 Christchurch New Zealand
Telephone: (64) (3) 3583399 Facsimile: (64) (3) 358 2825 E-mail: conventional.system@tait.co.nz
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
Document Control
The initial release of this guide will be a hard copy delivered to Customer Service Organisations and other relevant people within the Tait organisation.
In the interests of imp roving the performance, re liability or servicing of the equipment, Tait Electronics Limited reserve the right to update the equipment or this document or both without prior notice.
The Master copy will be available on the Tait Electro nics Ltd Customer Service web site.
Changes will be notified to all document holders who will be responsible for updating these changes from the web site.
T800questV6.doc : Issued 25 Aug 1999 Page 1 of 3
Guide and Purpose of Filling out Conventional T800 Equipment
Questionnaire
The purpose of this questionnaire is to assist the staff of RSD to get as much information as possible from you at the start of your enquires or order request for equipment that is to be SET-UP BY RSD. The accurate completion of this form will speed up processing time and ensure delivery of the correct equipment.
PART 01. (WHAT IS REQUIRED)
This is to immediately identify the quantity and what sort of configuration or equipment is required.
PART 02. (FREQUENCY BAND REQUIRED
This is to indicate which frequency band the equipment is required to operate in. It also gives the equipment type required.( for Series I the last four digits are not needed). In some cases there will be a need for Transmitter and Receiver to be in different bands; this will not affect the Rackframe required.
ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE.
PART 03. (DO YOU KNOW WHAT IS REQUIRED)
The completion of this section in full is not always essential but the more information you provide will assist the Technician in correctly configuring the Rackframe to your requirements.
SPEAKER PANELS ARE FITTED AS STANDARD WHERE APPROPIATE
In the Rackframe line for part number you may put the code for the configuration required, these codes can be found in the T800 Series II Conventional Equipment Reference Guide, Section 1. If you do not have an RSD code, you may enter either the high level T number, if known. These are also in the Reference Guide, Section 2, or enter “do not know” and leave the selection of Rackframe to RSD who will select the appropriate configured Rackframe to meet your requirements, based on the rest of the information provided in this section.
T800questV6.doc : Issued 25 Aug 1999 Page 2 of 3
For the rest of the requirements you may tick the appropriate YES box for the module that you would like to be fitted into the Rackframe, remembering there is only sufficient room to fit 7 x 60mm modules. Doing this will help RSD ensure that if a Rackframe has been mentioned it can support your requirements. If no standard Rackframe exists that will fulfil your needs, then RSD will engineer a configuration to satisfy your requirements.
PART 04 (EQUIPMENT TYPE REQUIRED)
This is to indicate the preferred type of equipment you require, remembering that eventually all types will be Series II. Ensure type ordered are Type Approved for Country of use.
PART 05 (DO YOU KNOW THE FREQUENCIES)
This information can be helpful as sometimes the auxiliary equipment can be frequency dependant, ie; Duplexer/Splitters, etc..
PART 06 (AUXILLIARY EQUIPMENT)
The information provided in this section ensures that the auxiliary equipment asked for is appropriate for the frequency band that the rest of the equipment is to operate in.
PART 07 (ANCILLIARY EQUIPMENT)
This section is to advise RSD of the maintenance support equipment required.
PART 08 (BRIEF DESCRIPTION)
This section is to enable you to give RSD a quick operational requirement and provide sketches if deemed necessary on the information sheet provided.
PART 09 (ADDITIONAL COMMENTS)
This section is to allow you to provide any extra information you think RSD will require.
T800questV6.doc : Issued 25 Aug 1999 Page 3 of 3
PART 10
This is to inform RSD of your required delivery DATE .
PART 11 (TRANSMITTER/EXCITER PARAMETERS)
This section is to allow you to inform RSD of operational parameters for the equipment.
By ticking the STANDARD box you are indicating that all parameters required are as stated in the Set-up procedure in the appropriate equipment manual, and the frequency/frequencies required are as stated in PART 05. If no frequencies are stated in Part 05 then the equipment is to be Set-up on TEST frequencies.
By ticking the CUSTOMISED box you are indicating special requirements are needed. You must then fill in all the required details in the boxes below to allow RSD to set-up the equipment to those specifications and options, and to supply any other information that may be required by RSD.
PART 12 (RECEIVER PARAMETERS)
Same as above.
T800temp.V11.doc : Issued 09 Sept 1999 Page 1 of 4
This form has been devised to assist in clearly i denti fying the Product required, and its operational parameters i f being BUILT and TESTED by RSD.
DO YOU REQUIRE RACKS and MODULES? DO YOU REQUIRE MODULES ONLY?
(Please continue on this page) (RSD to Set-up, Please go to PART 04)
PART 01. WHAT IS REQUIRED?
Base Station Portable Slimline To Operate as a Repeater Yes No
TOTAL QUANTITY REQUIRED :-
PART 02.
FREQUENCY BAND REQUI RED ?
66- 88Mhz
(T82n-xx-xxxx)
220-244Mhz
(T86n-xx-xxxx)
440-480Mhz
(T85n-xx-xxxx)
136-156Mhz
T83n-xx-xxxx)
243-270Mhz
(T86n-xx-xxxx)
480-520Mhz
(T85n-xx-xxxx)
148-174Mhz
(T83n-xx-xxxx)
330-380Mhz
(T87n-xx-xxxx)
800-880Mhz
(T88n-xx-xxxx)
174-225Mhz
(T37n-xx )
400-440Mhz
(T85n-xx-xxxx)
870-960Mhz
(T88n-xx-xxxx)
ARE REQUIRED MODULES TYPE APPROVED, COUNTRY OF USE :- PART 03.
DO YOU KNOW WHAT IS REQUIRED PER RACK?
Description Option Required Qty Part Number
Rackframe
Receiver
Transmitter
Exciter
50 WattsPower Amplifier
70 / 100 Watt s
AC for Volts
External 13.8V Supply
Power Supply
Battery
Converter 12/12, 24/12, 48/12
Circuit Breaker 10Amp, 20Amp or 30Amp
Alarm Unit
Monitor Unit
Tone Remote
Combiner 200W
Hi Stability Osc
Channel Panel 10 Channel / 100 Channel
Cooling Fan Single or Double
Relay-50 W Max
Duplexer Tx/Rx Frequencies required
Duplexer Cradle (T800-42-0001)
Blank Panel (316-06615-00)
Speaker Panel Single/ selectable
CONVENTIONAL T800 EQUIPMENT
Customer Information: Date:
Customer / C.S.O From: Purchase Order Number: RSD Quote Reference: RSD Staff Responsible:
T800temp.V11.doc : Issued 09 Sept 1999 Page 2 of 4
PART 04. EQUIPMENT TYPE REQUIRED :- SERIES I SERIES II
PART 05. DO YOU KNOW THE FREQUENCIES AT THIS TIME?
No To be advised Attached
Yes
Tx MHz CTCSS Hz
Rx MHz CTCSS Hz
Channel Panel Eprom Info To be advised Attached
PART 06.
AUXILLIARY EQUIPMENT :-
Description OPTION REQUIRED Qty Part Number
For Freq:- Mhz
Power Monitor Kit
Automatic
Changeover
Unit
Installation Kit
PART 07. ANCILLIARY EQUIPMENT :-
Description Qty Part Number
Cabinet
Microphone
Programming Software
Module Extender with 2 D Ranges(standard)
Module Extender with 11 way D Range(QS)
Service Manuals
PART 08. BRIEF DESCRIPTION : (Diagram / Info rmat i on Sheet Attached?) Yes No
PART 09. ADDITIONAL COMMENTS :-
PART 10.
DATE REQUIRED
Purchase Order Number:
T800temp.V11.doc : Issued 09 Sept 1999 Page 3 of 4
PART 11. TRANSMITTER/EXCITER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm Tx Time Out : External Reference Disabled
Transmitter Power : Enabled
25 Watts (Max Time 5 mins) Duration Mins 50 Watts Tx Tail Time :
(For 800MHz Max 70W) 70 Watts Disabled
100 Watts Enabled
Other Watts (Max Time 5 secs) Duration Secs
Number of Channels : Audio Response :
Single Pre-emphasised
(Freq MHz) Flat
Multiple Special Modifications
(Pattern Required) No
Yes
Line Level : dBm Refer to Part 08
PART 12. RECEIVER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm External Reference Audio Response :
Number of Channels : De-emphasised
Single Flat
(Freq MHz)
Multiple R.S.S.I. : (UHF Equipment Only)
(Pattern Required) Note:All other equipment No
has RSSI as standard Yes Special Modifications
Line Level : dBm No
Yes
Gating Operating Level : Refer to Part 08
Purchase Order Number:
T800temp.V11.doc : Issued 09 Sept 1999 Page 4 of 4
SYSTEM BLOCK DIAGRAM (OPTIONAL)
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
T800SII Numbering System
Conventional Rack Systems ordered from RSD using the adjacent Numbering System will be configured as follows:
Rack Configuration
The Racks used in these configurations are as per Section 2 of this guide, which illustrates the factory default spe cifications.
Each Rack is fully wired and set-up for AC or DC power supply options. (Refer to Section 3).
A Speaker / Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as required.
If the System Type is code “B”, a co-axial relay is fitted as standard. If any other code is used, then relays must be requested if required.
Module Configuration
All Rx and Ex/Tx modules are fitted with second D-ranges as Standard. ie.(T8XX-XX-0200)
All technical information on this Rack configuration is available from RSD.
Order Number System
14/12/1999
B A 1 W D 0 0
System
Type
Frequency
Band
RF Output
Power
Channel Spacing
Power
Supply
Duplexer
Ancillary
Options
B = R = S = P = T = D =
Q =
H =
L =
Base Station Repeater Slimline Portable Tone Remote Dual Base Quasi-Sync HSO Rack Liberty
(T800-22-XXXX) (T800-22-XXXX) (T800-23-0000) (T800-25-XXXX) (T800-27-XXXX) (T800-22-001X) (T800-24-XXXX) (T800-28-XXXX) (T800-56-XXXX)
A =
B = C = D = E =
F =
G =
H =
I =
J =
K =
L =
66 - 88 136 - 156 148 - 174 400 - 440 440 - 480 480 - 560 800 - 880 870 - 960 220 - 244 243 - 270 265 - 285 330 - 380
(T82x-xx) (T83x-1x) (T83x-2x) (T85x-1x) (T85x-2x) (T85x-3x) (T88x-1x) (T88x-2x) (T86x-1x) (T86x-2x) (T86x-3x) (T87x-2x)
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
1 = 2 = 3 = 4 =
25 Watts 50 Watts 90 or 100 Watts 5 Watts
0 = 1 = 2 = 3 = 4 = 5 =
No Ancillary Option Circuit Breaker Panel Tx/Rx Metering & Monitor Unit Multi-Channel Panel (100 CH) Multi-Channel Panel (10 CH) Alarm Module
(T800-17-00XX) (T818-01-0000) (TA087-01-0000) (TA387-01) (TA136-02-0000)
0 = 1 = 2 =
No Duplexer Fitted 50 Watt Duplexer Fitted Coaxial Relay
This item code is always set to (0) for Slimline configurations.
If Duplexer item code is set to (1), then Base/Repeater/Slimline Requirement sheet must be completed.
A = B =
D =
Power Supply Slimline Power Supply
DC External Power supply
(T807-10-0000) (T808-10-0000) (T807-23-0010)
Example: BA1WD00
Receiver
T800//
Line level
Suppl
y
Monitor Volume
Monitor
Mute
Off On
Gatin
g
Sensitivit
y
Gate
Transmitter
Line
Sensitivit
y
Suppl
y
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800//
Speaker Panel
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
B = A =
1 =
W =
D =
0 = 0 =
Base Station 66 -88 MHz 25 Watts 25 kHz DC External Power supply Fitted No Duplexer Fitted No Ancillaries Fitted
N =
M =
W =
E =
12.5 kHz 20 kHz 25 kHz 50 kHz
Equipment list T825-10-0200
T826-10-0200 T800-22-0000
This set-up comes complete with all required Blank Panels and a Speaker/Programming Panel
X800-9x-000y
X800-9x-000y
X800-9x-000y
T8n7 - T8n7 -
T8n7 - T8n7 -
T8n6 -
Relevant Module
T number
8
8
8
8
8
7
7
7
7
8
7
Refer to
Sections 2&3
Options
shown.
Default Power
8
8
8
2
Cross-
Reference
Section
01/12/1999
Slimline
Fylde TSC Interface
Paging
Monitor (T818)
Speaker
Alarms (TA136)
Quasi Sync
Link
T803 Remote/Alarm
Portable
Optional CH/PNL
Optional relay
Optional fan
Optional Duplexer
Circuit breaker
Converter
Battery back-up
External 13.8V DC
AC
100W Transmit
50W Transmit
25W Transmit
Receive only
Dual system
Single system
Module Function
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x06
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x10
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x11
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x12
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x14
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x15
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x16
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x17
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x20
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x21
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x22
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x23
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x24
2
2
2
2
2
2
2
2
T800 - 23 - 0x00
2
2
2
2
2
2
2
2
T800 - 23 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x02
Rack and Function Cross-Reference Chart
01/12/1999
Slimline
Fylde TSC Interface
Paging
Monitor (T818)
Speaker
Alarms (TA136)
Quasi Sync
Link
T803 Remote/Alarm
Portable
Optional CH/PNL
Optional relay
Optional fan
Optional Duplexer
Circuit breaker
Converter
Battery back-up
External 13.8V DC
AC
100W Transmit
50W Transmit
25W Transmit
Receive only
Dual system
Single system
Module Function
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0001
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0002
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 27 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 27 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 28 - 0x00
2
2
2
2
2
2
2
2
2
2
T800 - 29 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 29 - 0x01
2
2
2
2
2
2
2
2
T800 - 29 - 0x02
Rack and Function Cross-Reference Chart
T800 SeriesII Rack and Module Weights
Weight (kg)
0.00
Rackframe
to house 2 modules 3.60 to house 3 modules 4.15 to house 4 modules 4.70 to house 5 modules 5.25 to house 6 modules 5.80 to house 7 modules 6.35
T8n5 Receiver 2.20 T8n6 Transmitter 2.05 T8n7 Exciter 2.05
50W Power Amplifier 3.20 100W Power Amplifier 3.55
T80n Power Supply 2.30 Circuit breaker 0.50 DC Converter Module 0.90
TA136 Alarm Unit 0.85 T818 Monitor 0.95 TA807 Channel Panel 0.35 TA320 Combiner 2.80 Duplexer 1.15 Duplexer Cradle 0.55 T803 Tone Remote / Alarm 1.55 T801-20 High Stability Oscillator 1.50
Portable Repeater Case
to house 3 modules (Standard) 6.00 to house 4 modules 6.15
2 Batteries (Standard) 5.60
01/12/1999
T800 Series
II
Conventional Equipment
Reference Guide
Rack
Configuration
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x00
A standard single channel rack for repeater or base station use; up to 100 Watt output.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” ra ck to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown) 25W - 11.25kg 50W - 14.45kg 100W - 14.80kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x00 RACKFRAME
TITLE:
RACK, SNGL<100W, (OPT BD
Drawn DateChecked
AMM 22/10/98ABB
AMM 24/8/99ABB
AMM 14/12/98ABB
AMM 8/3/99ABB
AMM 26/11/99ABB
Version
1
4
2
3
5
Original
Drawing No changed and Ref. added
Change of Title
Parts list added
Drawing name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Speaker Panel
T800//
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
FAN (OPTIONAL)
OPTIONAL
BLANK
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE 1X800-90-0000 POWER RAIL (STANDARD)
1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
PA ReceiverExciter
T800-50-0000
Speaker
Panel
FAN (OPTIONAL)
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x06
A 25 Watt single channel rack for repeater or link use.
Operational Characteristics
Single channel
Up to 25W Transmitter Output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
Microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
7.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x06
TITLE:
RACK, REPEATER/LINK END DC
Drawn DateChecked
AMM 19/2/99ABB
AMM 24/8/99ABB
Version
12Original
Drawing No changes and Ref. added
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Speaker Panel
T800//
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
FRONT VIEW
REAR VIEW
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE 1X800-91-0000 POWER RAIL (STANDARD)
1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
SECTION 4
REFERENCE
SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
EARTH
STUD
DC INPUT FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
ReceiverTransmitter
T800-50-0000
Speaker
Panel
Loading...
+ 51 hidden pages