Tait T800 - 22 - 0x00, T800 - 22 - 0x14, T800 - 22 - 0x10, T800 - 22 - 0x12, T800 - 22 - 0x15 Reference Manual

...
Page 1
T800 Series
II
Conventional Equipment
Reference
Guide
M800RACK-00-100
Page 2
Copyright TEL 30/8/99
Index
Section 1: Introduction
Guide to the Conventional T800 Equipment Questionnaire Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross-Reference Chart
Rack Components Weights Section 2: Rack Configurations Section 3: Rack Power Supply Options Section 4: Guide Assemblies Section 5: Rack Backplanes Section 6: Personality Boards Section 7: Ancillary Modules Section 8: Modules
Page 3
T800 Series
II
Conventional Equipment
Reference Guide
Introduction
Page 4
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
T800 Conventional Equipment
This publication contains relevant reference information for Tait’s T800 Conventional product range. It will be updated as equipment is modified or new features are introduced.
It is intended to show only standard options. There is provision to ‘mix & match’ up to seven modules in a rack to produce combinations for customised solutions.
Tait System Solutions are open-ended.
As well as information about the equipment there is also an order form and detailed instructions on how to fill in the order form.
If you cannot find a solution,
Please contact RSD Custom Solutions.
Contact Details
Chris Quinlivan Conventional Systems Manager Alex Brunton Systems Consultant Alana Mehrtens Technical Illustrator
535 Wairakei Rd PO Box 1645 Christchurch New Zealand
Telephone: (64) (3) 3583399 Facsimile: (64) (3) 358 2825 E-mail: conventional.system@tait.co.nz
Page 5
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
Document Control
The initial release of this guide will be a hard copy delivered to Customer Service Organisations and other relevant people within the Tait organisation.
In the interests of imp roving the performance, re liability or servicing of the equipment, Tait Electronics Limited reserve the right to update the equipment or this document or both without prior notice.
The Master copy will be available on the Tait Electro nics Ltd Customer Service web site.
Changes will be notified to all document holders who will be responsible for updating these changes from the web site.
Page 6
T800questV6.doc : Issued 25 Aug 1999 Page 1 of 3
Guide and Purpose of Filling out Conventional T800 Equipment
Questionnaire
The purpose of this questionnaire is to assist the staff of RSD to get as much information as possible from you at the start of your enquires or order request for equipment that is to be SET-UP BY RSD. The accurate completion of this form will speed up processing time and ensure delivery of the correct equipment.
PART 01. (WHAT IS REQUIRED)
This is to immediately identify the quantity and what sort of configuration or equipment is required.
PART 02. (FREQUENCY BAND REQUIRED
This is to indicate which frequency band the equipment is required to operate in. It also gives the equipment type required.( for Series I the last four digits are not needed). In some cases there will be a need for Transmitter and Receiver to be in different bands; this will not affect the Rackframe required.
ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE.
PART 03. (DO YOU KNOW WHAT IS REQUIRED)
The completion of this section in full is not always essential but the more information you provide will assist the Technician in correctly configuring the Rackframe to your requirements.
SPEAKER PANELS ARE FITTED AS STANDARD WHERE APPROPIATE
In the Rackframe line for part number you may put the code for the configuration required, these codes can be found in the T800 Series II Conventional Equipment Reference Guide, Section 1. If you do not have an RSD code, you may enter either the high level T number, if known. These are also in the Reference Guide, Section 2, or enter “do not know” and leave the selection of Rackframe to RSD who will select the appropriate configured Rackframe to meet your requirements, based on the rest of the information provided in this section.
Page 7
T800questV6.doc : Issued 25 Aug 1999 Page 2 of 3
For the rest of the requirements you may tick the appropriate YES box for the module that you would like to be fitted into the Rackframe, remembering there is only sufficient room to fit 7 x 60mm modules. Doing this will help RSD ensure that if a Rackframe has been mentioned it can support your requirements. If no standard Rackframe exists that will fulfil your needs, then RSD will engineer a configuration to satisfy your requirements.
PART 04 (EQUIPMENT TYPE REQUIRED)
This is to indicate the preferred type of equipment you require, remembering that eventually all types will be Series II. Ensure type ordered are Type Approved for Country of use.
PART 05 (DO YOU KNOW THE FREQUENCIES)
This information can be helpful as sometimes the auxiliary equipment can be frequency dependant, ie; Duplexer/Splitters, etc..
PART 06 (AUXILLIARY EQUIPMENT)
The information provided in this section ensures that the auxiliary equipment asked for is appropriate for the frequency band that the rest of the equipment is to operate in.
PART 07 (ANCILLIARY EQUIPMENT)
This section is to advise RSD of the maintenance support equipment required.
PART 08 (BRIEF DESCRIPTION)
This section is to enable you to give RSD a quick operational requirement and provide sketches if deemed necessary on the information sheet provided.
PART 09 (ADDITIONAL COMMENTS)
This section is to allow you to provide any extra information you think RSD will require.
Page 8
T800questV6.doc : Issued 25 Aug 1999 Page 3 of 3
PART 10
This is to inform RSD of your required delivery DATE .
PART 11 (TRANSMITTER/EXCITER PARAMETERS)
This section is to allow you to inform RSD of operational parameters for the equipment.
By ticking the STANDARD box you are indicating that all parameters required are as stated in the Set-up procedure in the appropriate equipment manual, and the frequency/frequencies required are as stated in PART 05. If no frequencies are stated in Part 05 then the equipment is to be Set-up on TEST frequencies.
By ticking the CUSTOMISED box you are indicating special requirements are needed. You must then fill in all the required details in the boxes below to allow RSD to set-up the equipment to those specifications and options, and to supply any other information that may be required by RSD.
PART 12 (RECEIVER PARAMETERS)
Same as above.
Page 9
T800temp.V11.doc : Issued 09 Sept 1999 Page 1 of 4
This form has been devised to assist in clearly i denti fying the Product required, and its operational parameters i f being BUILT and TESTED by RSD.
DO YOU REQUIRE RACKS and MODULES? DO YOU REQUIRE MODULES ONLY?
(Please continue on this page) (RSD to Set-up, Please go to PART 04)
PART 01. WHAT IS REQUIRED?
Base Station Portable Slimline To Operate as a Repeater Yes No
TOTAL QUANTITY REQUIRED :-
PART 02.
FREQUENCY BAND REQUI RED ?
66- 88Mhz
(T82n-xx-xxxx)
220-244Mhz
(T86n-xx-xxxx)
440-480Mhz
(T85n-xx-xxxx)
136-156Mhz
T83n-xx-xxxx)
243-270Mhz
(T86n-xx-xxxx)
480-520Mhz
(T85n-xx-xxxx)
148-174Mhz
(T83n-xx-xxxx)
330-380Mhz
(T87n-xx-xxxx)
800-880Mhz
(T88n-xx-xxxx)
174-225Mhz
(T37n-xx )
400-440Mhz
(T85n-xx-xxxx)
870-960Mhz
(T88n-xx-xxxx)
ARE REQUIRED MODULES TYPE APPROVED, COUNTRY OF USE :- PART 03.
DO YOU KNOW WHAT IS REQUIRED PER RACK?
Description Option Required Qty Part Number
Rackframe
Receiver
Transmitter
Exciter
50 WattsPower Amplifier
70 / 100 Watt s
AC for Volts
External 13.8V Supply
Power Supply
Battery
Converter 12/12, 24/12, 48/12
Circuit Breaker 10Amp, 20Amp or 30Amp
Alarm Unit
Monitor Unit
Tone Remote
Combiner 200W
Hi Stability Osc
Channel Panel 10 Channel / 100 Channel
Cooling Fan Single or Double
Relay-50 W Max
Duplexer Tx/Rx Frequencies required
Duplexer Cradle (T800-42-0001)
Blank Panel (316-06615-00)
Speaker Panel Single/ selectable
CONVENTIONAL T800 EQUIPMENT
Customer Information: Date:
Customer / C.S.O From: Purchase Order Number: RSD Quote Reference: RSD Staff Responsible:
Page 10
T800temp.V11.doc : Issued 09 Sept 1999 Page 2 of 4
PART 04. EQUIPMENT TYPE REQUIRED :- SERIES I SERIES II
PART 05. DO YOU KNOW THE FREQUENCIES AT THIS TIME?
No To be advised Attached
Yes
Tx MHz CTCSS Hz
Rx MHz CTCSS Hz
Channel Panel Eprom Info To be advised Attached
PART 06.
AUXILLIARY EQUIPMENT :-
Description OPTION REQUIRED Qty Part Number
For Freq:- Mhz
Power Monitor Kit
Automatic
Changeover
Unit
Installation Kit
PART 07. ANCILLIARY EQUIPMENT :-
Description Qty Part Number
Cabinet
Microphone
Programming Software
Module Extender with 2 D Ranges(standard)
Module Extender with 11 way D Range(QS)
Service Manuals
PART 08. BRIEF DESCRIPTION : (Diagram / Info rmat i on Sheet Attached?) Yes No
PART 09. ADDITIONAL COMMENTS :-
PART 10.
DATE REQUIRED
Purchase Order Number:
Page 11
T800temp.V11.doc : Issued 09 Sept 1999 Page 3 of 4
PART 11. TRANSMITTER/EXCITER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm Tx Time Out : External Reference Disabled
Transmitter Power : Enabled
25 Watts (Max Time 5 mins) Duration Mins 50 Watts Tx Tail Time :
(For 800MHz Max 70W) 70 Watts Disabled
100 Watts Enabled
Other Watts (Max Time 5 secs) Duration Secs
Number of Channels : Audio Response :
Single Pre-emphasised
(Freq MHz) Flat
Multiple Special Modifications
(Pattern Required) No
Yes
Line Level : dBm Refer to Part 08
PART 12. RECEIVER PARAMETERS :- STANDARD CUSTOMISED
(As Manual) (Identify Requirements)
Channel Spacing : C.T.C.S.S. :
12.5 kHz No
20.0 kHz Yes
25.0 kHz Single
Other kHz (Freq Hz)
Frequency Stability : (VHF) 2.5 ppm Multiple
1.5 ppm (Pattern Required) (UHF) 1.0 ppm External Reference Audio Response :
Number of Channels : De-emphasised
Single Flat
(Freq MHz)
Multiple R.S.S.I. : (UHF Equipment Only)
(Pattern Required) Note:All other equipment No
has RSSI as standard Yes Special Modifications
Line Level : dBm No
Yes
Gating Operating Level : Refer to Part 08
Purchase Order Number:
Page 12
T800temp.V11.doc : Issued 09 Sept 1999 Page 4 of 4
SYSTEM BLOCK DIAGRAM (OPTIONAL)
Page 13
M800RACK-00-100 Section 1
Copyright TEL 30/8/99
T800SII Numbering System
Conventional Rack Systems ordered from RSD using the adjacent Numbering System will be configured as follows:
Rack Configuration
The Racks used in these configurations are as per Section 2 of this guide, which illustrates the factory default spe cifications.
Each Rack is fully wired and set-up for AC or DC power supply options. (Refer to Section 3).
A Speaker / Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as required.
If the System Type is code “B”, a co-axial relay is fitted as standard. If any other code is used, then relays must be requested if required.
Module Configuration
All Rx and Ex/Tx modules are fitted with second D-ranges as Standard. ie.(T8XX-XX-0200)
All technical information on this Rack configuration is available from RSD.
Page 14
Order Number System
14/12/1999
B A 1 W D 0 0
System
Type
Frequency
Band
RF Output
Power
Channel Spacing
Power
Supply
Duplexer
Ancillary
Options
B = R = S = P = T = D =
Q =
H =
L =
Base Station Repeater Slimline Portable Tone Remote Dual Base Quasi-Sync HSO Rack Liberty
(T800-22-XXXX) (T800-22-XXXX) (T800-23-0000) (T800-25-XXXX) (T800-27-XXXX) (T800-22-001X) (T800-24-XXXX) (T800-28-XXXX) (T800-56-XXXX)
A =
B = C = D = E =
F =
G =
H =
I =
J =
K =
L =
66 - 88 136 - 156 148 - 174 400 - 440 440 - 480 480 - 560 800 - 880 870 - 960 220 - 244 243 - 270 265 - 285 330 - 380
(T82x-xx) (T83x-1x) (T83x-2x) (T85x-1x) (T85x-2x) (T85x-3x) (T88x-1x) (T88x-2x) (T86x-1x) (T86x-2x) (T86x-3x) (T87x-2x)
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
1 = 2 = 3 = 4 =
25 Watts 50 Watts 90 or 100 Watts 5 Watts
0 = 1 = 2 = 3 = 4 = 5 =
No Ancillary Option Circuit Breaker Panel Tx/Rx Metering & Monitor Unit Multi-Channel Panel (100 CH) Multi-Channel Panel (10 CH) Alarm Module
(T800-17-00XX) (T818-01-0000) (TA087-01-0000) (TA387-01) (TA136-02-0000)
0 = 1 = 2 =
No Duplexer Fitted 50 Watt Duplexer Fitted Coaxial Relay
This item code is always set to (0) for Slimline configurations.
If Duplexer item code is set to (1), then Base/Repeater/Slimline Requirement sheet must be completed.
A = B =
D =
Power Supply Slimline Power Supply
DC External Power supply
(T807-10-0000) (T808-10-0000) (T807-23-0010)
Example: BA1WD00
Receiver
T800//
Line level
Suppl
y
Monitor Volume
Monitor
Mute
Off On
Gatin
g
Sensitivit
y
Gate
Transmitter
Line
Sensitivit
y
Suppl
y
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800//
Speaker Panel
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
B = A =
1 =
W =
D =
0 = 0 =
Base Station 66 -88 MHz 25 Watts 25 kHz DC External Power supply Fitted No Duplexer Fitted No Ancillaries Fitted
N =
M =
W =
E =
12.5 kHz 20 kHz 25 kHz 50 kHz
Equipment list T825-10-0200
T826-10-0200 T800-22-0000
This set-up comes complete with all required Blank Panels and a Speaker/Programming Panel
Page 15
X800-9x-000y
X800-9x-000y
X800-9x-000y
T8n7 - T8n7 -
T8n7 - T8n7 -
T8n6 -
Relevant Module
T number
8
8
8
8
8
7
7
7
7
8
7
Refer to
Sections 2&3
Options
shown.
Default Power
8
8
8
2
Cross-
Reference
Section
01/12/1999
Slimline
Fylde TSC Interface
Paging
Monitor (T818)
Speaker
Alarms (TA136)
Quasi Sync
Link
T803 Remote/Alarm
Portable
Optional CH/PNL
Optional relay
Optional fan
Optional Duplexer
Circuit breaker
Converter
Battery back-up
External 13.8V DC
AC
100W Transmit
50W Transmit
25W Transmit
Receive only
Dual system
Single system
Module Function
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x06
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x10
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x11
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x12
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x14
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x15
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x16
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x17
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x20
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x21
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x22
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x23
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 22 - 0x24
2
2
2
2
2
2
2
2
T800 - 23 - 0x00
2
2
2
2
2
2
2
2
T800 - 23 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 24 - 0x02
Rack and Function Cross-Reference Chart
Page 16
01/12/1999
Slimline
Fylde TSC Interface
Paging
Monitor (T818)
Speaker
Alarms (TA136)
Quasi Sync
Link
T803 Remote/Alarm
Portable
Optional CH/PNL
Optional relay
Optional fan
Optional Duplexer
Circuit breaker
Converter
Battery back-up
External 13.8V DC
AC
100W Transmit
50W Transmit
25W Transmit
Receive only
Dual system
Single system
Module Function
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0001
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 25 - 0002
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 27 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 27 - 0x01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 28 - 0x00
2
2
2
2
2
2
2
2
2
2
T800 - 29 - 0x00
2
2
2
2
2
2
2
2
2
2
2
2
2
2
T800 - 29 - 0x01
2
2
2
2
2
2
2
2
T800 - 29 - 0x02
Rack and Function Cross-Reference Chart
Page 17
T800 SeriesII Rack and Module Weights
Weight (kg)
0.00
Rackframe
to house 2 modules 3.60 to house 3 modules 4.15 to house 4 modules 4.70 to house 5 modules 5.25 to house 6 modules 5.80 to house 7 modules 6.35
T8n5 Receiver 2.20 T8n6 Transmitter 2.05 T8n7 Exciter 2.05
50W Power Amplifier 3.20 100W Power Amplifier 3.55
T80n Power Supply 2.30 Circuit breaker 0.50 DC Converter Module 0.90
TA136 Alarm Unit 0.85 T818 Monitor 0.95 TA807 Channel Panel 0.35 TA320 Combiner 2.80 Duplexer 1.15 Duplexer Cradle 0.55 T803 Tone Remote / Alarm 1.55 T801-20 High Stability Oscillator 1.50
Portable Repeater Case
to house 3 modules (Standard) 6.00 to house 4 modules 6.15
2 Batteries (Standard) 5.60
01/12/1999
Page 18
Page 19
T800 Series
II
Conventional Equipment
Reference Guide
Rack
Configuration
Page 20
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x00
A standard single channel rack for repeater or base station use; up to 100 Watt output.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” ra ck to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown) 25W - 11.25kg 50W - 14.45kg 100W - 14.80kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 21
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x00 RACKFRAME
TITLE:
RACK, SNGL<100W, (OPT BD
Drawn DateChecked
AMM 22/10/98ABB
AMM 24/8/99ABB
AMM 14/12/98ABB
AMM 8/3/99ABB
AMM 26/11/99ABB
Version
1
4
2
3
5
Original
Drawing No changed and Ref. added
Change of Title
Parts list added
Drawing name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Speaker Panel
T800//
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
FAN (OPTIONAL)
OPTIONAL
BLANK
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE 1X800-90-0000 POWER RAIL (STANDARD)
1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
PA ReceiverExciter
T800-50-0000
Speaker
Panel
FAN (OPTIONAL)
Page 22
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x06
A 25 Watt single channel rack for repeater or link use.
Operational Characteristics
Single channel
Up to 25W Transmitter Output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
Microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
7.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 23
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x06
TITLE:
RACK, REPEATER/LINK END DC
Drawn DateChecked
AMM 19/2/99ABB
AMM 24/8/99ABB
Version
12Original
Drawing No changes and Ref. added
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Speaker Panel
T800//
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
FRONT VIEW
REAR VIEW
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE 1X800-91-0000 POWER RAIL (STANDARD)
1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
SECTION 4
REFERENCE
SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
EARTH
STUD
DC INPUT FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
ReceiverTransmitter
T800-50-0000
Speaker
Panel
Page 24
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x10
A single channel repeater or base station rack based on the standard T800-22-0x00, with the option of fitting a Channel Panel.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Length - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 11.25kg 50W - 14.45kg 100W - 14.80kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 25
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x10 RACKFRAME
TITLE
RACK, SNGL<100W, (CH PNL
Drawn DateChecked
AMM 21/10/98ABB
AMM 25/8/99ABB
AMM 14/12/98ABB
AMM 8/3/99ABB
AMM 26/11/99ABB
Version
1
4
2
3
5
Original
Drg No changed and Ref added
Change of Title
Parts list added
Drawing name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line
level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
Excellence in Radio Communications
T800//
Excellence in Radio Communications
T800//
Speaker Panel
T800//
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
OPTIONAL CHANNEL
PANEL
FAN (OPTIONAL)
OPTIONAL
BLANK
1X800-90-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0001 BACKPLANE CH-PNL
1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
PA ReceiverExciter
T800-50-0001
Speaker
Panel
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FAN (OPTIONAL)
Page 26
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x11
A Receiver only rack with alarm outputs, AC power supply and dual battery back-up connections.
Operational Characteristics
Receive only - up to 4 receivers
Speaker / Programming panel - with Receiver Speaker Select Switch
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Fans - single or double
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
17.75kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 27
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x11
TITLE:
RACK, RX ONLY AC
(4RX + ALARM + SPK)
Drawn DateChecked
AMM 20/10/98AB B
AMM 22/7/99ABB
AMM 14/12/98AB B
AMM 8/3/99ABB
AMM 25/8/99ABB
Version
1
4
2
3
4
Original
Frame label removed
Change of Title
Parts list added
drg No changed and Ref added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
T800//
Power Supply
Power
On
Standby
Overload
Speaker Panel
T800// T800//
Alarm Panel
Power
PSU Fail
Forward
Test
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
OPTIONAL
CHANNEL
PANEL
OPTIONAL
or BLANK
Receiver
Speaker Select
16
25
34
1X800-93-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-11-0004 RACK, FRAME ONLY, ASSEMBLED 2 BATT BACK-UP
QTY
2T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0000 GUIDE KIT T1500/300 DOUBLE 'D' 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0002 SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH
2T800-50-0002 BACKPLANE
1T800-40-0000 FIXING KIT ONLY
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
Alarm
ReceiverReceiverReceiverReceiver
T800-50-0002 T800-50-0002
Speaker
Panel
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 28
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x12
Receive only rack similar to T800-22-0x11; but with no alarm outputs.
Operational Characteristics
Receive only - up to 4 receivers
Speaker / Programming panel - with Receiver Speaker Select Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Fans - single or double
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.35kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 29
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x12
TITLE:
RACK, RX ONLY AC (4RX + SPK)
Drawn DateChecked
AMM 20/10/98AB B
AMM 25/8/99ABB
AMM 14/12/98AB B
AMM 8/3/99ABB
Version
1
3
2
3
Original
drg No changed and Ref added
Change of Title
Parts list added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
OPTIONAL
CHANNEL
PANEL
OPTIONAL
or BLANK
Excellence in Radio Communications
T800//
Speaker Panel
T800//
Receiver
Speaker Select
16
25
34
1X800-90-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 8 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
2T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT
1T800-15-0002 SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH
2T800-50-0002 BACKPLANE
1T800-40-0000 FIXING KIT ONLY
1T800-40-0001 BLANKING BRACKET / FRONT PANEL
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
ReceiverReceiverReceiverReceiver
T800-50-0002 T800-50-0002
Speaker
Panel
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 30
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x13
A dual 50 Watt channel rack, with AC power supply and DC battery back-up connections.
Operational Characteristics
Dual channel
50W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only Not Available
(see T800-22-0x16)
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery Not Available
(see T800-22-0x16)
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
23.55kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 31
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x13 RACKFRAME
TITLE:
RACK, DUAL 2x50W
Drawn DateChecked
AMM 18/2/99ABB
AMM 25/8/99ABB
AMM 29/11/99ABB
Version
1
2
3
Original
Drg No change, ref added, PS,PA moved
Drg name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
FAN (OPTIONAL) FAN (OPTIONAL)
1X800-93-0002 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 5 SECTION 3
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED BATTERY BACK-UP
QTY
2T800-41-0002 DOUBLE GUIDE KIT 2T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 2T800-50-0001 BACKPLANE
The rack configuration has been changed to reduce
the risk of overheating in some environments.
It is recommended that the optional fans are fitted.
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
FAN
(OPTIONAL)
PA ReceiverExciter
T800-50-0001
ReceiverExciter
T800-50-0001
PA
FAN
(OPTIONAL)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 32
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x14
A dual 25 Watt channel rack, with AC power supply and DC battery back-up connections.
Operational Characteristics
Dual channel
25W output
Dual Speaker / Programming panel (switchable)
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only Not Available
(see T800-22-0x17)
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery Not Available
(see T800-22-0x17)
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Individual Speaker / Programming panels
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.05kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 33
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x14 RACKFRAME
TITLE:
RACK, DUAL 2x25W, SPK SW
Drawn DateChecked
AMM 12/1/99ABB
AMM 2/9/99ABB
AMM 18/3/99ABB
AMM 25/8/99ABB
AMM 29/11/99ABB
Version
1
4
2
3
5
Original
Dual spk replaced by switched spk
Parts list added, fans removed
Drg No changed, ref added, PA, PS moved
Drg name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
OPTIONAL SPEAKER
(T800-15-0000)
OPTIONAL DUPLEXER
AND/OR CHANNEL PANEL
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Speaker Panel
T800//
RX 1
RX 2
O F F
O F F
Excellence in Radio Communications
T800//
OPTIONAL SPEAKER
(T800-15-0000)
OPTIONAL DUPLEXER
AND/OR CHANNEL PANEL
1T800-40-0001 BLANKING BRACKET / FRONT PANEL SECTION 8
1X800-93-0001 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP
QTY
2T800-41-0002 DOUBLE GUIDE KIT
1T800-15-0003 SPEAKER / PROGRAM PANEL
2T800-50-0001 BACKPLANE
1T800-40-0000 FIXING KIT ONLY
1T800-44-0000 T800 PS GUIDE KIT
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
ReceiverTransmitter
T800-50-0001
Speaker
Panel
ReceiverTransmitter
T800-50-0001
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 34
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x15
A dual 25 Watt channel rack with a separate power supply for each channel. The speaker panel can be switched between receivers.
Operational Characteristics
Dual channel
25W output
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
16.6kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 35
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x15 RACKFRAME
TITLE:
RACK, DUAL 2x25 WATT, (2 P/SUP
Drawn DateChecked
AMM 12/1/99ABB
AMM 29/11/99ABB
AMM 3/2/99ABB
AMM 25/8/99ABB
Version
1
3
2
3
Original
Drg name changed
Standard supply table added
Drg No changed, Ref added, Relay removed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Rec eiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
T800//
Power Supply
Power
On
Standby
Overload
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Rec eiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Speaker Panel
T800//
RX 1
RX 2
O F F
O F F
1X800-22-0015 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
2T800-41-0002 DOUBLE GUIDE KIT 2T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0001 BACKPLANE
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
Speaker
Panel
ReceiverTransmitter
T800-50-0001
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
DIODE
PACK
ReceiverTransmitter
T800-50-0001
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 36
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x16
A dual 50 Watt channel rack for use in DC only situations.
Operational Characteristics
Dual channel
50W output per channel
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
20.7kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 37
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x16 RACKFRAME
TITLE:
RACK, DUAL 2x50W, (SPK SWITCHED)
Drawn DateChecked
AMM 15/2/99ABB
AMM 25/8/99ABB
AMM 29/11/99ABB
Version
1
2
3
Original
Drg No changed, Ref added, PA moved
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power AmplifierSpeaker Panel
T800//
RX 1 RX 2
O F F
O F F
FAN (OPTIONAL)FAN (OPTIONAL)
1X800-91-0002 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
2T800-41-0002 DOUBLE GUIDE KIT 2T800-45-0000 GUIDE PA 50W KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-50-0001 BACKPLANE
The rack configuration has been changed to reduce
the risk of overheating in some environments.
It is recommended that the optional fans are fitted.
EARTH
STUD
DC INPUT FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
ReceiverPA Exciter
T800-50-0001
FAN
(OPTIONAL)
Speaker
Panel
Exciter Receiver
T800-50-0001
PA
FAN (OPTIONAL)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 38
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x17
A dual 25 Watt channel rack for use in DC only situations.
Operational Characteristics
Dual channel
25W output per channel
Speaker / Programming panel, with Receiver Selectable Switch
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
(see T800-22-0x14)
x = 1 External DC only
x = 2 AC and External DC Not Available
(see T800-22-0x14)
x = 3 AC and Battery Not Available
(see T800-22-0x14)
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
(see T800-22-0x14)
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
13.2kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 39
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x17 RACKFRAME
TITLE:
RACK, DUAL 2X25W, (SPKR SW)
Drawn DateChecked
AMM 2/6/99ABB
AMM 25/8/99ABB
AMM 29/11/99ABB
Version
1
2
3
Original
Drg No changed, Ref added
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800//
OPTIONAL
DUPLEXER
and/or
CHANNEL
PANEL
OPTIONAL
BLANK
Speaker Panel
T800//
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800//
RX 1 RX 2
O F F
O F F
OPTIONAL
DUPLEXER
and/or
CHANNEL
PANEL
1X800-91-0001 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4 SECTION 8
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
2T800-41-0002 DOUBLE GUIDE KIT 1T800-15-0003 SPEAKER / PROGRAM PANEL 3-WAY SWITCH
2T800-50-0001 BACKPLANE
2T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANKING BRACKET / FRONT PANEL
ReceiverTransmitter
Speaker
Panel
ReceiverTransmitter
EARTH
STUD
DC INPUT FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
T800-50-0001 T800-50-0001
DR2DR1
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 40
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x20
A single repeater or base station channel rack up to 100 Watt maximum output. The rack can accommodate an Rx/Tx Monitor panel and AC power input.
Operational Characteristics
Single channel
Up to 100W with option of Transmitter or Exciter / PA combination
Speaker / Programming panel
Rx/Tx Monitor Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only Not Available
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery Not Available
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.2kg 50W - 15.95kg 100W - 16.3kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 41
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x20 RACKFRAME
TITLE:
RACK, SNGL<100W, (MONITOR)
Drawn DateChecked
AMM 12/1/99ABB
AMM 29/11/99ABB
AMM 8/3/99ABB
AMM 25/8/99ABB
Version
1
4
2
3
Original
Drg name changed
Parts list added
Drg No changed, Ref added
FRONT VIEW
REAR VIEW
OPTIONAL
DUPLEXER
OPTIONAL
CHANNEL
PANEL
Rx/Tx Monitor
T800//
Supply
Volume
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
Off
Speaker Panel
T800//
Excellence in Radio Communications
T800//
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
T800//
Power Supply
Power
On
Standby
Overload
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK PANEL
FAN (OPTIONAL)
1X800-90-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 8
SECTION 3
SECTION 4 SECTION 8
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT
1T800-45-0000 GUIDE PA 50W KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE
1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL
1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D'
1T800-60-0000 PERSONALITY BOARD
SECTION 4
SECTION 5 SECTION 6
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
PA ReceiverExciter
Rx/Tx MON
T818-01-0000
T800-50-0000
T800-60-0000
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
Speaker
Panel
FAN (OPTIONAL)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 42
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x21
A single 25 Watt repeater or base station channel rack to accommodate an Rx/Tx Monitor and rack mounted circuit breaker for protection on the DC power input.
Operational Characteristics
Single channel
25W output only
Speaker / Programming panel
Panel circuit breaker
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
10.35kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 43
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x21 RACKFRAME
TITLE:
RACK, SNGL<25W, (MONITOR)
Drawn DateChecked
AMM 22/10/98ABB
AMM 25/8/99ABB
AMM 14/12/98ABB
AMM 18/3/99ABB
AMM 29/11/99ABB
Version
1
4
2
3
5
Original
Drg No changed, Ref added
Change of Title
Parts list added
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
OPTIONAL
DUPLEXER
OPTIONAL
CHANNEL
PANEL
Excellence in Radio Communications
T800//
Rx/Tx Monitor
T800//
Supply
Volume
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
Off
Speaker Panel
T800//
Excellence in Radio Communications
T800//
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Circuit Breaker
On
1
0
Off
Supply
12V
1X800-22-0121 POWER RAIL (STANDARD)
SECTION 5
SECTION 3
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D'
1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE 1T800-60-0000 PERSONALITY BOARD
1T800-17-0010 PANEL CIRCUIT BREAKER WITH 10AMP SWITCH
1T800-45-0000 GUIDE PA 50W KIT
1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL
1316-06615-00 BLANKING FRONT PANEL ONLY
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 4 SECTION 8
SECTION 6
SECTION 8
SECTION 8
Rx/Tx MON
T818-01-0000
Circuit
Breaker
ReceiverTransmitter
T800-50-0000
T800-60-0000
Speaker
Panel
EARTH
STUD
DC INPUT
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 44
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x22
A single 50 Watt repeater or base station channel rack to accommodate an Rx/Tx Monitor and rack mounted circuit breaker for protection on the DC power input.
Operational Characteristics
Single channel
50W output only
Speaker / Programming panel
Panel circuit breaker
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
14.1kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 45
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x22 RACKFRAME
TITLE:
RACK, SNGL<=50W, (MONITOR)
Drawn DateChecked
AMM 22/10/98ABB
AMM 25/8/99ABB
AMM 14/12/98ABB
AMM 8/3/99ABB
AMM 29/11/99ABB
Version
1
4
2
3
5
Original
Drg No changed, Ref added
Change of Title
Parts list added
Drg name changed
FRONT VIEW
REAR VIEW
OPTIONAL
DUPLEXER
OPTIONAL
CHANNEL
PANEL
Rx/Tx Monitor
T800//
Supply
Volume
Volts Rx Signal Rx Line Tx Line Fwd Pwr Rev Pwr
Off
Speaker Panel
T800//
Excellence in Radio Communications
T800// T800//
Circuit Breaker
On
1
0
Off
Supply
12V
Receiver
T800//
Line level
Supply
Monitor
Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
1
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 6 SECTION 3
SECTION 4 SECTION 8 SECTION 8 SECTION 5
1X800-22-0122 POWER RAIL (STANDARD)
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT
1T800-45-0000 GUIDE PA 50W KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL
1T800-50-0000 BACKPLANE
1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / FRONT PANEL
1T800-43-0001 GUIDE KIT T1500/300 SINGLE 'D'
1T800-60-0000 PERSONALITY BOARD
T800-17-0020 PANEL CIRCUIT BREAKER WITH 20AMP SWITCH
EARTH
STUD
DC INPUT
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
PA ReceiverExciter
Rx/Tx MON
T818-01-0000
Circuit
Breaker
T800-50-0000
T800-60-0000
Speaker
Panel
FAN (OPTIONAL)
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
FAN (OPTIONAL)
Page 46
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x23
A single channel rack with 50 Watt maximum output, alarm outputs and AC power supply.
Operational Characteristics
Single channel
Up to 50W output
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.1kg 50W - 15.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 47
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x23 RACKFRAME
TITLE:
RACK, SNGL<100W, (ALARMS 0V)
Drawn DateChecked
AMM 15/2/99ABB
AMM 29/11/99ABB
AMM 30/3/99ABB
AMM 25/8/99ABB
Version
1
4
2
3
Original
Drg name changed
Change personality board
Drg No changed, Ref added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Excellence in Radio Communications
T800//
Speaker Panel
T800// T800//
Power Supply
Power
On
Standby
Overload
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
T800//
Alarm Panel
Power
PSU Fail
Forward
Test
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
OPTIONAL
CH/PNL
FAN (OPTIONAL)
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
1X800-93-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 8
SECTION 5
SECTION 3
SECTION 4 SECTION 8
1T800-50-0000 BACKPLANE
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT
1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / F-PNL KIT
1T800-43-0000 GUIDE KIT T1500/300 1T800-44-0000 T800 PS GUIDE KIT
1T800-60-0002 PERSONALITY BOARD + CH/PNL + ALARMS (0V)
SECTION 4
SECTION 6
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
Receiver
Transmitter
or Exciter
T800-60-0002
Personality
Board
Alarm
PA
FAN
(OPTIONAL)
T800-50-0000
Speaker
Panel
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 48
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-22-0x24
A single channel rack with 50 Watt maximum output, alarm outputs (LO) and AC power supply.
Operational Characteristics
Single channel
Up to 50W output
Speaker / Programming panel
Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.1kg 50W - 15.85kg
NOTE:
This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 49
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-22-0x24 RACKFRAME
TITLE:
RACK, SNGL<100W, (ALARMS LO)
Drawn DateChecked
AMM 7/9/99ABB
AMM 29/11/99ABB
Version
12Original
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Excellence in Radio Communications
T800//
Speaker Panel
T800// T800//
Power Supply
Power
On
Standby
Overload
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
T800//
Alarm Panel
Power
PSU Fail
Forward
Test
Batt Fail
Forward
Reflected
Alarm#1
Alarm#2
Alarm#3
Alarm#4
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
OPTIONAL
CH/PNL
FAN (OPTIONAL)
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
1X800-93-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 8
SECTION 5
SECTION 3
SECTION 4 SECTION 8
1T800-50-0000 BACKPLANE
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-45-0000 GUIDE PA 50W KIT
1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANKING BRACKET / F-PNL KIT
1T800-43-0000 GUIDE KIT T1500/300 1T800-44-0000 T800 PS GUIDE KIT
1T800-60-0001 PERSONALITY BOARD + CH/PNL + ALARMS (LO)
SECTION 4
SECTION 6
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
Receiver
Transmitter
or Exciter
T800-60-0001
Personality
Board
Alarm
PA
FAN
(OPTIONAL)
T800-50-0000
Speaker
Panel
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 50
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-23-0x00
A single channel rack with 25 Watt maximum output mounted in a 2RU Slimline configuration for use in DC situations.
Operational Characteristics
Single channel
Up to 25W output
Speaker / Programming Port
Power Supply Options
x = 0 AC only Not Available
(see T800-23-0x01)
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Coaxial Relay
Microphone
Mechanical Characteristics
2 Rack Units x 19” rack to house up to 7 modules
Size
Height - 89mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W – 3.9kg
This configuration includes Receiver and Transmitter modules. (to be specified when ordering)
Page 51
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-23-0x00
TITLE:
SLIMLINE 25W DC
Drawn DateChecked
AMM 20/9/99ABB
Version
1 Original
FRONT VIEW
REAR VIEW
ReceiverTransmitter
TB
Receiver
Line Level
Supply
Monitor
Volume
Monitor
Gating
Sensitivity
Gate
On Off
T800//
Transmitter
Line
Sensitivity
Supply
Exciter Out
On
MicrophoneCarrier
T800II Slimline
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-23-0000 SLIMLINE ASSEMBLY KIT + CABLES
QTY
1T8n5-nn-nnnn RECEIVER 1T8n6-nn-nnnn TRANSMITTER
SECTION 4
REFERENCE
SECTION 8 SECTION 8
Page 52
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-23-0x01
A single channel rack with 25 Watt maximum output mounted in a 2RU Slimline configuration, with an AC power supply.
Operational Characteristics
Single channel
Up to 25W output
Speaker / Programming Port
Power Supply Options
x = 0 AC only
x = 1 External DC only Not Available
(see T800-23-0x00)
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery Not Available
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Microphone
Mechanical Characteristics
2 Rack Units x 19” rack to house up to 7 modules
Size
Height - 89mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W – 8.55kg
This configuration includes Receiver and Transmitter modules. (to be specified when ordering) .
Page 53
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-23-0x01
TITLE:
SLIMLINE 25W AC
Drawn DateChecked
AMM 20/9/99ABB
Version
1 Original
FRONT VIEW
REAR VIEW
ReceiverTransmitter
Power Suppl
y
TB
Receiver
Line Level
Supply
Monitor
Volume
Monitor
Gating
Sensitivity
Gate
On Off
T800//
Transmitter
Line
Sensitivity
Supply
Exciter Out
On
MicrophoneCarrier
T800II Slimline
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-23-0001 SLIMLINE ASSEMBLY KIT + CABLES + POWER SUPPLY
QTY
1T8n5-nn-nnnn RECEIVER 1T8n6-nn-nnnn TRANSMITTER
SECTION 4
REFERENCE
SECTION 8 SECTION 8
Page 54
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-25-0000
A single 25W channel, housed in a portable case with sealed lead acid batteries.
Operational Characteristics
Single channel
Up to 25W output
DC only operation - Batteries and external DC supply input
Speaker / Programming panel
DC line fuse
Backplane interface
Battery Isolation Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
15.85kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 55
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-25-0000
TITLE:
T800-25-0000 PORTABLE
Drawn DateChecked
AMM 4/3/99AB B
AMM 26/8/99ABB
AMM 2/6/99AB B
AMM 30/6/99ABB
Version
1
4
2
3
Original
Reference added
Diode pack alignment corrected
Battery details added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line
level
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Supply
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Speaker Panel
T800//
T8n5 -nn-0200 T8n6 -nn-0200
T800-15-0000
SPKR/PROG PNL
or TA087-01-0000 100 CHANNEL
CHANNEL PANEL
or TA387-01-0000
10 CHANNEL
CHANNEL PANEL
EXTERNAL DC BATTERY OPERATION
TALK THROUGH
BASE STATION REPEATER
FUSE
10A
T800-50-0001
DC
ON
OFF
Duplexer mounted behind
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5
SECTION 4
1W800-25-0000 WIRING LIST T800-25-0000
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-40-0001 BLANK PANEL AND FIXING KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-50-0001 BACKPLANE
1X800-25-0000 STANDARD LOOM ASSEMBLY
2290-00010-48 BATTERY SEALED LEAD ACID 12V 6.5A
Page 56
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-25-0001
A single 25W channel, housed in a portable case with sealed lead acid batteries. This unit can use an external AC power source.
Operational Characteristics
Single channel
Up to 25W output
AC and DC operation - Batteries, external AC and DC supply input
Speaker / Programming panel
DC line fuse
Backplane interface
Battery Isolation Switch
Talk Through Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
18.3kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 57
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-25-0001
TITLE:
T800-25-0001 PORTABLE
Drawn DateChecked
AMM 5/3/99AB B
AMM 26/8/99ABB
AMM 1/6/99AB B
AMM 30/6/99ABB
Version
1
4
2
3
Original
Reference added
Diode pack alignment corrected
Battery details added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line
level
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Supply
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Speaker Panel
T800//
T8n5 -nn-0200 T8n6 -nn-0200
T800-15-0000
SPKR/PROG PNL
or TA087-01-0000 100 CHANNEL
CHANNEL PANEL
or TA387-01-0000
10 CHANNEL
CHANNEL PANEL
T800//
Power Supply
Power
On
Standby
Overload
EXTERNAL DC BATTERY OPERATION
TALK THROUGH
BASE STATION REPEATER
Output
13.8V 25A Max.
+
-
1 2 3 4 5
FUSE
10A
T800-50-0001
DC
and
SIGS
ON
OFF
Duplexer mounted behind
AC
I/P
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5
SECTION 4
1W800-25-0000 WIRING LIST T800-25-0000
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER / PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 1T800-50-0001 BACKPLANE
1X800-25-0000 STANDARD LOOM ASSEMBLY
2290-00010-48 BATTERY SEALED LEAD ACID 12V 6.5A
Page 58
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-25-0002
A single channel with up to 50W output, housed in a portable case with no batteries. This unit can use external AC or DC power source.
Operational Characteristics
Single channel
Up to 50W output
AC and DC operation - External AC and DC supply input
DC line fuse
Backplane interface
Battery Isolation Switch
Talk Through Switch
Configuration Options
Channel Panel
Duplexer
Coaxial Relay
Antenna
Mechanical Characteristics
Portable case to house up to 4 modules
Top Mounting Duplexer Tray
Size
Case Only with Handles and Connectors Height - 242mm 305mm Width - 255mm 300mm Depth - 460mm 460mm
Weight – (rackframe with modules shown)
25W - 12.55kg 50W - 15.9kg
CAUTION: If operating above 15 Watts, front and rear covers must be removed.
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 59
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-25-0002
TITLE:
PORTABLE REPEATER <=50W
X-DC + AC (NO BATT)
Drawn DateChecked
AMM 4/6/99AB B
AMM 26/8/99ABB
Version
12Original
Reference added
FRONT VIEW
REAR VIEW
Receiver
T800//
Line
level
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Supply
OPTIONAL BLANK
PANEL
or
OPTIONS PANEL
OPTIONAL
TRANSMITTER
T800-15-0000
SPKR/PROG PNL
or
TA087-01-0000
100 CHANNEL
CHANNEL PANEL
or
TA387-01-0000
10 CHANNEL
CHANNEL PANEL
T800//
Power Supply
Power
On
Standby
Overload
EXTERNAL DC BATTERY OPERATION
TALK THROUGH
BASE STATION REPEATER
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
T800-15-0000
SPKR/PROG PNL
or
TA087-01-0000
100 CHANNEL
CHANNEL PANEL
or
TA387-01-0000
10 CHANNEL
CHANNEL PANEL
Output
13.8V 25A Max.
+
-
1 2 3 4 5
FUSE
10A
T800-50-0001
DC
I/P
Duplexer mounted behind
AC
I/P
DR1
DR2
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 5
SECTION 4
1W800-25-0002 WIRING LIST T800-25-0002
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T991-05-0100 CASE, PORTABLE REPEATER - 0100 VERSION
QTY
1T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 PA (50W) GUIDE KIT 1T800-50-0001 BACKPLANE 1X800-25-0002 RACK KIT
Page 60
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-27-0x00
A dual channel rack with 25 Watt per channel maximum output and Tone Remote / Alarm outputs.
Operational Characteristics
Dual channel
Up to 25W output
Speaker / Programming panel
Remote / Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 20.25kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 61
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-27-0x00 RACKFRAME
TITLE:
RACK, DUAL 2X25W, (REMOTE
Drawn DateChecked
AMM 20/10/98ABB
AMM 26/8/99ABB
AMM 26/11/99ABB
Version
1
4
2
3
Original
Drg No changed, Ref added
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line
level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Remote / Alarm
T800//
Talk Through
Base Station
Monitor On / Off
Monitor Volume
Mode Toggle
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Programming
Port
Clear Alarms
Test (3 sec)
Remote / Alarm
T800//
Talk Through
Base Station
Monitor On / Off
Monitor Volume
Mode Toggle
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Programming
Port
Clear Alarms
Test (3 sec)
OPTIONAL
BLANK
1
QTY
2 1 2 1
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 5 SECTION 3
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
T800-11-0004 RACK, FRAME ONLY, ASSEMBLED 2 BATT BACK-UP T800-41-0003 TRIPLE GUIDE KIT T800-44-0000 T800 PS GUIDE KIT T800-54-0000 BACKPLANE RACK REMOTE X800-93-0001 POWER RAIL (STANDARD)
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
ReceiverTransmitter Remote
T800-54-0000
DR2
ReceiverTransmitter Remote
T800-54-0000
DR1
PLUG SKTPLUG SKT
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
DIODE
PACK
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 62
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-27-0x01
A single channel rack with 100 Watt maximum output, Tone Remote / Alarm outputs and AC power supply.
Operational Characteristics
Single channel
Up to 100W output
Speaker / Programming panel
Remote / Alarm Panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0011
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.8kg 50W - 16.55kg 100W - 16.9kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 63
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-27-0x01 RACKFRAME
TITLE:
RACK, SNGL<100W, (REMOTE
Drawn DateChecked
AMM 1/6/99ABB
AMM 26/8/99ABB
AMM 26/11/99ABB
Version
1
2
3
Original
Drg No changed, Ref added
Drg name changed
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800//
FAN (optional)
Excellence in Radio Communications
T800//T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
OPTIONAL
DUPLEXER
Remote / Alarm
T800//
Talk Through
Base Station
Monitor On / Off
Monitor
Volume
Mode Toggle
Rev Power
Aux 0
Fwd Power
Aux 1
Low Battery
Aux 2
Line Fail
Aux 3
Programming
Port
Clear Alarms
Test (3 sec)
OPTIONAL
BLANK
1X800-90-0000 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 5 SECTION 3
SECTION 8
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0003 GUIDE TRIPLE SERIESII KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 GUIDE PA 50W SERIESII KIT
1X800-54-0000 T803-00-0000 BACKPLANE ASSEMBLY
2T800-40-0001 BLANKING BRACKET / FRONT PANEL
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
PA ReceiverExciter
FAN
Optional
Remote / Alarm
T800-54-0000
DR1
DR2
PLUG SKT
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 64
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-28-0x00
A single channel rack with 100 Watt maximum output, and provision for a High Stability Oscillator to enable the Paging function.
Operational Characteristics
Single channel - Paging
Up to 100W output
Speaker / Programming panel
High Stability Oscillator
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Duplexer
Coaxial Relay
Fans - single or double
Interfaces to Changeover Module TA703-00-xxxx using TA703-11-0010
installation kit
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 12.75kg 50W - 16.5kg 100W - 16.85kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 65
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-28-0x00 RACKFRAME
TITLE:
RACK, SNGL<100W, (PAGING
Drawn DateChecked
AMM 2/6/99ABB
AMM 26/11/99ABB
AMM 30/6/99ABB
AMM 26/8/99ABB
Version
1
4
2
3
Original
Drg name changed
Speaker removed
Drg No changed, Ref added
FRONT VIEW
REAR VIEW
T800//
Power Supply
Power
On
Standby
Overload
Receiver
T800//
Line
level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
FAN (optional)
Excellence in Radio Communications
T800//
HSO
T800//
Supply
12.8 MHz
Frequency
Adjust
10.0 MHz
T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
OPTIONAL
BLANK
OPTIONAL
BLANK
Excellence in Radio Communications
T800//
OPTIONAL
TRANSMITTER
OPTIONAL
BLANK
1X800-90-0004 POWER RAIL (STANDARD)
SECTION 4
REFERENCE
SECTION 4 SECTION 4 SECTION 4
SECTION 5 SECTION 3
SECTION 8
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-24-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0003 GUIDE TRIPLE SERIESII KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-45-0000 GUIDE PA 50W SERIESII KIT
1T800-55-0000 BACKPLANE
2T800-40-0001 BLANKING BRACKET / FRONT PANEL
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
PA ReceiverExciter
FAN
Optional
HSO
T800-55-0000
DR1
DR2
PLUG
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 66
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-29-0x00
A dual channel rack with 25 Watt maximum output, to interface to Fylde Trunking Controller
Operational Characteristics
Dual channel
Up to 25W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 16.05kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 67
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-29-0x00 RACKFRAME
TITLE:
RACK, DUAL 2x25W, (FYLDE
Drawn DateChecked
AMM 2/8/99ABB
AMM 26/11/99ABB
Version
12Original
Drawing name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Speaker Panel
T800//
RX 1 RX 2
O F F
O F F
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off
On
Gating
Sensitivity
Gate
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
Excellence in Radio Communications
T800// T800//
Power Supply
Power
On
Standby
Overload
Transmitter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
OPTIONAL
DUPLEXER
BEHIND SPK/PROG
PANEL
OPTIONAL
DUPLEXER
OPTIONAL
BLANK
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
2T800-41-0002 DOUBLE GUIDE KIT 1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 1T800-40-0001 BLANK PANEL AND FIXING KIT
1X800-90-0001
POWER RAIL (STANDARD)
2T800-57-0000 BACKPLANE (FYLDE)
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
ReceiverTransmitter
T800-57-0000
Speaker
Panel
Power Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
SK107
SK102 SK101
PL101
SK109
RV210RV211
SK201
ReceiverTransmitter
T800-57-0000
SK107
SK102 SK101
PL101
SK109
RV210RV211
SK201
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 68
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-29-0x01
A single channel rack with 100 Watt maximum output, to interface to Fylde Trunking Controller
Operational Characteristics
Single channel
Up to 100W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only
x = 1 External DC only
x = 2 AC and External DC
x = 3 AC and Battery
x = 4 External DC and Battery
x = 5 AC and External DC and Battery
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
25W - 10.7kg 50W - 14.45kg 100W - 14.8kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 69
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-29-0x01 RACKFRAME
TITLE:
RACK, SNGL <=100W, (FYLDE
Drawn DateChecked
AMM 2/8/99ABB
AMM 26/11/99ABB
Version
12Original
Drg name changed
FRONT VIEW
REAR VIEW
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Excellence in Radio Communications
T800// T800//
Power Supply
Power
On
Standby
Overload
OPTIONAL
BLANK
OPTIONAL
TRANSMITTER
FAN
(OPTIONAL)
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier
Excellence in Radio Communications
T800//
Speaker Panel
T800//
OPTIONAL
DUPLEXER
OPTIONAL
BLANK
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-22-0004 RACK, FRAME ONLY, ASSEMBLED
QTY
1T800-41-0002 DOUBLE GUIDE KIT
1T800-44-0000 T800 PS GUIDE KIT 1T800-15-0000 SPEAKER/PROGRAM PANEL 1T800-40-0000 FIXING KIT ONLY 2T800-40-0001 BLANK PANEL AND FIXING KIT
1X800-90-0000 POWER RAIL (STANDARD)
1T800-57-0000 BACKPLANE (FYLDE)
1T800-45-0001 PA (100W) GUIDE KIT
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
PA ReceiverExciter
FAN
(OPTIONAL)
Speaker
Panel
Power
Supply
Output
13.8V 25A Max.
+
-
1 2 3 4 5
T800-57-0000
SK107
SK102 SK101
PL101
SK108
RV210RV211
SK201
DR1
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 70
M800RACK-00-100 Section 2
Copyright TEL 30/8/99
T800-29-0x02
A dual channel rack with 50 Watt maximum output, to interface to Fylde Trunking Controller.
Operational Characteristics
Dual channel
Up to 50W output
Speaker / Programming panel
DC line fuse
Earth stud
Backplane interface
Power Supply Options
x = 0 AC only Not Available
x = 1 External DC only
x = 2 AC and External DC Not Available
x = 3 AC and Battery Not Available
x = 4 External DC and Battery
x = 5 AC and External DC and Battery Not Available
Configuration Options
Fans - single or double
microphone
DC converter
Mechanical Characteristics
5 Rack Units x 19” rack to house up to 7 modules
Size
Height - 222mm Width - 482mm Depth - 322mm plus 50mm clearance space
Weight – (rackframe with modules shown)
50W - 20.7kg
Rack “Items Supplied as Standard” does not include modules other than those listed on the drawing.
Page 71
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
T800-29-0x02 RACKFRAME
TITLE:
RACK, DUAL 2x50W, (FYLDE
Drawn DateChecked
AMM 3/8/99AB B
AMM 31/8/99ABB
AMM 26/11/99AB B
Version
1
2
3
Original
Drg No changed, Ref added
Drg name changed
FRONT VIEW
REAR VIEW
Speaker Panel
T800//
RX 1 RX 2
O
F F
O
F F
Receiver
T800//
Line level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
FAN
(OPTIONAL)
FAN
(OPTIONAL)
T800//
Power
Low forward power
High reverse power
Supply
Power Amplifier Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800// T800//
Power
Low forward power
High reverse power
Supply
Power AmplifierReceiver
T800//
Line
level
Supply
Monitor Volume
Monitor
Mute
Off On
Gating
Sensitivity
Gate
Exciter
Line
Sensitivity
Supply
On
Microphone
Carrier
T800//
1X800-91-0002 POWER RAIL (STANDARD)
REFERENCE
SECTION 4 SECTION 4 SECTION 4 SECTION 8
SECTION 5 SECTION 3
SECTION 4
ITEMS SUPPLIED AS STANDARD
PART NUMBER DESCRIPTION
1T800-11-0004 RACK, FRAME ONLY, ASSEMBLED, 2 BATTERY BACK-UP
QTY
2T800-41-0002 DOUBLE GUIDE KIT 2T800-45-0000 PA (50W) GUIDE KIT 1T800-15-0003 SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH 1T800-40-0000 FIXING KIT ONLY 2T800-57-0000 BACKPLANE (FYLDE)
EARTH
STUD
DC INPUT FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
FUSE
FAN (OPTIONAL)
FAN (OPTIONAL)
Speaker
Panel
Receiver
Exciter
T800-57-0000
SK107
SK102 SK101
PL101
SK108
RV210RV211
SK201
DR3
Receiver
PA Exciter
T800-57-0000
SK107
SK102 SK101
PL101
SK108
RV210RV211
SK201
DR2
DR1
PA
DR4
REFER TO SECTION 3
OF THE
REFERENCE GUIDE
FOR
POWER RAIL OPTIONS
Page 72
T800 Series
II
Conventional Equipment
Reference Guide
Rack
Power Supply
Options
Page 73
M800RACK-00-100 Section 3
Copyright TEL 30/8/99
Power Supply Options
This section details the Power Supply Options f o r T800 SeriesII Conventional rackframes. The power rails have been standardised to allow versatility in the rack applications.
Not all options are available on every rack. Please contact RSD if you are unsure of the correct option.
Baan Codes
X800-90-0000RAIL<=100W,ACfor1supply X800-91-0000RAIL<=100W,AC+X-DCfor1supply X800-92-0000RAIL<=100W,ACfor1supply X800-93-0000RAIL<=100W,AC+BATfor1supply X800-94-0000RAIL<=100W,X-DC+BATfor1supply X800-95-0000RAIL<=100W,AC+X-DC+BATfor1supply
X800-90-0001RAIL,2x25W,ACfor2supply X800-91-0001RAIL,2x25W,AC+X-DCfor2supply X800-92-0001RAIL,2x25W,ACfor2supply X800-93-0001RAIL,2x25W,AC+BATfor2supply X800-94-0001RAIL,2x25W,X-DC+BATfor2supply X800-95-0001RAIL,2x25W,AC+X-DC+BATfor2supply
X800-90-0002RAIL,2x50W,ACfor2supply X800-91-0002RAIL,2x50W,AC+X-DCfor2supply X800-92-0002RAIL,2x50W,ACfor2supply X800-93-0002RAIL,2x50W,AC+BATfor2supply X800-94-0002RAIL,2x50W,X-DC+BATfor2supply X800-95-0002RAIL,2x50W,AC+X-DC+BATfor2supply
X800-90-0003RAIL,COMBI,ACfor2supply X800-91-0003RAIL,COMBI,AC+X-DCfor2supply X800-92-0003RAIL,COMBI,ACfor2supply X800-93-0003RAIL,COMBI,AC+BATfor2supply X800-94-0003RAIL,COMBI,X-DC+BATfor2supply X800-95-0003RAIL,COMBI,AC+X-DC+BATfor2supply
Page 74
T A I T
Radio Communications Christchurch New Zealand
DRAWING:
power rails cso.vsd
TITLE:
X800 - 9x - 0000
POWER RAIL OPTIONS for T800 RACKS
Drawn DateChecked
AMM 8/9/99ABB
AMM 26/10/99ABB
Version
12Original
Diode position changed
AC POWER SUPPLY EXTERNAL DC AND BATTERY
x = 5
EXTERNAL DC AND BATTERY
x = 4
AC POWER SUPPLY AND BATTERY
x = 3
EARTH
STUD
BATTERY BACK-UP
FUSE
TB1
OPTIONAL
POSITION
OUTPUT
ONLY 13.8V
MAX
2 AMPS
DIODE
PACK
EARTH
STUD
DC INPUT FUS E
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
EARTH
STUD
DC INPUT FUS E
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
DIODE
PACK
EARTH
STUD
BATTERY BACK-UP
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
DC INPUT FUSE
OPTIONAL
POSITION
DIODE
PACK
EARTH
STUD
BATTERY BACK-UP
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
DC INPUT FUSE
OPTIONAL
POSITION
DIODE
PACK
AC POWER SUPPLY ONLY
x = 0
EARTH
STUD
FUSE
TB1
OUTPUT
ONLY 13.8V
MAX
2 AMPS
EXTERNAL DC SUPPLY ONLY
x = 1
AC POWER SUPPLY AND EXTERNAL DC
x = 2
Loading...